10 W AC-DC Power-Supply PAC10D ● ● ● ● ● ● ● Enclosed plastic case 85 … 264VAC universal input range Continuously short circuit protected Over voltage protected Isolation class II 3 years product warranty PCB-, Chassis- and DIN Rail mountable version Model selection guide Type Output voltage PAC10D3R3S PAC10D05S PAC10D09S PAC10D12S PAC10D15S PAC10D24S [VDC] 3.3 5.0 9.0 12 15 24 Output voltage tolerance [%] typ. ±3 ±2 ±2 ±2 ±2 ±2 Output current max. [mA] 2000 2000 1100 900 700 450 Ripple & noise up to 20 MHz max. [mVp-p] 100 100 100 100 100 100 Efficiency typ. @ full load [%] 71 76 80 81 82 83 Stand by consumption [W] 0.4 0.4 0.45 0.4 0.5 0.6 Capacitive load max. [µF] 15000 12000 6000 2000 1500 500 Specifications Input Voltage range Line frequency range Full load input current Inrush current Recommended fuse Isolation Isolation voltage (input to output) Leakage current Output Line regulation Load regulation @ 10...100 % load change Temperature coefficient Ripple & noise up to 20 MHz Output over voltage protection P10D03S, P10D05S P10D09S P10D12S, P10D15S P10D24S Protection Short circuit Over current Over temperature General Switching frequency Hold up time @ full load Reliability MTBF @ 25°C 85..264 VAC or 100..370 VDC 47…63 Hz 230 mA @ 115 VAC, typ. 150 mA @ 230 VAC, typ. 10 A typ. @ 115 VAC 20 A typ. @ 230 VAC 2 A / 250 V, time delay fuse 4000 VAC for 1 min. 0.1 mA typ. @ Vin 230 VAC ±0.5 %, typ. ±1 %, typ. ± 0.02 % / °C 100 mVp-p, max. 7.5 VDC, max. 15 VDC, max. 20 VDC, max. 30 VDC, max. Continuous, auto recovery 200 %, max. of rated current 150 °C, max. EMC EMI: with circuit figure 2 Conducted Radiation emission ESD: Electrostatic discharge RS: field susceptibility EFT: Fast transients on mainsline Surge: External circuit is required to converter at inrush and fast transient test, refer to typical application! Safety approvals Safety Environmental Operating temperature (ambient) Storage temperature Power derating above 55°C and below 0°C Sorage humidity Cooling Physical Dimensions, PCB version Weight Case material Soldering temperature EN55011 (CISPR11), class B EN55011 (CISPR11), class B IEC-, EN61000-4-2, air ±15kV, contact ± 8kV, pref. Crit. B IEC-, EN61000-4-3, 10V/m pref. Crit. A IEC-, EN61000-4-4, ± 4kV, pref. Crit. B IEC, EN61000-4-5, ±2kV/± 4kV, pref. Crit. B EN60950, UL60950 Class II -25 … 70 °C (with derating) -25 °C to +105 °C 2% per °C, See diagram 95 %, non condensing Free air convection 53.5 x 28.5 x 19 mm PCB version 50g UL94V-0 rated 260°C, 10s, 1.5mm from case 65 kHz typ. 80 ms @ 230 VAC. typ. >300000 h Page 1 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected] 10 W AC-DC Power-Supply PAC10D Typical application circuit for EN55011 Class A compliance Figure 1 L PAC10DxxS F1 C1 ~ U N C2 R1 D1 +Vout -Vout = Model PAC10D3R3S PAC10D05S PAC10D09S PAC10D12S PAC10D15S PAC10D24S F1 Time delay Fuse 2A / 250V~ 2A / 250V~ 2A / 250V~ 2A / 250V~ 2A / 250V~ 2A / 250V~ R1 MOV S14K300 S14K300 S14K300 S14K300 S14K300 S14K300 C1 [µF] 0.1 0.1 0.1 0.1 0.1 0.1 C2 [µF] 220 220 120 120 120 68 D1 TVS P6KE6.8A P6KE6.8A P6KE12A P6KE20A P6KE20A P6KE30A Page 2 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected] 10 W AC-DC Power-Supply PAC10D Application circuit for ripple and noise reduction for EN55011 Class B compliance Figure 2 F1 L1 CML Rs PAC10DxxS N CY ~ +Vout CX R1 U C2 C1 D1 -Vout CY = Rs N PE Model C1 C2 PAC10D3R3S PAC10D05S PAC10D09S PAC10D12S PAC10D15S PAC10D24S [µF] 0.1 0.1 0.1 0.1 0.1 0.1 [µF] 220 220 120 120 120 68 Note: 1. 2. 3. 4. F1 Time delay Fuse 2A / 250V~ 2A / 250V~ 2A / 250V~ 2A / 250V~ 2A / 250V~ 2A / 250V~ R1 MOV S14K300 S14K300 S14K300 S14K300 S14K300 S14K300 Rs Wire Resistor 12 Ω, 3 W 12 Ω, 3 W 12 Ω, 3 W 12 Ω, 3 W 12 Ω, 3 W 12 Ω, 3 W D1 TVS P6KE6.8A P6KE6.8A P6KE12A P6KE20A P6KE20A P6KE30A CY Y type [nF] 2.2 2.2 2.2 2.2 2.2 2.2 CX X type [µF] 0.1 0.1 0.1 0.1 0.1 0.1 L1 CML 4.7 µH, 2 A 4.7 µH, 2 A 4.7 µH, 2 A 4.7 µH, 2 A 4.7 µH, 2 A 4.7 µH, 2 A [mH] 10..30 10..30 10..30 10..30 10..30 10..30 Output filtering capacitor C1 is a ceramic type, it is used to suppress high frequency noise. C2 is an electrolytic capacitor. It is recommended to use high frequency and low impedance electrolytic capacitors. For capacitance and current of capacitor please refer to datasheet. Voltage derating of capacitor should be 80 % or above. TVS D1 is a recommended component to protect post circuits (if converter fails). The Varistor R2 protect the device under surge. Recommended fuse parameter for F1 is a 2 A / 250 V “time delay” type. External input resistors Rs limited the inrush current. (see figure 1 and table) If common requirement to EMC performance (EN55011 Class A), refer to figure 1. If higher requirement to EMC performance (EN55011 Class B), refer to figure 2. Page 3 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected] 10 W AC-DC Power-Supply PAC10D Dimensions Pin assignment Pin 1 2 3 4 Note Unit: mm Pin diameter: 1 ± 0.1 mm General tolerances: ± 0.5 mm AC In (N) AC In (L) + DC Out - DC Out PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for use carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 02.16 f Page 4 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected]