Data Sheet 1.2 A Programmable Device Power Supply with Integrated 16-Bit Level Setting DACs AD5560 FEATURES Programmable device power supply (DPS) FV, MI, MV, FNMV functions 5 internal current ranges (on-chip RSENSE) ±5 µA, ±25 µA, ±250 µA, ±2.5 mA, ±25 mA 2 external high current ranges (external RSENSE) EXTFORCE1: ±1.2 A maximum EXTFORCE2: ±500 mA maximum Integrated programmable levels All 16-bit DACs: force DAC, comparator DACs, clamp DACs, offset DAC, OSD DAC, DGS DAC Programmable Kelvin clamp and alarm Offset and gain correction registers on-chip Ramp mode on force DAC for power supply slewing Programmable slew rate feature, 1 V/μs to 0.3 V/μs DUTGND Kelvin sense and alarm 25 V FV span with asymmetrical operation within −22 V/+25 V On-chip comparators Gangable for higher current Guard amplifier System PMU connections Current clamps Die temperature sensor and shutdown feature On-chip diode thermal array Diagnostic register allows access to internal nodes Open-drain alarm flags (temperature, current clamp, Kelvin alarm) SPI-/MICROWIRE-/DSP-compatible interface 64-lead (10 mm × 10 mm) TQFP with exposed pad (on top) 72-ball (8 mm × 8 mm) flip-chip BGA APPLICATIONS Automatic test equipment (ATE) Device power supply GENERAL DESCRIPTION The AD5560 is a high performance, highly integrated device power supply consisting of programmable force voltages and measure ranges. This part includes the required DAC levels to set the programmable inputs for the drive amplifier, as well as clamping and comparator circuitry. Offset and gain correction is included on-chip for DAC functions. A number of programmable measure current ranges are available: five internal fixed ranges and two external customer-selectable ranges (EXTFORCE1 and EXTFORCE2) that can supply currents up to ±1.2 A and ±500 mA, respectively. The voltage range possible at this high current level is limited by headroom and the maximum power dissipation. Current ranges in excess of ±1.2 A or at high current and high voltage combinations can be achieved by paralleling or ganging multiple DPS devices. Open-drain alarm outputs are provided in the event of overcurrent, overtemperature, or Kelvin alarm on either the SENSE or DUTGND line. The DPS functions are controlled via a simple 3-wire serial interface compatible with SPI, QSPI™, MICROWIRE™, and DSP interface standards running at clock speeds of up to 50 MHz. Rev. D Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 www.analog.com Fax: 781.461.3113 ©2008-2012 Analog Devices, Inc. All rights reserved. AD5560 Data Sheet TABLE OF CONTENTS Features .............................................................................................. 1 Adjusting the Autocompensation Mode ................................. 39 Applications ....................................................................................... 1 Dealing with Parallel Load Capacitors .................................... 39 General Description ......................................................................... 1 DAC Levels .................................................................................. 39 Revision History ............................................................................... 3 Force and Comparator DACs ................................................... 39 Functional Block Diagram .............................................................. 4 Clamp DACs ............................................................................... 39 Specifications..................................................................................... 5 OSD DAC .................................................................................... 40 Timing Characteristics .............................................................. 13 DUTGND DAC .......................................................................... 40 Timing Diagrams........................................................................ 13 Offset DAC .................................................................................. 40 Absolute Maximum Ratings .......................................................... 15 Offset and Gain Registers.......................................................... 40 ESD Caution ................................................................................ 15 Reference Selection .................................................................... 41 Pin Configurations and Function Descriptions ......................... 16 Choosing AVDD/AVSS Power Supply Rails ............................... 41 Typical Performance Characteristics ........................................... 20 Choosing HCAVSSx and HCAVDDx Supply Rails ................... 41 Terminology .................................................................................... 28 Power Dissipation....................................................................... 41 Theory of Operation ...................................................................... 29 Package Composition and Maximum Vertical Force ............ 42 Force Amplifier ........................................................................... 29 Slew Rate Control ....................................................................... 42 DAC Reference Voltage (VREF) ............................................... 29 Serial Interface ................................................................................ 44 Open-Sense Detect (OSD) Alarm and Clamp ....................... 29 SPI Interface ................................................................................ 44 Device Under Test Ground (DUTGND)................................. 29 SPI Write Mode .......................................................................... 44 GPO .............................................................................................. 30 SDO Output ................................................................................ 44 Comparators................................................................................ 30 RESET Function ......................................................................... 44 Current Clamps .......................................................................... 30 BUSY Function ........................................................................... 44 Short-Circuit Protection ............................................................ 30 LOAD Function .......................................................................... 44 Guard Amplifier ......................................................................... 30 Register Update Rates ................................................................ 45 Compensation Capacitors ......................................................... 30 Control Registers ............................................................................ 46 Current Range Selection ............................................................ 31 DPS and DAC Addressing ........................................................ 46 High Current Ranges ................................................................. 31 Readback Mode .......................................................................... 57 Ideal Sequence for Gang Mode ................................................. 32 DAC Readback............................................................................ 57 Compensation for Gang Mode ................................................. 32 Power-On Default ...................................................................... 57 System Force/Sense Switches .................................................... 32 Using the HCAVDDx and HCAVSSx Supplies .......................... 59 Die Temperature Sensor and Thermal Shutdown.................. 33 Power Supply Sequencing ......................................................... 59 Measure Output (MEASOUT) ................................................. 33 Required External Components ............................................... 60 VMID Voltage ................................................................................ 33 Power Supply Decoupling ......................................................... 61 Force Amplifier Stability............................................................ 36 Applications Information .............................................................. 62 Poles and Zeros in a Typical System ........................................ 37 Thermal Considerations............................................................ 62 Minimizing the Number of External Compensation Components ................................................................................ 37 Temperature Contour Map on the Top of the Package ......... 63 Extra Poles and Zeros in the AD5560...................................... 37 Compensation Strategies ........................................................... 38 Outline Dimensions ....................................................................... 64 Ordering Guide .......................................................................... 65 Optimizing Performance for a Known Capacitor Using Autocompensation Mode .......................................................... 38 Rev. D | Page 2 of 68 Data Sheet AD5560 REVISION HISTORY 8/12—Rev. C to Rev. D 12/08—Rev. 0 to Rev. A Added 72-Ball Flip-Chip BGA (Throughout) ............................... 1 Added Figure 7 and Table 5 (Renumbered Sequentially) ..........18 Added Applications Information Section ....................................62 Updated Outline Dimensions ........................................................64 Changes to Ordering Guide ...........................................................65 Changes to Figure 1 .......................................................................... 4 Changes to Table 1 ............................................................................ 4 Changes to Table 2 .......................................................................... 13 Changes to Table 3 .......................................................................... 15 Changes to Open-Sense Detect (OSD) Alarm and Clamp ....... 27 Changes to Figure 53 ...................................................................... 30 Change to gm Maximum Rating, Table 13 .................................. 34 Changes to Table 19 ........................................................................ 46 Changes to Bit 7, Bit 8 Functions, Table 21 ................................. 48 Changes to Power Supply Decoupling Section ........................... 59 10/10—Rev. B to Rev. C Changes to Force Output Voltage Parameter and Load Transient Response Parameter, Table 1............................................................ 5 Changes to Figure 52 ......................................................................29 Changes to Table 9 ..........................................................................32 9/09—Rev. A to Rev. B 11/08—Revision 0: Initial Version Changes to Table 1, Measure Current and Measure Voltage Parameters .......................................................................................... 6 Changes to Die Temperature Sensor and Thermal Shutdown Section ............................................................................31 Changes to Table 10 and Table 11 .................................................32 Changes to Table 18, Bit 15 ............................................................45 Changes to Table 23, Bits[15:12] ...................................................50 Changes to Table 25 ........................................................................54 Rev. D | Page 3 of 68 Figure 1. Rev. D | Page 4 of 68 VREF SW16 MEASOUT RESET GPO 16 16 16 OFFSET OFFSET 16-BIT DAC ISENSE VSENSE KSENSE TSENSE DUTGND SENSE DIAGNOSTIC A DIAGNOSTIC B ×2 REG ×2 REG 16-BIT DAC SDO SCLK SDI SYNC BUSY SERIAL SPI INTERFACE ×1/×0.2 MUX AND GAIN ×8 ×8 S/W INH R3 OFFSET 16-BIT DAC OFFSET SW3 A B TMPALM DIE TEMP SENSOR AND THERMAL SHUTDOWN R4 FIN CLAMP OFFSET CONTROL CLH 16-BIT DAC THERMAL SHUTDOWN R2 16 16 16 CLH CLEN/ LOAD CLALM CPL ×1 REG M REG C REG ×1 REG M REG C REG AGND R1 CLH DAC OFFSET DAC CLH 16-BIT ×2 REG ×2 REG ×2 REG 16-BIT DAC DGND CPOL POWER-ON RESET ×1 ×1 RAMP REG ×1 REG M REG C REG ×1 ×1 REG M REG C REG ×1 REG M REG C REG DVCC CPH 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 AVDD CPOH/ CPO HW_INH/LOAD RCLK REFGND AGND B A SW1 C C VREF SW2 A B 6kΩ VREF 16 AGND VSENSE ISENSE 16 OSD DAC ×1 – + ×10 + OR ×20 – DAC MID CODE VOLTAGE TO CENTER IRANGE LOCAL FEEDBACK EXTFORCE1 EXTFORCE2 SLEW RATE CONTROL gm 40µA/V 80µA/V 400µA/V 1000µA/V RZ: 500Ω TO 1.6MΩ CC0 CC1 CC2 CC3 25kΩ DGS DAC RP: 200Ω TO 1MΩ 100kΩ + – + – + – + – SW4 KELALM ALARM BLOCK KSENSE DUTGND SENSE GUARD DUTGND SENSE AND ALARM INHIBIT OPEN SENSE DETECT 8pF RSENSE SW7 25mA SW17 5µA 25µA 250µA 2.5mA AD5560 GUARD AMP SW15 SW14 SW13 100kΩ 20kΩ 2kΩ 200Ω 20Ω SW5a SW5b HCAVDD1x HCAVSS1x HCAVSS2x HCAVDD2x SW18 SW9 10kΩ SW11 SW8 UP TO ±500mA UP TO ±1.2A MUX SW6 DUTGND GUARD/ SYS_DUTGND SENSE EXTMEASIL EXTMEASIH2 EXTMEASIH1 SYS_SENSE FORCE SYS_FORCE CF0 TO CF4 EXTFORCE2 EXTFORCE1 CF0 TO CF4 MASTER_OUT SLAVE_IN DUT EXT RSENSE2 EXT RSENSE1 07779-001 AVSS AD5560 Data Sheet FUNCTIONAL BLOCK DIAGRAM Data Sheet AD5560 SPECIFICATIONS HCAVDDx ≤ (AVSS + 33 V), HCAVDDx ≤ AVDD, HCAVSSx ≥ AVSS, AVDD ≥ 8 V, AVSS ≤ −5 V, |AVDD − AVSS| ≥ 16 V and ≤ 33 V, DVCC = 2.3 V to 5.5 V, VREF = 5 V, gain (m), offset (c), and DAC offset registers are at default values; AGND = DGND = 0 V; TJ = 25°C to 90°C, maximum specifications, unless otherwise noted. FSV is full-scale voltage, FSVR is full-scale voltage range, FSC is full-scale current, FSCR is full-scale current range. Table 1. Parameter FORCE VOLTAGE Force Output Voltage 1 EXTFORCE1 Max Unit Test Conditions/Comments AVSS + 2.25 HCAVSS1x + 1.75 HCAVSS1x + 1.25 AVDD − 2.25 HCAVSS1x − 1.75 HCAVDD1x − 1.25 V V V EXTFORCE2 AVSS + 2.25 HCAVSS2x + 1.75 HCAVSS2x + 1.25 AVDD − 2.25 HCAVDD2x − 1.75 HCAVDD2x − 1.25 V V V FORCE AVSS + 2.75 AVDD − 2.75 V Headroom/Footroom1 −2.75 +2.75 V Headroom/Footroom1 −2.25 +2.25 V Force Output Voltage Span −22 +25 V Allow ±500 mV for external RSENSE voltage drop. Allow ±500 mV for external RSENSE voltage drop. Allow ±500 mV for external RSENSE voltage drop. Reduced headroom/footroom, clamps must be enabled. 2 Allow ±500 mV for external RSENSE voltage drop Allow ±500 mV for external RSENSE voltage drop Allow ±500 mV for external RSENSE voltage drop. Reduced headroom/footroom, clamps must be enabled.2 Internal current ranges, includes ±500 mV for internal RSENSE voltage drop Internal current ranges to AVDD/AVSS, includes ±500 mV for internal RSENSE voltage drop. External current ranges, EXTFORCE1/ EXTFORCE2 to HCAVDDx and HCAVSSx supplies; includes ±500 mV for external RSENSE voltage drop. May be a skewed range but within headroom requirements and maximum power dissipation for current range. Forced Voltage Linearity Error Forced Voltage Offset Error −2 −50 +2 +50 mV mV +25 μV/°C mV ppm/°C Forced Voltage Offset Error Tempco1 Forced Voltage Gain Error Forced Voltage Gain Error Tempco1 Short-Circuit Current Limit3 EXTFORCE1 EXTFORCE2 FORCE Min Typ 27 −25 4 −3.5 −1.25 −75 ±2.7 ±0.9 ±50 +3.5 +1.25 +75 A A mA −20 ±10 +20 mA +64 +1 +0.4 70 mA mV mV mV 140 mV NSD1 MEASURE CURRENT RANGES 350 nV/√Hz Internal Sense Resistors1 100 20 2 200 20 kΩ kΩ kΩ Ω Ω Active CFx Buffer DC Load Regulation1 Load Transient Response1 −64 −1 −0.4 Rev. D | Page 5 of 68 Uncalibrated, use c register to calibrate, measured at midscale. Standard deviation = 23 μV/°C. Uncalibrated, use m register to calibrate. Standard deviation = 3 ppm/°C. Clamps off. Positive and negative dc short-circuit current. Positive and negative dc short-circuit current. ±25 mA range, positive and negative dc shortcircuit current. All other ranges, positive and negative dc short-circuit current. EXTFORCE1 range, ±1 A load current change. EXTFORCE2 range, ±0.5 A load current change. 