Low Current Side View Chip LED (16115) SMLA12BC7T z Usage Source of light for display unit. z Dimensions (Unit : mm) z Recommended pad layout (Unit:mm) 1.6 1.2 1.2 3.3 1.15 0.68 0.9 0.55 z Features 1) Side-view type 2) Low current blue LED PCB Bonding Direction z Construction InGaN on SiC Terminal 1.1 Cathode Cathode mark (note) Tolerance is within ±0.1 unless otherwise specified. Anode z Circuit diagram z Taping specifications (Unit : mm) +0.1 4.0±0.1 1.85 0~0.5 1.35 5.5 3.5±0.05 φ1.5 -0 2.0±0.05 8.0 1.75±0.1 (T86) 0.7 (note) Tolerance is within ±0.2mm unless otherwise specified. z Absolute maximum ratings (Ta=25°C) Parameter Symbol Power dissipation Forward current Peak forward current Reverse voltage Operating temperature Storage temperature PD IF IFP VR Topr Tstg -30 -40 z Luminous classification(Ta=25°C, lF=5mA) Limits 66 20 100 5 to to +85 °C +100 °C *1 Duty1/10 1kHz z Electrical-Optical characteristics (Ta=25°C) Parameter Symbol Min. Forward voltage Reverse current Luminous intensity Dominant wavelength * 3 VF IR IV λD Typ. 2.9 16 470 5.6 465 *2 www.rohm.com ©2009 ROHM Co., Ltd. All rights reserved. Luminous classification range Symbol L 5.6 to 9.0 mcd M 9.0 to 14 mcd N 14 to 22 mcd P 22 to 36 mcd Measurement tolerance : ±10% Unit mW mA mA *1 V Max. 3.3 100 36 475 Pulse width : 30ms 1/2 Conditions Unit V µA mcd nm IF=5mA *2 VR=5V IF=5mA *2 IF=5mA *2 *3 Measurement tolerance : ±1nm 2009.07 - Rev.A SMLA12BC7T X-Y SCANNING ANGLE(deg) 0 30 30 60 90 100 30 50 30 60 90 0 SCANNING ANGLE(deg) 0 X'-Y' 60 50 Data Sheet 100 90 100 60 50 0 50 90 100 RELATIVE BRIGHTNESS (%) RELATIVE BRIGHTNESS (%) DIRECTIVITY www.rohm.com ©2009 ROHM Co., Ltd. All rights reserved. 2/2 2009.07 - Rev.A Notice Notes No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. Great care was taken in ensuring the accuracy of the information specified in this document. However, should you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices). The Products specified in this document are not designed to be radiation tolerant. While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuel-controller or other safety device). ROHM shall bear no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing. If you intend to export or ship overseas any Product or technology specified herein that may be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law. Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us. ROHM Customer Support System http://www.rohm.com/contact/ www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. R0039A