Download

1W AC-DC Power-Supply PAC1BxxSB
●
●
●
●
●
85 … 264 VAC universal input range
Continuously short circuit and over current protected
Isolation class II
MTBF > 300000 h
Very small outlines
Model guide
Type
PAC1B05SB
PAC1B09SB
PAC1B12SB
PAC1B15SB
PAC1B24SB
Output voltage
Accuracy
[VDC]
[%] max.
5.0
±8
9.0
±5
12
±5
15
±5
24
±5
Output current
[mA] max.
200
111
83
67
42
Ripple & noise up
to 20 MHz
[mVp-p] max.
120
120
120
120
120
Efficiency typ.@ full
load, Vin 230 VAC
[%]
66
67
70
69
68
Capacitive load
[µF]
220
100
100
100
100
Specifications
Input
Voltage range
Frequency
Full load input current
Inrush current
Standby power
Recommended fuse
Hold up time
Isolation
Isolation voltage (input to output)
Isolation resistance
Output
Ripple & noise BW 20 MHz
Minimum load
Line regulation
Load regulation @ 5 to
100% load change
Temperature coefficient
85..264 VAC or
70..400 VDC
Power derating see diagram
47…440 Hz
120 mA max @ 115 VAC
40 mA max @ 230 VAC
9 A @ 115 VAC
15 A @ 230 VAC
0.5 W, max.
1 A, 250 VAC, time delay
40 ms @ 115 VAC
180 ms @ 230 VAC
3000 VAC for 1 minute
100 MΩ
120 mV
5%
±1.5 %, typ.
±2.5 %, typ.
0.15 % / °C
Conducted emission
EMI
Radiation emission
ESD Electrostatic discharge
RS field susceptibility
EMC
EFT Fast transients on mains line
EMS
Surge
CS
PFM
Voltage dips,
short and interruptions immunity
Protection
Short circuit
Over current protection
Over temperature
General
Reliability MTBF@25°C
Switching frequency
Environmental
Operating temperature
(ambient)
Power derating
Storage temperature
Case temperature
Humidity
Cooling
Safety standard
Physical
Dimensions
Weight
Case material
Mounting
Soldering temperature, Time
Continuous, auto recovery
>110 % of full load
No
>200000 h (MIL-HDBK-217)
~ 60 kHz
-40 °C to +85 °C
(with derating, see diagram)
see diagram
-40 °C to +105 °C
90 °C, max.
85 %, max.
Free air convection
IEC60950, EN60950, UL60950
35 x 18 x 11 mm
7g
UL94V-0
On PCB
Wave 265 °C max., 10 s max.
Manual 370 °C max., 5 s max.
EN55022 (CISPR22), class A (External circuit refer to fig. 2)
EN55022 (CISPR22), class B (External circuit refer to fig. 3)
EN55022 (CISPR22), class A (External circuit refer to fig. 2)
EN55022 (CISPR22), class B (External circuit refer to fig. 3)
IEC, EN61000-4-2 contact ± 4 kV perf. criteria B
IEC, EN61000-4-3, 10 V/m perf. criteria A (External circuit refer to fig. 3)
IEC, EN61000-4-4, ± 2 kV, perf. criteria B (External circuit refer to fig. 2)
IEC, EN61000-4-4, ± 4 kV, perf. criteria B (External circuit refer to fig. 3)
IEC, EN61000-4-5, ± 1 kV perf. criteria B (External circuit refer to fig. 3)
IEC, EN61000-4-5, ± 2 kV perf. criteria B (External circuit refer to fig. 3)
IEC, EN61000-4-6, 10 V rms perf. criteria A (External circuit refer to fig. 3)
IEC, EN61000-4-8, 10 A/m perf. criteria A
IEC, EN61000-4-11, 0…70 % perf. criteria B
1. External electrolytic capacitor are required to models. More details refer to typical applications.
2. Ripple and noise were measured refer to “ripple and noise measure figure”.
3. All specifications were measured at Ta 25 °C, humidity <75 %, nominal input voltage (115 VAC or 230 VAC) and rated output load
unless otherwise specified.
