VECTRON TFS243E

Filename: tfs 243e.doc
Version 1.5
VI TELEFILTER
21.02.2006
Filter specification
TFS 243E
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
350 Ω || -3,8 pF
350 Ω || -3,8 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 243E is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 243,0 MHz without any tolerance. The given values for both the
relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
ae
Insertion loss
(reference level)
fN
Nominal frequency
max.
-
243,0
dB
max.
±0,5
dB
MHz
kHz
dB
BW
Bandwidth
0,5 dB
3
dB
440
Relative attenuation
0,50
1,00
3,00
5,00
8,00
2,5
fN ± 25
0,15
Pass band ripple
±
±
±
±
±
dB
PB
Passband
fN
fN
fN
fN
fN
1,35
tolerance / limit
MHz
MHz
MHz
MHz
MHz
…
…
…
…
…
fN
fN
fN
fN
fN
±
±
±
±
±
1,00
3,00
5,00
8,00
20,00
arel
MHz
MHz
MHz
MHz
MHz
OTR
Storage temperature range
Temperature coefficient of frequency
dB
dB
dB
dB
dB
-
Input power level
Operating temperature range
15
30
37
43
48
TCf **
min.
± 25
-
min.
min.
min.
min.
min.
7
25
25
25
40
dB
dB
dB
dB
dB
max.
15
dBm
KHz
-
- 40 °C ... + 85°C
-
- 45 °C ... + 90°C
-0,032
ppm/K
kHz
2
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 243e.doc
Version 1.5
VI TELEFILTER
21.02.2006
Filter specification
TFS 243E
2/5
0
0
-10
-0.5
-20
-1
-30
-1.5
magnitude in dB
magnitude in dB
Filter characteristic
-40
-50
-60
-2
-2.5
-3
-70
-3.5
-80
-4
-90
-4.5
-100
230
235
240
245
frequency in MHz
250
-5
255
242.8 242.85 242.9 242.95 243 243.05 243.1 243.15 243.2 243.25
frequency in MHz
Construction and pin connection
(All dimensions in mm)
S 243E
● U08
3
Date cod e
2 Max.
1
Input
Ground
Ground
Ground
Ground
Ground
Output
Ground
Ground
Ground
Ground
Ground
Date code:
U
V
W
...
Year + week
2006
2007
2008
1
5,2 Max.
2,54 ±0,2
7,2 Max.
2,54 ±0,2
1
1
2
3
4
5
6
7
8
9
10
11
12
0,80
50 Ω Test circuit
L1
1
7
L2
SAW
2, 3, 4, 5, 6, 8, 9, 10, 11, 12
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 243e.doc
Version 1.5
VI TELEFILTER
21.02.2006
Filter specification
TFS 243E
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,50 ± 0,1
Bo
: 7,50 ± 0,1
Ct
: 13,5 ± 0,1
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 243e.doc
Version 1.5
VI TELEFILTER
21.02.2006
Filter specification
TFS 243E
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 243e.doc
VI TELEFILTER
Version 1.5
Filter specification
21.02.2006
TFS 243E
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
27.07.2005
1.1
- Add bandwidth@1dB
Strehl
30.08.2005
1.2
- Generation of filter specification and add of typical values
Sabah
27.10.2005
1.3
Strehl
08.02.2006
1.4
- Change insertion loss, bandwidth and relative attenuation
- Change stability characteristics
- Correct relative attenuation
Strehl
16.02.2006
1.5
- Correct filter characteristic
Strehl
21.02.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.