PSMBU123 SERIES 125 Watts AC/DC Medical Open Frame Power Supply Dual Output Rev A FEATURES • Wide Operating Voltage, 90 to 260VAC, 47 to 63Hz • Dual Output (5V Standby Output) • Remote On/Off Control • Surge ±3kV • Class I APPLICATIONS Size: 6.00in x 3.50in x 1.46in (152.40mm x 88.90mm x 37mm) • Medical Equipment • Patient Monitor • Blood Pressure System • Portable Medical Devices • ECG Machine • • • • • Meets Medical Safety 3rd Edition Input to Output: 2MOPP Active Power Factor Correction Short Circuit and Over Load Protection ANSI/AAMI ES 60601-1:2005 (UL/cUL 3rd Edition) Safety Approvals DESCRIPTION The PSMBU123 series of AC DC open frame medical power supplies offers up to 125 watts of output power in a 6” x 3.50” x 1.46” unit. This series consists of dual output models and a wide operating voltage of 90 to 260VAC. Each model has active power factor correction, meets medical safety 3rd edition approvals, and has short circuit and over load protection. This series has ANSI/AAMI ES 60601-1:2005 (UL/cUL 3rd Edition) safety approvals. MODEL SELECTION TABLE Input Voltage Range Model Number PSMBU123-105 PSMBU123-107 PSMBU123-108 PSMBU123-110 PSMBU123-111 90~260VAC Output Voltage Vo1 Vsb 12VDC 5VDC 19VDC 5VDC 24VDC 5VDC 36VDC 5VDC 48VDC 5VDC Output Current Io1 Isb 9.00A 3.0A 5.68A 3.0A 4.58A 3.0A 3.05A 3.0A 2.29A 3.0A Ripple & Noise 100mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p No Load Consumption 0.5W 0.5W 0.5W 0.5W 0.5W Output Power 123W 123W 125W 125W 125W Total Regulation Efficiency ±3% ±3% ±3% ±3% ±3% 88% 88% 88% 88% 88% SPECIFICATIONS All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS INPUT SPECIFICATIONS Operate Input Voltage Range Safety Approval Input Voltage Range Input Frequency Power Factor Correction Inrush Current OUTPUT SPECIFICATIONS Output Voltage Line Regulation(3) Total Regulation(4) Output Power Output Current Ripple & Noise (20MHz bandwidth)(5) Transient Response Time Start-Up Time Hold-Up Time(6) Temperature Coefficient PROTECTION Short Circuit Protection Over Load Protection ENVIRONMENTAL SPECIFICATIONS Operating Case Temperature Storage Temperature Operating Humidity Storage Humidity Surge Voltage Operating Altitude Vibration Cooling MTBF 4/27/2016 Typ 90 100 47 0.95 Sine Wave Low Line High Line Low Line High Line Input Current Min Full Load, Vin=100VAC Full Load, Vin=240VAC Full Load, 25ºC, Cool Start, Vin=100VAC Full Load, 25ºC, Cool Start, Vin=240VAC Full Load, Vin=100~120VAC or 200~240VAC -3 Full Load, Vin=110VAC Full Load, Vin=100~240VAC Full Load, Vin=100VAC All Conditions 110 Derate linearly from 100% load at 50ºC to 50% load at 70ºC 10~95% RH Non-Condensing -10 -40 0 0 All Conditions All Conditions 10~500Hz, 10min./1cycle, 60min. each along X, Y, Z axes Unit 260 240 63 0.99 1.7 1.0 35 65 VAC VAC Hz See Table 1 +3 See Table See Table See Table 4 1.5 50 -0.04 Recovers automatically after fault conditions is removed Max +0.04 Automatic Recovery 150 70 85 95 95 2 3000 5 A A % % ms s ms %/ºC % ºC ºC %RH %RH kV m G Free Air Convection Operating Temperature at 25ºC, Calculated per MIL-HDBK-217F 100,000 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Hours Page 1 of 3 Rev A PSMBU123 SERIES 125 Watts AC/DC Medical Open Frame Power Supply Dual Output SPECIFICATIONS All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS GENERAL SPECIFICATIONS Efficiency(7) Insulation Resistance Dielectric Withstanding Voltage (P-S) Dielectric Withstanding Voltage (P-G) Safety Ground Leakage Current PHYSICAL SPECIFICATIONS Weight Min Full Load, Vin=230VAC Primary to Secondary, 500VDC, 25ºC/70% RH Primary to Secondary, limit current <10mA Primary to PE, limit current <10mA Vin=240VAC, 60Hz Max Unit See Table 50 4000 1500 0.1 MΩ VAC VAC mA 19.40oz (550g) 6.00in x 3.50in x 1.46in (152.40mm x 88.90mm x 37.00mm) Mates with Molex housing 09-52-4104 and Molex2478 series crimp terminal Mates with Molex housing 09-52-4034 and Molex 2478 series crimp terminal UL94V-1 Dimensions (L x W x H) Input Connector Output Connector Flammability Rating SAFETY CHARACTERISTICS Safety Approvals EMC Emission Class of Equipment Flammability Rating Typ ANSI/AAMI ES 60601-1:2005 (UL/cUL 3rd Edition) EN55011 (CISPR11), EN61000-3-2, -3 Class B Class I UL94V-1 NOTES (1) (2) (3) (4) (5) (6) (7) (8) Output can provide up to peak load when the power supply starts up. Staying in more than rated load continuously is not allowed. Each output is checked to be within voltage accuracy at factory at 60% load condition. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. Load regulation is defined by changing ±40% of measured output load from 60% rated load. Ripple & noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.47uF capacitor atrated load and nominal line. Hold up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at rated load and nominal line. Efficiency is measured at rated load, and nominal line. Remote control connector mates with Molex housing DERATING CURVES Input Voltage Derating Curve 4/27/2016 Temperature Derating Curve Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 2 of 3 PSMBU123 SERIES 125 Watts AC/DC Medical Open Frame Power Supply Dual Output Rev A MECHANICAL DRAWINGS PIN CHART PSMBU123-1XX Pin 2 1 2 Vsb (+5VDC) Remote On/Off 1 Remote On/Off 2 Vsb (+5VDC) 3 COM PSMBU123-1XX Pin 3 4 5 6 COM COM COM 7 8 9 10 Vo1 Vo1 Vo1 Vo1 COMPANY INFORMATION Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, well-documented product for our customers. Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects. Contact Wall Industries for further information: Phone: Toll Free: Fax: E-mail: Web: Address: 4/27/2016 (603)778-2300 (888)597-9255 (603)778-9797 [email protected] www.wallindustries.com 37 Industrial Drive Exeter, NH 03833 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 3 of 3