FL SWITCH SFNT… Five and Eight-Port Standard Function Ethernet Switches for Extreme Environments AUTOMATION Data Sheet 2665_en_I 1 © PHOENIX CONTACT 2011-06-30 Description The FL SWITCH SFNT… range of Factory Line switches can be used for quick and cost-effective Ethernet network expansion to the field level. These unmanaged switches allow operation across a wider temperature range than most switches, allowing networks to expand into process industry environments, such as oil/gas, chemical, water/wastewater, wind energy, security, monitoring and some marine segments. Due to the narrow housing design, the switches are suitable for use in control cabinets and junction boxes. The FL SWITCH SFNT… switches support the auto negotiation function on the RJ45 ports and offer transmission speeds of 10/100 Mbps. Mixed operation for the connection of segments with different data transmission speeds is also supported. The RJ45 ports offer an auto crossing function, which means it is not necessary to make a distinction between 1:1 and crossover cables. Unused RJ45 ports can be fitted with security caps to provide mechanical protection against unauthorized use. Fiber optic ports are available in an SC or ST format and offer speeds of 100 Mbps. The fiber optic ports extend the segment length to 2000 m or more, depending on the quality of the fiber optic cable. 2 – – – – – – – – – – Features and Benefits -40 to 75°C operating range Pretagged high priority messages are forwarded before lower priority messages during periods of high network traffic Auto-negotiation and autocross simplify cabling Couple copper network segments with different bit rates with automatic detection of the data transmission speed of 10 or 100 Mbps Individual LEDs at each port indicate communication activity and data rate Redundant power supply capable with local (LED) and remote (dry contact) alarms to indicate failure of one or both power supplies Switch-selectable link diagnostics indicate disconnected ports via local and remote alarms Available fiber optic options for extended distance and electrical noise immunity Fiber optic ports available in SC or ST formats Low-cost, low-complexity security by connecting Layer 1 security elements at the RJ45 ports to restrict access and tampering (optional) Please note the different connection directions of the transmission media for five-port switches: copper cables are connected at the front, glass fiber cables at the bottom. This data sheet is valid for all products listed on the following page: Make sure you always use the latest documentation. It can be downloaded at www.phoenixcontact.net/catalog. FL SWITCH SFNT… 3 Ordering Data Description Type Order No. Pcs./Pkt. Ethernet switch, wide temperature with 5 RJ45 ports for 10/100 Mbps FL SWITCH SFNT 5TX 2891003 1 Ethernet switch, wide temperature with 8 RJ45 ports for 10/100 Mbps FL SWITCH SFNT 8TX 2891005 1 Ethernet switch, wide temperature with 4 RJ45 ports and 1 fiber optic port in SC format, for 10/100 Mbps FL SWITCH SFNT 4TX/FX 2891004 1 Ethernet switch, wide temperature with 7 RJ45 ports and 1 fiber optic port in SC format, for 10/100 Mbps FL SWITCH SFNT 7TX/FX 2891006 1 Ethernet switch, wide temperature with 7 RJ45 ports and 1 fiber optic port in ST format, for 10/100 Mbps FL SWITCH SFNT 7TX/FX ST 2891007 1 Ethernet switch, wide temperature with 6 RJ45 ports and 2 fiber optic ports in SC format, for 10/100 