VECTRON TFS468C

Filename: tfs 468c.doc
Version 1.2
VI TELEFILTER
04.11.2005
Filter specification
TFS 468C
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
825 Ω || -3,6 pF
830 Ω || -3,7 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 468C is the minimum attenuation in the pass band. The maximum attenuation in the pass
band is defined as the insertion loss ae. The nominal frequency fN is fixed at 468,0 MHz without any tolerance or limit. The values of relative attenuation
arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the
production tolerance scheme.
Data
typ. value
ae = amin
Insertion loss
(reference level)
fN
Nominal frequency
PB
Passband
Pass band ripple
±
2,25
fN
±
fN
±
fN
±
fN
fN
dB
max.
-
14,0
468,0
-
fN ± 2,25
dB
MHz
MHz
0,6
dB
max.
1,0
dB
0,6
2,4
dB
dB
max.
max.
1
3
dB
dB
arel
Relative attenuation
fN
fN
11,0
tolerance / limit
… fN
MHz … fN
±
±
2,25
2,5
MHz
MHz
3,5
MHz … fN
5
MHz … fN
±
5
MHz
20
dB
min.
15
dB
±
10
MHz
42
dB
min.
35
10
dB
MHz … fN
±
20
MHz
48
dB
min.
40
dB
+
-
20
MHz … fN
+
532
MHz
60
dB
min.
50
dB
438
MHz … fN
-
20
MHz
70
dB
min.
50
dB
µs
max.
143
ns
max.
250
ns
15
dB
min.
10
dB
max.
15
dBm
0,45
Absolute group delay within PB
Group deley ripple within fN ± 2,5 MHz
Return loss within PB
-
Input power level
Operating temperature range
OTR
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
TCf **
3,0
-
- 40 °C ... + 85°C
-
- 45 °C ... + 85°C
30
°C
-0,047
ppm/K
µs
2
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 468c.doc
Version 1.2
VI TELEFILTER
04.11.2005
Filter specification
TFS 468C
2/5
0
2.3
-1
2.09
-14
-2
1.88
-21
-3
1.67
-28
-4
1.46
-5
1.25
-6
1.04
-49
-7
0.83
-56
-8
0.62
-63
-9
0.41
-35
-42
-70
418
428
438
448
458
468
478
frequency in MHz
488
498
508
518
-10
465
465.6
466.2
466.8
467.4
468
468.6
frequency in MHz
469.2
469.8
470.4
delay in µs
0
-7
magnitude in dB
magnitude in dB
Filter characteristic
0.2
471
Construction and pin connection
(All dimensions in mm)
S 468C
●
T45
3
Date code
2 Max.
1
1
2
3
4
5
6
7
8
9
10
11
12
Ground
Ground
Ground
Output
Ground
Output RF Return
Ground
Ground
Ground
Input
Ground
Input RF Return
Date code:
T
U
V
...
Year + week
2005
2006
2007
1
5,2 Max.
2,54 ±0,2
7,2 Max.
2,54 ±0,2
1
0,80
50 Ω Test circuit
10
L
4
L
SAW
C
L
2
12
6
L
4
C
1, 2, 3, 5, 7, 8, 9, 11
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 468c.doc
Version 1.2
VI TELEFILTER
04.11.2005
Filter specification
TFS 468C
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,50 ± 0,1
Bo
: 7,50 ± 0,1
Ct
: 13,5 ± 0,1
t
P1
Date Code
Po
P2
W
G
Ct
Bo
F
G
E
Do
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 468c.doc
Version 1.2
VI TELEFILTER
04.11.2005
Filter specification
TFS 468C
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 468c.doc
VI TELEFILTER
Version 1.2
Filter specification
04.11.2005
TFS 468C
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
21.07.2005
1.1
- Change construction and pin connection
Strehl
10.08.2005
1.2
- terminating impedance, typical values, filter characteristic and matching configuration added Pfeiffer
04.11.2005
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.