Filename: tfs 90f.doc Version 1.2 Vectron International 01.02.2012 Filter specification TFS 90F 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 403 Ω || -29 pF 450 Ω || -28 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 90F is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 90,0 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss (reference level) ae 6,5 Nominal frequency fN - PB Passband p-p Pass band ripple dB dB ... fN ± 0,63 arel MHz MHz ... fN ± MHz ... fN ± 6,0 20,0 MHz MHz Relative attenuation fN fN ± fN ± 2,0 6,0 - max. fN ± 10,0 dB 90,0 MHz 0,63 MHz 0,26 dB max. 1,0 dB 1,81 3,42 MHz MHz min. max. 1,26 4,0 0,26 dB max. 1 dB 39 47 dB dB min. min. 30 40 dB dB 50 ns max. 300 ns 16 dB min. 10 dB BW Bandwidth 1 30 dB tolerance / limit Group delay ripple within fN ± 0,8 MHz p-p Return loss within PB Operating temperature range OTR Storage temperature range Temperature coefficient of frequency TCf ** - - 40 °C ... + 85 °C - - 40 °C ... + 85 °C -15,5 ppm/K MHz MHz - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz). Generated: Checked / Approved: Vectron International GmbH & Co. KG Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 90f.doc Version 1.2 Vectron International 01.02.2012 Filter specification TFS 90F 2/5 Filter characteristic 3.4 -1 3.16 -20 -2 2.92 -30 -3 2.68 -40 -4 2.44 -5 2.2 -6 1.96 -70 -7 1.72 -80 -8 1.48 -90 -9 1.24 -50 -60 -100 65.7 70.56 75.42 80.28 85.14 90 94.86 frequency in MHz 99.72 104.58 109.44 -10 88 114.3 88.4 88.8 89.2 89.6 90 90.4 frequency in MHz 90.8 91.2 91.6 delay in µs 0 -10 magnitude in dB magnitude in dB insertion loss: -7.39 dB 0 1 92 Construction and pin connection (All dimensions in mm) TPS-F-2417-3 1 10 X06 1,0± 0,2 1,91± 0,2 7,62± 0,2 5 Date code 1,9± 0,2 ● 1,8± 0,2 6,5 ± 0,2 ± 0,2 1 2 3 4 5 6 7 8 9 10 Input Ground Ground Ground Output RF Return Output Ground Ground Ground Input RF Return Date code: X A B ... Year + week 2009 2010 2011 6 50 Ω Test circuit L1 1 10 6 SAW L2 5 C2 C1 2, 3, 4, 7, 8, 9 Vectron International GmbH & Co. KG Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 90f.doc Version 1.2 Vectron International 01.02.2012 Filter specification TFS 90F 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): 5. ESD -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; ANSI/ESD S20.20-1999, class 1A for HBM This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 1700 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W :24,00 +0,30/-0,10 Po :4,00 ± 0,1 Do :1,50 +0,1/0 E :1,75 ± 0,10 F :11,50 ± 0,10 G(min) :0,60 P2 :2,00 ± 0,1 P1 :12,00 ± 0,1 D1(min) :1,50 Ao :7,10 ± 0,10 Bo :13,90 ± 0,10 Ct :21,5 ± 0,1 P1 Date Code Po Do P2 W G Ct Bo F G E t Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 :24,4 +2/-0 W2(max) :30,4 N(min) : 60 C :13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Vectron International GmbH & Co. KG Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 90f.doc Version 1.2 Vectron International 01.02.2012 Filter specification TFS 90F 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Vectron International GmbH & Co. KG Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 90f.doc Vectron International Version 1.2 Filter specification 01.02.2012 TFS 90F 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 01.10.2008 1.1 - Change from development specification to filter specification - Add terminating impedances - Add typical values - Add filter characteristics - Add matching circuit Alawneh 05.02.2009 1.2 - Customer request to update labelling, change form TFS90G to TPS-F-2417-3 TCUK 01.02.2012 Vectron International GmbH & Co. KG Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.