Mbps FL SWITCH SFNT 6TX/2FX 2891025 1 Ethernet switch, wide temperature with 6 RJ45 ports and 2 fiber optic ports in ST format, for 10/100 Mbps FL SWITCH SFNT 6TX/2FX ST 2891026 1 Ethernet switch, wide temperature with 5 RJ45 ports for 10/100 Mbps, with conformal coating FL SWITCH SFNT 5TX-C 2891043 1 Ethernet switch, wide temperature with 8 RJ45 ports for 10/100 Mbps, with conformal coating FL SWITCH SFNT 8TX-C 2891044 1 Ethernet switch, wide temperature with 4 RJ45 ports and 1 fiber optic port in SC format, for 10/100 Mbps, with conformal coating FL SWITCH SFNT 4TX/FX-C 2891045 1 Ethernet switch, wide temperature with 7 RJ45 ports and 1 fiber optic port in SC format, for 10/100 Mbps, with conformal coating FL SWITCH SFNT 7TX/FX-C 2891046 1 Ethernet switch, wide temperature with 7 RJ45 ports and 1 fiber optic port in ST format, for 10/100 Mbps, with conformal coating FL SWITCH SFNT 7TX/FX ST-C 2891047 1 Ethernet switch, wide temperature with 6 RJ45 ports and 2 fiber optic ports in SC format, for 10/100 Mbps, with conformal coating FL SWITCH SFNT 6TX/2FX-C 2891048 1 Ethernet switch, wide temperature with 6 RJ45 ports and 2 fiber optic ports in ST format, for 10/100 Mbps, with conformal coating FL SWITCH SFNT 6TX/2FX ST-C 2891049 1 Accessories Description Type Order No. Pcs./Pkt. Universal end clamp E/NS 35 N 0800886 50 Patch angle with 2 ports in CAT 5e FL PF 2TX CAT5E 2891165 1 Patch angle with 8 ports in CAT 5e FL PF 8TX CAT5E 2891178 1 Patch angle with 2 ports in CAT 6 FL PF 2TX CAT6 2891068 1 Patch angle with 8 ports in CAT 6 FL PF 8TX CAT6 2891071 1 Patch angle with security elements for 2 ports in CAT 5e FL PF SEC 2TX 2832687 1 Patch angle with security elements for 8 ports in CAT 5e FL PF SEC 8TX 2832690 1 Patchbox 8 x RJ45 CAT 5e, pre-assembled, can be retrofitted FL PBX 8TX 2832496 1 Patch cable, CAT 5, pre-assembled, 0.3 m long FL CAT5 PATCH 0,3 2832250 10 Patch cable, CAT 5, pre-assembled, 0.5 m long FL CAT5 PATCH 0,5 2832263 10 Patch cable, CAT 5, pre-assembled, 1.0 m long FL CAT5 PATCH 1,0 2832276 10 Patch cable, CAT 5, pre-assembled, 1.5 m long FL CAT5 PATCH 1,5 2832221 10 Patch cable, CAT 5, pre-assembled, 2.0 m long FL CAT5 PATCH 2,0 2832289 10 Patch cable, CAT 5, pre-assembled, 3.0 m long FL CAT5 PATCH 3,0 2832292 10 Patch cable, CAT 5, pre-assembled, 5.0 m long FL CAT5 PATCH 5,0 2832580 10 Patch cable, CAT 5, pre-assembled, 7.5 m long FL CAT5 PATCH 7,5 2832616 10 Patch cable, CAT 5, pre-assembled, 10.0 m long FL CAT5 PATCH 10 2832629 10 Security frame for SFN switch and patch fields, green FL PLUG GUARD, GN 2891615 20 Security frame for SFN switch and patch fields, red FL PLUG GUARD, RD 2891712 20 Security frame for SFN switch and patch fields, white FL PLUG GUARD, WH 2891819 20 Security frame for SFN switch and patch fields FL PORT GUARD 2891220 20 Security frame for SFN switch and patch fields FL PLUG GUARD KEY 2891327 1 20 Security element for FL CAT patch FL PATCH SAFE CLIP 2891246 Mounting plate for SFNT… 5 and 8 port switches FL PA SFNT 5-8 2891012 1 Mounting plate, DIN rail, for SFNT… 5 and 8 port switches FL DA SFNT 5-8 2891017 1 2665_en_I PHOENIX CONTACT 2 FL SWITCH SFNT… 4 Technical Data General Data Function Switch/repeater; conforms to standard IEEE 802.3 Latency of the communication processor 8 µs plus frame time Housing dimensions (width x height x depth) 5-port switch, without connectors 8-port switch, without connectors 30 x 130 