Filename: tfs 243e.doc Version 1.5 VI TELEFILTER 21.02.2006 Filter specification TFS 243E 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 350 Ω || -3,8 pF 350 Ω || -3,8 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 243E is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 243,0 MHz without any tolerance. The given values for both the relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value ae Insertion loss (reference level) fN Nominal frequency max. - 243,0 dB max. ±0,5 dB MHz kHz dB BW Bandwidth 0,5 dB 3 dB 440 Relative attenuation 0,50 1,00 3,00 5,00 8,00 2,5 fN ± 25 0,15 Pass band ripple ± ± ± ± ± dB PB Passband fN fN fN fN fN 1,35 tolerance / limit MHz MHz MHz MHz MHz … … … … … fN fN fN fN fN ± ± ± ± ± 1,00 3,00 5,00 8,00 20,00 arel MHz MHz MHz MHz MHz OTR Storage temperature range Temperature coefficient of frequency dB dB dB dB dB - Input power level Operating temperature range 15 30 37 43 48 TCf ** min. ± 25 - min. min. min. min. min. 7 25 25 25 40 dB dB dB dB dB max. 15 dBm KHz - - 40 °C ... + 85°C - - 45 °C ... + 90°C -0,032 ppm/K kHz 2 *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 243e.doc Version 1.5 VI TELEFILTER 21.02.2006 Filter specification TFS 243E 2/5 0 0 -10 -0.5 -20 -1 -30 -1.5 magnitude in dB magnitude in dB Filter characteristic -40 -50 -60 -2 -2.5 -3 -70 -3.5 -80 -4 -90 -4.5 -100 230 235 240 245 frequency in MHz 250 -5 255 242.8 242.85 242.9 242.95 243 243.05 243.1 243.15 243.2 243.25 frequency in MHz Construction and pin connection (All dimensions in mm) S 243E ● U08 3 Date cod e 2 Max. 1 Input Ground Ground Ground Ground Ground Output Ground Ground Ground Ground Ground Date code: U V W ... Year + week 2006 2007 2008 1 5,2 Max. 2,54 ±0,2 7,2 Max. 2,54 ±0,2 1 1 2 3 4 5 6 7 8 9 10 11 12 0,80 50 Ω Test circuit L1 1 7 L2 SAW 2, 3, 4, 5, 6, 8, 9, 10, 11, 12 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 243e.doc Version 1.5 VI TELEFILTER 21.02.2006 Filter specification TFS 243E 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 7,50 ± 0,1 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 5,50 ± 0,1 Bo : 7,50 ± 0,1 Ct : 13,5 ± 0,1 P1 Date Code Po Do P2 W G Ct Bo F G E t Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 243e.doc Version 1.5 VI TELEFILTER 21.02.2006 Filter specification TFS 243E 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 243e.doc VI TELEFILTER Version 1.5 Filter specification 21.02.2006 TFS 243E 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 27.07.2005 1.1 - Add bandwidth@1dB Strehl 30.08.2005 1.2 - Generation of filter specification and add of typical values Sabah 27.10.2005 1.3 Strehl 08.02.2006 1.4 - Change insertion loss, bandwidth and relative attenuation - Change stability characteristics - Correct relative attenuation Strehl 16.02.2006 1.5 - Correct filter characteristic Strehl 21.02.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.