GFCI / ELCI Circuit Protection SELECTOR GUIDE PB-Series PC-Series POLES 1-3 poles, 3rd pole switched neutral 1-poles (1 circuit breaker + 1 GFCI sensor module), 120V, 2-pole (2 circuit breakers + 1 GFCI sensor module), 120/240V, or 120V with neutral break 2-pole (2 circuit breakers + 1 GFCI sensor module), 240VAC, 3-pole 120/240V with neutral break (sensor module has 2 pole width) ACTUATOR STYLE handle, rocker, flat rocker handle, rocker, flat rocker, push-to-reset LEAKAGE CURRENT TRIP LEVEL 30mA & 6mA 30mA & 6mA For 30mA leakage trip: ≤ 22.2mA, shall not trip 30mA, shall trip within .10 seconds, complying with UL-1053 & ABYC E11. For 30mA leakage trip: ≤ 22.2mA, shall not trip 30mA, shall trip within .10 seconds, complying with UL-1053 & ABYC E11. For 6mA leakage trip: ≤25ms For 6mA leakage trip: ≤25ms MAX CURRENT & VOLTAGE RATINGS 0.10 - 30 amps @ 120/240VAC 0.10 - 50 amps @ 120/240VAC - 240VAC MAX INTERRUPTING CAPACITY 5,000A 5,000A AVAILABLE CIRCUITS series trip series trip TERMINATION .250” tabs, 8-32, 10-32, M4,M5 screw with upturned lugs, 8-32, 10-32, M4,M5 screw, bus type 10-32 threaded stud MOUNTING METHOD front panel front panel OPERATING TEMPERATURE -35° C to +65° C -35° C to +65° C APPROVALS UL 489, UL 1077, UL 1500 CSA Approved, UL 1053, UL 1500 LEAKAGE CURRENT TRIP TIME *Manufacturer reserves the right to change product information without prior notice GFCI-SG_12_2015 60 Johnson Avenue | Plainville, CT 06062 | Phone: (860) 793-9281 | Fax: (860) 793-9231 | Web: www.carlingtech.com