1.2 A load step into 100 μF DUT capacitance (10 mΩ ESR), autocompensation mode. 1.2 A load step into 30 µF DUT capacitance (10 mΩ ESR), autocompensation mode. Measured at 1 kHz, at output of FORCE. Sense resistors are trimmed to within 1%, nominal ±500 mV VRSENSE. ±5 µA current range. ±25 µA current range. ±250 µA current range. ±2.5 mA current range. ±25 mA current range. AD5560 Parameter Measure Current Ranges Data Sheet Min Typ Max Unit ±5 ±25 ±250 ±2.5 ±25 ±500 µA µA µA mA mA mA ±120 0 mA MEASURE CURRENT Differential Input Voltage Range1 Output Voltage Span1 Offset Error Offset Error Tempco1 Offset Error Offset Error Tempco1 Offset Error Offset Error Tempco1 Offset Error Offset Error Tempco1 Gain Error Gain Error1 Gain Error Tempco1 MEASOUT Gain = 1 Linearity Error MEASOUT Gain = 0.2 Linearity Error Linearity Error MEASOUT Gain = 0.2 Linearity Error Linearity Error MEASOUT Gain = 0.2 Linearity Error Linearity Error Common-Mode Error −0.64 −0.7 25 −1 +1 −1 −1.5 +1.5 −1 −1.5 +1.5 3 −3 +3 8 −2 −1 +2 +1 20 V V V % FSC ppm of FSC/°C % FSC ppm of FSC/°C % FSC ppm of FSC/°C % FSC ppm of FSC/°C % FSC % FSC ppm/°C −0.01 +0.01 % FSCR −0.06 −0.05 +0.06 +0.05 % FSCR % FSCR −0.125 −0.175 +0.125 +0.175 % FSCR % FSCR −0.0875 −0.1 −0.005 +0.0875 +0.1 +0.005 % FSCR % FSCR %FSVR/V NSD1 MEASURE VOLTAGE Measure Voltage Range1 Gain Error Gain Error Tempco1 MEASOUT Gain = 1 Linearity Error Offset Error Offset Error Tempco1 NSD1 +0.64 +0.7 900 nV/√Hz 550 nV/√Hz 170 nV/√Hz 110 nV/√Hz AVSS + 2.75 −0.1 AVDD − 2.75 +0.1 3 −2 −12 +2 +12 2 100 Rev. D | Page 6 of 68 V % FS ppm/°C mV mV µV/°C nV/√Hz Test Conditions/Comments Specified current ranges with VREF = 5 V and MI gain = 20, or with VREF = 2.5 V and MI gain = 5. Set using internal sense resistor. Set using internal sense resistor. Set using internal sense resistor. Set using internal sense resistor. Set using internal sense resistor. EXTFORCE2, set by user with external sense resistor, limited by headroom requirements and maximum power dissipation. EXTFORCE1, set by user with external sense resistor, limited by headroom requirements and maximum power dissipation. All offset DAC/supply combinations settings, all gain settings are measure current = (IDUT × RSENSE × MI gain), unless otherwise noted. Maximum voltage across RSENSE, MI gain = 20. Maximum voltage across RSENSE, MI gain = 10. Measure current block alone (internal node). At 0 A, MI gain = 20, MEASOUT gain = 1. Standard deviation = 13 ppm/°C. At 0 A, MI gain = 10, MEASOUT gain = 1. Standard deviation = 13 ppm/°C. At 0 A, MI gain = 20, MEASOUT gain = 0.2. Standard deviation = 13 ppm/°C. At 0 A, MI gain = 10, MEASOUT gain = 0.2. Standard deviation = 15 ppm/°C. Internal current ranges, all gain settings. External current ranges, excluding RSENSE. Standard deviation = 5 ppm/°C. All supply conditions. MI gain = 20 and 10. Nominal supply (±16.5 V, 0x8000 offset DAC). MI gain = 20. MI gain = 10. Low supply (−25 V/+8 V, 0xD4EB offset DAC). MI gain = 20. MI gain = 10. High supply (−5 V/+28 V, 0xD1D offset DAC). MI gain = 20. MI gain = 10. % of FS change at measure output per volts change in DUT voltage. MI gain = 20, MEASOUT gain = 1, measured at MEASOUT @ 1 kHz, inputs grounded. MI gain = 10, MEASOUT gain = 1, measured at MEASOUT @ 1 kHz, inputs grounded. MI gain = 20, MEASOUT gain = 0.2, measured at MEASOUT @ 1 kHz, inputs grounded. MI gain = 10, MEASOUT gain = 0.2, measured at MEASOUT @ 1 kHz, inputs grounded. MEASOUT Gain 1 and MEASOUT Gain 0.2. All voltage ranges. Standard deviation = 2 ppm/°C. Standard deviation = 12 µV/°C. @ 1 kHz, at MEASOUT, inputs grounded. Data Sheet Parameter MEASOUT Gain = 0.2 Linearity Error Offset Error Offset Error Tempco1 AD5560 Min Max Unit Test Conditions/Comments −5.5 +5.5 mV −9 +24 mV −4 +13 mV +20 10 mV µV/°C 50 nV/√Hz Referred to MV input, nominal supply (±16.5 V, 0x8000 offset DAC). Referred to MV input, low supply (−25 V/+8 V, 0xD4EB offset DAC). Referred to MV input, high supply (−5 V/+28 V, 0xD1D offset DAC). Referred to MV output. Standard deviation = 12 µV/°C, referred to MV output. @ 1 kHz, at MEASOUT, inputs grounded. Includes SYS_SENSE, SYS_FORCE, EXTFORCE1, EXTFORCE2, EXTMEASIH1, EXTMEASIH2, EXTMEASIL, FORCE, and SENSE; measured with PD = 1, SW-INH = 0 (power up and tristate). −30 NSD1 COMBINED LEAKAGE Leakage Current Leakage Current Tempco1 SENSE INPUT Leakage Current −37.5 −30 ±0.1 −2.5 Leakage Current Tempco1 Pin Capacitance1 EXTMEASIH1, EXTMEASIH2, EXTMEASIL Leakage Current −2.5 Leakage Current Leakage Current Path On Resistance Pin Capacitance1 nA nA pF mA nA pF mA −7.5 +7.5 nA ±0.06 nA/°C Set with external sense resistor, limited by headroom and power dissipation. Measured with PD = 1, SW-INH = 0 (power-up and tristate). pF −500 +500 mA −5 +5 nA ±0.05 nA/°C ±0.0 05 Measured with PD = 1, SW-INH = 0 (power-up and tristate). nA/°C +1200 AVSS −2.5 Measured with PD = 1, SW-INH = 0 (power-up and tristate). nA/°C −1200 ±0.0 2 100 Measured with PD = 1, SW-INH = 0 (power-up and tristate). pF +30 +10 ±0.0 3 275 TJ = 25°C to 70°C. nA/°C ±0.0 3 120 Leakage Current Tempco1 Pin Capacitance1 SYS_SENSE Voltage Range Leakage Current Leakage Current Tempco1 +2.5 +2.5 −30 −10 Leakage Current Tempco1 Pin Capacitance1 EXTFORCE2 OUTPUTS Maximum Current Drive1 nA nA nA/°C ±0.0 1 5 Leakage Current Tempco1 Pin Capacitance1 EXTFORCE1 OUTPUTS Maximum Current Drive1 +37.5 +30 ±0.4 ±0.0 1 10 Leakage Current Tempco1 Pin Capacitance1 FORCE OUTPUT, FORCE Maximum Current Drive1 Leakage Current Typ Set with external sense resistor, limited by headroom and power dissipation. Measured with PD = 1, SW-INH = 0 (power-up and tristate). pF AVDD +2.5 ±0.025 V nA nA/°C 280 Ω pF 5 Rev. D | Page 7 of 68 SYS_SENSE high-Z, force amplifier inhibited. AVDD = 16.5 V, AVSS = −16.5 V. AD5560 Parameter SYS_FORCE Voltage Range Current Carrying Capability1 Leakage Current Leakage Current Tempco1 Path On Resistance Pin Capacitance1 SYS_DUTGND Voltage Range Path On Resistance CURRENT CLAMP Clamp Accuracy Data Sheet Min Typ AVSS −25 −2.5 ±0.00 5 Max Unit AVDD +25 +2.5 ±0.025 V mA nA nA/°C 35 Ω pF AVDD 400 V Ω Programmed clamp value + 10 Programmed clamp value + 20 % of FS 5 AVSS 300 VCLL to VCLH1 Programmed clamp value Programmed clamp value 2 VCLL to 0 A1 1 V VCLH to 0 A1 1 V % of FS V Test Conditions/Comments SYS_FORCE high-Z, force amplifier inhibited. AVDD = 16.5 V, AVSS = −16.5 V. AVDD = 16.5 V, AVSS = −16.5 V. MI gain = 20, with clamp separation of 2 V, and 1 V separation from AGND/0 A. MI gain = 10, with clamp separation of 2 V, and 1 V separation from AGND/0 A. 10% of FSCR (MI gain = 20), 20% of FSCR (MI gain = 10), restriction to prevent both clamps activating together. 5% of FSCR (MI gain = 20), 10% of FSCR (MI gain = 10), restriction to avoid impinging on FV before programmed level. 5% of FSCR (MI gain 20), 10% of FSCR (MI gain = 10), restriction to avoid impinging on FV before programmed level. Measured from BUSY going low to visible clamping. Measured from BUSY going low to visible recovery. Time for CLALM to flag. Clamp Activation Response Time1 20 100 μs Clamp Recovery1 2 5 μs Alarm Delay 1 50 μs 1 0.312 V/µs V/µs µF % Fastest slew rate, controlled via serial interface. Slowest slew rate, controlled via serial interface. µs µs µs µs µs µs µs µs 3.7 V step, RDUT = 2.4 Ω, CDUT = 0.22 µF, full dc load. 8 V step, RDUT = 8.8 Ω, CDUT = 0.22 µF, full dc load. 15 V step, RDUT = 30 Ω, CDUT = 0.22 µF, full dc load. 10 V step, RDUT = 33.3 Ω, CDUT = 0.22 µF, full dc load. 20 V step, RDUT = 800 Ω, CDUT = 0.22 µF, full dc load. 10 V step, RDUT = 4 kΩ, CDUT = 0.22 µF, full dc load. 10 V step, RDUT = 40 kΩ, CDUT = 0.22 µF, full dc load. 10 V step, RDUT = 400 kΩ, CDUT = 0.22 µF, full dc load. 1 V step, RDUT = 200 kΩ, CDUT = 0.22 µF, full dc load. µs µs 3 V step, CDUT = 2.2 µF, full dc load. 8 V step, CDUT = 2.2 µF, full dc load. µs µs 3 V step, CDUT = 10 µF, full dc load. 8 V step, CDUT = 10 µF, full dc load. µs µs 3 V step, CDUT = 20 µF, full dc load. 8 V step, CDUT = 20 µF, full dc load. FORCE AMPLIFER Slew Rate1 Maximum Stable Load Capacitance1 Voltage Overshoot/Undershoot1 SETTLING TIME (FORCE AMPLIFER) FV (1200 mA EXTFORCE1 Range)1 FV (900 mA EXTFORCE1 Range)1 FV (500 mA EXTFORCE2 Range)1 FV (300 mA EXTFORCE2 Range)1 FV (25 mA Range)1, 3 FV (2.5 mA Range)1, 3 FV (250 µA Range)1, 3 FV (25 µA Range)1, 3 FV (5 µA Range)1, 3 FV (180 mA EXTFORCE1 Range)1 FV (100 mA EXTFORCE2 Range)1 FV (180 mA EXTFORCE1 Range)1 FV (100 mA EXTFORCE2 Range)1 FV (180 mA EXTFORCE1 Range)1 FV (100 mA EXTFORCE2 Range)1 160 5 Compensation Register 1 = 0x4880 (229 nF to 380 nF, ESR 74 to 140 mΩ) 16 25 18 30 34 53 25 50 125 180 300 500 300 500 400 600 20 40 Compensation Register 1 = 0x8880 (1.7 μF to 2.9 μF, ESR 74 to 140 mΩ) 16 25 60 80 Compensation Register 1 = 0xB880 (7.9μF to 13 μF, ESR 74 to 140 mΩ) 55 70 210 260 Compensation Register 1 = 0xC880 (13 μF to 22 μF, ESR 74 to 140 mΩ) 65 80 310 370 Rev. D | Page 8 of 68 µs Of programmed value (≥1 V). To within 10 mV of programmed value. Data Sheet Parameter SETTLING TIME (FV, MEASURE CURRENT) MI (1200 mA EXTFORCE1 Range)1 MI (900 mA EXTFORCE1 Range)1 MI (500 mA EXTFORCE2 Range)1 AD5560 Min Typ Max Compensation Register 1 = 0x4880 (229 nF to 380 nF, ESR 74 to 140 mΩ) 30 40 32 42 69 95 Unit Test Conditions/Comments To within 10 mV of programmed value. µs µs µs 3.7 V step, RDUT = 2.4 Ω, CDUT = 0.22 µF, full dc load. 8 V step, RDUT = 8.8 Ω, CDUT = 0.22 µF, full dc load. 15 V step, RDUT = 30 Ω, CDUT = 0.22 µF, full dc load. 10 V step, RDUT = 33.3 Ω, CDUT = 0.22 µF, full dc load. 20 V step, RDUT = 800 Ω, CDUT = 0.22 µF, full dc load. 10 V step, RDUT = 4 kΩ, CDUT = 0.22 µF, full dc load. 0.5 V step using MEASOUT high-Z to within 10 mV of final value. To within 10 mV of programmed value. MI (300 mA EXTFORCE2 Range)1 MI (25 mA Range)1, 3 MI (2.5 mA Range)1, 3 70 650 6400 100 µs µs µs MI Buffer Alone1 10 15 µs SETTLING TIME (FV, MEASURE VOLTAGE) MV (1200 mA Range)1 MV (900 mA Range)1 MV (500 mA Range)1 Compensation Register 1 = 0x4880 (229 nF to 380 nF, ESR 74 to 140 mΩ) 16 20 34 µs µs µs MV (300 mA Range)1 MV (25 mA Range)1, 3 MV (2.5 mA Range)1, 3 25 125 300 180 500 µs µs µs MV (250 µA Range)1, 3 MV Buffer Alone1 300 2 500 5 µs µs SETTLING TIME (FV) SAFE MODE FV (1200 mA EXTFORCE1 Range1 FV (180 mA EXTFORCE1 Range)1 25 303 µs µs FV (100 mA EXTFORCE2 Range)1 660 µs FV (25 mA Range)1, 3 SWITCHING TRANSIENTS Range Change Transient1 760 1000 µs 0.5 % of FV 20 DAC SPECIFICATIONS Force/Comparator/Offset DACs Resolution Voltage Output Span Differential Nonlinearity1 Offset DAC Gain Error Clamp DAC Resolution Voltage Output Span Differential Nonlinearity1 OSD DAC Resolution Voltage Output Span Differential Nonlinearity1 DGS DAC Resolution Voltage Output Span Differential Nonlinearity1 mV 3.7 V step, RDUT = 2.4 Ω, CDUT = 0.22 µF, full dc load. 8 V step, RDUT = 8.8 Ω, CDUT = 0.22 µF, full dc load. 15 V step, RDUT = 30 Ω, CDUT = 0.22 µF, full dc load. 10 V step, RDUT = 33.3 Ω, CDUT = 0.22 µF, full dc load. 20 V step, RDUT = 800 Ω, CDUT = 0.22 µF, full dc load. 10 V step, RDUT = 4 kΩ, CDUT = 0.22 µF, full dc load. 10 V step, RDUT = 40 kΩ, CDUT = 0.22 µF, full dc load. 10 V step using MEASOUT high-Z to within 10 mV of final value. To within 100 mV of programmed value. 3.7 V step, RDUT = 3.1 Ω, CDUT = 0.22 µF, full dc load. 3 V step, RDUT = 16 Ω, CDUT = 0. 22 µF to 20 μF, full dc load. 8 V step, RDUT = 33.3 Ω, CDUT = 0. 22 µF to 20 μF, full dc load. 20 V step, RDUT = 400 Ω, CDUT = 0.22 µF, full dc load. CDUT = 10 μF, changing from higher to adjacent lower ranges (except EXTFORCE1 to EXTFORCE2). CDUT = 10 μF, changing from lower (5 µA) to higher range (EXTFORCE1). CDUT = 100 μF, changing between all ranges. 0.5 % of FV −22 +25 Bits V −1 +1 LSB −20 +20 mV −22 +25 Bits V −1 +1 LSB 5 +2 Bits V LSB VREF = 5 V. 5 +2 Bits V LSB VREF = 5 V. 16 VREF = 5 V, minimum and maximum values set by offset DAC. Guaranteed monotonic. CLL < CLH. 16 16 0.62 −2 16 0 −2 Rev. D | Page 9 of 68 VREF = 5 V, minimum and maximum values set by offset DAC. Guaranteed monotonic. AD5560 Parameter Comparator DAC Dynamic Output Voltage Settling Time1 Slew Rate1 Digital-to-Analog Glitch Energy1 Glitch Impulse Peak Amplitude1 REFERENCE INPUT VREF DC Input Impedance VREF Input Current VREF Range1 COMPARATOR Error VOLTAGE COMPARATOR Propagation Delay1 Error1 CURRENT COMPARATOR Propagation Delay1 Error1 MEASURE OUTPUT, MEASOUT Measure Output Voltage Span1 Measure Output Voltage Span1 Measure Output Voltage Span1 Measure Output Voltage Span1 Measure Pin Output Impedance Output Leakage Current Output Capacitance1 Short-Circuit Current1 OPEN-SENSE DETECT/CLAMP/ALARM Measurement Accuracy Clamp Accuracy Alarm Delay1 DUTGND Voltage Range1 Pull-Up Current Leakage Current Trip Point Accuracy Alarm Delay1 GUARD AMPLIFIER Voltage Range1 Voltage Span1 Output Offset Short-Circuit Current1 Load Capacitance1 Output Impedance Alarm Delay1 DIE TEMPERATURE SENSOR Accuracy1 Output Voltage at 25°C Output Scale Factor1 Output Voltage Range1 Data Sheet Min Typ 3.5 1 10 40 1 −10 2 Max Unit Test Conditions/Comments 6 µs V/µs nV-s mV 1 V change to 1 LSB. MΩ µA V Typically 100 MΩ. Per input; typically ±30 nA. +10 5 −7 Measured directly at comparator; does not include measure block errors. Uncalibrated. With respect to the measured voltage. +7 mV +12 µs mV Uncalibrated. −1.5 1 +1.5 µs % Of programmed current range, uncalibrated. −12.81 +12.81 V −6.405 0 +6.405 5.125 V V 0 2.56 115 +100 V Ω nA pF mA 0.25 −12 0.25 −100 5 −10 +10 −200 600 50 −1 +50 −1 −30 +200 900 mV mV μs +1 +70 V μA +1 μA +10 mV μs AVDD − 2.25 25 +10 +20 100 V V mV mA nF Ω μs 50 AVSS + 2.25 −10 −20 100 200 −10 +10 1.54 4.7 1 2 Rev. D | Page 10 of 68 % V mV/°C V MEASOUT gain = 1, VREF = 5 V, offset DAC = 0x8000. MEASOUT gain = 1, VREF = 2.5 V. MEASOUT gain = 0.2, VREF = 5 V, offset DAC = 0x8000. MEASOUT gain = 0.2, VREF = 2.5 V. When HW_INH is low. Pull-up for purpose of detecting open circuit on DUTGND, can be disabled. When pull-up disabled, DGS DAC = 0x3333 (1 V with VREF = 5 V). If DUTGND voltage is far away from one of comparator thresholds, more leakage may be present. If it moves 100 mV away from input level. Relative to a temperature change. Data Sheet Parameter SPI INTERFACE LOGIC Logic Inputs Input High Voltage, VIH AD5560 Min Typ Max 1.7/2.0 Input Low Voltage, VIL Unit Test Conditions/Comments V (2.3 V to 2.7 V)/(2.7 V to 5.5 V) JEDEC-compliant input levels. (2.3 V to 2.7 V)/(2.7 V to 5.5 V) JEDEC-compliant input levels. 0.7/0.8 V +1 10 µA pF 0.4 +1 10 V V μA pF 0.4 10 V pF 4 28 V HCAVSS1x HCAVDD2x −25 4 −5 28 V V HCAVSS2x AVDD AVSS DVCC AIDD 4 AISS4 DICC AIDD4 −25 8 −25 2.3 −5 28 −5 5.5 30 V V V V mA mA mA mA AISS4 −27 Input Current, IINH, IINL Input Capacitance, CIN1 CMOS Logic Outputs Output High Voltage, VOH Output Low Voltage, VOL Tristate Leakage Current Output Capacitance1 Open-Drain Logic Outputs Output Low Voltage, VOL Output Capacitance1 POWER SUPPLIES HCAVDD1x HCAIDD1 HCAIDD1 HCAISS1 HCAISS1 HCAIDD2 HCAIDD2 HCAISS2 HCAISS2 POWER-DOWN CURRENTS HCAIDD HCAISS HCAIDD HCAISS AIDD AISS DICC Maximum Power Dissipation EXTFORCE1 EXTFORCE2 Power-Up Overshoot1 −1 SDO, CPOL, CPOH, GPO, CPO. DVCC − 0.4 −1 10 10 −30 3 27 mA 20 0.5 −20 −0.5 15 0.25 −15 −0.25 250 mA mA mA mA mA mA mA mA 3 μA μA μA μA mA mA mA 10 5 5 W W % −250 250 −250 5 −5 Rev. D | Page 11 of 68 IOL = 500 µA. SDO, CPOL, CPOH, CPO. SDO, CPOL, CPOH, CPO. BUSY, TMPALM, CLALM, KELALM. IOL = 500 µA, CL = 50 pF, RPULLUP = 1 kΩ. |HCAVDDx – HCAVSSx| < 33 V, HCAVSSx ≥ AVSS, HCAVDDx ≤ AVDD. |HCAVDDx – HCAVSSx| < 33 V, HCAVSSx ≥ AVSS, HCAVDDx ≤ AVDD. |AVDD – AVSS| < 33 V. All ranges. All ranges. Channel inhibited/tristate, HW_INH or SW-INH low. Channel inhibited/tristate, HW_INH or SW-INH low. HCAVDDx and HCAVSSx supply currents shown are excluding load currents; however, for power budget calculations, the supply currents here are consumed by the load. When enabled, excluding load conditions. When disabled. When enabled, excluding load condition. When disabled. When enabled, excluding load conditions. When disabled. When enabled, excluding load conditions. When disabled. Supply currents on power-up or during a power-down condition. Of programmed value. AD5560 Parameter Power Supply Sensitivity1 ΔForced Voltage/ΔAVDD ΔForced Voltage/ΔAVSS ΔForced Voltage/ΔHCAVDDx ΔForced Voltage/ΔHCAVSSx ΔMeasured Current/ΔAVDD ΔMeasured Current/ΔAVSS ΔMeasured Current/ΔHCAVDDx ΔMeasured Current/ΔHCAVSSx ΔMeasured Voltage/ΔAVDD ΔMeasured Voltage/ΔAVSS ΔMeasured Voltage/ΔHCAVDDx ΔMeasured Voltage/ΔHCAVSSx ΔForced Voltage/ΔDVCC ΔMeasured Current/ΔDVCC ΔMeasured Voltage/ΔDVCC Data Sheet Min Typ Max −65 −65 −90 −90 −50 −43 −90 −90 −65 −65 −90 −90 −80 −80 −80 Unit dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB Guaranteed by design and characterization, not subject to production test. Programmable clamps must be enabled if taking advantage of reduced headroom/footroom. 3 Clamps disabled. 4 Not including internal pull-up current between AVDD/AVSS and HCAVDDx/HCAVSSx pins. 1 2 Rev. D | Page 12 of 68 Test Conditions/Comments DC to 1 kHz. −30 dB at 100 kHz. −25 dB at 100 kHz. −60 dB at 100 kHz. −62 dB at 100 kHz. −25 dB at 100 kHz. −20 dB at 100 kHz. −60 dB at 100 kHz. −60 dB at 100 kHz. −30 dB at 100 kHz. −25 dB at 100 kHz. −60 dB at 100 kHz. −65 dB at 100 kHz. −46 dB at 100 kHz. −36 dB at 100 kHz. −46 dB at 100 kHz. Data Sheet AD5560 TIMING CHARACTERISTICS HCAVDDx ≤ AVSS + 33 V, HCAVSSx ≥ AVSS, AVDD ≥ 8 V, AVSS ≤ −5 V, |AVDD − AVSS| ≥ 16 V and ≤ 33 V, VREF = 5 V (TJ = 25°C to 90°C, maximum specifications, unless otherwise noted). Table 2. SPI Interface Parameter 1, 2, 3 tUPDATE t1 t2 t3 t4 t5 t6 t7 t8 t9 4 t10 t11 t12 t13 t14 5, 6 t15 LOAD TIMING t16 t17 t18 t19 DVCC = 2.3 V to 2.7 V 600 25 10 10 10 15 5 5 4.5 40 1.5 280 25 400 250 45 30 DVCC = 2.7 V to 3.3 V 600 20 8 8 10 15 5 5 4.5 35 1.5 280 20 400 250 35 30 DVCC = 4.5 V to 5.5 V 600 20 8 8 10 15 5 5 4.5 30 1.5 280 10 400 250 25 30 Unit ns max ns min ns min ns min ns min ns min ns min ns min ns min ns max μs max ns max ns min µs max ns min ns max ns max Description Channel update cycle time SCLK cycle time; 60/40 duty cycle SCLK high time SCLK low time SYNC falling edge to SCLK falling edge setup time Minimum SYNC high time 24th SCLK falling edge to SYNC rising edge Data setup time Data hold time SYNC rising edge to BUSY falling edge BUSY pulse width low for DAC x1 write BUSY pulse width low for other register write RESET pulse width low RESET time indicated by BUSY low Minimum SYNC high time in readback mode SCLK rising edge to SDO valid SYNC rising edge to SDO high-Z 20 150 0 150 150 20 150 0 150 150 20 150 0 150 150 ns min ns min ns min ns min ns min LOAD pulse width low BUSY rising edge to force output response time BUSY rising edge to LOAD falling edge LOAD rising edge to FORCE output response time LOAD rising edge to current range response 1 Guaranteed by design and characterization, not production tested. All input signals are specified with tR = tF = 2 ns (10% to 90% of DVCC) and timed from a voltage level of 1.2 V. 3 See Figure 4 and Figure 5. 4 This is measured with the load circuit shown in Figure 2. 5 This is measured with the load circuit shown in Figure 3. 6 Longer SCLK cycle time is required for correct operation of readback mode; consult timing diagrams and timing specifications. 2 TIMING DIAGRAMS 200µA RLOAD 2.2kΩ CLOAD 50pF VOL TO OUTPUT PIN CLOAD 50pF 07779-002 TO OUTPUT PIN IOL VOH (MIN) – VOL (MAX) 2 200µA Figure 2. Load Circuit for Open Drain IOL Figure 3. Load Circuit for CMOS Rev. D | Page 13 of 68 07779-003 DVCC AD5560 Data Sheet t1 SCLK 1 24 2 t2 t3 t4 t6 SYNC t5 t7 t8 DB0 DB23 SDI t9 t10 BUSY t16 LOAD1,3 FORCE EXTFORCE1 EXTFORCE21 t17 t18 t16 LOAD2,3 FORCE EXTFORCE1 EXTFORCE22,3 t19 t11 RESET t12 1LOAD ACTIVE DURING BUSY. 2LOAD ACTIVE AFTER BUSY. 3LOAD FUNCTION IS AVAILABLE 07779-004 BUSY VIA CLEN OR HW_INH AS DETERMINED BY DPS REGISTER 2. Figure 4. SPI Write Timing SCLK 48 24 t14 t13 SYNC t15 DB23 D0B DB23 INPUT WORD SPECIFIES REGISTER TO BE READ SDO DB0 NOP CONDITION DB23 DB0 SELECTED REGISTER DATA CLOCKED OUT Figure 5. SPI Read Timing Rev. D | Page 14 of 68 07779-005 SDI Data Sheet AD5560 ABSOLUTE MAXIMUM RATINGS Table 3. Parameter AVDD to AVSS AVDD to AGND AVSS to AGND HCAVDDx to HCAVSSx HCAVDDx to AGND HCAVSSx to AGND HCAVDDx to AVSS HCAVDDx to AVDD HCAVSSx to AVSS DVCC to DGND AGND to DGND REFGND to AGND Digital Inputs to DGND Analog Inputs to AGND EXTFORCE1 and EXTFORCE2 to AGND1 Storage Temperature Operating Junction Temperature Reflow Profile Junction Temperature Power Dissipation ESD HBM FICDM 1 Rating 34 V −0.3 V to +34 V −34 V to +0.3 V 34 V −0.3 V to +34 V −34 V to +0.3 V −0.3 V to AVSS + 34 V −0.3 V to AVDD + 0.3 V +0.3 V to AVSS − 0.3 V −0.3 V to +7 V −0.3 V to +0.3 V −0.3 V to +0.3 V −0.3 V to DVCC + 0.3 V AVSS − 0.3 V to AVDD + 0.3 V AVDD − 28 V −65°C to +125°C 25°C to 90°C J-STD 20 (JEDEC) 150°C max 10 W max (EXTFORCE1 stage) 5 W max (EXTFORCE2 stage) Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. ESD CAUTION 1500 V 500 V When an EXTFORCE1 or EXTFORCE2 stage is enabled and the supply differential |AVDD − AVSS| > 28 V, take care to ensure that these pins are not directly shorted to AVSS voltage at any time because this can cause damage to the device. Rev. D | Page 15 of 68 AD5560 Data Sheet EXTFORCE1A HCAV DD1A HCAV SS2A HCAV SS1A EXTFORCE2A HCAV DD2A HCAV DD1B EXTFORCE1B HCAV SS2B HCAV SS1B EXTFORCE2B HCAV DD2B HCAV DD1C EXTFORCE1C HC_V SS1C GPO PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 EXTMEASIH2 47 EXTMEASIH1 TMPALM 3 46 AVDD CPOH/CPO 4 45 AVSS CPOL 5 44 AGND BUSY 6 43 GUARD/SYS_DUTGND 42 EXTMEASIL 41 SENSE 40 DUTGND 39 CF0 SDI 11 38 CF1 SYNC 12 37 CF2 RCLK 13 36 CF3 RESET 14 35 CF4 CLEN/LOAD 15 34 NC HW_INH/LOAD 16 33 AVDD CLALM 1 PIN 1 KELALM 2 SDO 7 AD5560 DVCC 8 TOP VIEW (Not to Scale) DGND 9 EXPOSED PAD ON TOP SCLK 10 NOTES 1. NC = NO CONNECT. 