Download Data Sheet

PSMBU123 SERIES
125 Watts
AC/DC Medical Open Frame Power Supply
Dual Output
Rev A
FEATURES
• Wide Operating Voltage, 90 to 260VAC,
47 to 63Hz
• Dual Output (5V Standby Output)
• Remote On/Off Control
• Surge ±3kV
• Class I
APPLICATIONS
Size: 6.00in x 3.50in x 1.46in
(152.40mm x 88.90mm x 37mm)
• Medical Equipment
• Patient Monitor
• Blood Pressure
System
• Portable Medical
Devices
• ECG Machine
•
•
•
•
•
Meets Medical Safety 3rd Edition
Input to Output: 2MOPP
Active Power Factor Correction
Short Circuit and Over Load Protection
ANSI/AAMI ES 60601-1:2005 (UL/cUL 3rd
Edition) Safety Approvals
DESCRIPTION
The PSMBU123 series of AC DC open frame medical power
supplies offers up to 125 watts of output power in a 6” x 3.50” x
1.46” unit. This series consists of dual output models and a wide
operating voltage of 90 to 260VAC. Each model has active power
factor correction, meets medical safety 3rd edition approvals, and
has short circuit and over load protection. This series has
ANSI/AAMI ES 60601-1:2005 (UL/cUL 3rd Edition) safety approvals.
MODEL SELECTION TABLE
Input Voltage
Range
Model Number
PSMBU123-105
PSMBU123-107
PSMBU123-108
PSMBU123-110
PSMBU123-111
90~260VAC
Output Voltage
Vo1
Vsb
12VDC 5VDC
19VDC 5VDC
24VDC 5VDC
36VDC 5VDC
48VDC 5VDC
Output Current
Io1
Isb
9.00A
3.0A
5.68A
3.0A
4.58A
3.0A
3.05A
3.0A
2.29A
3.0A
Ripple & Noise
100mVp-p
150mVp-p
200mVp-p
200mVp-p
200mVp-p
No Load
Consumption
0.5W
0.5W
0.5W
0.5W
0.5W
Output
Power
123W
123W
125W
125W
125W
Total Regulation
Efficiency
±3%
±3%
±3%
±3%
±3%
88%
88%
88%
88%
88%
SPECIFICATIONS
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
INPUT SPECIFICATIONS
Operate Input Voltage Range
Safety Approval Input Voltage Range
Input Frequency
Power Factor Correction
Inrush Current
OUTPUT SPECIFICATIONS
Output Voltage
Line Regulation(3)
Total Regulation(4)
Output Power
Output Current
Ripple & Noise (20MHz bandwidth)(5)
Transient Response Time
Start-Up Time
Hold-Up Time(6)
Temperature Coefficient
PROTECTION
Short Circuit Protection
Over Load Protection
ENVIRONMENTAL SPECIFICATIONS
Operating Case Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Surge Voltage
Operating Altitude
Vibration
Cooling
MTBF
4/27/2016
Typ
90
100
47
0.95
Sine Wave
Low Line
High Line
Low Line
High Line
Input Current
Min
Full Load, Vin=100VAC
Full Load, Vin=240VAC
Full Load, 25ºC, Cool Start, Vin=100VAC
Full Load, 25ºC, Cool Start, Vin=240VAC
Full Load, Vin=100~120VAC or 200~240VAC
-3
Full Load, Vin=110VAC
Full Load, Vin=100~240VAC
Full Load, Vin=100VAC
All Conditions
110
Derate linearly from 100% load at 50ºC to 50% load at 70ºC
10~95% RH
Non-Condensing
-10
-40
0
0
All Conditions
All Conditions
10~500Hz, 10min./1cycle, 60min. each along X, Y, Z axes
Unit
260
240
63
0.99
1.7
1.0
35
65
VAC
VAC
Hz
See Table
1
+3
See Table
See Table
See Table
4
1.5
50
-0.04
Recovers automatically after fault conditions is removed
Max
+0.04
Automatic Recovery
150
70
85
95
95
2
3000
5
A
A
%
%
ms
s
ms
%/ºC
%
ºC
ºC
%RH
%RH
kV
m
G
Free Air Convection
Operating Temperature at 25ºC, Calculated per MIL-HDBK-217F
100,000
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Hours
Page 1 of 3
Rev A
PSMBU123 SERIES
125 Watts
AC/DC Medical Open Frame Power Supply
Dual Output
SPECIFICATIONS
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
GENERAL SPECIFICATIONS
Efficiency(7)
Insulation Resistance
Dielectric Withstanding Voltage (P-S)
Dielectric Withstanding Voltage (P-G)
Safety Ground Leakage Current
PHYSICAL SPECIFICATIONS
Weight
Min
Full Load, Vin=230VAC
Primary to Secondary, 500VDC, 25ºC/70% RH
Primary to Secondary, limit current <10mA
Primary to PE, limit current <10mA
Vin=240VAC, 60Hz
Max
Unit
See Table
50
4000
1500
0.1
MΩ
VAC
VAC
mA
19.40oz (550g)
6.00in x 3.50in x 1.46in
(152.40mm x 88.90mm x 37.00mm)
Mates with Molex housing 09-52-4104 and
Molex2478 series crimp terminal
Mates with Molex housing 09-52-4034 and
Molex 2478 series crimp terminal
UL94V-1
Dimensions (L x W x H)
Input Connector
Output Connector
Flammability Rating
SAFETY CHARACTERISTICS
Safety Approvals
EMC Emission
Class of Equipment
Flammability Rating
Typ
ANSI/AAMI ES 60601-1:2005 (UL/cUL 3rd Edition)
EN55011 (CISPR11), EN61000-3-2, -3
Class B
Class I
UL94V-1
NOTES
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Output can provide up to peak load when the power supply starts up. Staying in more than rated load continuously is not allowed.
Each output is checked to be within voltage accuracy at factory at 60% load condition.
Line regulation is defined by changing ±10% of input voltage from nominal line at rated load.
Load regulation is defined by changing ±40% of measured output load from 60% rated load.
Ripple & noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.47uF capacitor atrated load and
nominal line.
Hold up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at rated
load and nominal line.
Efficiency is measured at rated load, and nominal line.
Remote control connector mates with Molex housing
DERATING CURVES
Input Voltage Derating Curve
4/27/2016
Temperature Derating Curve
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 2 of 3
PSMBU123 SERIES
125 Watts
AC/DC Medical Open Frame Power Supply
Dual Output
Rev A
MECHANICAL DRAWINGS
PIN CHART
PSMBU123-1XX Pin 2
1
2
Vsb (+5VDC)
Remote On/Off
1
Remote
On/Off
2
Vsb
(+5VDC)
3
COM
PSMBU123-1XX Pin 3
4
5
6
COM
COM
COM
7
8
9
10
Vo1
Vo1
Vo1
Vo1
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development
engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008
certification is just one example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely
with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide
ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your
future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
4/27/2016
(603)778-2300
(888)597-9255
(603)778-9797
[email protected]
www.wallindustries.com
37 Industrial Drive
Exeter, NH 03833
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 3 of 3