x 100 mm 50 x 130 x 100 mm Weight, without connectors FL SWITCH SFNT 5TX(-C) FL SWITCH SFNT 8TX(-C) FL SWITCH SFNT 4TX/FX(-C) FL SWITCH SFNT 7TX/FX(-C) FL SWITCH SFNT 7TX/FX ST(-C) FL SWITCH SFNT 6TX/2FX(-C) FL SWITCH SFNT 6TX/2FX ST (-C) 271 g 457 g 276 g 464 g 465 g 484 g 484 g Operating temperature -40°C to 75°C Storage temperature -40°C to 85°C Degree of protection IP20, DIN 40050, IEC 60529 Protection class Class 3 VDE 0106; IEC 60536 Humidity (operation and storage) 5% to 95%, no condensation Air pressure (operation) 62 kPa to 108 kPa, 4160 m above sea level Air pressure (storage) 62 kPa to 108 kPa, 4160 m above sea level Mounting NS 35 (EN 60715) Preferred mounting position Perpendicular to a standard mounting rail Connection to protective earth ground Snapped onto a grounded mounting rail Supply Voltage (US) Connection type Removable, screw-clamp connector Wire size (solid/stranded/AWG) 0.2 to 2.5 mm² / 0.2 to 2.5 mm² / 24 to 12 AWG Recommended PE wire size 2.5 mm2 Nominal power supply 24 V DC Permissible ripple 3.6 Vpp within the permissible voltage range Permissible voltage range 9 V DC to 32 V DC Test voltage 500 V DC for one minute Protection against polarity reversal Present Current Consumption and Inrush Current FL SWITCH SFNT 5TX(-C) Current Consumption (max) @ 24 V DC Inrush Current 120 mA 5.0 A for 68 µs FL SWITCH SFNT 8TX(-C) 153 mA 7.0 A for 30 µs FL SWITCH SFNT 4TX/FX(-C) 180 mA 8.1 A for 4 µs FL SWITCH SFNT 7TX/FX(-C) 175 mA 8.0 A for 31 µs FL SWITCH SFNT 7TX/FX ST(-C) 175 mA 8.0 A for 30 µs FL SWITCH SFNT 6TX/2FX(-C) 250 mA 11.6 A for 30 µs FL SWITCH SFNT 6TX/2FX ST(-C) 250 mA 10.8 A for 30 µs 2665_en_I PHOENIX CONTACT 3 FL SWITCH SFNT… Interfaces Total number of RJ45 Ethernet interfaces 4… 8 MAC Address Table Size (Entries) 2K Properties of RJ45 Ports Connection format 8-pos. RJ45 female connector on the switch Connection medium Twisted-pair cable with a conductor cross section of 0.14 mm2 to 0.22 mm2 Cable impedance 100 Ω Transmission speed 10/100 Mbps Maximum network segment length 100 m Properties of Fiber Optic Ports Connection format SC duplex or ST female connector Fiber type Multimode Laser protection Class 1 according to DIN EN 60825-1:2001-11 Transmission rate 100 Mbps full duplex Wavelength 1300/1310 nm Fiber optic segment length 12.1 km glass fiber with F-G 62.5/125 0.7 dB/km F1000 3.3 km glass fiber with F-G 62.5/125 2.6 dB/km F600 7.1 km glass fiber with F-G 50/125 0.7 dB/km F1200 3.1 km glass fiber with F-G 50/125 1.6 dB/km F800 Transmission power (medium type) dynamic (average) Minimum Maximum -23.5 dBm (50/125 µm) / -20 dBm (62.5/125 µm) -14 dBm (50/125 µm) / -14 dBm (62.5/125 µm) Transmission power (medium type) static Minimum Maximum -22.5 dBm (50/125 µm) / -19 dBm (62.5/125 µm) -14 dBm (50/125 µm) / -14 dBm (62.5/125 µm) Receiver sensitivity Minimum Maximum -31 dBm (dynamic) / -31 dBm (static) -14 dBm (dynamic) / -14 dBm (static) Alarm Contacts Voltage 24 V DC Current carrying capacity 100 mA maximum including inrush Mechanical Tests Shock test according to IEC 60068-2-27 Operation: 25g, 11 ms period, half-sine shock pulse Storage/transport: 50g, 11 ms period, half-sine shock pulse Vibration resistance according to IEC 60068-2-6 Operation/storage/transport: 5g, 150 Hz, Criterion 3 Free fall according to IEC 60068-2-32 1m Conformance With EMC Directives Developed according to IEC 61000-6-2 IEC 61000-4-2 (ESD) Contact: ±4 