2. EXPOSED PAD ON TOP OF PACKAGE. EXPOSED PAD IS INTERNALLY CONNECTED TO MOST NEGATIVE POINT, AVSS. 07779-006 FORCE SYS_FORCE AVSS SYS_SENSE MASTER_OUT SLAVE_IN CC2 CC1 CC0 CC3 MEASOUT AVDD AVSS AGND VREF REFGND 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Figure 6. TQFP_EP Pin Configuration Table 4. TQFP_EP Pin Function Descriptions Pin No. Mnemonic Description 1 CLALM 2 KELALM 3 TMPALM 4 5 6 7 CPOH/CPO CPOL BUSY SDO 8 9 10 11 12 13 DVCC DGND SCLK SDI SYNC RCLK 14 15 RESET CLEN/LOAD 16 HW_INH/LOAD 17 REFGND Clamp Alarm Output. Open-drain output, active low; this pin can be programmed to be either latched or unlatched. Kelvin Alarm Pin for SENSE and DUTGND, Open-Drain Active Low. This pin can be programmed to be either latched or unlatched. Temperature Alarm Flag. Open-drain output, active low; this pin can be programmed to be either latched or unlatched. Comparator High Output (CPOH) or Window Comparator Output (CPO). Comparator Low Output. Open-Drain Active Low Output. This pin indicates the status of the calibration engine for the DAC channels. Serial Data Output. This pin is used for reading back DAC and DPS register information for diagnostic purposes. Digital Supply Voltage. Digital Ground Reference Point. Clock Input, Active Falling Edge. Serial Data Input. Frame Sync, Active Low. Ramp Clock Logic Input. If the ramp function is used, a clock signal of 833 kHz maximum should be applied to this input to drive the ramp circuitry. Tie RCLK low if it is unused. Logic Input. This pin is used to reset all internal nodes on the device to their power-on reset value. Clamp Enable. This input allows the user to enable or disable the clamp circuitry. This pin can be configured as a LOAD function to allow synchronization of multiple devices. Either CLEN or HW_INH can be chosen as LOAD input (see the system control register, Address 0x1). Hardware Inhibit Input to Disable Force Amplifier. This pin can be configured as a LOAD function to allow synchronization of multiple devices. Either CLEN or HW_INH can be chosen as a LOAD input (see the system control register, Address 0x1). Accurate Ground Reference for Applied Voltage Reference. Rev. D | Page 16 of 68 Data Sheet Pin No. 18 19, 44 20, 30, 45 Mnemonic VREF AGND AVSS 21, 33, 46 AVDD 22 23 24 25 26 27 28 29 31 32 34 35 36 37 38 39 40 41 42 43 MEASOUT CC3 CC0 CC1 CC2 SLAVE_IN MASTER_OUT SYS_SENSE SYS_FORCE FORCE NC CF4 CF3 CF2 CF1 CF0 DUTGND SENSE EXTMEASIL GUARD/SYS_DUTGND 47 48 49, 55, 61 EXTMEASIH1 EXTMEASIH2 HCAVDD1A, HCAVDD1B, HCAVDD1C EXTFORCE1A, EXTFORCE1B, EXTFORCE1C HCAVSS1A, HCAVSS1B, HCAVSS1C HCAVSS2A, HCAVSS2B EXTFORCE2A, EXTFORCE2B HCAVDD2A, HCAVDD2B GPO EP AD5560 Description Reference Input for DAC Channels, Input Range 2 V to 5 V. Analog Ground. Negative Analog Supply Voltage. These pins supply DACs and other high voltage circuitry, such as measure blocks. Positive Analog Supply Voltage. These pins supply DACs and other high voltage circuitry, such as measure blocks. Multiplexed DUT voltage sense, DUT current sense, Kelvin sense, or temperature output; refer to AGND. Compensation Capacitor Input 3. Compensation Capacitor Input 0. Compensation Capacitor Input 1. Compensation Capacitor Input 2. Slave Input When Ganging Multiple DPS Devices. Master Output When Ganging Multiple DPS Devices. External Sense Signal Output. External Force Signal Input. Output Force Pin for Internal Current Ranges. No Connect. Feedforward Capacitor 4. Feedforward Capacitor 3. Feedforward Capacitor 2. Feedforward Capacitor 1. Feedforward Capacitor 0. Device Under Test Ground. Input Sense Line. Low Side Measure Current Line for External High Current Ranges. Guard Amplifier Output Pin or System Device Under Test Ground Pin. See the DPS Register 2 in Table 19 for addressing details. 50, 56, 62 51, 57, 63 52, 58 53, 59 54, 60 64 65 Input High Measure Line for External High Current Range 1. Input High Measure Line for External High Current Range 2. High Current Positive Analog Supply Voltage, for EXTFORCE1 Range. Output Force. This pin is used for high Current Range 1, up to a maximum of ±1.2 A. High Current Negative Analog Supply Voltage, for EXTFORCE1 Range. High Current Negative Analog Supply Voltage, for EXTFORCE2 Range. Output Force. This pin is used for high Current Range 2, up to a maximum of ±500 mA. High Current Positive Analog Supply Voltage, for EXTFORCE2 Range. Extra Logic Output Bit. Ideal for external functions such as switching out a decoupling capacitor at DUT. The exposed pad is internally connected to AVSS. Rev. D | Page 17 of 68 Data Sheet 9 8 7 6 5 4 3 2 1 A EXTFORCE1A EXTFORCE1A EXTFORCE2A EXTFORCE1B EXTFORCE1B EXTFORCE2B EXTFORCE1C EXTFORCE1C GPO B HCAV DD1A HCAV SS1A HCAV DD2A HCAV DD1B HCAV SS1B HCAV DD2B HCAV DD1C HCAV SS1C CLALM C HCAVDD1A HCAVSS1A HCAVSS2A HCAVDD1B HCAVSS1B HCAVSS2B HCAVDD1C HCAVSS1C KELALM D AVDD EXTMEASIH1 EXTMEASIH2 CPOL CPOH/CPO TMPALM E AVSS AGND GUARD/ SYS_DUTGND DVCC SDO BUSY F DUTGND EXTMEASIL SENSE SDI SCLK DGND G CF0 CF2 SYS_FORCE SYS_SENSE CC0 AVSS RESET RCLK SYNC H CF1 CF3 SLAVE_IN MASTER_OUT CC1 MEASOUT AVDD VREF CLEN/ LOAD J CF4 AVDD FORCE CC2 CC3 AVSS AGND REFGND HW_INH/ LOAD 3 × 3 ARRAY IS VOID OF BALLS 07779-062 AD5560 Figure 7. Flip-Chip BGA Pin Configuration, Bottom Side (BGA Balls Are Visible) Table 5. Flip-Chip BGA Pin Function Descriptions Pin No. A1 A2, A3 A4 A5, A6 A7 A8, A9 B1 Mnemonic GPO EXTFORCE1C EXTFORCE2B EXTFORCE1B EXTFORCE2A EXTFORCE1A CLALM B2, C2 B3, C3 B4 B5, C5 B6, C6 B7 B8, C8 B9, C9 C1 HCAVSS1C HCAVDD1C HCAVDD2B HCAVSS1B HCAVDD1B HCAVDD2A HCAVSS1A HCAVDD1A KELALM C4 C7 HCAVSS2B HCAVSS2A Description Extra Logic Output Bit. Ideal for external functions such as switching out a decoupling capacitor at DUT. Output Force. These pins are used for high Current Range 1, up to a maximum of ±1.2 A. Output Force. This pin is used for high Current Range 2, up to a maximum of ±500 mA. Output Force. These pins are used for high Current Range 1, up to a maximum of ±1.2 A. Output Force. This pin is used for high Current Range 2, up to a maximum of ±500 mA. Output Force. These pins are used for high Current Range 1, up to a maximum of ±1.2 A. Clamp Alarm Output. Open-drain output, active low; this pin can be programmed to be either latched or unlatched. High Current Negative Analog Supply Voltage for EXTFORCE1 Range. High Current Positive Analog Supply Voltage for EXTFORCE1 Range. High Current Positive Analog Supply Voltage for EXTFORCE2 Range. High Current Negative Analog Supply Voltage for EXTFORCE1 Range. High Current Positive Analog Supply Voltage for EXTFORCE1 Range. High Current Positive Analog Supply Voltage for EXTFORCE2 Range. High Current Negative Analog Supply Voltage for EXTFORCE1 Range. High Current Positive Analog Supply Voltage for EXTFORCE1 Range. Kelvin Alarm Pin for SENSE and DUTGND, Open-Drain Active Low. This pin can be programmed to be either latched or unlatched. High Current Negative Analog Supply Voltage for EXTFORCE2 Range. High Current Negative Analog Supply Voltage for EXTFORCE2 Range. Rev. D | Page 18 of 68 Data Sheet Pin No. D1 Mnemonic TMPALM D2 D3 D7 D8 D9,H3, J8 CPOH/CPO CPOL EXTMEASIH2 EXTMEASIH1 AVDD E1 E2 BUSY SDO E3 E7 DVCC GUARD/SYS_DUTGND E8 E9, G4, J4 AGND AVSS F1 F2 F3 F7 F8 F9 G1 G2 DGND SCLK SDI SENSE EXTMEASIL DUTGND SYNC RCLK G3 G5 G6 G7 G8 G9 H1 RESET CC0 SYS_SENSE SYS_FORCE CF2 CF0 CLEN/LOAD H2 H4 H5 H6 H7 H8 H9 J1 VREF MEASOUT CC1 MASTER_OUT SLAVE_IN CF3 CF1 HW_INH/LOAD J2 J3 J5 J6 J7 J9 REFGND AGND CC3 CC2 FORCE CF4 AD5560 Description Temperature Alarm Flag. Open-drain output, active low; this pin can be programmed to be either latched or unlatched. Comparator High Output (CPOH) or Window Comparator Output (CPO). Comparator Low Output. Input High Measure Line for External High Current Range 2. Input High Measure Line for External High Current Range 1. Positive Analog Supply Voltage. These pins supply DACs and other high voltage circuitry, such as measure blocks. Open-Drain Active Low Output. This pin indicates the status of the calibration engine for the DAC channels. Serial Data Output. This pin is used for reading back DAC and DPS register information for diagnostic purposes. Digital Supply Voltage. Guard Amplifier Output Pin or System Device Under Test Ground Pin. See the DPS Register 2 in Table 19 for addressing details. Analog Ground. Negative Analog Supply Voltage. These pins supply DACs and other high voltage circuitry, such as measure blocks. Digital Ground Reference Point. Clock Input, Active Falling Edge. Serial Data Input. Input Sense Line. Low Side Measure Current Line for External High Current Ranges. Device Under Test Ground. Frame Sync, Active Low. Ramp Clock Logic Input. If the ramp function is used, a clock signal of 833 kHz maximum should be applied to this input to drive the ramp circuitry. Tie RCLK low if it is unused. Logic Input. This pin is used to reset all internal nodes on the device to their power-on reset value. Compensation Capacitor Input 0. External Sense Signal Output. External Force Signal Input. Feedforward Capacitor 2. Feedforward Capacitor 0. Clamp Enable. This input allows the user to enable or disable the clamp circuitry. This pin can be configured as a LOAD function to allow synchronization of multiple devices. Either CLEN or HW_INH can be chosen as LOAD input (see the system control register, Address 0x1). Reference Input for DAC Channels, Input Range is 2 V to 5 V. Multiplexed DUT voltage sense, DUT current sense, Kelvin sense, or temperature output; refer to AGND. Compensation Capacitor Input 1. Master Output When Ganging Multiple DPS Devices. Slave Input When Ganging Multiple DPS Devices. Feedforward Capacitor 3. Feedforward Capacitor 1. Hardware Inhibit Input to Disable Force Amplifier. This pin can be configured as a LOAD function to allow synchronization of multiple devices. Either CLEN or HW_INH can be chosen as a LOAD input (see the system control register, Address 0x1). Accurate Ground Reference for Applied Voltage Reference. Analog Ground. Compensation Capacitor Input 3. Compensation Capacitor Input 2. Output Force Pin for Internal Current Ranges. Feedforward Capacitor 4. Rev. D | Page 19 of 68 AD5560 Data Sheet TYPICAL PERFORMANCE CHARACTERISTICS 1.2 12 1.0 10 8 MV LINEARITY (mV) 0.6 0.4 0.2 6 MEASOUT GAIN = 0.2 4 2 0 MEASOUT GAIN = 1 –2 0 10,000 20,000 30,000 40,000 50,000 60,000 CODE –4 07779-026 –0.2 0 10,000 20,000 30,000 40,000 Figure 8. Force Voltage Linearity vs. Code, VREF = 5 V, No Load 60,000 Figure 11. Measure Voltage Linearity vs. Code (MEASOUT Gain 1, MEASOUT Gain = 0.2, Negative Skew Supply) 2.0 0.0100 TJ = 25°C AVDD = 16.25V AVSS = –16.25V VREF = 5V 1.5 HIGH: AVDD = 28V, AVSS = –5V, OFFSET DAC = 0xD1D LOW: AVDD = 5V, AVSS = –25V OFFSET DAC = 0xD4EB NOM: AVDD/AVSS = ±16.25V, OFFSET DAC = 0x8000 VREF = 5V 0.0075 1.0 0.5 LINEARITY (%) 0.0050 MEASOUT GAIN = 0.2 0 –0.5 –1.0 0.0025 0 LOW SUPPLIES –0.0025 –0.0050 –1.5 NOMINAL SUPPLIES –0.0075 MEASOUT GAIN = 1 0 10,000 20,000 30,000 40,000 50,000 60,000 CODE 07779-027 HIGH SUPPLIES –2.0 –0.0100 0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 CODE Figure 9. Measure Voltage Linearity vs. Code (MEASOUT Gain = 1, MEASOUT Gain = 0.2, Nominal Supplies) Figure 12. Measure Current Linearity vs. Code (MEASOUT Gain = 1, MI Gain = 20), TJ = 25°C 0.010 5 TJ = 25°C AVDD = 28V AVSS = –5V VREF = 5V OFFSET DAC = 0xD1D 4 HIGH: AVDD = 28V, AVSS = –5V, OFFSET DAC = 0xD1D LOW: AVDD = 5V, AVSS = –25V OFFSET DAC = 0xD4EB NOM: AVDD/AVSS = ±16.25V, OFFSET DAC = 0x8000 VREF = 5V 0.005 3 MI LINEARITY (%) MV LINEARITY (mV) 50,000 CODE 07779-034 0 07779-035 LINEARITY (mV) 0.8 MV LINEARITY ERROR (mV) TJ = 25°C AVDD = 8V AVSS = –25V VREF = 5V OFFSET DAC = 0xD4EB MEASOUT GAIN = 0.2 2 1 0 LOW SUPPLIES 0 –0.005 MEASOUT GAIN = 1 –1 NOMINAL SUPPLIES 10,000 20,000 30,000 CODE 40,000 50,000 60,000 –0.010 Figure 10. Measure Voltage Linearity vs. Code (MEASOUT Gain = 1, MEASOUT Gain = 0.2, Positive Skew Supply) 0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 CODE Figure 13. Measure Current Linearity vs. Code (MEASOUT Gain = 1, MI Gain = 10) Rev. D | Page 20 of 68 07779-036 0 07779-033 HIGH SUPPLIES –2 Data Sheet 0.0500 HIGH: AVDD = 28V, AVSS = –5V, OFFSET DAC = 0xD1D LOW: AVDD = 5V, AVSS = –25V OFFSET DAC = 0xD4EB NOM: AVDD/AVSS = ±16.25V, OFFSET DAC = 0x8000 VREF = 5V ±25mA RANGE 0.0375 AVDD = +16.25V AVSS = –16.25V 0.0375 V REF = 5V OFFSET DAC = 0x8000 0.0250 MI GAIN = 20 MEASOUT GAIN = 0.2 NOMINAL SUPPLIES 0.0125 LINEARITY (%) LOW SUPPLIES 0 –0.0125 –0.0375 0 –0.0125 10,000 20,000 30,000 40,000 50,000 60,000 70,000 CODE Figure 14. Measure Current Linearity vs. Code (MEASOUT Gain = 0.2, MI Gain = 20) 0.100 –0.0500 07779-037 0 0 10,000 20,000 30,000 40,000 50,000 60,000 CODE Figure 17. Measure Current Linearity vs. IRANGE (MEASOUT Gain = 0.2, MI Gain = 20) 1.5 HIGH: AVDD = 28V, AVSS = –5V, OFFSET DAC = 0xD1D LOW : AVDD = 5V, AVSS = –25V OFFSET DAC = 0xD4EB NOM : AVDD/AVSS = ±16.25V, OFFSET DAC = 0x8000 VREF = 5V ±25mA RANGE 0.075 2.5mA 25mA RANGE –0.0375 HIGH SUPPLIES –0.0500 TJ = 25°C 1.0 0.5 HIGH SUPPLIES 0.025 0 –0.025 NOMINAL SUPPLIES –0.050 LOW SUPPLIES 0 EXTFORCE1A EXTFORCE2B FORCE EXTFORCE1B EXTMEASIH1 SENSE EXTFORCE1C EXTMEASIH2 SYS_FORCE EXTFORCE2A EXTMEASIL SYS_SENSE COMBINED LEAKAGE –0.5 –1.0 –1.5 –2.0 –0.075 –2.5 0 10,000 20,000 30,000 40,000 50,000 60,000 –3.0 –10 07779-038 –0.100 70,000 CODE 5 0 5 10 STRESS VOLTAGE (V) 07779-030 LEAKAGE CURRENT (nA) 0.050 LINEARITY (%) 0.0125 –0.0250 –0.0250 Figure 18. Leakage Current vs. Stress Voltage (Force and Combined Leakage) Figure 15. Measure Current Linearity vs. Code (MEASOUT Gain = 0.2, MI Gain = 10) 7 0.0100 AVDD = +16.25V AVSS = –16.25V 0.0075 V REF = 5V OFFSET DAC = 0x8000 0.0050 MI GAIN = 20 MEASOUT GAIN = 1 VSTRESS = 9V 6 LEAKAGE CURRENT (nA) 25µA RANGE 0.0025 0 –0.0025 2.5mA –0.0050 –0.0075 –0.0100 0 10,000 20,000 5 4 3 2 1 25mA RANGE 30,000 40,000 50,000 60,000 CODE Figure 16. Measure Current Linearity vs. IRANGE (MEASOUT Gain = 1, MI Gain = 20) 0 25 07779-039 LINEARITY (%) 25µA RANGE EXTFORCE1A EXTFORCE2B FORCE EXTFORCE1B EXTMEASIH1 SENSE EXTFORCE1C EXTMEASIH2 SYS_FORCE EXTFORCE2A EXTMEASIL SYS_SENSE COMBINED LEAKAGE 35 45 55 65 TEMPERATURE (°C) 75 85 95 07779-031 LINEARITY (%) 0.0250 07779-040 0.0500 AD5560 Figure 19. Leakage Current vs. Temperature (Force and Combined Leakage), VSTRESS = 9 V Rev. D | Page 21 of 68 AD5560 Data Sheet 0 0.15 EXTFORCE1A EXTFORCE2B EXTFORCE1B EXTMEASIH1 SENSE EXTFORCE1C EXTMEASIH2 SYS_FORCE EXTFORCE2A EXTMEASIL SYS_SENSE 0.05 0 TJ = 25°C –0.02 –0.04 GAIN ERROR (%) LEAKAGE CURRENT (nA) 0.10 –0.05 HIGH NOMINAL –0.06 LOW –0.08 –0.10 –0.10 –0.15 5 10 STRESS VOLTAGE (V) 25 35 45 55 0 AV DD = ±16.25V AV SS = –16.25V VREF = 5V OFFSET DAC = 0x8000 VSTRESS = 9V 1.6 0.6 EXTFORCE1A EXTFORCE2B EXTFORCE1B EXTMEASIH1 SENSE EXTFORCE1C EXTMEASIH2 SYS_FORCE EXTFORCE2A EXTMEASIL SYS_SENSE 1.2 –1.0 1.0 0.8 –1.5 0.6 0.4 0.1 –2.0 0.2 35 45 55 65 75 85 95 TEMPERATURE (°C) –2.5 0 25 07779-061 0 25 –0.5 35 45 55 65 75 07779-043 0.2 1.4 POSITIVE GAIN ERROR (mV) LEAKAGE CURRENT (nA) 0.7 0.3 85 1.8 0.8 0.4 75 Figure 23. MI Positive Gain Error vs. Temperature, MI Gain = 20, MEASOUT Gain = 1 Figure 20. Leakage Current vs. Stress Voltage 0.5 65 TEMPERATURE (°C) NEGATIVE GAIN ERROR (mV) 0 07779-032 5 07779-48 –0.12 –0.20 –10 85 TEMPERATURE (°C) Figure 21. Leakage Current vs. Temperature, VSTRESS = 9 V Figure 24. FV Gain Error vs. Temperature 0.10 23.0 HIGH 0.2 LOW 0.05 22.5 OFFSET ERROR (mV) NOMINAL 0.2 HIGH –0.05 –0.10 LOW 0.2 HIGH: AVDD = 28V, AVSS = –5V, OFFSET DAC = 0xD1D LOW : AVDD = 5V, AVSS = –25V OFFSET DAC = 0xD4EB NOM : AVDD/AVSS = ±16.25V, OFFSET DAC = 0x8000 VREF = 5V LOW0.2/HIGH0.2/NOM0.2 MEAN FOR MEASOUT GAIN = 0.2 –0.15 –0.20 25 35 45 55 65 75 85 TEMPERATURE (°C) 22.0 21.5 21.0 20.5 Figure 22. MI Offset Error vs. Temperature, MI Gain = 20, MEASOUT Gain = 1 and 0.2 20.0 25 35 45 55 65 75 TEMPERATURE (°C) Figure 25. FV Offset Error vs. Temperature Rev. D | Page 22 of 68 85 07779-041 0 07779-047 OFFSET ERROR (%) NOMINAL Data Sheet AD5560 0 5 HIGH 4 –0.001 3 –0.003 LOW NOMINAL 2 OFFSET ERROR (mV) GAIN ERROR (%) –0.002 –0.004 –0.005 1 0 NOMINAL –1 –2 HIGH –3 LOW –0.006 35 45 55 65 75 85 TEMPERATURE (°C) –5 25 07779-045 –0.007 25 35 45 55 65 75 07779-044 –4 85 TEMPERATURE (°C) Figure 26. MV Gain Error vs. Temperature, MEASOUT Gain = 1 Figure 29. MV Offset Error vs. Temperature, MEASOUT Gain = 0.2 1.0 CH1 p-p 27mV CH1 AREA 10.92µVs 0.9 HIGH 0.8 OFFSET ERROR (mV) NOMINAL 0.7 LOW 0.6 FORCE 0.5 1 0.4 0.3 0.2 07779-015 SYNC 0.1 0 25 35 45 55 65 75 85 TEMPERATURE (°C) 07779-042 3 Figure 27. MV Offset Error vs. Temperature, MEASOUT Gain = 1 CH1 50mV CH3 5V B W B W M200µs T 10.4% A CH3 1.5V Figure 30. Range Change 2.5 mA to 25 mA, Safe Mode, 2.5 mA ILOAD, 10 μF Load 0.030 CH1 p-p 16mV CH1 AREA –5.336µVs NOMINAL LOW 0.020 HIGH FORCE 0.015 1 0.010 0.005 07779-016 SYNC 3 0 25 35 45 55 65 75 85 TEMPERATURE (°C) Figure 28. MV Gain Error vs. Temperature, MEASOUT Gain = 0.2 07779-046 GAIN ERROR (%) 0.025 CH1 50mV CH3 5V B W B W M200µs T 10.4% A CH3 1.5V Figure 31. Range Change 25 mA to 2.5 mA, Safe Mode, 2.5 mA ILOAD, 10 μF Load Rev. D | Page 23 of 68 AD5560 Data Sheet CH1 p-p 159mV CH1 AREA 14.31µVs CH1 p-p 84mV TRIGGER 2 FORCE FORCE 1 1 3 CH1 50mV CH3 5V M200µs T 10.4% B W B W A CH3 07779-020 07779-017 SYNC 1.5V CH1 100mV B W CH2 5V M40µs T 120.4µs A CH2 1.6V Figure 35. Autocompensation Mode 90% to 10% ILOAD Change, EXTFORCE2 Range, 10 µF Load Figure 32. Range Change 25 mA to EXTFORCE2, Safe Mode, 25 mA ILOAD, 10 μF Load CH1 p-p 36mV CH1 AREA –9.738µVs TRIGGER CH1 p-p 86mV 2 FORCE FORCE 1 07779-018 SYNC 3 CH1 50mV CH3 5V 07779-021 1 M200µs T 10.4% A CH3 CH1 100mV 1.5V B W CH2 5V M40µs T 120.4µs A CH2 4V Figure 36. Autocompensation Mode 10% to 90% ILOAD Change, EXTFORCE2 Range, 10 µF Load Figure 33. Range Change EXTFORCE2 to 25 mA, Safe Mode, 25 mA ILOAD, 10 µF Load 350 10µF LOAD 30µF LOAD 100µF LOAD PEAK-TO-PEAK (mV) 300 CH1 p-p 172mV TRIGGER 250 2 200 FORCE 1 150 100 07779-022 50 EXT RANGE 1 SAFE MODE AUTO COMP EXT RANGE 2 SAFE MODE AUTO COMP 25mA RANGE SAFE MODE AUTO COMP 07779-019 0 Figure 34. Kick/Droop Response vs. IRANGE, Compensation, and