PC-Series - Carling Technologies Product Information

PC-Series
GFCI/ELCI & Panel Seal
The PC-Series, AC Residual Current Circuit Breaker with
Overcurrent Protection (RCBO), combines the ground fault
protection of a GFCI with the familiar overcurrent tripping
characteristics of a normal circuit breaker.
The PC-series utilizes the hydraulic magnetic principle
which provides precise operation and performance even
when exposed to extremely hot and/or cold application
environments.
Features:
ŠŠ Overload, short circuit and ground fault protection in a single package
ŠŠ Handle style actuators and rocker style “acuguard”
ŠŠ Wiping Contacts - Mechanical linkage with two-step actuation – cleans contacts, provides high, positive contact pressure & longer contact life
ŠŠ A trip-free mechanism, a safety feature which makes it impossible to manually hold the contacts closed during overload or fault conditions.
ŠŠ A common trip linkage between all poles, another safety
feature, ensures that an overload in one pole will trip all adjacent poles.
ŠŠ Front panel mounting
ŠŠ Integral push-to-test button
ŠŠ Two integrated LED indicators distinguish if a breaker is closed with Line Voltage present, or has opened due to leakage current, or has opened due to over current, or is closed with no Line Voltage present.
ŠŠ Optional Hot/Neutral reversal detection and protection
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062-1177
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
Benefits:
ŠŠ Increases safety around boats and marinas
ŠŠ Protects against electrical shock hazards in areas near water
ŠŠ Protects against defects in the wires & conductors
ŠŠ Reduces fire and shock hazards from defects in permanently
installed appliances such as water heaters, battery chargers,
lighting fixtures, etc.
ŠŠ Detects low level ground faults, which do not trip ordinary
circuit breakers, that can lead to fires and shock hazards for
boating occupants
2 | PC-Series Circuit Breaker - General Specifications
Electrical Tables
Table A: Lists UL Listed configurations as a Ground Fault Circuit
Interruptor
TABLE A : LISTS UL LISTED CONFIGURATIONS AS A GROUND FAULT CIRCUIT INTERRUPTOR
CURRENT SHORT CIRCUIT
RATING
CAPACITY
VOLTAGE
CIRCUIT
CONFIGURATION
MAX.
RATING
SERIES
FREQUENCY
PHASE
AMPS
AMPS
GROUND
FAULT TRIP
LEVEL
MILLIAMPS
NOTES
120
50 / 60
1
1 - 50
5000
6
1 or 2 Poles. One pole of a two pole unit must be Neutral
120/240
50 / 60
1
1 - 50
5000
6
2 or 3 Poles. One pole of a three pole unit must be Neutral
Table B: Lists UL Listed and Recognized as an Earth Leakage
Circuit Interruptor - 120 and 120/240V
TABLE B : LISTS UL LISTED AND RECOGNIZED CONFIGURATIONS AS AN EARTH LEAKAGE CIRCUIT INTERRUPTOR - 120 and 120/240V
GROUND
CURRENT SHORT CIRCUIT
VOLTAGE
FAULT TRIP
RATING
CAPACITY
LEVEL
CIRCUIT
MAX.
FREQUENCY PHASE
AMPS
MILLIAMPS
NOTES
AMPS
CONFIGURATION
RATING
SERIES
120
50 / 60
1
1 - 50
5000
30
1 or 2 Poles. One pole of a two pole unit must be Neutral
120/240
50 / 60
1
1 - 50
5000
30
2 or 3 Poles. One pole of a three pole unit must be Neutral
SERIES
120
50 / 60
1
1 - 50
3000
30
1 or 2 Poles. One pole of a two pole unit must be Neutral
IGNITION PROTECTED
120/240
50 / 60
1
1 - 50
5000
30
2 or 3 Poles. One pole of a three pole unit must be Neutral
Table C: Lists UL Listed and Recognized as an Earth Leakage
Circuit Interruptor - 240V
TABLE C : LISTS UL LISTED AND RECOGNIZED CONFIGURATIONS AS AN EARTH LEAKAGE CIRCUIT INTERRUPTOR - 240V
GROUND
CURRENT SHORT CIRCUIT
FAULT TRIP
VOLTAGE
RATING
CAPACITY
LEVEL
CIRCUIT
MAX.
