Download

60W AC-DC Power-Supply PAC60C
●
●
●
●
●
●
●
PCB-mountable plastic case
AC and DC universal input
Continuously short circuit protected
Over current protected
Input under voltage protected
Safe isolation 4 kVAC
3 years product warranty
Model guide
Type
Output voltage Output voltage
tolerance
PAC60C05S
PAC60C09S
PAC60C12S
PAC60C15S
PAC60C24S
PAC60C48S
[VDC]
5
9
12
15
24
48
typ. [%]
±2
±2
±2
±2
±2
±2
Output
current
max.
[mA]
10000
6600
5000
4000
2500
1250
Output
power
max
[W]
50
60
60
60
60
60
Efficiency @
full load
typ.
[%]
82
84
86
86
86
86
Output load
capacitance
max.
[µF]
80000
28000
14000
12000
4000
1000
Stand by
consumption
max.
[W]
0.5
0.5
0.5
0.5
0.5
0.5
Specification
Input
Voltage range
Start up voltage
Shut down voltage
Line frequency range
Full load input current
Inrush current
Recommended fuse
Isolation
Isolation voltage (input to output)
Isolation voltage (input to PE)
Isolation voltage (output to PE)
Isolation resistance
Output
Voltage accuracy
Line regulation
Load regulation
Load minimum
Output voltage trim range
Ripple & noise up to 20 MHz
Temperature coefficient
Minimum load
Hold-up time
Protection
Short circuit
Over current
General
Switching frequency
Reliability MTBF@ 25 °C
90 VAC ~ 264 VAC
120 VDC.~.370 VDC
65 VAC ~ 90 VAC
92 VDC.~.122 VDC
55 VAC ~ 75 VAC
79 VDC.~.105 VDC
47…63 Hz
1400 mA @ 115 VAC, typ.
700 mA @ 230 VAC, typ.
30 A typ. @ 115 VAC
50 A typ. @ 230 VAC
3.15 A / 250V slow blow
4000 VAC tested for 1 min.
1500 VAC tested for 1 min.
500 VAC tested for 1 min.
8
10 Ω
±2%
± 0.5 %
± 1 %@ 5 %...100 % load
1%
10 % max.
150 mVpp max.
(refer figure 2)
± 0.02 % / °C
1%
15 ms typ. @ 115 VAC
80 ms typ. @ 230 VAC
Continuous, auto recovery
110 %, min. of full load
100 kHz typ.
> 200000 h
EMC compliance
EMI:
Conducted & Radiation
ESD: Electrostatic
discharge
RS: field susceptibility
EFT:
Surge:
without external
circuit
without external
circuit
with external
circuit refer to
figure 3
CS:
PFM:
Voltage dips, short and
interruptions immunity
Safety approvals
Safety Class
Environmental
Operating ambient
temperature
Operating case
temperature
Storage temperature
Storage humidity
Cooling
Physical
Dimensions, PCB version
Weight
Case material
Wave soldering
temperature
Manual soldering
temperature
Hot swap
CE: EN55022 (CISPR22), class B
RE: EN55022 (CISPR22), class B
IEC-, EN61000-4-2, air ± 8 kV,
contact ± 6 kV, perf. Criteria B
IEC-, EN61000-4-3, 10 V/m,
perf. Criteria A
IEC-, EN61000-4-4, ± 2 kV,
perf. Criteria B
IEC, EN61000-4-5, ±2 kV /
± 4 kV, perf. Criteria B
IEC, EN61000-4-5, ±4 kV /
± 6 kV, perf. Criteria B
IEC, EN61000-4-6, 10 Vrms.
perf. Criteria A
IEC, EN61000-4-8, 10 A/m
perf. Criteria A
IEC, EN61000-4-11, 0...70 %
perf. Criteria B
EN60950, UL60950
Class I
-40 °C to 70 °C,
see derating diagram!
90°C, max.
-40 °C to +85 °C
95 %, non-condensing
Free air convection
109 x 58.5 x 30 mm
310 g
UL94V-0 rated
260 ± 5 °C, 10 s max.,
1.5 mm distance min. from case
360 ± 10 °C, 5 s max.,
1.5 mm distance min. from case
Not permissible!