CLOAD,, 10% to 90% to 10% ILOAD Change Rev. D | Page 24 of 68 CH1 100mV B W CH2 5V M40µs T 120.4µs A CH2 1.6V Figure 37. Safe Mode 80% to 10%, EXTFORCE2 Range, 10 µF Load Data Sheet AD5560 CH1 p-p 174mV TRIGGER FORCE MEASOUT – MI 2 FORCE 1 2 07779-023 BUSY B CH1 100mV CH2 5V W M40µs T 120.4µs A CH2 07779-055 1 TA = 25°C AVDD = +16.25V AVSS = –16.25V VREF = 5V OFFSET DAC = 0x8000 IRANGE /ILOAD = 25mA 0 TO 10V STEP RLOAD = 40kΩ CLOAD = 220nF AUTOCOMP MODE 0x4480 MEASOUT GAIN 1, MI GAIN 20 4 3 4.6V CH1 5V CH3 5V Figure 38. Safe Mode 10% to 90%, EXTFORCE2 Range, 10 µF Load CH2 2V BW CH4 10V M20µs T 1.4% A CH3 2.9V Figure 41. Transient Response FVMI Mode, 25 mA Range, Autocompensation Mode 2.0 AVDD = +16.5V AVSS = –16.5V FORCE 1.9 MEASOUT VOLTAGE (V) MEASOUT – MI 1.8 1 1.6 2 1.5 BUSY 35 45 55 65 75 4 3 07779-024 1.4 25 85 FORCED TEMPERATURE (°C) TA = 25°C AVDD = +16.25V AVSS = –16.25V VREF = 5V OFFSET DAC = 0x8000 IRANGE /ILOAD = 250µA 0 TO 10V STEP RLOAD = 40kΩ CLOAD = 220nF SAFE MODE MEASOUT GAIN 1, MI GAIN 20 07779-056 1.7 CH1 5V CH3 5V CH2 2V BW CH4 10V M100µs T 7.2% A CH3 2.9V Figure 42. Transient Response FVMI Mode, 25mA Range, Safe Mode Figure 39. MEASOUT TSENSE Temperature Sensor vs. Temperature (Multiple Devices) FORCE MEASOUT – MI MEASOUT – MI 1 2 2 07779-054 BUSY 4 3 CH1 5V CH3 5V CH2 2V BW CH4 10V M400µs T 10.2% TA = 25°C AVDD = +16.25V AVSS = –16.25V VREF = 5V OFFSET DAC = 0x8000 IRANGE /ILOAD = EXTFORCE1/1.2A 0 TO 3.7V STEP CLOAD = 10µF CERAMIC AUTOCOMP MODE 0x9680 MEASOUT GAIN 1, MI GAIN 20 1 A CH3 BUSY 4 3 CH1 5V CH3 5V 2.9V CH2 1V BW CH4 10V M4µs T 3% A CH3 07779-057 FORCE TA = 25°C AVDD = +16.25V AVSS = –16.25V VREF = 5V OFFSET DAC = 0x8000 IRANGE /ILOAD = 250µA 0 TO 10V STEP RLOAD = 40kΩ CLOAD = 220nF AUTOCOMP MODE 0x4880 MEASOUT GAIN 1, MI GAIN 20 2.9V Figure 43. Transient Response FVMI Mode, EXTFORCE1 Range, Autocompensation Mode Figure 40. Transient Response FVMI Mode, ±250 µA Range, Autocompensation Mode Rev. D | Page 25 of 68 AD5560 Data Sheet 1000 PART H1 PART H2 PART H3 900 800 700 NSD (nV/√Hz) MEASOUT – MI TA = 25°C AVDD = +16.25V AVSS = –16.25V VREF = 5V OFFSET DAC = 0x8000 IRANGE /ILOAD = EXTFORCE1/1.2A 0 TO 3.7V STEP CLOAD = 10µF CERAMIC SAFE MODE MEASOUT GAIN 1, MI GAIN 20 200 FORCE 100 Figure 44. Transient Response FVMI Mode, EXTFORCE1 Range, Safe Mode 07779-025 GAIN = 11 GAIN = 10 FVMI GAIN = 01 2.9V FNMV GAIN = 00 A CH3 FVMV GAIN = 10 M20µs T 4.6% FVMN GAIN = 00 CH2 1V BW CH4 10V 0 GAIN = 10 BUSY 4 3 CH1 5V CH3 5V 400 GAIN = 00 2 500 300 07779-058 1 600 Figure 47. NSD vs. Amplifier Stage and Gain Setting at 1 kHz 20 DVCC = +5.25V, AVDD = +16.5V, AVSS = –16.5V 0 4 3 CH1 5V CH3 5V CH2 2V BW CH4 10V M10µs T 9.8% A CH3 –40 FOH MV: GAIN 0 MV: GAIN 1 MV: GAIN 2 MV: GAIN 3 MI: GAIN 0 MI:GAIN 1 MI: GAIN 2 MI: GAIN 3 –60 –80 –100 10 2.9V 100 1k 10k 100k 1M 10M FREQUENCY (Hz) Figure 45. Transient Response FVMI Mode, EXTFORCE2 Range, Autocompensation Mode 07779-049 2 ACPSRR (dB) 1 –20 07779-059 TA = 25°C AVDD = +16.25V MEASOUT – MI AVSS = –16.25V VREF = 5V OFFSET DAC = 0x8000 IRANGE /ILOAD = EXTFORCE2/ 300mA FORCE 0 TO 10V STEP CLOAD = 220nF AUTOCOMP MODE 0x4880 MEASOUT GAIN 1, MI GAIN 20 BUSY Figure 48. ACPSRR of AVDD vs. Frequency 0 FORCE –20 MEASOUT – MI BUSY 4 3 CH1 5V CH3 5V CH2 2V BW CH4 10V M100µs T 9.8% A CH3 ACPSRR (dB) –60 FOH MV: GAIN 0 MV: GAIN 1 MV: GAIN 2 MV: GAIN 3 MI: GAIN 0 MI:GAIN 1 MI: GAIN 2 MI: GAIN 3 –80 –100 –120 DVCC = +5.25V, AVDD = +16.5V, AVSS = –16.5V –140 10 2.9V 100 1k 10k 100k 1M FREQUENCY (Hz) Figure 46. Transient Response FVMI Mode, EXTFORCE2 Range, Safe Mode Rev. D | Page 26 of 68 Figure 49. ACPSRR of AVSS vs. Frequency 10M 07779-050 2 TA = 25°C AVDD = +16.25V AVSS = –16.25V VREF = 5V OFFSET DAC = 0x8000 IRANGE /ILOAD = EXTFORCE2/300mA 0 TO 10V STEP CLOAD = 220nF SAFE MODE MEASOUT GAIN 1, MI GAIN 20 07779-060 1 –40 Data Sheet AD5560 0 0 MI: GAIN 0 –20 –20 FOH MI: GAIN 0 –40 ACPSRR (dB) ACPSRR (dB) –40 –60 MV: GAIN 0 –60 MV: GAIN 0 –80 –80 –100 –100 –120 100 1k 10k 100k 1M 10M FREQUENCY (Hz) –140 10 1k 10k 100k 1M 10M FREQUENCY (Hz) Figure 50. ACPSRR of DVCC vs. Frequency Figure 52. ACPSRR of HCAVSSx vs. Frequency 1600 0 MI: GAIN 0 1400 –20 CABLE L = CABLE L = CABLE L = CABLE L = 2µH, CLAMP AT 1.2A 1µH, CLAMP AT 1.2A 0.2µH, CLAMP AT 1.2A 0µH, CLAMP AT 1.2A CABLE L = CABLE L = CABLE L = CABLE L = 2µH, CLAMP AT 800mA 1µH, CLAMP AT 800mA 0.2µH, CLAMP AT 800mA 0µH, CLAMP AT 800mA CABLE L = CABLE L = CABLE L = CABLE L = 2µH, CLAMP AT 400mA 1µH, CLAMP AT 400mA 0.2µH, CLAMP AT 400mA 0µH, CLAMP AT 400mA CABLE L = CABLE L = CABLE L = CABLE L = 2µH, CLAMP AT 100mA 1µH, CLAMP AT 100mA 0.2µH, CLAMP AT 100mA 0µH, CLAMP AT 100mA 1200 ICLAMP VALUE (mA) –40 MV: GAIN 0 –60 –80 –100 1000 800 600 400 FOH –120 200 –140 10 100 1k 10k 100k 1M FREQUENCY (Hz) 10M Figure 51. ACPSRR of HCAVDDx vs. Frequency 0 0.001 0.01 0.1 1 RLOAD (Ω) Figure 53. ICLAMP Value vs. RLOAD – Cal at 1Ohm Rev. D | Page 27 of 68 10 07779-063 DVCC = +5.25V, AVDD = +16.5V, AVSS = –16.5V 07779-052 ACPSRR (dB) 100 07779-053 10 07779-051 –120 FOH DVCC = +5.25V, AVDD = +16.5V, AVSS = –16.5V DVCC = +5.25V, AVDD = +16.5V, AVSS = –16.5V AD5560 Data Sheet TERMINOLOGY Offset Error Offset error is a measure of the difference between the actual voltage and the ideal voltage at midscale or at zero current expressed in millivolts (mV) or percentage of full-scale range (%FSR). Gain Error Gain error is the difference between full-scale error and zeroscale error. It is expressed in percentage of full-scale range (%FSR). Gain Error = Full-Scale Error − Zero-Scale Error where: Full-Scale Error is the difference between the actual voltage and the ideal voltage at full scale. Zero-Scale Error is the difference between the actual voltage and the ideal voltage at zero scale. Linearity Error Linearity error, or endpoint linearity, is a measure of the maximum deviation from a straight line passing through the endpoints of the full-scale range. It is measured after adjusting for offset error and gain error and is expressed in millivolts (mV). Common-Mode (CM) Error CM error is the error at the output of the amplifier due to the common-mode input voltage. It is expressed in percentage of full-scale voltage range per volt (%FSVR/V). Clamp Limit Clamp limit is a measure of where the clamps begin to function fully and limit the clamped voltage or current. Slew Rate The slew rate is the rate of change of the output voltage expressed in volts per microsecond (V/μs). Differential Nonlinearity (DNL) DNL is the difference between the measured change and the ideal 1 LSB change between any two adjacent codes. A specified DNL of ±1 LSB maximum ensures monotonicity. Output Voltage Settling Time Output voltage settling time is the amount of time it takes for the output of a DAC to settle to a specified level for a full-scale input change. Digital-to-Analog Glitch Energy Digital-to-analog glitch energy is the amount of energy that is injected into the analog output at the major code transition. It is specified as the area of the glitch in nanovolts per second (nV-sec). It is measured by toggling the DAC register data between 0x7FFF and 0x8000. AC Power Supply Rejection Ratio (ACPSRR) ACPSRR is a measure of the part’s ability to avoid coupling noise and spurious signals that appear on the supply voltage pin to the output of the switch. The dc voltage on the device is modulated by a sine wave of 0.2 V p-p. The ratio of the amplitude of the signal on the output to the amplitude of the modulation is the ACPSRR. It is expressed in decibels (dB). VSTRESS VSTRESS is the stress voltage applied to each pin during leakage testing. Leakage Current Leakage current is the current measured at an output pin when the circuit connected to that pin is in high impedance state. Rev. D | Page 28 of 68 Data Sheet AD5560 THEORY OF OPERATION The AD5560 is a single-channel, device power supply for use in semiconductor automatic test equipment. All the DAC levels required to operate the device are available on chip. This block performs three functions related to the force and sense lines. • This device contains programmable modes to force a pin voltage and measure the corresponding current (FVMI) covering a wide current measure range of up to ±1.2 A. A voltage sense amplifier allows measurement of the DUT voltage. Measured current or voltage is available on the MEASOUT pin. FORCE AMPLIFIER The force amplifier is a unity gain amplifier forcing voltage directly to the device under test (DUT). This high bandwidth amplifier allows suppression of load transient induced glitching on the amplifier output. Headroom and footroom requirements for the amplifier are 2.25 V and an additional ±500 mV dropped across the selected sense resistor with full-scale current flowing. • • It clamps the sense line to within a programmable threshold level (plus a VBE) of the force line, where the programmable threshold is set by the OSD DAC voltage level. This limits the maximum or minimum voltage that can appear on the FORCE pin; it can be driven no higher than [V(FIN DAC) + threshold + VBE] and no lower than [V(FIN DAC) − threshold − VBE]. It triggers an alarm on KELALM if the force line goes more than the threshold voltage away (OSD DAC level) from the sense line. It translates the V(force − sense) voltage to a level relative to AGND so that it can be measured through the MEASOUT pin. An extra control bit (GPO) is available to switch out DUT decoupling when making low current measurements. The open-sense detect level is programmable over the range 0.62 V to 5 V (16-bit OSD DAC plus one diode drop). The 5 V OSD DAC can be accessed through the serial interface (see the DAC register addressing portion of Table 24). There is a 10 kΩ resistor that can be connected between the FORCE and SENSE pins by use of SW11. This 10 kΩ resistor is intended to maintain a force/sense connection when a DUT is not in place. It is not intended to be connected when measurements are being made because this defeats the purpose of the OSD circuit in identifying an open circuit between FORCE and SENSE. In addition, the sense path has a 2.5 kΩ resistor in series; therefore, if the 10 kΩ switch is closed, errors may become apparent when in high current ranges. HW_INH Function DEVICE UNDER TEST GROUND (DUTGND) A hardware inhibit pin (HW_INH/LOAD) allows disabling of the force amplifier, making the output high impedance. This function is also available through the serial interface (see the SW-INH bit in the DPS Register 1, Address 0x2). DUTGND is the ground level of the DUT. The amplifier is designed to drive high currents up to ±1.2 A with the capability of ganging together outputs of multiple AD5560 devices for currents in excess of ±1.2 A. The force amplifier can be compensated to ensure stability when driving DUT capacitances of up to 160 μF. The device is capable of supplying transient currents in excess of ±1.2 A when powering a DUT with a large decoupling capacitor. A clamp enable pin (CLEN) allows disabling of the clamp circuitry to allow the amplifier to quickly charge this large capacitance. This pin can also be configured as a LOAD function to allow multiple devices to be synchronized. Note that either CLEN or HW_INH can be chosen as a LOAD function. DAC REFERENCE VOLTAGE (VREF) One analog reference input, VREF, supplies all DAC levels with the necessary reference voltage to generate the required dc levels. OPEN-SENSE DETECT (OSD) ALARM AND CLAMP The open-sense detect (OSD) circuitry protects the DUT from overvoltage when the force and sense lines of the force amplifier becoming disconnected from each other. DUTGND Kelvin Sense KELALM flags when the voltage at the DUTGND pin moves too far away from the AGND line (>1 V default setting of the DGS DAC). This alarm trigger is programmable via the serial interface. The threshold for the alarm function is programmable using the DUTGND SENSE DAC (DGS DAC) (see Table 24). The DUTGND pin has a 50 μA pull-up resistor that allows the alarm function to detect whether DUTGND is open. Setting the disable DUTALM bit high (Register 0x6, Bit 10) disables the 50 μA pull-up resistor and also disables the alarm feature. The alarm feature can also be set to latched or unlatched (Register 0x6, Bit 11). Kelvin Alarm (KELALM) The open-drain active low Kelvin alarm pin flags the user when an open occurs in either the sense or DUTGND line; it can be programmed to be either latched or unlatched (Register 0x6, Bit 13, Bit 11, Bit 7). The delay in the alarm flag is 50 μs. Rev. D | Page 29 of 68 AD5560 Data Sheet GPO The GPO pin can be used as an extra control bit for external switching functions, such as for switching out DUT decoupling when making low current measurements. The GPO pin is also internally connected to an array of thermal diodes scattered across the AD5560. The diagnostic register (Address 0x7) details the addressing and location of the diodes. These can be used for diagnostic purposes to determine the thermal gradients across the die and across a board containing many AD5560 devices. When selected, the anode of these diodes is connected to GPO and the cathode to AGND. The AD5560 evaluation board uses the ON Semiconductor® ADT7461 temperature sensor for the purpose of analyzing the temperature at different points across the die. COMPARATORS The DUT measured value is monitored by two comparators (CPOL, CPOH). These comparators give the advantage of speed for go-no-go testing. CPOL 1 0 1 The clamp register limits the CLL clamp to the range 0x0000 to 0x7FFF; any code in excess of this is seen as 0x7FFF. Similarly, the CLH clamp registers are limited to the range 0x8000 to 0xFFFF (see Table 24). Clamp Alarm Function (CLALM) The CLALM open-drain output flags the user when a clamp limit has been hit; it can be programmed to be either latched or unlatched. Pin 15 (CLEN) allows the user to disable the clamping function when powering a device with large DUT capacitance, thus allowing increased current drive to the device and, therefore, speeding up the charging time of the load capacitance. CLEN is active high. CPOH 0 1 This pin can also be configured as LOAD to allow multiple devices to be synchronized. Note that either CLEN or HW_INH can be chosen as a LOAD function. 1 To minimize the number of comparator output lines routed back to the controller, it is possible to change the comparator function to a window comparator that outputs on one single pin, CPO. This pin is shared with CPOH and, when configured through the serial interface, it provides information on whether the measured DUT current or voltage is inside or outside the window set by the CPL and CPH DAC levels (see Table 24). SHORT-CIRCUIT PROTECTION The AD5560 force amplifier stage has built-in short-circuit protection per stage as noted in the Specifications section. When the current clamps are disabled, the user must minimize the duration of time that the device is left in a short-circuit condition (for all current ranges). GUARD AMPLIFIER A guard amplifier allows the user to force the shield of the coaxial cable to be driven to the same forced voltage at the DUT, ensuring minimal voltage drops across the cable to minimize errors from cable insulation leakage. Table 7. Comparator Output Function in CPO Mode Test Condition (VDUT or IDUT) > CPL and < CPH (VDUT or IDUT) < CPL or > CPH The clamp levels should not be set to the same level; instead, they should be set a minimum of 2 V apart (irrespective of the MI gain setting). This equates to 10% of FSCR (MI gain = 20) (20% of FSCR, MI gain of 10) apart. They should also be 1 V away from the 0 A level. Clamp Enable Function (CLEN/LOAD) Table 6. Comparator Output Function Test Condition (VDUT or IDUT) > CPH (VDUT or IDUT) < CPH (VDUT or IDUT) > CPL (VDUT or IDUT) < CPL CPH > (VDUT or IDUT) > CPL If a clamp level is exceeded, this is flagged via the latched opendrain CLALM pin, and the resulting alarm information can be read back via the SPI interface. CPO Output 1 0 CURRENT CLAMPS High and low current clamps are included on chip. These protect the DUT in the event of a short circuit. The CLH and CLL levels are set by the 16-bit DAC levels. The clamp works to limit the current supplied by the force amplifier to within the set levels. The clamp circuitry compares the voltage across the sense resistor (multiplied by an in-amp gain of 10 or 20) to compare to the programmed clamp limit and activates the clamp circuit if either the high level or low level is exceeded, thus ensuring that the DUT current can never exceed the programmed clamp limit + 10% of full-scale current. The guard amplifier also has an alarm function that flags the open-drain KELALM pin when the guard output is shorted. The delay in the alarm flag is 200 μs. The guard amplifier output (GUARD/SYS_DUTGND, Pin 43) can also be configured to function as a SYS_DUTGND pin; to do this, the guard amplifier must be tristated via software (see DPS Register 2, Table 19). COMPENSATION CAPACITORS The force amplifier is capable of driving DUT capacitances up to 160 μF. Four external compensation capacitor (CCx) inputs are provided to ensure stability into the maximum load capacitance while ensuring that settling time is optimized. In addition, five CFx capacitor inputs are provided to switch across the sense Rev. D | Page 30 of 68 Data Sheet AD5560 resistors to further optimize stability and settling time performance. The AD5560 has three compensation modes: safe mode, autocompensation mode, and manual compensation mode, all of which are described in more detail in the Force Amplifier Stability section. HIGH CURRENT RANGES The range of suggested compensation capacitors allows optimum performance for any capacitive load from 0 pF to 160 μF using one of the modes previously listed. Master and Slaves in Force Voltage (FV) Mode Although there are four compensation input pins and five feedforward capacitor inputs pins, all capacitor inputs may be used only if the user intends to drive large variations of DUT load capacitances. If the DUT load capacitance is known and does not change for all combinations of voltage ranges and test conditions, then it is possible only one set of CCx and CFx capacitors may be required. Table 8. Suggested Compensation Capacitor Selection Value 100 pF 100 pF 330 pF 3.3 nF 4.7 nF 22 nF 100 nF 470 nF 2.2 μF All devices are placed in force voltage (FV) mode. One device acts as the master device and the other devices act as slaves. By connecting in this manner, any device can be configured as the master. Here, the MASTER_OUT pin of the master device is connected to the output of the force amplifier, and it feeds the inputs of each slave force