-È '" ffi CERTIFICATE (1) EG-TypeExam¡nation (2) Equipmentand protectivesystems intendedfor use in potentiallyexplosiveatmospheres- Directive94/9/EG Y (3) EC-Type Examination Certificate Number: KEMA034TEX1447 X (4) Equipment ô (5) Manufacturer: Magnetrol International N.V. (6) Address: (7) This equipment and any acceptable variation thereto is sp.ecifìedin É, t¡l A '...., . lssueNumber:2 RadarLevelTransmitter ModelPulsarRxS Heikensstraat 6, 9240 Zele, Belgium documents thereinreferredto. (8) DEKRA Certification8.V., notifiedbody number 0344 in of 23 March1994,certifiesthat this equipmenthas Requirementsrelating to the design and potentiallyexplosiveatmospheresgiven in Theexamination andtestresultsare (e) Compliancewith the Essential EN60079-0: 2009 (10) lf the sign "X" is placed for safe use specified (11) ThisEC-Type E accordingto the supplyof this (12) The markingof ffi Page,112 @ Integralpublicationof this certif¡cateand adjoining reports is allowed. This Certiflcatemay only be reproducedin ¡ts entirety and without any change ñ PRÛI|JITS HvAt 001 All testing,inspection, auditingand certification activitiesof the formerKEMAQualityare an integralparl of the DEKRACertÍfication Group DEKRACertification B.V. Utrechtseweg 3'l0, 6812AR Arnhem P.O.Box5185,6802ED Arnhem The Netherlands T+31 26 3562000 F+31 263525800 www.dekra-certification.com RegísteredArnhem09085396 (13) SCHEDULE :I (14) to EC-TypeExamination GertificateKEMA 03ATEX1447X (15) Description lssue No. 2 ModelPulsarRxSmeasuresthe levelof the fluidusinga microwave The RadarLevelTransmitter (HART). beam.Theoutputsignalis a 4 - 20 mA currentsignalwithdigitalcommunication The antennais a hornor a dielectricrodtype. is providedwitha displayfor localread-outand configuration. The transmitter The transmitter enclosureprovidesa degreeof protectionlP66as per EN 60529. Ambienttemperature range40'C to +70"C. Electricaldata + and-): OutpuVsupply circuit(terminals in typeof protectionintrinsicsafetyEx ia llG,onlyfor connection to a certifiedintrinsically safe maximum values: circuit,withthefollowing Ui= 28,4Vi l¡= 129mA;P¡= 0,84W; C¡= 2,2 nF;L¡= 430pH. (16) Test Report NUDEI(ExTRl1.0026/**. (17) Specialconditionsfor safe use if ModelPulsarRxSis madeof aluminium, Becausethe enclosure of the RadarLevelTransmitter it is mountedin an areawherethe useof category1 G apparatusis required,it mustbe installed ì such,that,even in the eventof rare incidents,ignitionsourcesdue to impactand frictionsparks are excluded. discharges are prevented. Thetransmitter's antennashallbe installedso, thatelectrostatic (18) EssentialHealthand SafetyRequirements Coveredby the standardslistedat (9). (19) Testdocumentation As listedin TestReportNUDEI(ExTR11.0026/**. Page2l2 Form 100 Version 1 (2010-12)