(含更新表格單)\through\rb\rb13

SPECIFICATION FOR APPROVAL
REF. :
RB1314□□□□L□-□□□
ABC'S DWG NO.
PROD.
Radial Inductor
NAME
REV.
20130617-B
PAGE
1
Ⅰ﹒Configuration and dimensions:
F
101
Aψ
E
Wψ
C
Aψ
B
Marking :
" " : Start
Fig : A ( 3.3μH~47μH )
101----100 uH ( Inductance code )
":Start
C
Fig : B ( 68μH~15mH )
Aψ
11.70 ±0.8
F
B
Marking:‧101
"
101
Aψ
E
B
C
D
E
F
12.00 ±1.0
15.00 ±3.0
18.00 ±3.0
2.50 max.
9.00 ±1.0 (A)
7.00 ±0.8 (B)
Ⅱ﹒Description:
a﹒Ferrite drum core construction.
b﹒Enamelled copper wire:F class
c﹒Product weight: 4.60g(ref.)
d﹒Moisture sensitivity Level 1
e﹒Products comply with RoHS' requirements
f﹒Halogen free available
Ⅲ﹒General specification:
a﹒Storage temp.:-40℃ ~ +125℃
b﹒Operaing temp.:-40℃ ~ +125℃
( Temp. rise included. )
AR-001C
Wψ
D
Aψ
Unit:m/m
Wψ
Per spec. (A)
0.80
(B)
SPECIFICATION FOR APPROVAL
REF. :
RB1314□□□□L□-□□□
ABC'S DWG NO.
PROD.
Radial Inductor
NAME
REV.
20130617-B
PAGE
2
Ⅳ﹒Electrical characteristics:
SRF
( MHz )
typ.
59.00
RDC
(Ω)
max.
0.008
IDC
(A)
max.
5.600
7.96M
45.00
0.009
4.700
1K
7.96M
34.00
0.012
3.900
140
1K
2.52M
26.00
0.015
3.200
15.0 ±20%
120
1K
2.52M
19.00
0.019
2.600
RB1314220KL□-□□□
22.0 ±10%
110
1K
2.52M
14.00
0.026
2.200
RB1314330KL□-□□□
33.0 ±10%
100
1K
2.52M
10.00
0.045
1.800
RB1314470KL□-□□□
47.0 ±10%
90
1K
2.52M
8.30
0.056
1.500
RB1314680KL□-□□□
68.0 ±10%
80
1K
2.52M
6.70
0.092
1.200
RB1314101KL□-□□□
100.0 ±10%
70
1K
796K
5.40
0.120
1.000
RB1314151KL□-□□□
150.0 ±10%
70
1K
796K
4.30
0.200
0.820
RB1314221KL□-□□□
220.0 ±10%
40
1K
796K
3.40
0.250
0.680
RB1314331KL□-□□□
330.0 ±10%
40
1K
796K
2.70
0.420
0.550
RB1314471KL□-□□□
470.0 ±10%
30
1K
796K
2.30
0.510
0.460
RB1314681KL□-□□□
680.0 ±10%
30
1K
796K
1.90
0.790
0.380
RB1314102KL□-□□□
1000.0 ±10%
40
1K
252K
1.60
1.300
0.310
RB1314152KL□-□□□
1500.0 ±10%
30
1K
252K
1.30
1.700
0.250
RB1314222KL□-□□□
2200.0 ±10%
60
1K
252K
1.10
2.900
0.210
RB1314332KL□-□□□
3300.0 ±10%
50
1K
252K
0.90
3.700
0.170
RB1314472KL□-□□□
4700.0 ±10%
50
1K
252K
0.76
5.600
0.140
RB1314682KL□-□□□
6800.0 ±10%
60
1K
252K
0.65
9.400
0.120
RB1314103KL□-□□□
10000.0 ±10%
80
1K
79.6K
0.53
12.000
0.100
RB1314153KL□-□□□
15000.0 ±10%
70
1K
79.6K
0.41
15.000
0.082
Inductance
( μH )
Q
ref.
RB13143R3ML□-□□□
3.3 ±20%
90
RB13144R7ML□-□□□
4.7 ±20%
100
1K
RB13146R8ML□-□□□
6.8 ±20%
80
RB1314100ML□-□□□
10.0 ±20%
RB1314150ML□-□□□
DWG No.
Test Freq. ( Hz )
L
Q
1K
7.96M
1). Electrical specifications at 25℃
2). IDC base on Temp. rise 20℃ max.
3). Lead: 0.6ψ 〜 0.8ψ m/m soldered copper wire ( 3.3uH 〜 47uH )
Lead: 0.8ψ m/m tinned copper wire ( 68uH 〜 15mH )
AR-001C
Wψ
m/m
0.8
0.7
0.6
0.8
SPECIFICATION FOR APPROVAL
REF. :
RB1314□□□□L□-□□□
ABC'S DWG NO.