amplifier (via the SLAVE_IN pin ). All devices are connected externally to the DUT. For current to be shared equally, there must be good matching between each of the paths to the DUT. Settings for DPS Register 2 are master = 0x0000, slave = 0x0400. Clamps should be disabled in the slave devices. MASTER DPS SLAVE IN SW5-a SW6 MASTER OUT SW16 SW5-b FIN DAC SW5-a LOCAL FEEDBACK ×20 OR ×W RSENSE SENSE ×1 SLAVE DPS 1 SLAVE IN SW5-a SW6 MASTER OUT SW16 SW5-b FIN DAC CURRENT RANGE SELECTION SW5-a LOCAL FEEDBACK ×20 OR ×W EXTFORCE2 EXTMEASIH1 EXTMEASIL ISENSE AMP VSENSE AMP EXTFORCE1 SENSE ×1 SLAVE DPS 2 SLAVE IN SW5-a SW6 MASTER OUT The measure current amplifier has two gain settings, 10 and 20. The two gain settings allow users to achieve the quoted/ specified current ranges with large or small voltage swings. The gain of 20 setting is intended for use with a 5 V reference, and the gain of 10 setting is for use with a 2.5 V reference. Both combinations ensure the specified current ranges. Other VREF/gain setting combinations should only be used to achieve smaller current ranges. Attempting to achieve greater current ranges than the specified ranges is outside the intended operation of the AD5560. The maximum guaranteed voltage across RSENSE is ±0.64 V (gain of 20) or ±0.7 V (gain of 10). SW16 SW5-b FIN DAC SW5-a LOCAL FEEDBACK ×20 OR ×W EXTFORCE1 EXTFORCE2 EXTMEASIH1 EXTMEASIL ISENSE AMP ×1 SENSE VSENSE AMP DUT DUTGND Figure 54. Simplified Block Diagram of High Current Ganging Mode Rev. D | Page 31 of 68 07779-007 Integrated thin film resistors minimize external components and allow easy selection of current ranges from ±5 µA to ±25 mA. Using external current sense resistors, two higher current ranges are possible: EXTFORCE1 can drive currents up to ±1.2 A, while EXTFORCE2 is designed to drive currents up to ±500 mA. The voltage drop across the selected sense resistor is ±500 mV when full-scale current is flowing through it. EXTMEASIH1 RSENSE The voltage range for the CCx and CFx pins is the same as the voltage range expected on FORCE; therefore, choice of capacitors should take this into account. CFx capacitors can have 10% tolerance; this extra variation directly affects settling times, especially when measuring current in the low current ranges. Selection of CCx should be at ≤5% tolerance. EXTFORCE2 EXTMEASIL ISENSE AMP VSENSE AMP EXTFORCE1 RSENSE Capacitor CC0 CC1 CC2 CC3 CF0 CF1 CF2 CF3 CF4 For currents in excess of 1200 mA, a gang mode is available whereby multiple devices are ganged together for higher currents. There are two methods of ganging channels together; these are discussed in the following two sections. AD5560 Data Sheet Master in FV Mode, Slaves in Force Current (FI) Mode The master device is placed into FV mode, and all slave devices into force current (FI) mode. The measured current of the master device (MASTER_OUT) is applied to the input of all slave devices (SLAVE_IN), and the slaves act as followers. All channels work to share the current equally among all devices in the gang. Because the slaves force current, matching the DUT paths is not so critical. Settings for DPS Register 2 are master = 0x0200, slave = 0x0600. Clamps should be disabled in the slave devices. MASTER DPS SLAVE IN SW5-a FIN DAC SW5-b SW5-a For example, ganging five 25 V/25 mA devices using the 25 mA range achieves a 25 V/625 mA range, whereas five 15 V/200 mA devices using the EXTFORCE2 path can achieve a 15 V/1 A range. Similarly, ganging four 3.5 V/1.2 A devices using the EXTFORCE1 path results in a 3.5 V/4.8 A DPS. IDEAL SEQUENCE FOR GANG MODE Use the following steps to bring devices into and out of gang mode: SW6 MASTER OUT SW16 The EXTFORCE1, EXTFORCE2, or ±25 mA ranges can be used for the gang mode. Therefore, it is possible to gang devices to get a high voltage/high current combination, or a low voltage/high current combination. 1. EXTFORCE1 2. EXTFORCE2 SENSE MEASOUT BUFFER AND GAIN 3. 4. EXTMEASIH1 ×20 RSENSE EXTMEASIL ISENSE AMP SLAVE DPS 1 5. SLAVE IN SW5-a To remove devices from the gang, the master device should be programmed to force 0 V out again. The procedure for removing devices should be the reverse of Step 1 through Step 5. SW6 MASTER OUT SW16 FIN DAC SW5-b SW5-a EXTFORCE1 Note that this may not always be possible in practice; therefore, it is also possible to gang and ungang while driving a load. Just ensure that the slave devices are in high-Z mode while configuring them into the required range and gang setting. EXTFORCE2 SENSE EXTMEASIH1 ×20 RSENSE MEASOUT BUFFER AND GAIN EXTMEASIL ISENSE AMP SLAVE DPS 2 Gang mode extends only to the ±25 mA range and the two high current ranges, EXTFORCE1 and EXTFORCE2. Therefore, where an accurate measurement is required at a low current, the user should remove slaves from the gang to move to the appropriate lower current range to make the measurement. Similarly, slaves can be brought back into the gang if needed. SLAVE IN SW5-a SW6 MASTER OUT SW16 FIN DAC SW5-b SW5-a EXTFORCE1 COMPENSATION FOR GANG MODE EXTFORCE2 SENSE ×20 ISENSE AMP EXTMEASIL When ganging, the slave devices should be set to the fastest response. DUT DUTGND Figure 55. Simplified Block Diagram of Gang Mode, Using an FV/FI Combination 07779-008 EXTMEASIH1 RSENSE MEASOUT BUFFER AND GAIN Choose the master device and force 0 V output, corresponding to zero current. Select slave DPS 1 and place it in slave mode (keep slaves in high-Z mode via SW-INH or HW_INH until ready to gang). Select to gang in either current or voltage mode. Repeat Step 2 and Step 3 one at a time through the chain of slaves. Load the required voltage to the master device. The other devices copy either voltage or current as programmed. When slaves are in FI mode, the AD5560 force amplifier overrides other compensation settings to enforce CFx = 0, RZ = 0, and gmx ≤ 1. This is done internally to the force amplifier; therefore, readback will not show that the signals inside the force amplifier actually change. SYSTEM FORCE/SENSE SWITCHES System force/sense switches allow easy connection of a central or system parametric measurement unit (PMU) for calibration or additional measurement purposes. The system device under test ground (SYS_DUTGND) switch is shared with the GUARD/SYS_DUTGND pin (Pin 43). See the DPS Register 2 in Table 19 for addressing details. Rev. D | Page 32 of 68 Data Sheet AD5560 DIE TEMPERATURE SENSOR AND THERMAL SHUTDOWN These diodes can be muxed out onto the GPO pin. The diagnostic register (Address 0x7) details the addressing and location of the diodes. These can be used for diagnostic purposes to determine the thermal gradients across the die and across a board containing many AD5560 devices. When selected, the anode of each diode is connected to GPO and the cathode to AGND. The AD5560 evaluation board uses the ON Semiconductor ADT7461 temperature sensor for the purpose of analyzing the temperature at different points across the die. There are three types of temperature sensors in the AD5560. • The first is a temperature sensor available on the MEASOUT pin and expressed in voltage terms. Nominally at 25°C, this sensor reads 1.54 V. It has a temperature coefficient of 4.7 mV/°C. This sensor is active during power-down mode. Die Temp = (VMEASOUT(TSENSE) − 1.54)/0.0047 + 25°C Based on typical temperature sensor output voltage at 25°C and output scaling factor. • The second type of temperature sensor is related to the thermal shutdown feature in the device. Here, there are sensors located in the middle of the enabled power stage, which are used to trip the thermal shutdown. The thermal shutdown feature senses only the power stages, and the power stage that it senses is determined by the active stage. If ranges of <25 mA are selected, the EXTFORCE1 sensor is monitored. The EXTFORCE1 power stage itself is made up of three identical stages, but the thermal shutdown is activated by only one stage (EXTFORCE1B). Similarly, the EXTFORCE2 stage is made up of two identical output stages, but the thermal shutdown can be activated by only one stage (EXTFORCE2A). The thermal shutdown circuit monitors these sensors and, in the event of the die temperature exceeding the programmable threshold temperature (100°C, 110°C, 120°C, 130°C (default)), the device protects itself by inhibiting the force amplifier stage, clearing SW-INH in DPS Register 1 and flagging the overtemperature event via the open-drain TMPALM pin, which can be programmed to be either latched or unlatched. These temperature sensors can be read via the MEASOUT pin by selecting them in the diagnostic register (Table 23, VPTAT low and VPTAT high). They are expressed in voltage and to scale to temperature. They must be referred to the VTSD reference voltage levels (see Table 23) also available on MEASOUT. This set of sensors is not active in power-down mode. Die Temp_y = {(VPTAT_x − VTSD_low)/[(VTSD_high − VTSD_low)/(Temp_high – Temp_low)]} + Temp_low where: x, y are (high, NPN) and (low, PNP). Temp_low = −273°C. Temp_high = +130°C. • The third set of temperature sensors is an array of thermal diodes scattered across the die. These diodes allow the user to evaluate the temperature of different parts of the die and are of great use to determine the temperature gradients across the die and the temperature of the accurate portions of the die when the device is dissipating high power. For further details on the thermal array and locations, see the diagnostic register section in Table 23. Note that, when a thermal shutdown occurs, as the force amplifier is inhibited or tristated, user intervention is required to reactivate the device. It is necessary to clear the temperature alarm flag by issuing a read command of Register Address 0x44 (alarm status and clear alarm status register, Table 25), and then issuing a new write to the DPS Register 1 (SW-INH = 1) to reenable the force amplifier. See also the Thermal Considerations section. MEASURE OUTPUT (MEASOUT) The measured DUT voltage, current (voltage representation of DUT current), KSENSE, or die temperature is available on MEASOUT with respect to AGND. The default MEASOUT range is the forced voltage range for voltage measure and current measure (nominally ±12.81 V, depending on reference voltage and offset DAC) and includes overrange to allow for system error correction. The serial interface allows the user to select another MEASOUT range of (1.025 × VREF) to AGND; this range is suitable for use with an ADC with a smaller input range. To allow for system error correction, there is additional gain for the force function. If this overrange is used as intended, the output range on MEASOUT scales accordingly. The MEASOUT line can be tristated via the serial interface. When using low supply voltages, ensure that there is sufficient headroom and footroom for the required force voltage range. VMID VOLTAGE The midcode voltage (VMID) is used in the measure current amplifier block to center the current ranges at about 0 A. This is required to ensure that the quoted current ranges can be achieved when using offset DAC settings other than the default. VMID corresponds to 0x8000 or the DAC midcode value, that is, the middle of the voltage range set by the offset DAC setting (see Table 15 and Figure 56). VMID = 5.125 × VREF × (32,768/216) − (5.125 × VREF × (OFFSET_DAC_CODE/216)) or Rev. D | Page 33 of 68 VMID = 5.125 × VREF × ((32,768 − Offset DAC)/216) AD5560 Data Sheet VMIN is another inportant voltage level that is used in other parts of the circuit. When using a MEASOUT gain of 0.2, the VMIN level is used to scale the voltage range; therefore, when choosing supply rails, it is very important to ensure that there is sufficient footroom so that the VMIN level is not impinged on (the high voltage DAC amplifiers used here require approximately 2 V footroom to AVSS). See the Choosing AVDD/AVSS Power Supply Rails section for more information. VMIN = −5.125 × VREF × (OFFSET_DAC_CODE/216) Table 9. MEASOUT Output Ranges Output Voltage Range 1 MEASOUT Function GAIN1 = 0, MEASOUT Gain = 1 Measure Voltage (MV) MI gain = 20 Measure GAIN0 = 0 Current MI gain = 10 GAIN0 = 1 (MI) 1 Transfer Function ±VDUT (IDUT × RSENSE × 20) + VMID (IDUT × RSENSE × 10) + VMID Offset DAC = 0x0 0 V to 25.62 V 0 V to 25.62 V 0 V to 12.81 V (VREF = 2.5 V) Offset DAC = 0x8000 ±12.81 V ±12.81 V ±6.4 V (VREF = 2.5 V) Offset DAC = 0xE000 −22.42 V to +3.2 V −22.42 V to +3.2 V −11.2 V to +1.6 V (VREF = 2.5 V) VREF = 5 V, unless otherwise noted. Table 10. MEASOUT Function GAIN1 = 1, MEASOUT Gain = 0.2 Measure Voltage (MV) Measure Current (MI) 1 2 Transfer Function MV = 0.2 × (VDUT − VMIN) GAIN0 = 0 MI gain = 20 (IDUT × RSENSE × 20 × 0.2) + 0.5125 × VREF GAIN0 = 1 MI gain = 10 (IDUT × RSENSE × 10 × 0.2) + 0.5125 × VREF Output Voltage Range 1, 2 0 V to 5.12 V (±2.56 V centered around 2.56 V) (includes overrange) 0 V to 5.12 V (±2.56 V centered around 2.56 V) (includes overrange) 1.28 V to 3.84 V (±1.28 V, centered around 2.56 V) 0 V to 2.56 V (±1.28 V, centered around 1.28 V) (VREF = 2.5 V) VREF = 5 V, unless otherwise noted. The offset DAC setting has no effect on the output voltage range. Table 11. Possible ADCs and ADC Drivers for Use with AD5560 1 Part No. AD7685 Resolution 16 Sample Rate 250 kSPS Channels 1 AIN Range 2 0 to VREF Interface Serial, SPI ADC Driver ADA4841-x Multiplexer 3 ADG704, ADG708 AD7686 16 500 kSPS 1 0 to VREF Serial, SPI ADA4841-x ADG704, ADG708 AD7693 16 500 kSPS 1 −VREF to +VREF Serial, SPI ADA4841-x, ADA4941-1 AD7610 16 250 kSPS 1 Serial, parallel AD8021 AD7655 16 1 MSPS 4 Bipolar 10 V, bipolar 5 V, unipolar 10 V, unipolar 5 V 0 V to 5 V ADG1404, ADG1408, ADG1204 AD1404, ADG1408, ADG1204 Serial, SPI ADA4841-x/ AD8021 1 2 3 Package MSOP, LFCSP MSOP, LFCSP MSOP, LFCSP LFCSP, LQFP LQFP, LFCSP Subset of the possible ADCs, ADC drivers, and multiplexers suitable for use with the AD5560. Visit http://www.analog.com for more options. Do not allow the MEASOUT output range to exceed the AIN range of the ADC. For the purposes of sharing ADCs among multiple DPS channels, note that the multiplexer is not absolutely necessary because the AD5560 MEASOUT path has a tristate mode. Rev. D | Page 34 of 68 Data Sheet AD5560 VREF VMID = (VTOP – VBOT)/2 VMID VTOP R 8.25R 2R HV DAC AMP LOW VOLTAGE OFFSET DAC DAC att VOS = (1 + 2/8.25) × (OFFSET DAC VOLTAGE) 8.25R 2R 2R 8.25R R VBOT VMIN 5R att REFGND MEASOUT OSD DAC IN R INTERNAL MEASI LOW INTERNAL MEASI HIGH 10R tri MI_x10 MEASURE CURRENT ISENSE AMP 5R 1kΩ MI_x20 mi mi_gain R 10R 2R att 2R 5R MEASURE VOLTAGE 1kΩ mv att att 5R 5R 5R 5R 5R DUTGND VSENSE AMP SENSE NOTES 1. att: ATTENUATION FOR EXTERNAL MEASOUT × 0.20 FOR OUTPUT VOLTAGE RANGE 0V TO 5.125V (WITH OVERRANGE) (VREF = 5V). tri: TRISTATE MODE mv: MEASURE VOLTAGE mi: MEASURE CURRENT mi_gain: MEASURE I GAIN SELECTION Figure 56. MI, MV, and MEASOUT Block Showing Gain Settings and Offset DAC Influence Rev. D | Page 35 of 68 07779-009 - AD5560 Data Sheet FORCE AMPLIFIER STABILITY Table 12. External Variables There are three modes for configuring the force amplifier: safe mode, autocompensation mode, and manual compensation mode. Manual compensation mode has highest priority, followed by safe mode, then autocompensation mode. Name CR RC CD RD IR Safe Mode Selected through Compensation Register 1 (see Table 20), this mode guarantees stability of the force amplifier under all conditions. Where the load is unknown, this mode is useful but results in a slow response. This is the power-on default of the AD5560. Description DUT capacitance with contributing ESR ESR in series with CR DUT capacitance with negligible ESR Loading resistance at the DUT Current range Min 10 nF Max 160 μF 1 mΩ 100 pF ~2 Ω ±5 μA 10 Ω 10 nF Infinity ±1.2 A Table 13. Internal Variables Name RZ Autocompensation Mode RP Using this mode, the user inputs the CR and ESR values, and the AD5560 decides the most appropriate compensation scheme for these load conditions. The compensation chosen is for an optimum tradeoff between ac response and stability. CC0:CC3 CF0:CF4 gmx Manual Compensation Mode This mode allows access to all of the internal programmable parameters to configure poles/zeros, which affect the dynamic performance of the loop. These variables are outlined in Table 12 and Table 13. Description Resistor in series with CC0, which contributes a zero. Resistor to 8 pF to contribute an additional pole Capacitors to ensure unconditional stability Capacitors to optimize ac performance into different CR, CD Transconductance of force amplifier input stage Min 500 Ω Max 1.6 MΩ 200 Ω 1 MΩ 100 pF 100 nF 4.7 nF 10 μF 40 μA/V 900 μA/V Figure 57 shows more details of the force amplifier block. AD5560 CF0 FORCE VOLTAGE LOOP RP: 200Ω TO 1MΩ 4.7nF CF1 22nF CF2 100nF CF3 470nF CF4 2.2µF EXTFORCE2 RSENSE 2 EXTFORCE1 RSENSE 1 20Ω 200Ω 2kΩ 8pF FORCE 20kΩ 100kΩ CC0 6kΩ CC1 100pF CC2 100pF 25kΩ 100kΩ FORCE DAC + gm AGND VSENSE – + – ×1 + – CC3 330pF SENSE + – CD RC CR RD DUTGND 3.3nF 07779-010 RZ: 500Ω TO 1.6MΩ Figure 57. Block Diagram of a Force Amplifier Loop Rev. D | Page 36 of 68 Data Sheet AD5560 POLES AND ZEROS IN A TYPICAL SYSTEM Typical closed loop systems have one dominant pole in the feedback path, providing −20 dB/decade gain roll off and 90° of phase shift so that the gain decreases to 0 dB where there is a conservative 90° of phase margin. The AD5560 has compensation options to help cope with the various load conditions that a DPS is presented with. MINIMIZING THE NUMBER OF EXTERNAL COMPENSATION COMPONENTS Note that, depending on the range of load conditions, not all external capacitors are required. CFx Pins There are five external CFx pins. All five pins are used in the autocompensation mode to choose a suitable capacitor, depending on the load being driven. To reduce component count, it is possible to connect just one capacitor, for instance, CF2 to the CF2, CF1, and CF0 pins. Therefore, when any of the smallest three external capacitors are selected, the same physical capacitor is used because it is connected to all three pins. A disadvantage here is that the larger CF2 capacitor should be bigger than optimal and may increase settling time of the whole circuit (particularly the measure current). CCx Pins To make the AD5560 stable with any unknown capacitor from 0 pF to 160 μF, all four CCx capacitors are required. However, if the range of load is from 0 pF to 20 µF, then CC3 can be omitted. Similarly, if the load range is from 0 pF to 2.2 µF, then CC2 and CC3 can be omitted. Only CC0 is required in autocompensation mode. Note that safe mode, which makes the device stable in any load from 0 pF to 160 μF, simply switches in all of the four CCx capacitors. Stability