TFS168C - Vectron International

Filename: tfs 168c.doc
Version 1.1
Vectron International
03.12.2008
Filter specification
TFS 168C
1/5
vMeasurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
25
0
°C
dBm
83 Ω || -30,3 pF
53 Ω || -38,7 pF
Characteristics
Remark:
The nominal frequency fN is fixed at 168,96 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative
attenuation arel of the TFS 168C is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3
dB filter attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range.
Data
typ. value
ae = amin
Insertion loss
(reference level)
fN
-
PB
14
Nominal frequency
Passband
p-p
Pass band ripple
fN
fN
fN
fN
fN
±
±
±
±
±
7,5
17,5
21,5
25,5
66,0
MHz
MHz
MHz
MHz
MHz
dB
max.
20,5
dB
168,96
MHz
6,67
MHz
MHz
fN
0,4
dB
max.
1
dB
±
arel
Relative attenuation
fN
17,8
tolerance / limit
… fN
±
6.67
MHz
0,5
dB
max.
1
dB
…
…
…
…
…
±
±
±
±
±
17,5
21,5
25,5
66,0
111,0
MHz
MHz
MHz
MHz
MHz
2,5
55
52
49
62
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
2
40
40
40
40
dB
dB
dB
dB
dB
max.
120
ns
fN
fN
fN
fN
fN
35
Group delay ripple within PB
Phase linearity within fN - 5 MHz … - 1,92 MHz
rms
0,5
deg
max.
2
deg
Phase linearity within fN ± 1,92 MHz
rms
0,5
deg
max.
1
deg
Phase linearity within fN + 1,92 MHz …+ 5 MHz
rms
0,5
deg
max.
1,5
deg
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf **
-
+25 °C ... + 85°C
-
- 45 °C ... + 85°C
-18
ppm/K
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fcat(MHz).
Generated:
Checked / Approved:
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.
Filename: tfs 168c.doc
Version 1.1
Vectron International
03.12.2008
Filter specification
TFS 168C
2/5
Filter characteristic
0
0
-10
1.35
-1
-30
-40
-2
1.15
delay in µs
magnitude in dB
magnitude in dB
-20
-3
0.95
-50
-4
-60
0.75
-70
79
97
115
133
151
169
187
frequency in MHz
205
223
241
-5
161
259
163
165
167
169
171
frequency in MHz
173
175
177
Construction and pin connection
(All dimensions in mm)
5,0Max.
8
9
10
9,3 Max.
6
7
TFS 168C
●
W49
2
4
3
Date code
Ground
Ground
Ground
Output
Output RF Return
Ground
Ground
Ground
Input
Input RF Return
Date code:
U
V
W
...
Year + week
2006
2007
2008
2,54 ±0,12,54 ±0,1
0,10
°
60 1
2
3
4
10
9
5
8
7
0,8
7,1
2,8
2,54 ±0,1
1,8 Max.
1
5
1
2
3
4
5
6
7
8
9
10
6
50 Ohm Test circuit
L1
9
10
4
SAW
L2
5
C2
C1
1, 2, 3, 7, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 168c.doc
Version 1.1
Vectron International
03.12.2008
Filter specification
TFS 168C
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,30 ± 0,1
Bo
: 9,70 ± 0,1
Ct
: 13,5 ± 0,1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 168c.doc
Version 1.1
Vectron International
03.12.2008
Filter specification
TFS 168C
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 168c.doc
Vectron International
Version 1.1
Filter specification
03.12.2008
TFS 168C
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
14.12.2006
1.1
- Created Filter specification
- Added terminating impedance
- Added typical values
- Changed operating temperature range
- Added filter characteristic
- Added filter test circuit
Chilla
03.12.2008
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.