MILLIAMPS
NOTES
FREQUENCY PHASE
AMPS
AMPS
CONFIGURATION
RATING
SERIES
240
50 / 60
1
1 - 30
5000
30
2 or 3 Poles. One pole of a three pole unit must be Neutral. Suffix 11
SERIES IGNITION PROTECTED
240
50 / 60
1
1 - 50
3000
30
2 or 3 Poles. One pole of a three pole unit must be Neutral. Suffix 12
*Manufacturer reserves the right to change product specification without prior notice.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
PC-Series Circuit Breaker - General Specifications | 3
Electrical
Mechanical
Current Ratings
Voltage Rating
Current Trip Level
Current Trip Time
Operating Frequency
Interrupt Capacity
Impedance
1 - 50 Amps maximum
120VAC, 120/240VAC, 240VAC
30mA & 6mA
For 30mA leakage trip:
≤ 22.2mA, shall not trip
30mA, shall trip within .10 seconds
The above complies with UL-1053
& ABYC E11. For 6mA leakage trip: ≤25ms
The above complies with UL-943.
50/60 Hz for 30mA leakage trip
60 Hz for 6mA leakage trip
5,000 Amps
RESISTANCE, IMPEDANCE VALUES
from Line to Load Terminals
(Values Based on Series Trip Circuit Braker)
1000
20.1 - 50.0
100
10
O
H
M
S
1
0.1
10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage.
Trips on short circuit, overload or leakage to ground, even when
actuator is forcibly held in the “On” position
Physical
Number of Poles
(Breakers only) Termination
Mounting
Actuator
1-pole (1 Circuit Breaker + 1
GFCI Sensor Module), 120V
2-pole (2 Circuit Breakers + 1 GFCI Sensor Module), 120/240V or 120V with Neutral Break. 240VAC two pole. 3-pole 120/240V with Neutral Break (Sensor module has 2
pole width) Circuit Breaker Line
Side: #10-32, Threaded stud.
GFCI Sensor Module Load Side: #10-32 threaded stud. Neutral pigtail.
Front Panel, #6-32 and M3 threaded inserts.
Handle, Flat Rocker, Curved Rocker (with or without rocker guard),
Push-to-Reset Rocker
Environmental
Designed and tested in accordance with requirements of
specification MIL-PRF- 55629 and MIL-STD-202G as follows:
0.01
0.001
0.01
Endurance
Trip Free
0.1
1
10
100
AMPERE RATING
Innovative Features
CURRENT
(AMPS)
TOLERANCE
(%)
0.100 - 5.0
± 15%
20.1 - 30.0
± 35%
Indicator
Neutral Protection
Test Button
5.1 - 20.0
± 25%
FIGURE 1
Two integrated LEDs, Red & Green
 Green LED On, Red LED Off
Line Voltage is present, the breaker is closed, and the device is protecting the circuits against over current and leakage current.
 Green LED Off, Red LED On
The device has detected leakage current and has opened the circuit breaker.
 Green LED Flashing, Red LED Off
The circuit breaker has opened due to over current or has been turned off manually
 Green LED Off, Red LED Off
Line Voltage is not present
 Green LED Flashing, Red LED Off, Amber LED ON
Indicates Hot & Neutral are reversed and the circuit breaker
is open
When neutral is grounded on load side of circuit
Located on Ground Fault Module
Shock
Vibration
Moisture Resistance
Operating Temperature
Corrosion
Withstands 100 G, 6ms, sawtooth at rated current per Method 213, Test Condition “I”.
Withstands 0.06” excursion from
10-55 Hz, and 10 G 55-500 Hz, a
rated current per Method 204C, Test
Condition A. Instantaneous & ultrashort curves tested at 90% of rated current.
93% RH at 30°C for 168 Hours.