kV, Criterion B Air: ±8 kV, Criterion B IEC 61000-4-3 (radiated-noise immunity) 10 V/m, Criterion A IEC 61000-4-4 (burst) Ports: ±1 kV, Criterion B DC power: ±2 kV, Criterion B IEC 61000-4-5 (surge) Ports: ±1 kV, Criterion B DC power: ±500 V, Criterion B IEC 61000-4-6 (conducted noise immunity) 10 V/m, Criterion A IEC 61000-4-8 (noise immunity against magnetic fields) 30 A/m, Criterion A EN 55022 (noise emission) Class A 2665_en_I PHOENIX CONTACT 4 FL SWITCH SFNT… Conformance With Environmental and EMC Directives for Marine Applications1 Developed according to IEC 60945:2002 8.2 Dry Heat 8.3 Damp Heat (including test of insulation resistance) 8.4 Cold 8.7 Vibration 9 Electromagnetic emission 9.2 Conducted emission 9.3 Radiated emission 10.3 Immunity to conducted radio frequency 10.4 Immunity to radiated radio frequencies 10.5 Immunity to fast transients 10.6 Immunity to surges 10.7 Power supply variations 10.8 Power supply failure 10.9 Electrostatic discharge IEC 60945 Standard magnetic compass Safe compass distance Reduced safe distance 1.05 m 0.65 m IEC 60945 Steering magnetic compass Safe compass distance Reduced safe distance 1 0.60 m 0.40 m Excludes FL SWITCH SFNT…-C devices Approvals General c u ROHS EEE 2002/95/EC, WEEE 2002/96/EC Hazardous location1 U Class 1, Division 2, Groups A, B, C, D Temp Code T4 installed in minimum IP54 enclosure Marine1 2 Flxovm 1 Excludes FL SWITCH SFNT…-C devices 2 Excludes SFNT 6TX/2FX and SFNT 6TX/2FX ST devices 2665_en_I PHOENIX CONTACT 5 FL SWITCH SFNT… 5 5.2 Overview Power connector Power connector Data Transmission Speed LEDs (2 LEDs/Port) 10 Mbps 100 Mbps LNK/ACT ON/blinking ON/blinking 100 OFF ON Power LEDs (US) - green LNK/ACT LED: ON: indicates an electrical link FL SWITCH SFNT 4TX/FX Ord.No. 2891004 1 US 10 0 FL SWITCH SFNT 8TX Ord.No. 2891005 rm Ala 2 US 1 US K/ LN T AC 2 US 10 0 Flashing: indicates network traffic (at high data rates the blinking is in a constant rate) rm Ala K/ LN T AC K/ LN T AC 10 0 X1 X1 X2 6 10 0 K/ LN T AC / 10 0 K LN T AC Installation / K LN T AC 10 0 CAUTION: X2 X3 10 0 K/ LN T AC X4 / 10 X3 0 K LN T AC / K LN T AC 10 0 X5 10 0 K/ LN T AC X6 10 X4 0 K/ LN T AC K/ LN T AC 100 LED LNK/ACT 10 0 NOTE: Port X5 LNK/ACTLED Security Frame Figure 1 5.1 The FL SWITCH SFNT… module is designed for SELV and PELV operation according to IEC 61140/EN 61140. X8 X7 100 Only qualified personnel may start up and operate this device. Qualified personnel are persons authorized to start up, ground and mark devices, systems, and equipment according to the standards of safety technology. Power Connector, LED Locations and Security Frame Install the FL SWITCH SFNT… on a clean NS 35 rail. To avoid contact resistance use only clean, corrosion-free rails that meet the EN 60715 standard. End clamps can be mounted on both sides of the module to stop the modules from slipping on the rail. Diagnostic and Status Indicators Des. Color Status US1 and US2 green ON Supply voltage (US) in the tolerance range OFF Supply voltage (US) too low ON US1 or US2 is too low or missing Alarm red NOTE: Meaning Connect the mounting rail to protective earth ground using a grounding terminal block. The modules are grounded when they are snapped onto the rail. Connect protective earth ground with low impedance. 6.1 1. Port link failure OFF Normal operation 2. 3. 