VECTRON TFS215B

Filename: tfs 215b.doc
Version 1.3
VI TELEFILTER
19.01.2007
Filter specification
TFS 215B
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
701 Ω || -7,1 pF
658 Ω || -7,0 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 215B is the minimum of the pass band attenuation. This value is defined as the insertion
loss ae. The nominal frequency fN is fixed at 215 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating
temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
Insertion loss
(reference level)
ae
Nominal frequency
fN
5,3
tolerance / limit
dB
max.
215,0
PB
Passband
8,0
fN
± 335,0
dB
MHz
kHz
Pass band ripple
0
dB
max.
1,0
dB
Amplitude ripple at fN ± 385 kHz
0
dB
max.
2,0
dB
0,6
1,0
dB
dB
max.
max.
1
2
dB
dB
arel
Relative attenuation
fN
fN
±
… fN
… fN
±
±
335,0
385,0
fN
±
fN
±
1,05
MHz … fN
±
1,2
MHz
27
dB
min.
30
dB
1,2
MHz … fN
±
1,4
MHz
40
dB
min.
35
dB
fN
-
8,0
MHz … fN
-
1,4
MHz
45
dB
min.
40
dB
fN
+
1,4
MHz … fN
+
2,4
MHz
39
dB
min.
36
dB
fN
+
2,4
MHz … fN
+
8,0
MHz
45
dB
min.
40
dB
fN
±
8,0
MHz … fN
±
50,0
MHz
55
dB
min.
45
dB
335,0
kHz
Group delay
kHz
kHz
max value in PB
0,179
Group delay ripple within PB
Operating temperature range
OTR
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
-
TCf **
µs
max.
2,0
µs
max.
0,4
µs
-
- 40 °C ... + 85°C
-
- 40 °C ... + 85°C
35
°C
-0,036
ppm/K
2
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fTo(MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 215b.doc
Version 1.3
VI TELEFILTER
19.01.2007
Filter specification
TFS 215B
2/5
0
3.65
-1
3.35
-20
-2
3.05
-30
-3
2.75
-4
2.45
-5
2.15
-40
-50
-6
1.85
-70
-7
1.55
-80
-8
1.25
-90
-9
0.95
-60
-100
165
175
185
195
205
215
225
frequency in MHz
235
245
255
265
delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
-10
0.65
214.25 214.4 214.55 214.7 214.85 215 215.15 215.3 215.45 215.6 215.75
frequency in MHz
Construction and pin connection
(All dimensions in mm)
1
2
3
4
5
6
7
8
9
10
TFS215B
● V3
Input
Input RF Return
Ground
Ground
Ground
Output
Output or Output RF Return
Ground
Ground
Ground
Date code:
U
V
W
...
Year + week
2006
2007
2008
50 Ω test circuit
L1
1
2
6
SAW
L2
7
C2
C1
3, 4, 5, 8, 9, 10
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 215b.doc
Version 1.3
VI TELEFILTER
19.01.2007
Filter specification
TFS 215B
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
2000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,10
F
: 7,50 ± 0,10
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
: 1,50 +0,1/-0
Ao
: 7,60 ± 0,10
Bo
: 9,60 ± 0,10
Ct
: 13,5
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4
W2(max) : 22,4
N(min)
: 50
C
: 13,0
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 215b.doc
Version 1.3
VI TELEFILTER
19.01.2007
Filter specification
TFS 215B
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 215b.doc
VI TELEFILTER
Version 1.3
Filter specification
19.01.2007
TFS 215B
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
04.07.2006
1.1
- Change data
Strehl
01.09.2006
1.2
- Change relative attenuation
- Change pin connection
Alawneh
11.09.2006
1.3
- Change from development specification to filter specification
- Change relative attenuation
- Add terminating impedance
- Add typical values
- Add filter characteristics
- Add matching circuit
Alawneh
19.01.2007
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.