-35°C to +66°C
UL-943-6.21, 3 weeks
Humidity:
30±2°C, 70±2% relative humidity
Mixed Flowing Gases:
100 ppb H2S, 20 ppb CI2,
200±50 ppb NO2
Agency Certifications
UL Listed
UL Standard 489
Circuit Breakers, Molded Case,
(Guide DIVQ, File E129899)
UL Standard 1077
Supplementary Protectors
UL Standard 943
Class A Ground Fault Circuit Interrupters
UL Standard 1053
Ground Fault Sensing and Relaying Equipment
UL Standard 1500
Ignition Protection
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
4 | PC-Series – Ordering Scheme
PC B
1
Series
2
System
Voltage/Poles
B A
3
Circuit
4
Actuator
24
5
Frequency
& Delay
1 SERIES
PC
620
6
Current Rating
1 B A
7
Terminal
8
Actuator
Color
9
Mounting/
Barriers
A 10
10
Trip Level
11
Agency
Approval
6 CURRENT RATING (AMPERES)
CODE
2 SYSTEM VOLTAGE / POLES
A
120 VAC single phase, one pole
B
120/240 VAC single phase, two pole
C
120/240 VAC single phase with switched neutral, three pole
D
120 VAC single phase with switched neutral, two pole
E
120 VAC single phase with reversed polarity indicator, two pole
F
120/240 VAC single phase with reversed polarity indicator, three pole
G
240 VAC single phase, two pole
3 CIRCUIT
B
Series Trip (Current)
4 ACTUATOR
Handle
A one per pole
B one per multipole unit
Two Color Curved Visi-Rocker
C Indicate ON,
vertical legend
D Indicate ON,
horizontal legend
F Indicate OFF,
vertical legend
G Indicate OFF,
horizontal legend
Single Color Curved Rocker
J Vertical legend
K Horizontal legend
Two Color Curved Visi-Rocker
Push-to-Reset
N Vertical legend
O Horizontal legend
Single Color Curved Rocker
Push-to-Reset
R Vertical legend
U Horizontal legend
Two Color Flat Visi-Rocker
1 Indicate OFF,
vertical legend
2 Indicate OFF,
horizontal legend
Single Color Flat Rocker
3 Vertical legend
4 Horizontal legend
Two Color Flat Visi-Rocker
Push-to-Reset
5 Indicate OFF,
vertical legend
6 Indicate OFF,
horizontal legend
Single Color Flat Rocker
Push-to-Reset
7 Vertical legend
8 Horizontal legend
5 FREQUENCY & DELAY
20
50/60Hz Instantaneous
21
50/60Hz Ultra Short
22
50/60Hz Short
24
50/60Hz Medium
26
50/60Hz Long
Notes:
1 This device meets the requirements of ABCY E11.
2 6mA per UL943, available with agency approval code 10.
3 30mA per UL1053, available with agency approval codes 11 & 12.
4 AIC Rating at 120 VAC 3kA, at 120/240 VAC 5kA
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
AMPERES
0.100
0.150
0.200
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
285
290
295
410
512
415
517
420
522
425
527
430
435
440
445
0.850
0.900
0.950
1.000
1.250
1.500
1.750
2.000
2.250
2.500
2.750
3.000
3.500
4.000
4.500
450
455
460
465
470
475
480
485
490
495
610
710
611
711
612
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
10.500
11.000
11.500
12.000
712
613
614
615
616
617
618
620
622
624
625
630
635
640
650
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
50.000
7 TERMINAL
1
Stud, 10-32 threaded
8 ACTUATOR COLOR & LEGEND
HandleRocker Actuator Color
Actuator Color I-O ON-OFF Dual
Single
Visi-Rocker
White
A B 1Black
White
Black
C D 2White
N/A
Red
F G 3White
Red
Green
H J 4White Green
Blue
K L 5White
Blue
Yellow
M N 6Black Yellow
Gray
P Q 7Black
Gray
Orange
R S 8Black Orange
9 MOUNTING/BARRIERS
MOUNTING STYLE
BARRIERS
Threaded Insert, 2 per pole
A 6-32 X 0.195 inches
yes
B ISO M3 x 5mm
yes
Rockerguard Bezel
Threaded Insert, 2 per pole
C 6-32 X 0.195 inches yes
D ISO M3 x 5mm
yes
Standard Bezel with Recessed Off-Side Flat Rocker
Threaded Insert, 2 per pole
E 6-32 X 0.195 inches yes
F ISO M3 x 5mm yes
Push-to-Reset Bezel
Threaded Insert, 2 per pole
G 6-32 X 0.195 inches yes
H ISO M3 x 5mm yes
10 LEAKAGE CURRENT TRIP LEVEL - MAX. TRIP CURRENT
A 5 MA (CLASS A GFCI)2
E 30 MA (ELCI)1,3
11 AGENCY APPROVAL
AA W/O Approvals
UL 9432
10
UL 10531,3
11
UL 1053 & UL 15001,3,4
12
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
PC-Series – Wiring Diagrams | 5
INDICATE OFF / SINGLE COLOR
ROCKER ACTUATOR
HANDLE / INDICATE ON
ROCKER ACTUATOR
TERMINAL
LOCATIONS
PCE
120 VAC VER
W/ REVERSE P
INDICATO
PCA
120 VAC
VERSION
PCF
120/240 VAC VER
W/ REVERSE POL
INDICATOR
PCB
120/240 VAC
VERSION
3.015
[76.58]
MAX.
PCC
120/240 VAC
VERSION
W/ NEUTRAL BREAK
3.775
[95.88]
MAX.
