Filename: tfs 468c.doc Version 1.2 VI TELEFILTER 04.11.2005 Filter specification TFS 468C 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 825 Ω || -3,6 pF 830 Ω || -3,7 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 468C is the minimum attenuation in the pass band. The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 468,0 MHz without any tolerance or limit. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value ae = amin Insertion loss (reference level) fN Nominal frequency PB Passband Pass band ripple ± 2,25 fN ± fN ± fN ± fN fN dB max. - 14,0 468,0 - fN ± 2,25 dB MHz MHz 0,6 dB max. 1,0 dB 0,6 2,4 dB dB max. max. 1 3 dB dB arel Relative attenuation fN fN 11,0 tolerance / limit … fN MHz … fN ± ± 2,25 2,5 MHz MHz 3,5 MHz … fN 5 MHz … fN ± 5 MHz 20 dB min. 15 dB ± 10 MHz 42 dB min. 35 10 dB MHz … fN ± 20 MHz 48 dB min. 40 dB + - 20 MHz … fN + 532 MHz 60 dB min. 50 dB 438 MHz … fN - 20 MHz 70 dB min. 50 dB µs max. 143 ns max. 250 ns 15 dB min. 10 dB max. 15 dBm 0,45 Absolute group delay within PB Group deley ripple within fN ± 2,5 MHz Return loss within PB - Input power level Operating temperature range OTR Storage temperature range Frequency inversion temperature Temperature coefficient of frequency TCf ** 3,0 - - 40 °C ... + 85°C - - 45 °C ... + 85°C 30 °C -0,047 ppm/K µs 2 *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 468c.doc Version 1.2 VI TELEFILTER 04.11.2005 Filter specification TFS 468C 2/5 0 2.3 -1 2.09 -14 -2 1.88 -21 -3 1.67 -28 -4 1.46 -5 1.25 -6 1.04 -49 -7 0.83 -56 -8 0.62 -63 -9 0.41 -35 -42 -70 418 428 438 448 458 468 478 frequency in MHz 488 498 508 518 -10 465 465.6 466.2 466.8 467.4 468 468.6 frequency in MHz 469.2 469.8 470.4 delay in µs 0 -7 magnitude in dB magnitude in dB Filter characteristic 0.2 471 Construction and pin connection (All dimensions in mm) S 468C ● T45 3 Date code 2 Max. 1 1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Ground Output Ground Output RF Return Ground Ground Ground Input Ground Input RF Return Date code: T U V ... Year + week 2005 2006 2007 1 5,2 Max. 2,54 ±0,2 7,2 Max. 2,54 ±0,2 1 0,80 50 Ω Test circuit 10 L 4 L SAW C L 2 12 6 L 4 C 1, 2, 3, 5, 7, 8, 9, 11 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 468c.doc Version 1.2 VI TELEFILTER 04.11.2005 Filter specification TFS 468C 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 7,50 ± 0,1 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 5,50 ± 0,1 Bo : 7,50 ± 0,1 Ct : 13,5 ± 0,1 t P1 Date Code Po P2 W G Ct Bo F G E Do Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 468c.doc Version 1.2 VI TELEFILTER 04.11.2005 Filter specification TFS 468C 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 468c.doc VI TELEFILTER Version 1.2 Filter specification 04.11.2005 TFS 468C 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 21.07.2005 1.1 - Change construction and pin connection Strehl 10.08.2005 1.2 - terminating impedance, typical values, filter characteristic and matching configuration added Pfeiffer 04.11.2005 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.