Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
50
50
Ω
Ω
Characteristics
Remark:
The reference level for the relative attenuation of the TFS456AL is the minimum attenuation in the pass band. The maximum attenuation in the pass band
is defined as the insertion loss ae. The nominal frequency fN is fixed at 456,0 MHz without any tolerance or limit. The values of absolute attenuation aabs
are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production
tolerance scheme.
Data
typ. value
Insertion loss
(reference level)
ae
2,0
Nominal frequency
fN
-
PB
Passband
p-p
Pass band variation
MHz
MHz
0,5
max.
fN
dB
max.
3,5
±
dB
456,0
MHz
9,25
MHz
0,7
dB
aabs
Absolute attenuation
400
530
dB
tolerance / limit
…
…
410
540
Group delay ripple within PB
MHz
MHz
65
55
dB
dB
min.
min.
40
40
dB
dB
p-p
13
ns
max.
15
ns
-
max.
10
dBm
-
- 10 °C ... + 75 °C
Input power level
Operating temperature range
OTR
-
Storage temperature range
Temperature coefficient of frequency
TCf **
- 76
- 40 °C ... + 85 °C
ppm/K
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fT0 (MHz).
Generated:
Checked / Approved:
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.
Filename: tfs 456al.doc
Version 1.2
Vectron International
05.11.2009
Filter specification
TFS 456AL
2/5
0
0.138
-1
0.126
-20
-2
0.114
-30
-3
0.102
-40
-4
0.09
-5
0.078
-6
0.066
-70
-7
0.054
-80
-8
0.042
-90
-9
0.03
-50
-60
-100
6
96
186
276
366
456
546
frequency in MHz
636
726
816
-10
436
906
440
444
448
452
456
460
frequency in MHz
464
468
472
delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
0.018
476
Construction and pin connection
(All dimensions in mm)
456AL
● X45
1
2
3
4
5
6
7
8
Ground
Input
Ground
Ground
Ground
Output
Ground
Ground
Date code:
X
A
B
...
Year + week
2009
2010
2011
50 Ω Test circuit
L1
2
6
L2
SAW
1, 3, 4, 5, 7, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 456al.doc
Version 1.2
Vectron International
05.11.2009
Filter specification
TFS 456AL
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 5,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 4,30 ± 0,1
Bo
: 4,30 ± 0,1
Ct
: 9,5 ± 0,1
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 456al.doc
Version 1.2
Vectron International
05.11.2009
Filter specification
TFS 456AL
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 456al.doc
Vectron International
Version 1.2
Filter specification
05.11.2009
TFS 456AL
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Chilla
21.11.2007
1.1
- Change characteristics, change construction and pin connection
- add test circuit
Channaa
07.12.2007
1.2
- Add typical values and filter characteristic
- Generation of filter specification
Channaa
05.11.2009
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.