PCD
120 VAC
VERSION
W/NEUTRAL BREAK
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
URCE
TRAL
6 | PC-Series – Wiring Diagrams & Panel Cut Out
TERMINAL
LOCATIONS
HANDLE / INDICATE ON
ROCKER ACTUATOR
INDICATE OFF / SINGLE COLOR
ROCKER ACTUATOR
PCE
120 VAC VERSION
W/ REVERSE POLARITY
INDICATOR
PCF
120/240 VAC VERSION
W/ REVERSE POLARITY
INDICATOR
NOTE: NEUTRAL & GROUND PIGTAIL WIRES - SUPPLIED 12" LONG MIN. (CIRCUIT CODES A,B,E & F)
3.790 [96.27]
3.040 [77.22]
2.280 [57.91]
1.453 [36.91]
LINE 1
LINE 2
2.062 [52.37]
3.790 [96.27]
3.040 [77.22]
3.040 [77.22]
3.040 [77.22]
2.280 [57.91]
2.280
[57.91]
2.280
[57.91]
.156 DIA..156
[Ø3.96]
DIA. [Ø3.96]
2 PLC'S.2TYP.
PLC'S. TYP.
PER POLE
PER POLE
1.660 [42.16]
1.660 [42.16]
1.453 [36.91]
1.260 [32.00]
1.260 [32.00]
2.062 [52.37]
.200 [5.08]
.432 [10.97]
.432 [10.97]
PCA
LOAD HOT 2
OR 230V NEUTRAL
LOAD HOT 1
LINE 2
OR 230V NEUTRAL
LINE 1
.750 [19.05]
TYP.
.750 [19.05]
TYP.
PCA, PCB
PCD & PCE
.200 [5.08]
PCA, PCB
& PCF
PCD &PCC
PCE
PCA
PCC & PCF
PCB, PCD & PCE
PCC & PCF
PCB, PCD & PCE
HANDLE ACTUATOR
ROCKER ACTUATOR
PCC & PCF
HANDLE ACTUATOR
PANEL CUTOUT DETAIL
ROCKER ACTUATOR
TOLERANCES ±.005 [.12]
1-Phase 240VAC
PANEL CUTOUT DETAIL
TOLERANCES ±.005 [.12]
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
PC-Series – Dimensions | 7
2.265
[57.53]
MAX.
1.510
[38.35]
2.975
[75.57]
0.430
[10.92]
0.275
[6.99]
0.750
TYP.
[19.05]
2.518
[63.96]
3.800
[96.52]
2.062
[52.37]
1.453
[36.91]
0.429
[10.91]
0.350
[8.89]
NEUTRAL PIGTAIL (CIRCUIT
CODE A+B ONLY)
#6/32 / M3 MOUNTING INSERTS
0.125
[3.18]
1.245
1.660 [31.62]
[42.16]
0.208
[5.28]
0.100
[2.54]
Notes:
For additional circuit breaker dimensions, reference the C-Series Breakers in the
Carling Circuit Protection catalog
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
8 | PC-Series – Panel Seal Ordering Scheme
8 PC
1
Type
Number
2
Series
1 4 1
3
Actuator
4
Poles
5
Mounting
5 MOUNTING SCREWS / PLATE MATERIAL1
1 6-32 Thread Phillips Head
2 M-3 Thread Phillips Head
3 6-32 Thread Slotted Head
4 M-3 Thread Slotted Head
5 6-32 Thread Phillips Head w/ Stainless Steel Plate
6 M-3 Thread Phillips Head w/ Stainless Steel Plate
7 6-32 Thread Slotted Head w/ Stainless Steel Plate
8
M-3 Thread Slotted Head w/ Stainless Steel Plate
1 TYPE NUMBER
8
Circuit Breaker Assembly
2 SERIES
PC
3 ACTUATOR TYPE
1
Handle, one per pole
2
Handle, one per multipole unit
ARocker2
4 POLES PER UNIT - INCLUDING ELECTRONIC MODULE
3Three
4Four
5Five
Notes:
1 Screws supplied to accommodate mounting panel thickness of 1/8” ± 1/32”.
Consult Factory for additional options
2 Available for Flat and Curved Rocker options - No Rockerguard Bracket
Handle Style Panel Seal
Rocker Style Panel Seal
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
PC-Series – Panel Seal Configuration - Drawings | 9
Handle Actuator
Rocker Actuator
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
10 | PC-Series –Time Delay Curves
Time Delay Curves
Instantaneous
Medium
Ultra Short
Long
Short
Notes:
Other time delay values available, consult factory.
Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125% of rated
current and greater within the time limit shown in this curve.
Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated current
and greater within the time limit shown in this curve.
All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard
wall-mount position.
The minimum inrush pulse tolerance handling capability is 12 times the rated current. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse.
REV_GFCI_PC_10_2013