Download Data Sheet

DTEPU40A SERIES
Up to 40 Watts
AC/DC Desktop Power Supplies
Single Output
Rev A
Size: 4.21in x 1.85in x 1.19in (107mm x 47mm x 30mm)
OPTIONS
FEATURES
• Output Connector
• Output Voltage
• Wide Operating Voltage of
90~264VAC
• IEC-320-C14 Input Inlet
• Optional Output Connectors
Available
• Single Outputs
APPLICATIONS
•
•
•
•
•
•
•
•
•
•
•
•
Class I System
Energy Efficiency Level VI
RoHS Compliant
Over Current and Short Circuit Protection
High Efficiency of 84~90%
1 Year Warranty
DESCRIPTION
Ethernet Hub
Portable Devices
Charger
Monitor
Set-top Box
AV Equipment
The DTEPU40A series of AC DC desktop power supplies offers up to 40 watts of output power in a 4.2” x
1.85” x 1.19” package. This series offers single output models with output voltages ranging from 5~48VDC
and a wide input voltage range of 90~264VAC. Each model is both Energy Efficiency Level VI and RoHS
compliant and has high efficiency of 84~90%. Each model is also protected against both over current and
short circuit conditions and has UL/c-UL (UL 60950-1:2nd Edition) and TUV/GS (EN60950-1:2nd Edition)
safety approvals.
MODEL SELECTION TABLE
Model Number(1)
DTEPU40A-102
DTEPU40A-103
DTEPU40A-104
DTEPU40A-105
DTEPU40A-106
DTEPU40A-107
DTEPU40A-108
DTEPU40A-109
DTEPU40A-110
DTEPU40A-111
12/18/2015
Input Voltage
Range
Output
Voltage
Output Current
90~264VAC
5~5.99VDC
6.5~8VDC
8~11VDC
11~13VDC
13~16VDC
16~21VDC
21~27VDC
27~33VDC
33~40VDC
40~48VDC
5.00A
3.75~4.61A
3.18~4.38A
3.07~3.64A
2.50~3.07A
1.90~2.50A
1.48~1.90A
1.21~1.48A
1.00~1.21A
0.83~1.00A
Ripple &
Noise(7)
100mVp-p
No Load
Power Consumption
Output
Power
Total Regulation
Efficiency
0.1 Watts
30W
30W
35W
40W
40W
40W
40W
40W
40W
40W
±5%
±5%
±5%
±5%
±5%
±5%
±3%
±3%
±2%
±2%
89~95%
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 1 of 4
DTEPU40A SERIES
Up to 40 Watts
AC/DC Desktop Power Supplies
Single Output
Rev A
SPECIFICATIONS
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Safety Approvals Input Voltage Range
Operate Voltage Range
Sine Wave
Io=Full Load, Vin=100VAC
Io=Full Load, Vin=240VAC
Io=Full Load, 25°C, Cool Start, Vin=115VAC
Io=Full Load, 25°C, Cool Start, Vin=230VAC
100
90
47
Full Load, Vin=100VAC
Vin=230VAC, 10~90% Load Change at Condition
0.5
4
Typ
Max
Unit
INPUT SPECIFICATIONS
Input Voltage Range
Input Frequency
Low Line
Input Current
High Line
Low Line
Inrush Current
High Line
OUTPUT SPECIFICATIONS
Output Voltage
Line Regulation(5)
Load Regulation(6)
Output Power
Output Current
Ripple & Noise (20MHz BW)(7)
Hold-Up Time(8)
Start-Up Time
Temperature Coefficient
No Load Power Consumption
PROTECTION
Over Load Protection
Short Circuit Protection
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Electro Static Discharge
Operating Altitude (Elevation)
Vibration
Surge Voltage
MTBF
Cooling
Flammability Rating
GENERAL SPECIFICATIONS
Efficiency(9)
Dielectric Withstanding Voltage
Isolation Resistance
Safety Ground Leakage Current
PHYSICAL SPECIFICATIONS
Weight
240
264
63
0.9
0.52
50
100
40
80
VAC
Hz
A
A
See Table
1
5
%
%
3
±0.04
0.1
mVp-p
mS
S
%/°C
W
See Table
See Table
100
Rated Load and Nominal Line
Io=Full Load, Vin=110VAC
Io=Full Load, Vin=100VAC
All Outputs
No Load, Vin=230VAC
8
Recovers automatically after fault condition is removed
110
Derate linearly from 100% load at 40ºC to 50% load at 70ºC
10~95% RH
Non-condensing
0
-40
0
0
Air Discharge, IEC61000-4-5
Contact Discharge, IEC61000-4-2
All conditions
10~500Hz, 10min./1cycle, 60min. each along X, Y, Z axes
Line-Neutral
Line-PE & Neutral-PE
Operating Temperature at 25ºC, calculated per MIL-HDBK-217F
150
Automatic Recovery
%
°C
°C
%RH
%RH
70
85
95
95
8
6
3000
5
1
2
kV
M
G
kV
100,000
hours
Free Air Convection
UL94V-1
Io=Full Load, Vin=230VAC
Primary to Secondary
Primary to PE
Test Voltage=500VDC
Vin=240VAC/60Hz
84
4242
2550
50
90
%
VDC
MΩ
mA
0.75
9.35-9.88oz (265-280g)
4.21in x 1.85in x 1.19in
(107mm x 47mm x 30mm)
Dimensions (L x W x H)
SAFETY & EMC CHARACTERISTICS
Safety Approvals(2)
EMC Emission
Protection Classes
12/18/2015
UL/c-UL (UL 60950-1: 2nd Edition)
TUV/GS (EN 60950-1: 2nd Edition)
Compliance to EN55022 (CISPR22)
Class I
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
B Class
Page 2 of 4
Rev A
DTEPU40A SERIES
Up to 40 Watts
AC/DC Desktop Power Supplies
Single Output
NOTES
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
DTEPU40A-102-104 are required to use AWG#14/4FT output cable.
DTEPU40A-105-110 are required to use AWG#18/4FT output cable.
DTEPU40A-111 is required to use AWG#20/4FT output cable.
The electrical characteristics will be changed by modified output cable.
The DTEPU40A-102 is available on NRCan mark
Output can provide up to peak load when the power supply starts up. Staying in more than rated load continuously is not allowed.
Each output is checked to be within voltage accuracy in 60% rated load condition.
Line regulation is defined by changing ±10% of input voltage from nominal line at rated load.
Load regulation is defined by changing ±40% of measured output load from 60% rated load.
Ripple & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.47uF capacitor at rated load and
nominal line.
Hold up time is measured from end of the last charging pulse to the time which the main output drops down to low limit of main output at rated
load and nominal line.
Efficiency measured at rated load and nominal line.
DERATING CURVES
Input Voltage Derating Curve
Temperature Derating Curve
12/18/2015
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 3 of 4
Rev A
DTEPU40A SERIES
Up to 40 Watts
AC/DC Desktop Power Supplies
Single Output
MECHANICAL DRAWINGS
Mechanical Specification
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development
engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008
certification is just one example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely
with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide
ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your
future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
12/18/2015
(603)778-2300
(888)597-9255
(603)778-9797
[email protected]
www.wallindustries.com
37 Industrial Drive
Exeter, NH 03833
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 4 of 4