Download

3 W AC-DC Power-Supply PAC3BxxSB(B)
●
●
●
●
●
85 … 264 VAC universal input range
Continuously short circuit and over current protected
Isolation class II
MTBF > 300000 h
Very small outlines
Model guide
Type
PAC3B03SB
PAC3B05SB
PAC3B09SB
PAC3B12SB
PAC3B15SB
PAC3B24SB
Output voltage
Accuracy
[VDC]
[%] max.
3.3
±8
5.0
±5
9.0
±5
12
±5
15
±5
24
±5
Output current
[mA] max.
500
500
333
250
200
125
Ripple & noise up
to 20 MHz
[mVp-p] max.
150
150
150
150
150
150
Efficiency typ.@ full
load, Vin 230 VAC
[%]
63
68
75
77
78
80
Capacitive load
[µF]
470
470
150
100
100
100
Specifications
Input
Voltage range
Frequency
Full load input current
Inrush current
No load power consumption
Recommended fuse
Hold up time
Isolation
Isolation voltage (input to output)
Isolation resistance
Output
Ripple & noise BW 20 MHz
Minimum load
Line regulation
Load regulation @ 5 to
100% load change
Temperature coefficient
85..264 VAC or
70..400 VDC
Power derating see diagram
47…440 Hz
120 mA max @ 115 VAC
60 mA max @ 230 VAC
13 A @ 115 VAC
23 A @ 230 VAC
0.5 W, max.
1 A, 250 VAC, time delay type
20 ms @ 115 VAC
80 ms @ 230 VAC
3000 VAC for 1 minute
100 MΩ
50…70 mV, typ.
5%
±1.5 %, typ.
±2.5 %, typ.
0.15 % / °C
Conducted emission
EMI
Radiation emission
ESD Electrostatic discharge
RS field susceptibility
EMC
EFT Fast transients on mains line
EMS
Surge
CS
PFM
Voltage dips,
short and interruptions immunity
Protection
Short circuit
Over current protection
Over temperature
General
Reliability MTBF@25°C
Switching frequency
Environmental
Operating temperature
(ambient)
Power derating
Storage temperature
Case temperature
Humidity
Cooling
Safety standard
Physical
Dimensions
Weight
Case material
Mounting
Soldering temperature, Time
Continuous, auto recovery
> 110 % of full load
No
> 300000 h (MIL-HDBK-217)
~ 60 kHz
-40 °C to +85 °C
(with derating, see diagram)
see diagram
-40 °C to +105 °C
90 °C, max.
85 %, max.
Free air convection
IEC60950, EN60950, UL60950
35 x 18 x 11 mm
7g
UL94V-0
On PCB
Wave 265 °C max., 10 s max.
Manual 370 °C max., 5 s max.
EN55022 (CISPR22), class A (External circuit refer to fig. 2)
EN55022 (CISPR22), class B (External circuit refer to fig. 3)
EN55022 (CISPR22), class A (External circuit refer to fig. 2)
EN55022 (CISPR22), class B (External circuit refer to fig. 3)
IEC, EN61000-4-2 contact ± 4 kV perf. criteria B
IEC, EN61000-4-3, 10 V/m perf. criteria A (External circuit refer to fig. 3)
IEC, EN61000-4-4, ± 2 kV, perf. criteria B (External circuit refer to fig. 2)
IEC, EN61000-4-4, ± 4 kV, perf. criteria B (External circuit refer to fig. 3)
IEC, EN61000-4-5, ± 1 kV perf. criteria B (External circuit refer to fig. 3)
IEC, EN61000-4-5, ± 2 kV perf. criteria B (External circuit refer to fig. 3)
IEC, EN61000-4-6, 10 V rms perf. criteria A (External circuit refer to fig. 3)
IEC, EN61000-4-8, 10 A/m perf. criteria A
IEC, EN61000-4-11, 0…70 % perf. criteria B
1. External electrolytic capacitor are required to models. More details refer to typical applications.
2. Ripple and noise were measured refer to “ripple and noise measure figure”.
3. All specifications were measured at Ta 25 °C, humidity <75 %, nominal input voltage (115 VAC or 230 VAC) and rated output load
unless otherwise specified.
