Filename: tfs 190e.doc Version 1.2 VI TELEFILTER 23.12.2005 Filter specification TFS 190E 1/5 Measurement condition °C dBm Ambient Temperature: 23 Input Power Level: 0 Terminating Impedance at fc*: input: output: 307 Ω // - 12,4 pF 107 Ω // - 16,9 pF Characteristics Remark: The reference level for the relative attenuation arel of TFS 190E is the minimum of the pass band attenuation amin. This minimum is defined as the insertion loss ae. The nominal frequency fN is fixed at 190 MHz without any tolerance. The given values for the relative attenuation arel and the group delay ripple have to be reached at the frequencies given below, even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. Value Insertion Loss (Reference Level) ae = amin Nominal Frequency fN - Pass Band PB 125 Group Delay Variation within PB Relative Attenuation fN ... fN ± @ fN ± 2,50 MHz ... @ fN - 180,00 MHz ... fN + 3,75 MHz ... fN + 60,00 MHz ... arel 1,92 MHz fN ± 2,50 fN ± 3,75 fN + 3,75 fN 3,75 fN + 60,00 fN + 310,00 21,0 dB 52 50 54 58 54 60 ± 1,92 MHz fN ns dB dB dB dB dB dB max. 300 ns p-p max. 1 dB min. min. min. min. min. min. 30 30 45 48 43 50 dB dB dB dB dB dB -30... Operating Temperature Range -40... +85 Storage Temperature Range Temperature Coefficient of frequency TCf max. 24,0 dB 190,0 MHz 0,8 dB MHz MHz MHz MHz MHz MHz Limit ** - 0,036 ppm / K2 +85 ° C °C - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K) x (T-T0)2 x fTo(MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 190e.doc Version 1.2 VI TELEFILTER 23.12.2005 Filter specification TFS 190E 2/5 Filter characteristic 0 0 5.11 -6 -1 4.87 -2 4.63 -3 4.39 -4 4.15 -5 3.91 -6 3.67 -7 3.43 -8 3.19 -9 2.95 -12 -18 -30 -36 delay in µs magnitude in dB magnitude in dB -24 -42 -48 -54 -60 180 182 184 186 188 190 192 frequency in MHz 194 196 198 -10 188 200 188.4 188.8 189.2 189.6 190 190.4 frequency in MHz 190.8 191.2 191.6 2.71 192 Construction and pin connection (All dimensions in mm) 9 ±0,2 24,64 ±0,2 TFS 190E ● T52 1 Input RF Return Ground Ground Ground Output Output RF Return Ground Ground Ground Input Date code: T U V ... Year + week 2005 2006 2007 2,6 Max. Date code 1 2 3 4 5 6 7 8 9 10 2,31 3,53X4,83 1 2 3 4 5 10 9 8 7 6 1,02 1,91 ±0,2 50 Ohm Test circuit L1 10 1 5 SAW L2 6 C2 C1 2, 3, 4, 7, 8, 9 Stability characteristics, reliability Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 190e.doc Version 1.2 VI TELEFILTER 23.12.2005 Filter specification TFS 190E 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: Pull Off Direction Ko Date Code P1 P2 Ao Bo Po Ct So Do E t W Tape (all dimensions in mm) W : 44,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 20,20 ± 0,15 P2 : 2,00 ± 0,15 P1 : 16,00 ± 0,1 D1(min) : 2,00 Ao : 9,30 ± 0,1 Bo : 24,90 ± 0,1 So : 40,40 ± 0,1 Ct : 38,0 ± 0,1 1000 min. 300 mm min. 500 mm min. 300 mm Type PIN Marker D1 W2 Reel (all dimensions in mm) A : 330 W1 : 44,4 +2/-0 W2(max) : 50,4 N(min) : 100 C : 13,0 +0,5/-0,2 C A N W1 The minimum bending radius is 45 mm. Air reflow temperature conditions Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 190e.doc Version 1.2 VI TELEFILTER 23.12.2005 Filter specification Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature TFS 190E 4/5 Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 190e.doc VI TELEFILTER Version 1.2 Filter specification 23.12.2005 TFS 190E 5/5 History Version Reason of Changes Name Date 1.0 generation of specification according to customer requirements Pfeiffer 30.10.2001 1.1 typical values added terminating impedance added (preliminary value) Pfeiffer 05.02.2002 1.2 - typical values corrected and added - filter characteristic added - air reflow temperature conditions and stability characteristics modified Pfeiffer 23.12.2005 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.