2665_en_I Assembly Place the module onto the rail from above. The upper holding keyway must be hooked onto the top edge of the rail. Push the module from the front towards the mounting surface. Once the module has been snapped on properly, check that it is fixed securely on the rail. PHOENIX CONTACT 6 FL SWITCH SFNT… 6.2 1. 2. 3. 6.3 Removal Insert a suitable tool (e.g., needle-nose pliers) into the arresting latch and pull it down. Pull the module slightly away from the mounting surface. Lift the module from the rail. Snapping the switch onto a grounded rail connects it to the ground potential. In an environment particularly prone to EMI, noise immunity can be increased by an additional lowimpedance connection to protective earth (see Figure 3). Mounting Plate The FL PA SFNT 5-8 mounting plate provides a method for mounting SFNT 5- and 8-port switches to a flat surface in any orientation. The plate can be mounted on either side of the switch to allow the network ports to face the proper direction. + – + – FL DA SFNT 5-8 adapter allows installation of the switch on a DIN rail with a low profile. The adapter also installs on either side of the switch. R2 U S 1 X 9 G N D U S 2 G N D R 1 R 2 US1 GND US2 GND R1 FL P Ord A SF Da .-No.: NT 5 -8 te Ma :14.02891 de 5.2 012 in T 01 aiw 0 an FL rm la A H ITC SW o. .N Odr 2 S U 1 S U SFN 91 28 T XS X/F T 7T 7 00 Figure 3 / K IN L T C A 0 / K IN L T C A 0 1 Power connections for redundant power supply X2 0 0 1 / K IN L T C A X1 0 / K IN L T C A 0 1 X4 0 0 1 / K IN L T C A X3 0 / K IN L T C A 0 1 X6 0 0 1 / K IN L T C A X5 0 / K IN L T C A 0 1 X8 0 0 1 X7 Figure 2 + – FL PA SFNT 5-8 Mounting Plate The dimensions of the FL PA SFNT 5-8 are shown in Figure 10. Additional information for the FL PA SFNT 5-8 can be found at www.phoenixcontact.net/catalog. 6.4 US1 GND US2 GND R1 R2 Power Connection The switch is designed for SELV and PELV operation at +24 V DC according to IEC 61140/EN 61140. Only SELV and PELV according to the defined standards may be used for supply purposes. 2665_en_I Figure 4 Power connections for single power supply PHOENIX CONTACT 7 FL SWITCH SFNT… Use power conductors between 0.2 - 2.5 mm² (24 - 12 AWG). Torque connection screws to 0.5 - 0.6 Nm (5 - 7 lb-in.). 6.5 Alarm Contact The FL SWITCH SFNT… switch provides contacts (R1, R2) for remote alarms if a failure is detected. Alarms are triggered if one or both power supplies fail. An alarm can be triggered if a port fails. Individual port alarms can be enabled via a DIP switch located on the bottom of the switch. 6.7 Fiber Optic Connection Two different types of fiber optic connection are available. The fiber optic connector(s) are located on the lower front face of the 8-port models or on the bottom face of the 5-port models. The ST connectors are typically individual round connectors and use a 1/4-turn connection. The SC connectors have a square interface and the “conductors” are typically locked together through the connector. The alarm relay is a normally closed type. When there are no faults, the contact is held open. When a fault occurs, the relay is de-energized to close the contact. The FL SWITCH SFNT 5... and FL SWITCH SFNT 4... use a five-position DIP switch. The FL SWITCH SFNT 8..., FL SWITCH SFNT 7... and FL SWITCH SFNT 6... use an eightposition DIP switch. Each DIP switch position corresponds to the port number. TD RD ON OFF Port O N 1 2 3 4 5 1 2 3 4 5 In addition to the remote alarm, failure is also indicated by the alarm LED