4. Module required dispensing fixed after assembled.
Page 1 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
3 W AC-DC Power-Supply PAC3BxxSB(B)
Functional diagram
1
Vin (N)
Input
rectifier
3
Vin (L)
12
+ Vout
Output
rectifier &
filter
DC/DCConverter
10
- Vout
5
C1
External
capacitor
7
Application note inadmissible connection
PAC3BxxSB
L
+Vout
-Vout
N
PE
This connection is not recommented becouse of EMI problems!
Ripple and noise measure configuration
PAC3BxxSB
F1
L
C2
L1
C3
C4
Load
12
+Vo
3
Measure points for
oscilloscope probe
-Vo
10
N
1
7 C1
5
CY
Figure 2 EMC application circuit for standard requirement
L
N
F1
NTC
L2
PAC3BxxSB
C2
L1
C3
D1
C4 +Vout
-Vout
U
MOV1
C1
CY
For standard EMC requirement, please refer to figure 2, recommended parameters are shown in this table.
Type
F1
MOV1
NTC
L1
L2
CY
C1
C2
PAC3B03SB
PAC3B05SB
330 µF
1 A,
PAC3B09SB
10 µF
Type
Type
1 nF
250 VAC,
2.2 µH 5 mH
S14K320 13D-5
400 VAC 400 V
PAC3B12SB
time delay
150 µF
PAC3B15SB
PAC3B24SB
100 µF
C3
120 µF
68 µF
35 V
C4
D1
SMBJ7.0A
0.1 µF
50 V
ceramic
SMBJ12A
SMBJ20A
SMBJ30A
Page 2 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
3 W AC-DC Power-Supply PAC3BxxSB(B)
Recommend PCB layout
Linewidth ≥3 mm, line to line distance ≥6 mm, line- ground distance ≥6mm, undefined unit: mm
Figure 3, EMC application circuit for applications with higher EMC requirement
Complete input filter module PIF003A
PAC3BxxSB
L F1
L
LDM
C2
CY
MOV2
U
CX
L1
C3 D1 C4 +Vout
+
Rd
-Vout
CY
N
N
LCM
PE
C1
CY
For higher EMC requirement, please refer to figure 3, recommended parameters are shown in this table.
Type
F1
Filter module
CY
C1
C2
C3
C4
PAC3B03SB
120 µF, 25 V
330 µF
PAC3B05SB
1 A,
0.1 µF
PAC3B09SB
10 µF,
1 nF,
250 VAC,
PIF003A
50 V
400
V
400
V
PAC3B12SB
68 µF, 35 V
AC
time delay
ceramic
150 µF
PAC3B15SB
PAC3B24SB
100 µF
D1
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ30A
Note:
C1 and C3 are electrolytic capacitors and they are required. C2, C3 and L1 form a pi-type filter circuit for AC- and DC- input
voltage. C2 and C3 are output filter capacitors, they are recommended to be high frequency and low impedance electrolytic
capacitors. Capacitance and rated ripple current of capacitors refer to the data sheets provided by the manufactures. Voltage
derating of capacitors should be 80 % or above.
At AC input voltage use C1 as filter capacitor. The recommended value of C1 should be 10 μF / 400 V.
At DC input voltage use C1 as EMC filter capacitor. The recommended value of C1 should be 10 μF / 400 V.
When the input voltage is above 370 VDC is the recommended value of C1 10 μF / 450 V.
C4 is a ceramic capacitor, which is used to filter high frequency noise. Current of L1 and L2 refer to the datas heets provided
by the manufactures, current derating should be 80% or above.
TVS is a recommended component to protect following circuits, if the converter fails.
External input NTC is recommended to use 13D-5.
External input MOV1 is recommended to use S14K320.
Page 3 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
3 W AC-DC Power-Supply PAC3BxxSB(B)
Page 4 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
3 W AC-DC Power-Supply PAC3BxxSB(B)
Dimensions PAC3BxxSB
1
3
5
7
10
12
Pin connections
AC In (N) or -Vin
AC In (L) or +Vin
+ Capacitor (C1)
- Capacitor (C1)
- DC Out
+ DC Out
Dimensions PAC3BxxSBB
PHI-CON is a trademark of HY-LINE Holding GmbH.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for
use carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected
to result in significant injury to the user. Rev: 03.16 f
Page 5 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]