Page 1 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
60W AC-DC Power-Supply PAC60C
Figure 1
Typical application circuit
L
F1
PAC60C
R1
L

D1 +Vout
C2
Va
U
N
C1
+Vo
-Vout
-Vo
N
C1
PE
Figure 2
Output ripple & noise measure circuit
Conductor track
L
+Vo
AC
AC or DC
line input
DC
-Vo
N
12.7
Figure 3
L
F1
Oscilloscope probe
12.7
25.4
unit mm
Application circuit and example for ripple and noise reduction
R1
Vc
L
Vb
-
Va
U
U
U
GT
Cx
Rd
+V out
L1
Vb
U
N
PAC60C05S
PAC60C09S
PAC60C12S
PAC60C15S
PAC60C24S
PAC60C48S
+V out
Cy
U
C1
C2
D1
-V out
-V out
N
Vc
PE
Model
Cy
C1
Cer.
cap.
[µF]
1
C2
El.
cap.
[µF]
680
470
330
330
200
100
F1
Fuse
R1
NTC
type
Rd
Va
MOV
Vb
MOV
Vc
MOV
type
type
type
S14K350
S10K350
3.15 A
250 V~
1 MΩ,
5D-14
S20K350
Slow
2W
blow
GT
Gas Tube
type
B5G3600
D1
TVS
type
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
SMBJ64A
Cy
Cx
L1
400 V~ 300 V~ Com.mode
[nF]
[µF]
[mH]
2.2
0.15
2.2
Note:
1. Output filtering capacitors C2 is a electrolytic capacitor. It is recommended to use high frequency and low impedance electrolytic
capacitors. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should
be 80 % or above. C1 is ceramic capacitor. It is used to filter high frequency noise. TVS is a recommended component to protect
post-circuits in case of a converter failure.
2. For standard EMC requirement, please refer to figure 1. If higher an EMC requirement, please refer to figure 2.
Page 2 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
60W AC-DC Power-Supply PAC60C
EMC optimized circuit PCB layout
Figure 4
Recommended safety and EMC PCB layout: conductor track width > 3 mm, safety distance > 9 mm
Application note for trim option
Trim down circuit
Trim up circuit
+Vout
PAC60C
R1
+Vout
PAC60C
Rtd
-
-
R3
+
R1
R3
+
R2
VRef
Rtu
R2
VRef
-Vout
-Vout
Calculation for trim down resistor (Rtd) or trim up resistor (Rtu)
Model series
R1 [kΩ]
R2 [kΩ]
R3 [kΩ]
V Ref [V]
PAC60Cxx05S
3.3
3.3
1
2.5
PAC60Cxx09S
4.7
1.8
1
2.5
PAC60Cxx12S
3.83
1
1
2.5
PAC60Cxx15S
7.5
1.5
1
2.5
PAC60Cxx24S
8.66
1
1
2.5
PAC60Cxx48S
33
1.8
1
2.5
Maximum output voltage adjust range ±10 % of Vout nominal, see min. Rtd / Rtu
Trim down resistor formula
b=
Vout-Vref
Rtd=
Vref
R1*b
R1-b
Rtd min. [kΩ]
12.2
27.4
24
54
64
260
Rtu min. [kΩ]
15.5
12.5
7.5
11.5
8.62
17.5
Trim up resistor formula
*R2
a=
-R3
Vref
Vout-Vref
Rtu=
R2*a
R2-a
*R1
-R3
Page 3 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
60W AC-DC Power-Supply PAC60C
Page 4 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
60W AC-DC Power-Supply PAC60C
Page 5 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
60W AC-DC Power-Supply PAC60C
Dimensions
Pin connection
Pin
1
2
3
4
5
6
7
Pin configuration
Input AC (L)
Input AC (N)
+ V output
No pin
- V output
No pin
Trim input
Unit: mm
Pin diameter tolerance: ± 0.1 mm
Pin length: > 6 mm
General tolerances: ± 0.5 mm
PHI-CON is a trademark of HY-LINE Holding GmbH.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for
use carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to
result in significant injury to the user. Rev: 03.16 f
Page 6 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]