into 160 μF is assured only if all four capacitors are present; otherwise, the maximum capacitor for stability is reduced to 20 μF, 2.2 μF, or 220 nF, depending on how many capacitors are missing. EXTRA POLES AND ZEROS IN THE AD5560 The Effect of CCx CC0 is switched on at all times. CC3, CC2, and CC1 can be connected in addition to CC0 to slow down the force amplifier loop. In the ±500 mA range looking into a small load capacitor, with only CC0 connected, the ac gain vs. phase response results in ~90° of phase margin and a unity gain bandwidth (UGB) of ~400 kHz. The Effect of CFx The output of the AD5560 passes through a sense resistor to the DUT. Coupled with the load capacitor, this sense resistor can act as a low-pass filter that adds phase shift and decreases phase margin (particularly in the low current ranges where the sense resistors are large). Placing a capacitor in parallel with this sense resistor provides an ac feedforward path to the DUT. Therefore, at high frequencies, the DUT is driven through the CFx capacitor rather than through the sense resistor. Note that each CFx output has an output impedance of about 3 Ω. This is very small compared to the sense resistors of the low current ranges but not so for the highest current ranges. Therefore, the CFx capacitors are most effective in the low current ranges but are of lesser benefit in higher current ranges. As shown in the force amplifier diagram (see Figure 57), there is a pole at 1/( RSENSE × [CFx + CR]) and a zero at 1/[ RSENSE × CFx]. Therefore, the output impedance of each CFx output, at around 1 Ω, limits the improvement available by using the CFx capacitors. For a large load capacitance, there is still a pole at −1/[1 Ω × CR] above which the phase improvement is lost. If there is also a cable resistance to the DUT, or if CFx has significant ESR, this should be added to the 1 Ω to calculate the pole frequency. If CFx is chosen to be bigger than the load capacitance, it can dominate the settling time and slow down the settling of the whole circuit. Also, it directly affects the time taken to measure a current (RSENSE × CFx). The Effect of RZ When the load capacitance is known, RZ can be used to optimize the response of the AD5560. Because the CFx buffers have some output impedance of about 1 Ω, there is likely to be some additional resistance to the DUT. There can still be an output pole associated with this resistance and the load capacitance, CR, 1/[R0 × CR] (where R0 = the series/parallel combination of the sense resistor, the CFx output impedance, the CFx capacitor ESR, and the cable to DUT). This is particularly significant for larger load capacitances in any current range. By programming a zero into the loop response by setting RZ (in series with CC0), it is possible to cancel this pole. Above the frequency 1/[CC0 × RZ], the series resistance and capacitance begin to look resistive rather than capacitive, and the 90° phase shift and 20 dB/decade contributed by CC0 no longer apply. Note that, to cancel the load pole with the RZ zero, the load pole must be known to exist. Adding a zero to cancel a pole that does not exist causes an oscillation (perhaps the expected load capacitor is not present). Also, it is recommended to avoid creating a zero frequency lower than the pole frequency; instead, allow the zero frequency to be 2× or 3× higher than the calculated pole frequency. The Effect of RP RP can be used to ensure circuit stability when a poor load capacitor with significant ESR is present. Above the frequency, 1/[CR × RC], the DUT begins to look resistive. The ESR of the DUT capacitor, RC, contributes a zero at this frequency. The load capacitor, CR, is counted on to stabilize the system when the user has cancelled the load pole with the RZ zero. Just as the absence of CR under these circumstances can cause oscillations, the presence of ESR RC while nonzero RZ is used can cause Rev. D | Page 37 of 68 AD5560 Data Sheet stability problems. This is most likely to be the case when there are both a large CR and large RC. settings when using the manual compensation register (this algorithm is what the autocompensation method is based upon): The RP resistor is intended to solve this problem. Again, it is prudent not to cancel exact pole/zero cancellation with RZ and instead allow the zero to be 2× to 3× the frequency of the pole. It is best to be very conservative when using RZ to cancel the load pole. Choose a high zero frequency to avoid flat spots in the gain curve that extend bandwidth, and be conservative when choosing RP to create a pole. Aim to place the RZ zero at 5× the exact cancellation frequency and the RP pole at around 2× the exact cancellation frequency. The best solution here is to avoid this complexity by using a high quality capacitor with low ESR. 1. 2. COMPENSATION STRATEGIES Ensuring Stability into an Unknown Capacitor Up to a Maximum Value If the AD5560 has to be stable in a range of load capacitance from no load capacitance to an upper limit, then select manual compensation mode and, in Compensation Register 2, set the parameters according to the maximum load capacitance listed in Table 14. 3. Table 14. Suggested Compensation Settings for Load Capacitance Range of Unknown Value to Some Maximum Value 4. Capacitor Min Max 0 0.22 μF 0 2.2 μF 0 10 μF 0 20 μF 0 160 μF gm[1:0] RP[2:0] RZ[2:0] CC[3:1] CF[2:0] 2 2 2 2 2 0 0 0 0 0 0 0 0 0 0 000 001 010 011 111 2 3 4 4 4 5. 6. Table 14 assumes that the CCx and CFx capacitor values are those suggested in Table 8. Making a circuit stable over a range of load capacitances for no load capacitance or greater means that the circuit is overcompensated for small load capacitances, undercompensated for high load capacitances, or both. The previous choice settings, along with the suggested capacitor values, is a compromise between both. By compromising phase margin into the largest load capacitors, the system bandwidth can be increased, which means better performance under load current transient conditions. The disadvantage is that there is more overshoot during a large DAC step. To reduce this at the expense of settling time, it may be desirable to temporarily switch a capacitor range 5× or 10× larger before making a large DAC step. OPTIMIZING PERFORMANCE FOR A KNOWN CAPACITOR USING AUTOCOMPENSATION MODE The autocompensation mode decides what values of gmx, CCx CFx, RZ, and RP should be chosen for good performance in a particular capacitor. Both the capacitance and its ESR need to be known. To avoid creating an oscillator, the capacitance should not be overestimated and the ESR should not be underestimated. Use the following steps to determine compensation Use CR (the load capacitance with a series ESR) and RC (the ESR of that load capacitance) as inputs. Assume that CR has not been overestimated and that RC has not been underestimated. (Although, when the ESR RC is shown to have a frequency dependence, the lowest RC that occurs near the resonant frequency is probably a better guide. However, do not underestimate this ESR). a. CC0 is the suggested 100 pF. b. CFx capacitor values are as suggested, and they extend up to 2.2 µF (CF4). For faster settling into small capacitive loads, include smaller CFx values such as CF3 and CF2. If a capacitor is not included, then short the corresponding CFx pin to one that is. c. There is approximately 1 Ω of parasitic resistance, RC, from the AD5560 to the DUT (for example, the cable); RC = 1 Ω. Select gm[1:0] = 2, CC[3:1] = 000. This makes the input stage of the force amplifier; have gmx = 300 µA/V; deselect the compensation capacitors, CC1, CC2, CC3, so that only CC0 is active. Choose a CF[2:0] value from 0 to 4 to select the largest CFx capacitor that is smaller than CR. If CR < 100 nF, then set RZ[2:0] = 0, RP[2:0] = 0. This ends the algorithm. Calculate R0, the resistive impedance to the DUT, using the following steps: a. Calculate RS, the sense resistor, from the selected current range using RS = 0.5 V/IRANGE. b. Calculate RF, the output impedance, through the CFx capacitor, by using RF = 1.2 Ω + (ESR of CFx capacitor) c. Calculate RFM, a modified version of RF, which takes account of frequency dependent peaking, through the CFx buffers into a large capacitive load, by using RFM = RF/(1 + [2 × (CFx/2.2 μF)]) That is, RFM is up to 3× smaller than RF, when the selected CFx capacitor is large compared to 2.2 μF. Then calculate R0 = RC + (RS ||RFM) 7. 8. 9. Rev. D | Page 38 of 68 where RC takes its value from the assumptions in Step 2. If RC > (R0/5), then the ESR is large enough to make the DUT look resistive. Choose RZ[2:0] = 0, RP[2:0] = 0. This ends the algorithm Calculate the unity gain frequency (Fug), the ideal unity gain frequency of the force amplifier, from Fug = gmx/2πCC0. Using the previously suggested values (gm[1:0] = 2 gives gmx = 300 µA/V and CC0 = 100 pF), Fug calculates to 480 kHz. Calculate FP, the load pole frequency, using FP = 1/(2πR0CC0). Data Sheet AD5560 10. Calculate FZ, the ESR zero frequency, using FZ = 1/(2πRcCr). 11. If FP > Fug, the load pole is above the bandwidth of the AD5560. Ignore it with RZ[2:0] = 0, RP[2:0] = 0. This ends the algorithm 12. If RC < (R0/25), then the ESR is negligible. Attempt to cancel the load pole with RZ zero. Choose an ideal zero frequency of 2 × FP for some safety margin and then choose the RZ[2:0] value that gives the closest frequency on a logarithmic scale. This ends the algorithm 13. Otherwise, this is a troublesome window in which a load pole and a load zero can’t be ignored. Use the following steps: • To cancel the load pole at FP, choose an ideal zero frequency of 6 × FP (this is more conservative than the 2 × FP suggested earlier, but there is more that can go wrong with miscalculation). Then choose the RZ[2:0] value that gives the closest zero to this ideal frequency of 6 × FP on a logarithmic scale. • To cancel the ESR zero at FZ, choose an ideal pole frequency of 2 × FZ. • Then choose the RP[2:0] value that gives the closest pole to this ideal frequency of 2 × FZ on a logarithmic scale. This ends the algorithm ADJUSTING THE AUTOCOMPENSATION MODE A more complex alternative is to calculate the overall impedance at the expected unity gain bandwidth and use this to calculate an equivalent series CR and RC that have the same complex impedance at that particular frequency. DAC LEVELS This device contains all the dedicated DAC levels necessary for operation: a 16-bit DAC for the force amplifier, two 16-bit DACs for the clamp high and low levels, two 16-bit DACs for the comparator high and low levels, a 16-bit DAC to set a programmable open sense voltage, and a 16-bit offset DAC to bias or offset a number of DACs on chip (FORCE, CLL, CLH, CPL, CPH). FORCE AND COMPARATOR DACS The architecture of the main force amplifier DAC consists of a 16-bit R-2R DAC, whereas the comparator DACs are resistorstring DACs followed by an output buffer amplifier. This resistor-string architecture guarantees DAC monotonicity. The 16-bit binary digital code loaded to the DAC register determines at what node on the string the voltage is tapped off before being fed to the output amplifier. The comparator DAC is similarly arranged. The force and comparator DACs have a 25.62 V span, including overrange to enable offset and gain errors to be calibrated out. The transfer function for these 16-bit DACs is The autocompensation algorithm assumes that there is 1 Ω of resistance (RC) from the AD5560 to the DUT. If a particular application has resistance that differs greatly from this, then it is likely that the autocompensation algorithm is nonoptimal. If using the autocompensation algorithm as a starting point, consider that overstating the CR capacitance and understating the ESR RC is likely to give a faster response but could cause oscillations. Understating CR and overstating RC is more likely to slow things down and reduce phase margin but not create an oscillator. It is often advisable to err on the side of simplicity. Rather than insert a pole and zero at similar frequencies, it may be better to add none at all. Set RP[2:0] = RZ[2:0] = 0 to push them beyond the AD5560 bandwidth. DEALING WITH PARALLEL LOAD CAPACITORS In the event that the load capacitance consists of two parallel capacitors with different ESRs, it is highly likely that the overall complex impedance at the unity gain bandwidth is dominated by the larger capacitor and its ESR. Assuming that the smaller capacitor does not exist normally is a safer simplifying assumption. DAC CODE VOUT = 5.125 × VREF × − 5.125 × VREF × 216 OFFSET _ DAC _ CODE + DUTGND 216 where DAC CODE is X2 (see the Offset and Gain Registers section). CLAMP DACS The architecture of the clamp DAC consists of a 16-bit resistorstring DAC followed by an output buffer amplifier. This resistorstring architecture guarantees DAC monotonicity. The 16-bit binary digital code loaded to the DAC register determines at what node on the string the voltage is tapped off before being fed to the output amplifier. The clamp DACs have a 25.62 V span, including overrange, to enable offset and gain errors to be calibrated out. Rev. D | Page 39 of 68 AD5560 Data Sheet Table 15. Offset DAC Relationship with Other DACs, VREF = 5 V The transfer function for these 16-bit DACs is DAC CODE VCLH , VCLL = 5.125 × VREF × − 5.125 × VREF × 216 OFFSET _ DAC _ CODE + DUTGND 216 The transfer function for the clamp current value is DAC CODE − 32768 5.125 × VREF × 216 ICLL, ICLH = RSENSE × MI _ AMP _ GAIN where: RSENSE is the sense resistor. MI_AMP_GAIN is the gain of the MI amp (either 10 or 20). OSD DAC The OSD DAC is a 16-bit DAC function, again a resistor string DAC guaranteeing monotonicity. The 16-bit binary digital code loaded to the DAC register determines at what node on the string the voltage is tapped off before being fed to the output amplifier. The OSD function is used to program the voltage difference needed between the force and sense lines before the alarm circuit flags an error. The OSD DAC has a range of 0.62 V to 5 V. The transfer function is as follows: DAC CODE VOUT = VREF × 216 (1) The offset DAC does not affect the OSD DAC output range. DUTGND DAC Similarly, the DUTGND DAC (DGS) is a 16-bit DAC and uses a resistor string DAC to guarantee monotonicity. The 16-bit binary digital code loaded to the DAC register determines at what node on the string the voltage is tapped off before being fed to the output amplifier. This function is used to program the voltage difference needed between the DUTGND and AGND lines before the alarm circuit flags an error. The DUTGND DAC has a range of 0 V to 5 V. The transfer function for this 16-bit DAC is shown in Equation 1. The offset DAC does not affect the OSD DAC output range. OFFSET DAC Offset DAC Code 0 0 0 … 32,768 32,768 32,768 … 57,344 57,344 57,344 … 65,355 1 DAC Code1 0 32,768 65,535 … 0 32,768 65,535 … 0 32,768 65,535 … … DAC Output Voltage Range 0.00 12.81 25.62 … −12.81 0.00 12.81 … −22.42 −9.61 3.20 … Footroom limitations DAC code shown for 16-bit force DAC. OFFSET AND GAIN REGISTERS Each DAC level contains independent offset and gain control registers that allow the user to digitally trim offset and gain. These registers give the user the ability to calibrate out errors in the complete signal chain (including the DAC) using the internal m and c registers, which hold the correction factors. The digital input transfer function for the DACs can be represented as x2 = [x1 × (m + 1)/2n] + (c – 2n – 1) where: x2 is the data-word loaded to the resistor string DAC. x1 is the 16-bit data-word written to the DAC input register. m is the code in the gain register (default code = 216 – 1). n is the DAC resolution (n = 16). c is the code in the offset register (default code = 215). Offset and Gain Registers for the Force Amplifier DAC The force amplifier input (FIN) DAC level contains independent offset and gain control registers that allow the user to digitally trim offset and gain. There is one set of registers for the force voltage range: x1, m, and c. Offset and Gain Registers for the Comparator DACs In addition to the offset and gain trim, there is also a 16-bit offset DAC that offsets the output of each DAC on chip. Therefore, depending on headroom available, the input to the force amplifier can be arranged either symmetrically or asymmetrically about DUTGND but always within a voltage span of 25 V. Some extra gain is included to allow for system error correction using the m (gain) and c (offset) registers. The usable voltage range is −22 V to +25 V. Full scale loaded to the offset DAC does not give a useful output voltage range because the output amplifiers are limited by available footroom. Table 15 shows the effect of the offset DAC on other DACs in the device (clamp, comparator, and force DACs). The comparator DAC levels contain independent offset and gain control registers that allow the user to digitally trim offset and gain. There are seven sets of registers consisting of a combination of x1, m, and c, one set each for the five internal force current ranges and one set each for the two external high current ranges. Offset and Gain Registers for the Clamp DACs The clamp DAC levels contain independent offset and gain control registers that allow the user to digitally trim offset and gain. One set of registers covers the VSENSE range, the five internal force current ranges, and the two external high current ranges. Both clamp DAC x1 registers and their associated offset and gain registers are 16 bit. Rev. D | Page 40 of 68 Data Sheet AD5560 REFERENCE SELECTION The voltage applied to the VREF pin determines the output voltage range and span applied to the force amplifier, clamp, and comparator inputs and the current ranges. This device can be used with a reference input ranging from 2 V to 5 V. However, for most applications, a reference input of 5 V is able to meet all voltage range requirements. The DAC amplifier gain is 5.125, which gives a DAC output span of 25.625 V. The DACs have gain and offset registers that can be used to calibrate out system errors. In addition, the gain register can be used to reduce the DAC output range to the desired force voltage range. Using a 5 V reference and setting the m (gain) register to onefourth scale or 0x4000 gives an output voltage span of 6.25 V. Because the force DAC has 18 bits of resolution even with only one-fourth of the output voltage span, it is still possible to achieve 16-bit resolution in this 6.25 V range. The measure current amplifier has two gain settings, 10 and 20. The two gain settings allow users to achieve the quoted/specified current