Pulsar Ex ia

-È
'"
ffi
CERTIFICATE
(1)
EG-TypeExam¡nation
(2)
Equipmentand protectivesystems intendedfor use in
potentiallyexplosiveatmospheres- Directive94/9/EG
Y
(3)
EC-Type
Examination
Certificate
Number:
KEMA034TEX1447
X
(4)
Equipment
ô
(5)
Manufacturer: Magnetrol International N.V.
(6)
Address:
(7)
This equipment and any acceptable variation thereto is sp.ecifìedin
É,
t¡l
A
'...., .
lssueNumber:2
RadarLevelTransmitter
ModelPulsarRxS
Heikensstraat 6, 9240 Zele, Belgium
documents
thereinreferredto.
(8)
DEKRA Certification8.V., notifiedbody number 0344 in
of 23 March1994,certifiesthat this equipmenthas
Requirementsrelating to the design and
potentiallyexplosiveatmospheresgiven in
Theexamination
andtestresultsare
(e)
Compliancewith the Essential
EN60079-0: 2009
(10)
lf the sign "X" is placed
for safe use specified
(11)
ThisEC-Type
E
accordingto the
supplyof this
(12)
The markingof
ffi
Page,112
@
Integralpublicationof this certif¡cateand adjoining reports is allowed. This Certiflcatemay only be reproducedin ¡ts entirety and without any change
ñ
PRÛI|JITS
HvAt
001
All testing,inspection,
auditingand certification
activitiesof the formerKEMAQualityare an integralparl
of the DEKRACertÍfication
Group
DEKRACertification
B.V. Utrechtseweg
3'l0, 6812AR Arnhem P.O.Box5185,6802ED Arnhem The Netherlands
T+31 26 3562000 F+31 263525800 www.dekra-certification.com
RegísteredArnhem09085396
(13) SCHEDULE
:I
(14)
to EC-TypeExamination GertificateKEMA 03ATEX1447X
(15)
Description
lssue No. 2
ModelPulsarRxSmeasuresthe levelof the fluidusinga microwave
The RadarLevelTransmitter
(HART).
beam.Theoutputsignalis a 4 - 20 mA currentsignalwithdigitalcommunication
The antennais a hornor a dielectricrodtype.
is providedwitha displayfor localread-outand configuration.
The transmitter
The transmitter
enclosureprovidesa degreeof protectionlP66as per EN 60529.
Ambienttemperature
range40'C to +70"C.
Electricaldata
+ and-):
OutpuVsupply
circuit(terminals
in typeof protectionintrinsicsafetyEx ia llG,onlyfor connection
to a certifiedintrinsically
safe
maximum
values:
circuit,withthefollowing
Ui= 28,4Vi l¡= 129mA;P¡= 0,84W; C¡= 2,2 nF;L¡= 430pH.
(16)
Test Report
NUDEI(ExTRl1.0026/**.
(17)
Specialconditionsfor safe use
if
ModelPulsarRxSis madeof aluminium,
Becausethe enclosure
of the RadarLevelTransmitter
it is mountedin an areawherethe useof category1 G apparatusis required,it mustbe installed ì
such,that,even in the eventof rare incidents,ignitionsourcesdue to impactand frictionsparks
are excluded.
discharges
are prevented.
Thetransmitter's
antennashallbe installedso, thatelectrostatic
(18)
EssentialHealthand SafetyRequirements
Coveredby the standardslistedat (9).
(19)
Testdocumentation
As listedin TestReportNUDEI(ExTR11.0026/**.
Page2l2
Form 100
Version 1 (2010-12)