On. Link Monitor Alarm To enable an alarm, move the appropriate slider to the ON position. Failure indication of a fiber optic port can be in either the RX or TX fiber. To disable an alarm, move the appropriate slider to the off position. DIN Rail clamp Figure 6 6.6 5-port fiber optic ports (SC connectors) Ethernet Interface The FL SWITCH SFNT… has five Ethernet ports on the front in RJ45 format to which only twisted-pair cables with an impedance of 100 Ω can be connected. The data transmission speed is 10/100 Mbps. In addition, every port has an auto crossing function: it is not necessary to make a distinction between 1:1 or crossover Ethernet cables. X5 X6 10 0 K/ LN T AC K/ LN T AC 10 X5 0 X6 10 TD K/ LN T AC K/ LN T AC 0 10 0 RD TD RD X7 RD RD RD X7 X8 RD TD TD Figure 7 X8 TD TD 8-Port ST fiber optic ports RJ45 X5 X6 10 0 K/ LN T AC K/ LN T AC 10 0 RD 2665_en_I K/ LN T AC 0 K/ LN T AC 10 0 RD X7 Figure 5 X6 10 TD 8 7 6 5 4 3 2 1 n.c. TDn.c. RDn.c. n.c. TD+ RD+ X5 Figure 8 RD X7 X8 X8 TD TD 8-port SC fiber optic ports RJ45 pin assignment PHOENIX CONTACT 8 FL SWITCH SFNT… 7 Switching Characteristics 8 Dimensions Store and Forward All data telegrams received by the switch are saved and their validity checked. Invalid or faulty data packets (> 1522 bytes or CRC errors) and fragments (< 64 bytes) are rejected. Valid data telegrams are forwarded by the switch. The switch always forwards the data using the data transmission speed that is used in the destination network segment. 14 mm FL SWITCH SFNT 4TX/FX Ord.No. 2891004 1 US 10 0 FL SWITCH SFNT 8TX Ord.No. 2891005 rm 2 US 1 US Ala K/ LN T AC 2 US 10 rm Ala 0 K/ LN T AC K/ LN T AC 10 0 X1 X1 10 0 K/ LN T AC X2 10 0 K/ LN T AC K/ LN T AC 10 0 Multi-Address Function The switch independently learns the addresses for termination devices, which are connected via a port, by evaluating the source addresses in the data telegrams. Only packets with unknown addresses, with a source address of this port or with a multicast/broadcast address in the destination address field are forwarded via the corresponding port. The switch can store addresses in its address table with an aging time of 5 minutes. This is important when more than one termination device is connected to one or more ports. In this way, several independent subnetworks can be connected to one switch. X3 10 0 130 mm X2 K/ LN T AC X3 X4 10 0 K/ LN T AC K/ LN T AC 10 0 X5 10 0 K/ LN T AC X6 10 X4 0 K/ LN T AC K/ LN T AC 10 X8 X7 100 LNK/ACT 0 Port X5 30 mm 50 mm A restart deletes the entire address table. Depth = 100 mm The FL SWITCH SFNT… switches are capable of reading Ethernet packets that have already been assigned a priority level by a managed switch. In cases of heavy traffic, packets with a priority level between 4 and 7 are considered high priority and processed before packets with a priority level between 0 and 3. After prioritization the packets are forwarded without modification. Figure 9 8.1 Housing dimensions FL PA SFNT 5-8 Mounting Plate 10.5 mm Quality of Service (QoS): IEEE 802.1P/Q Ø 5 mm 100.0 mm 130.0 mm 126.4 mm 140.0 mm Figure 10 2665_en_I FL PA SFNT 5-8 Dimensions PHOENIX CONTACT 9 FL SWITCH SFNT… 8.2 FL DA SFNT 5-8 Mounting Plate 115.4 mm 5.45 mm 104.5 mm 2665_en_I 100 mm 76.4 mm Figure 11 FL DA SFNT 5-8 Dimensions PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00 PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 www.phoenixcontact.com 10