ranges with large or small voltage swings. The 20 gain setting is intended for use with a 5 V reference, and the 10 gain setting is for use with a 2.5 V reference. Both combinations ensure the specified current ranges. Other VREF/gain setting combinations should be used only to achieve smaller current ranges. See Table 27 for suggested references for use with the AD5560. CHOOSING AVDD/AVSS POWER SUPPLY RAILS As noted in the Specifications section, the minimum supply variation across the part is |AVDD − AVSS| ≥ 16 V and ≤ 33 V, AVDD ≥ 8 V, and AVSS ≤ −5 V. For the AD5560 circuits to operate correctly, the supply rails must take into account not only the force voltage range but also the internal DAC minimum voltage level, as well as headroom/footroom. The DAC amplifier gains VREF by 5.125, and the offset DAC centers that range about some chosen point. Because the DAC minimum voltage (VMIN) is used in other parts of the circuit (MEASOUT gain of 0.2), it is important that AVSS be chosen based on the following: AVSS ≤ −5.125 × (VREF × (OFFSET_DAC_CODE/216)) − AVSS_Headroom − VDUTGND − (RCABLE × ILOAD) where: AVSS_Headroom is the 2.75 V headroom (includes the RSENSE voltage drop). VDUTGND is the voltage range anticipated at DUTGND. RCABLE is the cable/path resistance. ILOAD is the maximum load current. When choosing AVDD, remember to take into account the specified current ranges. The measure current block has either a gain of 20 or 10 and must have sufficient headroom/ footroom to operate correctly. As the nominal, VRSENSE is ±0.5 V for the full-scale specified current flowing for all ranges. If this is gained by 20, the measure current amplifier output (internal node) voltage range is ±10 V with full-scale current and the default offset DAC setting. The measure current block needs ±2.25 V footroom/headroom for correct operation in addition to the ±0.5 V VRSENSE. For simplicity, when VREF = 5 V, minimum |AVDD − AVSS| = 31.125 V (VREF × 5.125 + headroom + footroom); otherwise, there can be unanticipated effects resulting from headroom/ footroom issues. This does not take into account cable loss or DUTGND contributions. Similarly, when VREF = 2.5 V, minimum |AVDD − AVSS| = 18.3 V and, when VREF = 2 V, minimum |AVDD − AVSS| = 16 V. The AD5560 is designed to settle fast into large capacitive loads; therefore, when slewing, the device draws 2× to 3× the current range from the AVDD/AVSS supplies. When supply rails are chosen, they should be capable of supplying each DPS channel with sufficient current to slew. CHOOSING HCAVSSx AND HCAVDDx SUPPLY RAILS Selection of HCAVSSx and HCAVDDx supplies is determined by the EXTFORCE1 and EXTFORCE2 output ranges. The supply rails chosen must take into account headroom and footroom, DUTGND voltage range, cable loss, supply tolerance, and VRSENSE. If diodes are used in series with the HCAVSSx and HCAVDDx supplies pins (shown in Figure 59), the diode voltage drop should also be factored into the supply rail calculation. The AD5560 is designed to settle fast into large capacitive loads in high current ranges; therefore, when slewing, the device draws 2× to 3× the current range from the HCAVSSx and HCAVDDx supplies. When choosing supply rails, ensure that they are capable of supplying each DPS channel with sufficient current to slew. All output stages of the AD5560 are symmetrical; they can source and sink the rated current. Supply design/bypassing should account for this. POWER DISSIPATION The maximum power dissipation allowed in the EXTFORCE1 stage is 10 W, whereas in the EXTFORCE2 stage, it is 5 W. Take care to ensure that the device is adequately cooled to remove the heat. The quiescent current is ~0.8 W with an internal current range enabled and ~1 W with external current ranges, EXTFORCE1 or EXTFORCE2, enabled. This device is specified for performance up to 90°C junction temperature (TJ). Rev. D | Page 41 of 68 AD5560 Data Sheet PACKAGE COMPOSITION AND MAXIMUM VERTICAL FORCE The exposed pad and leads of the TQFP package have a 100% tin finish. The exposed paddle is connected internally to AVSS. The simulated maximum allowable force for a single lead is 0.18 lbs; total allowable force for the package is 11.5 lbs. The quoted maximum force may cause permanent lead bending. Other package failure (die, mold, board) may occur first at lower forces. SLEW RATE CONTROL There are two methods of achieving different slew rates using the AD5560. One method is using the programmable slew rate feature that gives eight programmable rates. The second method is using the ramp feature and an external clock. Programmable Slew Rate Eight programmable modes of slew rates are available to choose from through the serial interface, enabling the user to choose different rates to power up the DUT. The different slew rates are achieved by variation in the internal compensation of the force DAC output amplifier. The slew rates available are 1.000 V/µs, 0.875 V/µs, 0.750 V/µs, 0.625 V/µs, 0.5 V/µs, 0.4375 V/µs, 0.35V µs, and 0.313 V/µs. Ramp Function Included in the AD5560 is a ramp function that enables the user to apply a rising or falling voltage ramp to the DUT. The user supplies a clock, RCLK, to control the timing. This function is controlled via the serial interface and requires programming of a number of registers to determine the end value, the ramp size, and the clock divider register to determine the update rate. The contents of the FIN DAC x1 register are the ramp start value. The user must load the end code register and the step size register. The sign is now generated from the difference between the FIN DAC x1 register and the end code; then the step size value is added to or subtracted from FIN DAC x1, calibrated and stored. The user must supply a clock to the RCLK pin to load the new code to the DAC. The output settles in 1.2 µs for a step of 10 mV with CDUT in the lowest range of <0.2 µF. While the output is settling, the next step is calculated to be ready for the next ramp clock. The calibration engine is used here; therefore, there is a calibration delay of 1.2 µs. The ramp timing is controlled in two ways: by a user-supplied clock (RCLK) and by a clock divider register. This gives the user much flexibility over the frequency of the ramp steps. The ramp typically starts after (2 × clock divider + 2) clocks, although there can be a ±1 clock delay due to the asynchronous nature of RCLK. The external clock can be a maximum of 833 kHz when using clock divider = 1. Faster RCLK speeds can be used, but the fastest ramp rate is linked into the DAC calibration engine. For slower ramp rates, an even slower RCLK can be used. The step sizes are in multiples of 16 LSBs. If the code previous to the end code is not a multiple of this step size, the last step is smaller. If the ramp function must be interrupted at any stage during the ramp, write the interrupt ramp command. The FIN DAC x1 stops ramping at the current value and returns to normal operation. The fastest ramp rate is 0.775 V/µs (for a 5 V reference and an 833 kHz clock using a 2032 LSB step size and divider = 1). The slowest ramp rate is 24 µV/µs (for a 5 V reference and an 833 kHz clock using a 16 LSB step size and divider = 255). Even slower ramps can be achieved with slower SCLK. The ramp continues until any of the following occurs: • • • It reaches the end code. An interrupt ramp is received from the user. If any enabled alarm triggers, the ramp stops to allow the user to service the activated alarm. While the device is in ramp mode, the only command that the interface accepts is an interrupt ramp. No other commands should be written to the device while ramping because they are ignored. Rev. D | Page 42 of 68 Data Sheet AD5560 NEW RAMP CHANGE STEP SIZE? YES SELECT RAMP SIZE NO CHANGE CLOCK DIVISION? YES PROGRAM CLOCK DIVIDER YES WRITE NEW FIN ×1 DAC VALUE NO CHANGE RAM P START? NO WRITE RAMP END CODE RAMP MODE ENABLE RAMP UPDATE DAC CODE? YES CALCULATE NEXT DAC CODE LOAD DAC NO INTERRUPT RAMP? ALARM? YES DO NOT LOAD DAC. RETAIN PREVIOUS VALUE NO RAMP COMPLETE? YES RETURN TO NORMAL MODE TERMINATE RAMP Figure 58. Flow Chart for Ramp Function Rev. D | Page 43 of 68 07779-011 NO AD5560 Data Sheet SERIAL INTERFACE The AD5560 contains an SPI-compatible interface operating at clock frequencies of up to 50 MHz. To minimize both the power consumption of the device and on-chip digital noise, the interface powers up fully only when the device is being written to, that is, on the falling edge of SYNC. SPI INTERFACE The serial interface is 2.5 V LVTTL-compatible when operating from a 2.3 V to 3.6 V DVCC supply. It is controlled by the following four pins: • • • • SYNC (frame synchronization input) SDI (serial data input pin) SCLK (clocks data in and out of the device) SDO (serial data output pin for data readback) SPI WRITE MODE The AD5560 allows writing of data via the serial interface to every register directly accessible to the serial interface, which is all registers except the DAC registers. The serial word is 24 bits long. The serial interface works with both a continuous and a burst (gated) serial clock. Serial data applied to SDI is clocked into the AD5560 by clock pulses applied to SCLK. The first falling edge of SYNC starts the write cycle. At least 24 falling clock edges must be applied to SCLK to clock in 24 bits of data before SYNC is taken high again. The input register addressed is updated on the rising edge of SYNC. For another serial transfer to take place, SYNC must be taken low again. SDO OUTPUT The SDO output in the AD5560 is a weak/slow output driver. If using readback or the daisy-chain function, the frequency of SCLK must be reduced so that SDO can operate properly. The SCLK frequency is dependent on the DVCC supply voltage used; see Table 2 for details and the following example: BUSY FUNCTION BUSY is a digital open-drain output that indicates the status of the AD5560. All writes drive the BUSY output low for some period of time; however, events that use the calibration engine, such as all DAC x1 writes, drive it lower for a longer period of time while the calculations are completed. For the DACs, the value of the internal data (x2) loaded to the DAC data register is calculated each time the user writes new data to the corresponding x1 register. During the calculation of x2, the BUSY output goes low and x2 writes are pipelined; therefore, x2 writes can still be presented to the device while BUSY is still low (see the Register Update Rates section). The DAC outputs update immediately after BUSY goes high. Writes to other registers must be handled differently and should either watch the BUSY pin or be timed. While BUSY is low, the user can continue writing new data to any control register, m register, or c register but should not complete the writing process (SYNC returning high) until the BUSY signal has returned high. BUSY also goes low during power-on reset, as well as when a low level is detected on the RESET pin. BUSY writes to the system control register, compensation register, alarm register, and diagnostic register; m or c registers do not involve the calibration engine, thus speeding up writing to the device. LOAD FUNCTION The AD5560 device contains a function with which updates to multiple devices can be synchronized using the LOAD function. There is not a dedicated pin available for this function; however, either the CLEN or HW_INH pin can be used as a LOAD input (selection is made in the system control register, Address 0x1, Bits[8:7]). Maximum SCLK = 15 MHz, then DVCC = 2.7 V to 3.3 V When selected as the LOAD function, the pin no longer operates in its previous function (power-on default for each of these pins is a CLEN or HW_INH function). Maximum SCLK = 20 MHz, then DVCC = 4.5 V to 5.5 V The LOAD function controls the following registers: RESET FUNCTION • • • • • • Maximum SCLK = 12 MHz, then DVCC = 2.3 V to 2.7 V RESET is a level-sensitive input. Bringing the RESET line low resets the contents of all internal registers to their power-on reset state. The falling edge of RESET initiates the reset process; BUSY goes low for the duration, returning high when the RESET process is complete. This sequence takes 300 µs maximum. Do not write to the serial interface while BUSY is low handling a RESET command. When BUSY returns high, normal operation resumes, and the status of the RESET pin is ignored until it goes low again. 0x8 FIN DAC x2 register 0xD CLL DAC x2 register 0x10 CLH DAC x2 register 0x4 Compensation Register 1 0x5 Compensation Register2 0x2 DPS Register1 (only current ranges, Bits[13:11]) There is, however, an alternate method for updating and using the CLEN and HW_INH pins in their normal function. Rev. D | Page 44 of 68 Data Sheet AD5560 If Bits[8:7] of the system control register (Address 0x1) are high, then the CLEN and HW_INH operate as normal, and the update waits until BUSY goes high (this way multiple channels can still be synchronized by simply tying BUSY pins together). REGISTER UPDATE RATES As mentioned previously, the value of the x2 register is calculated each time the user writes new data to the corresponding x1 register. The calculation is performed by a three stage process. The first two stages take 600 ns each, and the third stage takes 300 ns. When the write to one of the x1 registers is complete, the calculation process begins. The user is free to write to another register provided that the write operation does not finish until the first stage calculation is complete, that is, 600 ns after the completion of the first write operation. Rev. D | Page 45 of 68 AD5560 Data Sheet CONTROL REGISTERS DPS AND DAC ADDRESSING A no operation (NOP) command performs no function within the device. This code may be useful when performing a readback function where a change of DAC or DPS register is not required. The serial word assignment consists of 24 bits, as shown in Table 16. All write-to registers can be read back. There are some read-only registers (Address 0x43 and Address 0x44). DAC x2 registers are not available for readback. Table 16. Serial Word Assignment B23 R/W [B22:B16] Address bits [B15:B0] Data bits Table 17. Read or Write Register Addressing Address 0x0 0x1 Register NOP System control register Default 0x0000 0x0000 Data Bits, MSB First NOP command; performs no operation. Bit Name Function 15 14 TMP[1:0] 13 12 Gain[1:0] 11 FINGND 10 CPO 9 PD 8 7 LOAD 6:0 Unused Thermal shutdown bits. TMP1, TMP0 allow the user to program the thermal shutdown temperature of operation. TMP Action 0 Shutdown at a TJ of 130°C (power-on default) 1 Shutdown at a TJ of 120°C 2 Shutdown at a TJ of 110°C 3 Shutdown at a TJ of 100°C MEASOUT output range. The MEASOUT range defaults to the voltage force span for voltage and current measurements (this is ±12.81 V), which includes some overrange to allow for error correction. The MEASOUT range can be reduced by using the gain bits. This allows for use of asymmetrical supplies or for use of a smaller input range ADC. MEASOUT gain settings do not translate the low voltage temperature sensor signal (TSENSE). Gain MEASOUT Gain MI Gain 0 1 20 1 1 10 2 0.2 20 3 0.2 10 To allow for system error correction, there is an additional gain of 0.125 for the force function if this error correction is used as intended; then the output range on MEASOUT scales accordingly (see Table 9). Writing a 1 to FINGND switches the positive input of the force amplifier to GND; when 0, the input of the force amplifier is connected to the output of the force DAC. Write a 1 to the CPO bit to enable a simple window comparator function. In this mode, only one comparator output is available (CPOH/CPO). This provides two bits of information. The compared value is either inside or outside the window and enables the user to bring only one line back to the controller per DPS device. This bit powers down the force amplifier block. Note that the amplifier must be powered up but inhibited (SW-INH or HW_INH), to meet leakage specifications. A 0 powers this block down (default). Updates to registers listed in the following LOAD function column do not occur until the active LOAD pin is brought low (or in the case of LOAD 3, until BUSY goes high). LOAD 0 LOAD Function Default operation, CLEN and HW_INH function normally. 1 The CLEN pin is a LOAD input. 2 The HW_INH pin is a LOAD input. 3 The device senses the BUSY open-drain pin and doesn't update until that goes high. No LOAD hardware pin. CLEN and HW_INH function normally. Set to 0. Rev. D | Page 46 of 68 Data Sheet AD5560 Table 18. DPS Register 1 Address 0x2 Default 0x0000 Bit 15 Name SW-INH Data Bits, MSB First Function This bit enables the force amplifier when high and disables the amplifier when low. This bit is AND’d with the HW_INH hardware inhibit pin. 14 13 12 11 Reserved I[2:0] Reserved, set to 0. Current range addressing. These bits allow selection of the required current range. 10 CMP[1:0] 9 8 7 6 5 ME[3:0] 4 CLEN 3:0 Unused I Action 0 ±5 µA current range. 1 ±25 µA current range. 2 ±250 µA current range. 3 ±2.5 mA current range. 4 ±25 mA current range. 5 External Range 2. 6 External Range 1. 7 Reserved. Comparator function. CMP1 acts as a comparator output enable, whereas CMP0 selects between a comparing DUT current or voltage; by default, the comparators are high-Z on power-on. CMP Action 0 Comparator outputs high-Z. 1 Comparator outputs high-Z. 2 Compare DUT current. 3 Compare DUT voltage. Bits ME[3:0] allow selection of the required measure mode, allowing the MEASOUT line to be disabled; connect to the temperature sensor or enable it for measurement. ME3 is MEASOUT enable/disable; when high, MEASOUT is enabled, and ME[2:0] can be used to preselect the measuring parameter. Where a number of MEASOUT lines are connected together and passed to a common ADC, this function can allow for much faster measurement time between channels because the slew time of the measurement buffer is reduced. For details on diagnostic functions, see Address 0x7, the diagnostic register. ME[2:0] Action 0 MEASOUT high-Z. 1 Connect MEASOUT to ISENSE. 2 Connect MEASOUT to VSENSE. 3 Connect MEASOUT to KSENSE. 4 Connect MEASOUT to TSENSE. 5 Connect MEASOUT to DUTGND SENSE. 6 Connect MEASOUT to diagnostic functions: DIAG A (see Address 0x7). 