PROD.
Radial Inductor
NAME
REV.
20130617-B
PAGE
3
Ⅴ﹒Dwging number expression:
R
B
1
3
1
4
Reference code
Appendix code 2 : Package
Appendix code 1 : Classification
Tolerance code
Electrical code
Dimension code
Type code
Appendix code 1:Product Classification
L:Lead Free Standard products comply with RoHS' requirements
Appendix code 2:Package Information
Code
AR-001C
Inner package
Inner package Q'TY
Remark
A
Box
130
pcs
680K〜153K
B
Tray
280
pcs
3R3M〜470K( A type )
C
Box
150
pcs
3R3M〜470K
SPECIFICATION FOR APPROVAL
REF. :
RB1314□□□□L□-□□□
ABC'S DWG NO.
PROD.
Radial Inductor
NAME
REV.
20130617-B
PAGE
4
Ⅵ﹒Reliability test:
Item
1.High Temperature
Exposure
Reference documents
MIL-STD-202 Method 108
Test Condition
1.Temperature: 125℃
2.Time:96 hours.
1.Temperature: -40℃ ~ 125℃
2.Temperature Cycling JESD22 Method JA-104
2.Number of cycle:96 cycle
3.Dwell time:30 minutes
3.Biased Humidity Test MIL-STD-202 Method 103
1.Temperature: 85±5 ℃
2.Time:96 Hours
3.Humidity: 85±5% RH.
1.Temperature: 125℃
2.Time:96 hours.
3.Apply rated current.
4.Operational Life
MIL-PRF-27
5.Exeternal Visual
MIL-STD-883 Method 2009 constructions, marking and
Inspect product
workmanship.
Test Specification
1.No mechanical and electrical
damage.
2.Inductance shall not change
more than ±10%.
1.No mechanical and electrical
damage.
2.Inductance shall not change
more than ±10%.
1.No mechanical and electrical
damage.
2.Inductance shall not change
more than ±10%.
1.No mechanical and electrical
damage.
2.Inductance shall not change
more than ±10%.
1.No pollution on the surface of
products.
2.Clear marking.
3.No crack.
6.Physical Dimensions JESD22 Method JB-100
Verify physical dimensions to
the applicable product detail
specification.
Per product specification
standard
7.Resistance to solvents MIL-STD-202 Method 215
Immerse into solvent for 3±0.5 minutes &
brush 10 times for therr cycles.
1.No body change in apperarance.
2.No marking blurred.
3.Inductance shall not change
more than ±10%.
1.Frequency and Amplitued :
10-2000-10 Hz, 1.5 mm.
2.Direction:X, Y, Z
3.Test duration:2 hours for each direction,
6 hours in total.
1.Method:Dip
2.Temperature:260±5
3.Time(temp.≧ 260℃):10 second.
4.Number of times:3 times.
1.No mechanical and electrical
damage.
2.Inductance shall not change
more than ±10%.
8.Vibration Test
MIL-STD-202 Method 204
9.Resistance To
Soldering Heat Test
MIL-STD-202 Method 210
10.Rated current
MIL-STD-202 Method 330
11.Temperature rise
MIL-PRF-27
12.Over load
MIL-PRF-27
13.Solderability Test
J-STD-002
Dip pads in flux then dip in solder pot
at 240±5 for 5 senconds.
Teminals area must have 95% min.
Solder coverage.
14.Electrical
Characteriazation
User Spec.
1.Operating temperature: -40℃~125℃
2.Room temperature:25℃.
1.No mechanical and electrical
damage.
2.Inductance shall not change
more than ±10%.
15.Withstanding
Voltage Test
MIL-STD-202 Method 201
1.DV:500V
2.Time:1minutes
16.Drop
JESD22-B111
Packaged & Drop down from 1m.In 1 angle
1ridges & 2 surfaces orientation.
17.Terminal Strength
Test
JIS-C-6429
1.Apply push force to samples
mounted on PCB.
2.Force of 1.8 kg for 60±1 seconds.
AR-001C
1.No mechanical and electrical
damage.
2.Inductance shall not change
more than ±10%.
1.No mechanical and electrical
damage.
Apply rated current for 5 second.
2.Inductance shall not change
more than ±10%.
1.No mechanical and electrical
damage.
Apply rated current for 10 minutes.
2.Inductance shall not change
more than ±10%.
1.No mechanical and electrical
damage.
Apply twice as rated current for 5 minutes.
(It's not application to some special design) 2.Inductance shall not change
more than ±10%.
1.During the test no breakdown.
2.The characteristic is normal after test.
1.No case deformation or change in
appearance.
2.Inductance shall not change
more than ±10%.
After test, inductors shall be no