1W AC-DC Power-Supply PAC1BxxSB ● ● ● ● ● 85 … 264 VAC universal input range Continuously short circuit and over current protected Isolation class II MTBF > 300000 h Very small outlines Model guide Type PAC1B05SB PAC1B09SB PAC1B12SB PAC1B15SB PAC1B24SB Output voltage Accuracy [VDC] [%] max. 5.0 ±8 9.0 ±5 12 ±5 15 ±5 24 ±5 Output current [mA] max. 200 111 83 67 42 Ripple & noise up to 20 MHz [mVp-p] max. 120 120 120 120 120 Efficiency typ.@ full load, Vin 230 VAC [%] 66 67 70 69 68 Capacitive load [µF] 220 100 100 100 100 Specifications Input Voltage range Frequency Full load input current Inrush current Standby power Recommended fuse Hold up time Isolation Isolation voltage (input to output) Isolation resistance Output Ripple & noise BW 20 MHz Minimum load Line regulation Load regulation @ 5 to 100% load change Temperature coefficient 85..264 VAC or 70..400 VDC Power derating see diagram 47…440 Hz 120 mA max @ 115 VAC 40 mA max @ 230 VAC 9 A @ 115 VAC 15 A @ 230 VAC 0.5 W, max. 1 A, 250 VAC, time delay 40 ms @ 115 VAC 180 ms @ 230 VAC 3000 VAC for 1 minute 100 MΩ 120 mV 5% ±1.5 %, typ. ±2.5 %, typ. 0.15 % / °C Conducted emission EMI Radiation emission ESD Electrostatic discharge RS field susceptibility EMC EFT Fast transients on mains line EMS Surge CS PFM Voltage dips, short and interruptions immunity Protection Short circuit Over current protection Over temperature General Reliability MTBF@25°C Switching frequency Environmental Operating temperature (ambient) Power derating Storage temperature Case temperature Humidity Cooling Safety standard Physical Dimensions Weight Case material Mounting Soldering temperature, Time Continuous, auto recovery >110 % of full load No >200000 h (MIL-HDBK-217) ~ 60 kHz -40 °C to +85 °C (with derating, see diagram) see diagram -40 °C to +105 °C 90 °C, max. 85 %, max. Free air convection IEC60950, EN60950, UL60950 35 x 18 x 11 mm 7g UL94V-0 On PCB Wave 265 °C max., 10 s max. Manual 370 °C max., 5 s max. EN55022 (CISPR22), class A (External circuit refer to fig. 2) EN55022 (CISPR22), class B (External circuit refer to fig. 3) EN55022 (CISPR22), class A (External circuit refer to fig. 2) EN55022 (CISPR22), class B (External circuit refer to fig. 3) IEC, EN61000-4-2 contact ± 4 kV perf. criteria B IEC, EN61000-4-3, 10 V/m perf. criteria A (External circuit refer to fig. 3) IEC, EN61000-4-4, ± 2 kV, perf. criteria B (External circuit refer to fig. 2) IEC, EN61000-4-4, ± 4 kV, perf. criteria B (External circuit refer to fig. 3) IEC, EN61000-4-5, ± 1 kV perf. criteria B (External circuit refer to fig. 3) IEC, EN61000-4-5, ± 2 kV perf. criteria B (External circuit refer to fig. 3) IEC, EN61000-4-6, 10 V rms perf. criteria A (External circuit refer to fig. 3) IEC, EN61000-4-8, 10 A/m perf. criteria A IEC, EN61000-4-11, 0…70 % perf. criteria B 1. External electrolytic capacitor are required to models. More details refer to typical applications. 2. Ripple and noise were measured refer to “ripple and noise measure figure”. 3. All specifications were measured at Ta 25 °C, humidity <75 %, nominal input voltage (115 VAC or 230 VAC) and rated output load unless otherwise specified. 4. Module required dispensing fixed after assembled. Page 1 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected] 1W AC-DC Power-Supply PAC1BxxSB Functional diagram 1 Vin (N) Input rectifier 3 Vin (L) 12 + Vout Output rectifier & filter DC/DCConverter 10 - Vout 5 C1 External capacitor 7 Application note inadmissible connection PAC1BxxSB L +Vout -Vout N PE This connection is not recommented becouse of EMI problems! Ripple and noise measure configuration PAC1BxxSB F1 L C2 L1 C3 C4 Load 12 +Vo 3 Measure points for oscilloscope probe -Vo 10 N 1 7 C1 5 CY Figure 2 EMC application circuit for standard requirement L N F1 NTC L2 PAC1BxxSB C2 L1 C3 D1 C4 +Vout -Vout U MOV1 C1 CY For standard EMC requirement, please refer to figure 2, recommended parameters are shown in this table. Type F1 MOV1 NTC L1 L2 CY C1 C2 PAC1B05SB 150 µF PAC1B09SB 1 A, 4.7 µF Type Type 1 nF PAC1B12SB 250 VAC, 2.2 µH 1 mH S14K350 5D-9 400 VAC 400 V 100 µF PAC1B15SB time delay PAC1B24SB C3 C4 68 µF 35 V 0.1 µF 50 V ceramic D1 SMBJ7.0A SMBJ12A SMBJ20A SMBJ30A Page 2 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected] 1W AC-DC Power-Supply PAC1BxxSB Recommend PCB layout Linewidth ≥3 mm, line to line distance ≥6 mm, line- ground distance ≥6mm, undefined unit: mm Figure 3, EMC application circuit for applications with higher EMC requirement Complete input filter module PIF003A PAC1BxxSB L F1 L LDM C2 CY MOV2 U CX L1 C3 D1 C4 +Vout + Rd -Vout CY N N LCM PE C1 CY For higher EMC requirement, please refer to figure 3, recommended parameters are shown in this table. Type F1 Filter module CY C1 C2 C3 C4 PAC1B05SB 150 µF PAC1B09SB 1 A, 0.1 µF 10 µF, 1 nF, PAC1B12SB PIF003A 250 VAC, 68 µF, 35 V 50 V 400 V 400 VAC ceramic 100 µF PAC1B15SB time delay PAC1B24SB D1 SMBJ7.0A SMBJ12A SMBJ20A SMBJ30A Note: C1 and C3 are electrolytic capacitors and they are required. C2, C3 and L1 form a pi-type filter circuit for AC- and DC- input voltage. C2 and C3 are output filter capacitors, they are recommended to be high frequency and low impedance electrolytic capacitors. Capacitance and rated ripple current of capacitors refer to the data sheets provided by the manufactures. Voltage derating of capacitors should be 80 % or above. At AC input voltage use C1 as filter capacitor. The recommended value of C1 should be 4.7 μF / 400 V. At DC input voltage use C1 as EMC filter capacitor. The recommended value of C1 should be 4.7 μF / 400 V. When the input voltage is above 370 VDC is the recommended value of C1 4.7 μF / 450 V. C4 is a ceramic capacitor, which is used to filter high frequency noise. Current of L1 and L2 refer to the datas heets provided by the manufactures, current derating should be 80% or above. TVS is a recommended component to protect following circuits, if the converter fails. External input NTC is recommended to use 5D-9. External input MOV1 is recommended to use S14K350. Page 3 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected] 1W AC-DC Power-Supply PAC1BxxSB Page 4 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected] 1W AC-DC Power-Supply PAC1BxxSB Dimensions 1 3 5 7 10 12 Pin connections AC In (N) or -Vin AC In (L) or +Vin + Capacitor (C1) - Capacitor (C1) - DC Out + DC Out PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for use carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 03.16 f Page 5 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected]