Filename: tfs 215b.doc Version 1.3 VI TELEFILTER 19.01.2007 Filter specification TFS 215B 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 701 Ω || -7,1 pF 658 Ω || -7,0 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 215B is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 215 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss (reference level) ae Nominal frequency fN 5,3 tolerance / limit dB max. 215,0 PB Passband 8,0 fN ± 335,0 dB MHz kHz Pass band ripple 0 dB max. 1,0 dB Amplitude ripple at fN ± 385 kHz 0 dB max. 2,0 dB 0,6 1,0 dB dB max. max. 1 2 dB dB arel Relative attenuation fN fN ± … fN … fN ± ± 335,0 385,0 fN ± fN ± 1,05 MHz … fN ± 1,2 MHz 27 dB min. 30 dB 1,2 MHz … fN ± 1,4 MHz 40 dB min. 35 dB fN - 8,0 MHz … fN - 1,4 MHz 45 dB min. 40 dB fN + 1,4 MHz … fN + 2,4 MHz 39 dB min. 36 dB fN + 2,4 MHz … fN + 8,0 MHz 45 dB min. 40 dB fN ± 8,0 MHz … fN ± 50,0 MHz 55 dB min. 45 dB 335,0 kHz Group delay kHz kHz max value in PB 0,179 Group delay ripple within PB Operating temperature range OTR Storage temperature range Frequency inversion temperature Temperature coefficient of frequency - TCf ** µs max. 2,0 µs max. 0,4 µs - - 40 °C ... + 85°C - - 40 °C ... + 85°C 35 °C -0,036 ppm/K 2 - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fTo(MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 215b.doc Version 1.3 VI TELEFILTER 19.01.2007 Filter specification TFS 215B 2/5 0 3.65 -1 3.35 -20 -2 3.05 -30 -3 2.75 -4 2.45 -5 2.15 -40 -50 -6 1.85 -70 -7 1.55 -80 -8 1.25 -90 -9 0.95 -60 -100 165 175 185 195 205 215 225 frequency in MHz 235 245 255 265 delay in µs 0 -10 magnitude in dB magnitude in dB Filter characteristic -10 0.65 214.25 214.4 214.55 214.7 214.85 215 215.15 215.3 215.45 215.6 215.75 frequency in MHz Construction and pin connection (All dimensions in mm) 1 2 3 4 5 6 7 8 9 10 TFS215B ● V3 Input Input RF Return Ground Ground Ground Output Output or Output RF Return Ground Ground Ground Date code: U V W ... Year + week 2006 2007 2008 50 Ω test circuit L1 1 2 6 SAW L2 7 C2 C1 3, 4, 5, 8, 9, 10 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 215b.doc Version 1.3 VI TELEFILTER 19.01.2007 Filter specification TFS 215B 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 2000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,10 F : 7,50 ± 0,10 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 12,00 ± 0,1 D1(min) : 1,50 +0,1/-0 Ao : 7,60 ± 0,10 Bo : 9,60 ± 0,10 Ct : 13,5 P1 Date Code Po Do P2 W G Ct Bo F G E t Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 W2(max) : 22,4 N(min) : 50 C : 13,0 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 215b.doc Version 1.3 VI TELEFILTER 19.01.2007 Filter specification TFS 215B 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 215b.doc VI TELEFILTER Version 1.3 Filter specification 19.01.2007 TFS 215B 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 04.07.2006 1.1 - Change data Strehl 01.09.2006 1.2 - Change relative attenuation - Change pin connection Alawneh 11.09.2006 1.3 - Change from development specification to filter specification - Change relative attenuation - Add terminating impedance - Add typical values - Add filter characteristics - Add matching circuit Alawneh 19.01.2007 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.