60W AC-DC Power-Supply PAC60C ● ● ● ● ● ● ● PCB-mountable plastic case AC and DC universal input Continuously short circuit protected Over current protected Input under voltage protected Safe isolation 4 kVAC 3 years product warranty Model guide Type Output voltage Output voltage tolerance PAC60C05S PAC60C09S PAC60C12S PAC60C15S PAC60C24S PAC60C48S [VDC] 5 9 12 15 24 48 typ. [%] ±2 ±2 ±2 ±2 ±2 ±2 Output current max. [mA] 10000 6600 5000 4000 2500 1250 Output power max [W] 50 60 60 60 60 60 Efficiency @ full load typ. [%] 82 84 86 86 86 86 Output load capacitance max. [µF] 80000 28000 14000 12000 4000 1000 Stand by consumption max. [W] 0.5 0.5 0.5 0.5 0.5 0.5 Specification Input Voltage range Start up voltage Shut down voltage Line frequency range Full load input current Inrush current Recommended fuse Isolation Isolation voltage (input to output) Isolation voltage (input to PE) Isolation voltage (output to PE) Isolation resistance Output Voltage accuracy Line regulation Load regulation Load minimum Output voltage trim range Ripple & noise up to 20 MHz Temperature coefficient Minimum load Hold-up time Protection Short circuit Over current General Switching frequency Reliability MTBF@ 25 °C 90 VAC ~ 264 VAC 120 VDC.~.370 VDC 65 VAC ~ 90 VAC 92 VDC.~.122 VDC 55 VAC ~ 75 VAC 79 VDC.~.105 VDC 47…63 Hz 1400 mA @ 115 VAC, typ. 700 mA @ 230 VAC, typ. 30 A typ. @ 115 VAC 50 A typ. @ 230 VAC 3.15 A / 250V slow blow 4000 VAC tested for 1 min. 1500 VAC tested for 1 min. 500 VAC tested for 1 min. 8 10 Ω ±2% ± 0.5 % ± 1 %@ 5 %...100 % load 1% 10 % max. 150 mVpp max. (refer figure 2) ± 0.02 % / °C 1% 15 ms typ. @ 115 VAC 80 ms typ. @ 230 VAC Continuous, auto recovery 110 %, min. of full load 100 kHz typ. > 200000 h EMC compliance EMI: Conducted & Radiation ESD: Electrostatic discharge RS: field susceptibility EFT: Surge: without external circuit without external circuit with external circuit refer to figure 3 CS: PFM: Voltage dips, short and interruptions immunity Safety approvals Safety Class Environmental Operating ambient temperature Operating case temperature Storage temperature Storage humidity Cooling Physical Dimensions, PCB version Weight Case material Wave soldering temperature Manual soldering temperature Hot swap CE: EN55022 (CISPR22), class B RE: EN55022 (CISPR22), class B IEC-, EN61000-4-2, air ± 8 kV, contact ± 6 kV, perf. Criteria B IEC-, EN61000-4-3, 10 V/m, perf. Criteria A IEC-, EN61000-4-4, ± 2 kV, perf. Criteria B IEC, EN61000-4-5, ±2 kV / ± 4 kV, perf. Criteria B IEC, EN61000-4-5, ±4 kV / ± 6 kV, perf. Criteria B IEC, EN61000-4-6, 10 Vrms. perf. Criteria A IEC, EN61000-4-8, 10 A/m perf. Criteria A IEC, EN61000-4-11, 0...70 % perf. Criteria B EN60950, UL60950 Class I -40 °C to 70 °C, see derating diagram! 90°C, max. -40 °C to +85 °C 95 %, non-condensing Free air convection 109 x 58.5 x 30 mm 310 g UL94V-0 rated 260 ± 5 °C, 10 s max., 1.5 mm distance min. from case 360 ± 10 °C, 5 s max., 1.5 mm distance min. from case Not permissible! Page 1 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected] 60W AC-DC Power-Supply PAC60C Figure 1 Typical application circuit L F1 PAC60C R1 L D1 +Vout C2 Va U N C1 +Vo -Vout -Vo N C1 PE Figure 2 Output ripple & noise measure circuit Conductor track L +Vo AC AC or DC line input DC -Vo N 12.7 Figure 3 L F1 Oscilloscope probe 12.7 25.4 unit mm Application circuit and example for ripple and noise reduction R1 Vc L Vb - Va U U U GT Cx Rd +V out L1 Vb U N PAC60C05S PAC60C09S PAC60C12S PAC60C15S PAC60C24S PAC60C48S +V out Cy U C1 C2 D1 -V out -V out N Vc PE Model Cy C1 Cer. cap. [µF] 1 C2 El. cap. [µF] 680 470 330 330 200 100 F1 Fuse R1 NTC type Rd Va MOV Vb MOV Vc MOV type type type S14K350 S10K350 3.15 A 250 V~ 1 MΩ, 5D-14 S20K350 Slow 2W blow GT Gas Tube type B5G3600 D1 TVS type SMBJ7.0A SMBJ12A SMBJ20A SMBJ20A SMBJ30A SMBJ64A Cy Cx L1 400 V~ 300 V~ Com.mode [nF] [µF] [mH] 2.2 0.15 2.2 Note: 1. Output filtering capacitors C2 is a electrolytic capacitor. It is recommended to use high frequency and low impedance electrolytic capacitors. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80 % or above. C1 is ceramic capacitor. It is used to filter high frequency noise. TVS is a recommended component to protect post-circuits in case of a converter failure. 2. For standard EMC requirement, please refer to figure 1. If higher an EMC requirement, please refer to figure 2. Page 2 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected] 60W AC-DC Power-Supply PAC60C EMC optimized circuit PCB layout Figure 4 Recommended safety and EMC PCB layout: conductor track width > 3 mm, safety distance > 9 mm Application note for trim option Trim down circuit Trim up circuit +Vout PAC60C R1 +Vout PAC60C Rtd - - R3 + R1 R3 + R2 VRef Rtu R2 VRef -Vout -Vout Calculation for trim down resistor (Rtd) or trim up resistor (Rtu) Model series R1 [kΩ] R2 [kΩ] R3 [kΩ] V Ref [V] PAC60Cxx05S 3.3 3.3 1 2.5 PAC60Cxx09S 4.7 1.8 1 2.5 PAC60Cxx12S 3.83 1 1 2.5 PAC60Cxx15S 7.5 1.5 1 2.5 PAC60Cxx24S 8.66 1 1 2.5 PAC60Cxx48S 33 1.8 1 2.5 Maximum output voltage adjust range ±10 % of Vout nominal, see min. Rtd / Rtu Trim down resistor formula b= Vout-Vref Rtd= Vref R1*b R1-b Rtd min. [kΩ] 12.2 27.4 24 54 64 260 Rtu min. [kΩ] 15.5 12.5 7.5 11.5 8.62 17.5 Trim up resistor formula *R2 a= -R3 Vref Vout-Vref Rtu= R2*a R2-a *R1 -R3 Page 3 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected] 60W AC-DC Power-Supply PAC60C Page 4 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected] 60W AC-DC Power-Supply PAC60C Page 5 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected] 60W AC-DC Power-Supply PAC60C Dimensions Pin connection Pin 1 2 3 4 5 6 7 Pin configuration Input AC (L) Input AC (N) + V output No pin - V output No pin Trim input Unit: mm Pin diameter tolerance: ± 0.1 mm Pin length: > 6 mm General tolerances: ± 0.5 mm PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for use carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 03.16 f Page 6 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Hochstrasse 355 CH-8200 Schaffhausen Tel.: 052 647 42 00 E-Mail: [email protected]