4. Module required dispensing fixed after assembled.
Page 1 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
1W AC-DC Power-Supply PAC1BxxSB
Functional diagram
1
Vin (N)
Input
rectifier
3
Vin (L)
12
+ Vout
Output
rectifier &
filter
DC/DCConverter
10
- Vout
5
C1
External
capacitor
7
Application note inadmissible connection
PAC1BxxSB
L
+Vout
-Vout
N
PE
This connection is not recommented becouse of EMI problems!
Ripple and noise measure configuration
PAC1BxxSB
F1
L
C2
L1
C3
C4
Load
12
+Vo
3
Measure points for
oscilloscope probe
-Vo
10
N
1
7 C1
5
CY
Figure 2 EMC application circuit for standard requirement
L
N
F1
NTC
L2
PAC1BxxSB
C2
L1
C3
D1
C4 +Vout
-Vout
U
MOV1
C1
CY
For standard EMC requirement, please refer to figure 2, recommended parameters are shown in this table.
Type
F1
MOV1
NTC
L1
L2
CY
C1
C2
PAC1B05SB
150 µF
PAC1B09SB
1 A,
4.7 µF
Type
Type
1 nF
PAC1B12SB
250 VAC,
2.2 µH 1 mH
S14K350 5D-9
400 VAC 400 V
100 µF
PAC1B15SB time delay
PAC1B24SB
C3
C4
68 µF
35 V
0.1 µF
50 V
ceramic
D1
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ30A
Page 2 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
1W AC-DC Power-Supply PAC1BxxSB
Recommend PCB layout
Linewidth ≥3 mm, line to line distance ≥6 mm, line- ground distance ≥6mm, undefined unit: mm
Figure 3, EMC application circuit for applications with higher EMC requirement
Complete input filter module PIF003A
PAC1BxxSB
L F1
L
LDM
C2
CY
MOV2
U
CX
L1
C3 D1 C4 +Vout
+
Rd
-Vout
CY
N
N
LCM
PE
C1
CY
For higher EMC requirement, please refer to figure 3, recommended parameters are shown in this table.
Type
F1
Filter module
CY
C1
C2
C3
C4
PAC1B05SB
150 µF
PAC1B09SB
1 A,
0.1 µF
10 µF,
1 nF,
PAC1B12SB
PIF003A
250 VAC,
68 µF, 35 V
50 V
400 V
400 VAC
ceramic
100 µF
PAC1B15SB time delay
PAC1B24SB
D1
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ30A
Note:
C1 and C3 are electrolytic capacitors and they are required. C2, C3 and L1 form a pi-type filter circuit for AC- and DC- input
voltage. C2 and C3 are output filter capacitors, they are recommended to be high frequency and low impedance electrolytic
capacitors. Capacitance and rated ripple current of capacitors refer to the data sheets provided by the manufactures. Voltage
derating of capacitors should be 80 % or above.
At AC input voltage use C1 as filter capacitor. The recommended value of C1 should be 4.7 μF / 400 V.
At DC input voltage use C1 as EMC filter capacitor. The recommended value of C1 should be 4.7 μF / 400 V.
When the input voltage is above 370 VDC is the recommended value of C1 4.7 μF / 450 V.
C4 is a ceramic capacitor, which is used to filter high frequency noise. Current of L1 and L2 refer to the datas heets provided
by the manufactures, current derating should be 80% or above.
TVS is a recommended component to protect following circuits, if the converter fails.
External input NTC is recommended to use 5D-9.
External input MOV1 is recommended to use S14K350.
Page 3 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
1W AC-DC Power-Supply PAC1BxxSB
Page 4 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
1W AC-DC Power-Supply PAC1BxxSB
Dimensions
1
3
5
7
10
12
Pin connections
AC In (N) or -Vin
AC In (L) or +Vin
+ Capacitor (C1)
- Capacitor (C1)
- DC Out
+ DC Out
PHI-CON is a trademark of HY-LINE Holding GmbH.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for
use carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected
to result in significant injury to the user. Rev: 03.16 f
Page 5 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]