7 Connect MEASOUT to diagnostic functions: DIAG B (see Address 0x7). Clamp enable; set high to enable the clamp; set low to disable the clamp. This bit is OR’d with the hardware CLEN pin. Set to 0. Rev. D | Page 47 of 68 AD5560 Data Sheet Table 19. DPS Register 2 Address 0x3 Default 0x0000 Bit 15 Name SF0 14 13 12 SR[2:0] 11 GPO 10 9 SLAVE, GANGIMODE 8 INT10K 7 Guard high-Z 6:0 Unused Data Bits, MSB First Function System force and sense line addressing, SF0. Bit SF0 addresses each of the different combinations of switching the system force and sense lines to the force and sense pins at the DUT. Guard High-Z (Bit 7) SFO SYS_SENSE Pin SYS_FORCE Pin GUARD/SYS_DUTGND Pin 0 0 Open Open Guard 0 1 Sense Force Guard 1 0 Open Open Open 1 1 Sense Force DUTGND Slew rate control, SR2, SR1, SR0. Selects the slew rate for the main DAC output amp. SR Action 0 1 V/μs 1 0.875 V/μs 2 0.75 V/μs 3 0.62 V/μs 4 0.5 V/μs 5 0.43 V/μs 6 0.35 V/μs 7 0.3125 V/μs General purpose output bit. The GPO bit can be used for any function, such as disconnecting the decoupling capacitor to help speed up low current testing. Ganging multiple devices increases the current drive available. Use these bits to enable selection of the ganging mode and place the device in slave or master mode. In default operation, each device is a master (gang of one). Figure 54 shows how the device is configured in this mode. SLAVE Action 0 Master: MASTER_OUT = internally connects to active EXTFORCE1/ EXTFORCE2 output 1 Master: MASTER_OUT = master MI 2 SLAVE FV to EXTFORCE1/EXTFORCE2 connected internally to close the FVAMP loop 3 SLAVE FI Setting this bit high allows the user to connect an internal sense short resistor of 10 kΩ between the force and the sense lines (closes SW11). This resistor is actually made up of series 4 kΩ resistors followed by a 2 kΩ switch and another 4 kΩ resistor. There is a 10 kΩ resistor that can be connected between the FORCE and SENSE pins by use of SW11. This 10 kΩ resistor is intended to maintain a force/sense connection when a DUT is not in place. It is not intended to be connected when measurements are being made because this defeats the purpose of the OSD circuit in identifying an open circuit between FORCE and SENSE. In addition, the sense path has a 2.5 kΩ resistor in series; therefore, if the 10 kΩ switch is closed, errors may become apparent when in high current ranges. Set this bit high to high-Z the guard amplifier. This is required if using the GUARD/ SYS_DUTGND pin in the SYS_DUTGND function. Set to 0. Rev. D | Page 48 of 68 Data Sheet AD5560 The AD5560 has three compensation modes. The power-on default mode is SAFEMODE enabled. This ensures that the device is stable into any load. Use Compensation Register 1 to configure the device for autocompensation, where the user inputs the CDUT and ESR bits, and the AD5560 chooses the most appropriate compensation scheme for these load conditions. Table 20. Compensation Register 1 Address 0x4 Default 0x0000 Bit 15 14 13 12 Name CDUT[3:0] 11 10 9 8 ESR[3:0] 7 SAFEMODE 6:0 Reserved Data Bits, MSB First Function Use these control bits to tell the device how much capacitive load there is so that the device can optimize the compensation used. Do not overestimate CDUT because this can cause oscillations. Underestimating CDUT gives suboptimal but stable performance. CDUT CDUT Min CDUT Max 0 0 nF 50 nF 1 50 nF 83 nF 2 83 nF 138 nF 3 138 nF 229 nF 4 229 nF 380 nF 5 380 nF 630 nF 6 630 nF 1.1 µF 7 1.1 µF 1.7 µF 8 1.7 µF 2.9 µF 9 2.9 µF 4.8 µF 10 4.8 µF 7.9 µF 11 7.9 µF 13 µF 12 13 µF 22 µF 13 22 µF 36 µF 14 36 µF 60 µF 15 60 µF 160 µF Use these control bits to tell the device how much ESR there is in series with CDUT so that the device can optimize the compensation used. Do not underestimate ESR because this can cause oscillations. Overestimating ESR gives suboptimal but stable performance. ESR ESR Min ESR Max 0 0 mΩ 1 mΩ 1 1 mΩ 1.8 mΩ 2 1.8 mΩ 3.4 mΩ 3 3.4 mΩ 6.3 mΩ 4 6.3 mΩ 12 mΩ 5 12 mΩ 21 mΩ 6 21 mΩ 40 mΩ 7 40 mΩ 74 mΩ 8 74 mΩ 140 mΩ 9 140 mΩ 250 mΩ 10 250 mΩ 460 mΩ 11 460 mΩ 860 mΩ 12 860 mΩ 1500 mΩ 13 1500 mΩ 2900 mΩ 14 2900 mΩ 5400 mΩ 15 6400 mΩ 10,000 mΩ SAFEMODE = 0 overrides values in Compensation Register 1 to make the force amplifier stable under most load conditions. This mode is useful if it is unknown what the DPS is driving, but it does result in an extremely slow response. The default operation on power-on or reset is SAFEMODE. SAFEMODE settings are always gm[1:0] = 2, RP[2:0] = 0, RZ[2:0] = 0, CC[3:1] = 111, CF[2:0] = 5, and CC0 = 1. Set this bit high to enable autocompensation. Set to 0. Rev. D | Page 49 of 68 AD5560 Data Sheet Table 21. Compensation Register 2 Address 0x5 Default 0x0110 Bit 15 Name Manual compensation 14 13 12 RZ[2:0] 11 10 9 RP[2:0] 8 7 gm[1:0] Data Bits, MSB First Function The AD5560 can be manually configured to compensate the force amplifier into a wide range of load conditions. When this bit is high, manual compensation mode is active, and it overrides the settings of Compensation Register 1. Readback when in manual compensation mode returns the compensation settings loaded to the force amplifier and loaded to this register. Similarly, when in autocompensation mode, readback of this register address returns the compensation settings of the force amplifier. However, readback of this register address when in safe mode does not reflect SAFEMODE settings. SAFEMODE settings are gm[1:0] = 2, RP[2:0] = 0, RZ[2:0] = 0, CC[3:1] = 111, CF[2:0] = 5, and CC0 = 1. Set the value of RZ to add a zero at the following frequencies. This calculation assumes that CC0 = 100 pF. RZ RZx(Ω) FZ (Hz) 01 500 3.2 M 1 1.6 k 1M 2 5k 320 k 3 16 k 100 k 4 50 k 32 k 5 160 k 10 k 6 500 k 3.2 k 7 1.6 M 1k Set the value of RP to add an additional pole. There is an internal 8 pF capacitor to provide an RC filter, creating a pole at one of the following frequencies. RP[2:0] RP (Ω) FP (Hz) 200 100 M 01 1 675 29 M 2 2280 8.7 M 3 7700 2.6 M 4 26 k 760 k 5 88 k 220 k 6 296 k 67 k 7 1M 20 k Set the transconductance of the force amplifiers input stage. The gain bandwidth (GBW) of the force voltage loop is equal to gmx/CC0. The following values assume CC0 = 100 pF. gmx gmx (µA/V) GBW (Hz) 0 40 64 k 1 80 130 k 300 480 k (default) 900 1.3 M 1 2 3 6 5 4 CF[2:0] These bits determine which feedforward capacitor CFx is switched in. CFx 0 1 2 3 4 Action None CF0 CF1 CF2 CF3 CF4 51 6 7 1 None None 3 CC3 Connect CC3 in series with 100 kΩ1 2 CC2 Connect CC2 in series with 25 kΩ1 1 CC1 0 Reserved Connect CC1 in series with 6 kΩ1 0 This item corresponds to a SAFEMODE setting (SAFEMODE is the power-on default setting). Rev. D | Page 50 of 68 Data Sheet AD5560 Register 0x6 allows the user to enable or disable any of the alarm flags that are not required. If disabled, that particular alarm no longer flags on the appropriate open-drain pin; however, the alarm status is still available in both of the alarm status registers (Address 0x43 and Address 0x44). Table 22. Alarm Setup Register Address 0x6 Default 0x0000 Data Bits, MSB First Bit Name Function 15 Latched Set this latched bit high to program the open-drain TMPALM alarm pin as a latched output; TMPALM leave low for an unlatched alarm pin (default). 14 Disable Set this bit high to disable the open-drain TMPALM alarm pin; leave low to leave enabled (default). TMPALM 13 Latched OSALM 12 Disable OSALM 11 Latched DUTALM 10 Disable DUTALM 9 Latched CLALM Disable CLALM 8 Set this latched bit high to program the OSALM as a latched alarm on the open-drain KELALM pin; leave low for an unlatched alarm pin (default). Set this bit high to disable the OSALM alarm function flagging the open-drain KELALM pin; leave low to remain enabled (default). The disable GRDALM, DUTALM, and OSALM alarm functions share one open-drain KELALM alarm pin. These bits allow users to choose if they wish to have all or selected information flagged to the alarm pin. Set this latched bit high to program the DUTALM as a latched alarm on the open-drain KELALM pin; leave low for an unlatched alarm pin (default). Set this bit high to disable the DUTALM alarm function flagging the open-drain KELALM pin. Leave low to leave enabled (default). The disable GRDALM, DUTALM, and OSALM alarm functions share one open drain KELALM alarm pin. These bits allow users to choose if they wish to have all or any information flagged to the alarm pin. The DUTGND pin has a 50 µA pull-up to allow for detection of an error in the DUTGND path. Setting this bit high also disables the 50 µA pull-up. Set this latched bit high to program the open-drain CLALM clamp alarm pin as a latched output; leave low for an unlatched alarm pin (default). Set this bit high to disable the open drain CLALM alarm pin; leave low to leave enabled (default). 7 Latched GRDALM 6 Disable GRDALM Set this latched bit high to program the GRDALM as a latched alarm on the open-drain KELALM pin; leave low for an unlatched alarm pin (default). Set this bit high to disable the GRDALM alarm function flagging the open-drain KELALM pin; leave low to leave enabled (default). The disable GRDALM, DUTALM and OSALM alarm functions share one open-drain KELALM alarm pin. These bits allow users to choose if they wish to have all or any information flagged to the KELALM alarm pin. 5:0 Unused Set to 0. Rev. D | Page 51 of 68 AD5560 Data Sheet Table 23. Diagnostic Register Address 0x7 Default 0x0000 Bit 15 14 13 12 Name DIAG select[3:0] 11 10 9 8 7 TSENSE select[3:0] Data Bits, MSB First Function DIAG select selects the set of diagnostic signals that can be made available on MEASOUT. First, use MEASOUT addressing (DPS Register 1) to select either the DIAG A or the DIAG B node to be made available on MEASOUT. Selected DIAG Select Measure Block DIAG A DIAG B 0:3 Disabled Disabled Disabled 4 Force amplifier Disabled Disabled 5 EXTFORCE1A EXTFORCE2A 6 FINP FINM 7 Output 2.5 mA Output 25 mA 8 Measure block VPTAT low VPTAT high VTSD low (ref V 9 VTSD high (ref V for +130°C) for −273°C) 10 MI VMID Code 11 MV VMIN Code 12 DAC block FORCE DAC VOS DAC 13 CLL DAC CLH DAC 14 CPL DAC CPH DAC 15 OSD DAC DGS DAC VPTAT low/VPTAT high are temperature sensor devices in the middle of the enabled power stage, which gives a voltage level that can be mapped back to the VTSD low and VTSD high reference points to get a temperature value. These sensors are used in the thermal shutdown feature. See the Die Temperature Sensor and Thermal Shutdown section. VMID code is the midscale voltage of the DACs; the offset DAC has a direct effect on this voltage level. VMIN code is the zero-scale voltage of the DACs; again the offset DAC has a direct effect. The following codes allow selection of one of three sets of eight thermal diodes. The D+ of the selected thermal diode is available on the GPO pin; the D− is on the AGND. These thermal diodes are located across the die, in the cool parts and in the power stages. Diodes [16:23] are located in the force amplifier NPNs (power output devices for supplying current). Similarly, Diodes [24:31] are located in the force amplifier PNP devices (output devices for sinking current). TSENSE Select 0:7 8 Selected Thermal Block N/A—normal GPO operation Cool block 9 10 11 12 13 14 15 16 17 18 Force amplifier PNPs 19 20 21 22 23 Rev. D | Page 52 of 68 Connected Sensor No sensor connected Cool end of high current drivers, hot side of digital block 25 mA output stage Hottest part of sensitive measurement circuitry and cool part of force amplifier Coolest end of force amplifier block Coolest end of DACs Beside TSENSE available on MEASOUT Hottest part of DACs Cool side of digital block 1A-1 1A-2 2A (similar location to VPTAT low for EXTFORCE2 range) 1B-1 (similar location to VPTAT low for EXTFORCE1 range) 1B-2 2B 1C-1 1C-2 Data Sheet Address 0x7 Default 0x0000 AD5560 Data Bits, MSB First Bit Name 6 5 Test Force AMP[1:0] 4:0 Reserved Function 24 25 26 Force amplifier NPNs 1A-1 1A-2 2A (similar location to VPTAT high for EXTFORCE2 range) 1B-1 (similar location to VPTAT high for EXTFORCE1 27 range) 28 1B-2 29 2B 30 1C-1 31 1C-2 These register bits allow disabling of stages of the force amplifier. They can be used to ensure connectivity in each parallel stage. The enabled stage depends also on which current range is selected. Test Force Current Range Amplifier Enabled Stage EXTFORCE1 0 All stages EXTFORCE1 1 EXTFORCE1C EXTFORCE1 2 EXTFORCE1B EXTFORCE1 3 EXTFORCE1A EXTFORCE2 0 All stages EXTFORCE2 1 Reserved EXTFORCE2 2 EXTFORCE2B EXTFORCE2 3 EXTFORCE2A Set to 0. Rev. D | Page 53 of 68 AD5560 Data Sheet Table 24. Other Registers Address 0x8 0x9 0xA 0xB 0xC 0xD 0xE 0xF 0x10 0x11 0x12 0x13 0x14 0x15 0x16 0x17 0x18 0x19 0x1A 0x1B 0x1C 0x1D 0x1E 0x1F 0x20 0x21 0x22 0x23 0x24 0x25 0x26 0x27 0x28 0x29 0x2A 0x2B 0x2C 0x2D 0x2E 0x2F 0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x3A 0x3B Register FIN DAC x1 FIN DAC m FIN DAC c Offset DAC x OSD DAC x CLL DAC x1 CLL DAC m CLL DAC c CLH DAC x1 CLH DAC m CLH DAC c CPL DAC x1 5 μA range CPL DAC m 5 μA range CPL DAC c 5 μA range CPL DAC x1 25 μA range CPL DAC m 25 μA range CPL DAC c 25 μA range CPL DAC x1 250 μA range CPL DAC m 250 μA range CPL DAC c 250 μA range CPL DAC x1 2.5 mA range CPL DAC m 2.5 mA range CPL DAC c 2.5 mA range CPL DAC x1 25 mA range CPL DAC m 25 mA range CPL DAC c 25 mA range CPL DAC x1 EXT Range 2 CPL DAC m EXT Range 2 CPL DAC c EXT Range 2 CPL DAC x1 EXT Range 1 CPL DAC m EXT Range 1 CPL DAC c EXT Range 1 CPH DAC x 1 5 μA range CPH DAC m 5 μA range CPH DAC c 5 μA range CPH DAC x1 25 μA range CPH DAC m 25 mA range CPH DAC c 25 μA range CPH DAC x1 250 μA range CPH DAC m 250 μA range CPH DAC c 250 μA range CPH DAC x1 2.5 mA range CPH DAC m 2.5 mA range CPH DAC c 2.5 mA range CPH DAC x1 25 mA range CPH DAC m 25 mA range CPH DAC c 25 mA range CPH DAC x1 EXT Range 2 CPH DAC m EXT Range 2 CPH DAC c EXT Range 2 CPH DAC x1 EXT Range 1 CPH DAC m EXT Range 1 Default 0x8000 0xFFFF 0x8000 0x8000 0x1FFF 0x0000 0xFFFF 0x8000 0xFFFF 0xFFFF 0x8000 0x0000 0xFFFF 0x8000 0x0000 0xFFFF 0x8000 0x0000 0xFFFF 0x8000 0x0000 0xFFFF 0x8000 0x0000 0xFFFF 0x8000 0x0000 0xFFFF 0x8000 0x0000 0xFFFF 0x8000 0xFFFF 0xFFFF 0x8000 0xFFFF 0xFFFF 0x8000 0xFFFF 0xFFFF 0x8000 0x0000 0xFFFF 0x8000 0xFFFF 0xFFFF 0x8000 0xFFFF 0xFFFF 0x8000 0xFFFF 0xFFFF Data Bits, MSB First x1 DAC register; D15 to D0, MSB first. m register; D15 to D0, MSB first. c register; D15 to D0, MSB first. D15 to D0. D15 to D0. D15 to D0; the low clamp level can only be negative; the MSB is always 0 to ensure this. D15 to D0. D15 to D0. D15 to D0; the high clamp level can only be positive; the MSB is always 1 to ensure this. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. Rev. D | Page 54 of 68 Data Sheet AD5560 Address 0x3C 0x3D 0x3E Register CPH DAC c EXT Range 1 DGS DAC Ramp end code Default 0x8000 0x3333 0x0000 0x3F Ramp step size 0x0001 0x40 RCLK divider 0x0001 0x41 0x42 Enable ramp Interrupt ramp 0x0000 0x0000 Data Bits, MSB First D15 to D0. D15 to D0 DUTGND SENSE DAC, 0 V to 5 V range. D15 to D0; this is the ramp end code. The ramp start code is the code that is in the FIN DAC register. 0000 0000 D6 to D0. D6:D0 set the ramp step size in increments of 16 LSB per code, with a 5 V reference, 16 LSB = 6.1 mV. For example, 000 0000 = 16 LSBs (6.1 mV) step 000 0001 = 16 LSBs (6.1 mV) step … 111 1111 = 2032 LSBs (775 mV) step. 0000 0000 D7 to D0. D7:D0 set the RCLK divider. 0000 0000 = ÷ 1 0000 0001 = ÷ 1 0000 0010 = ÷ 2 0000 0011 = ÷ 3 … 1111 1111 = ÷ 255 0xFFFF to enable. 0x0000 to interrupt. Rev. D | Page 55 of 68 AD5560 Data Sheet Table 25. Alarm Status and Clear Alarm Status Register Address 0x43 Register Alarm status Default 0x0000 0x44 Alarm status and clear alarm 0x0000 0x45 0x46 0x47 0x48 0x49 0x4A 0x4B to 0x7F CPL DAC x1 CPL DAC m CPL DAC c CPH DAC x1 CPH DAC m CPH DAC c Reserved 0x0000 0xFFFF 0x8000 0xFFFF 0xFFFF 0x8000 Data Bits, MSB first This register is a read-only register providing information on the status of the alarm functions and the comparator outputs. Bit Name Function 15 LTMPALM Latched temperature alarm bit; if low, this bit indicates that an alarm event has occurred. 14 Unlatched alarm bit; if low, these bit indicates that an alarm event is still TMPALM present. 13 Latched open-sense alarm bit; if low, indicates that an alarm event has LOSALM occurred. 12 Unlatched open-sense alarm bit; if low, indicates that an alarm event is still OSALM present. 11 LDUTALM Latched DUTGND Kelvin sense alarm; if low, indicates that an alarm event has occurred. 10 Unlatched DUTGND Kelvin sense alarm; if low, indicates that an alarm event is still DUTALM present. 9 Latched clamp alarm; if low, indicates that an alarm event has occurred. LCLALM 8 Unlatched clamp alarm; if low, indicates that an alarm event is still present. CLALM 7 LGRDALM Latched guard alarm; if low, indicates that an alarm event has occurred. 6 Unlatched guard alarm; if low, indicates that an alarm event is still present. GRDALM 5 CPOL Comparator output low condition as per the comparator output pin. 4 CPOH Comparator output high condition as per the comparator output pin. 3:0 Unused Must be zeros. This register is a read-only register providing information on the status of the alarm functions and the comparator outputs. Reading this register also automatically clears any latched alarm pins or bits. Bit Name Function 15 LTMPALM Latched temperature alarm bit; if low, this bit indicates that an alarm event has occurred. 14 Unlatched alarm bit; if low, these bit indicates that an alarm event is still TMPALM present. 13 Latched open-sense alarm bit; if low, indicates that an alarm event has LOSALM occurred. 12 Unlatched open-sense alarm bit; if low, indicates that an alarm event is still OSALM present. 11 LDUTALM Latched DUTGND Kelvin sense alarm; if low, indicates that an alarm event has occurred. 10 Unlatched DUTGND Kelvin sense alarm; if low, indicates that an alarm event is still DUTALM present. 9 Latched clamp alarm; if low, indicates that an alarm event has occurred. LCLALM 8 Unlatched clamp alarm; if low, indicates that an alarm event is still present. CLALM 7 LGRDALM Latched guard alarm; if low, indicates that an alarm event has occurred. 6 Unlatched guard alarm; if low, indicates that an alarm event is still present. GRDALM 5 CPOL Comparator output low condition as per the comparator output pin. 4 CPOH Comparator output high condition as per the comparator output pin. 3:0 Unused Must be zeros. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. D15 to D0. Reserved. Rev. D | Page 56 of 68 Data Sheet AD5560 READBACK MODE DAC READBACK The AD5560 allows data readback via the serial interface from every register directly accessible to the serial interface, which is all registers except the DAC register (x2 calibrated register). To read back contents of a register, it is necessary to write a 1 to the R/W bit, address the appropriate register, and fill the data bits with all zeros. The DAC x1, DAC m, and DAC c registers are available to read back via the serial interface. Access to the calibrated x2 register is not available. After the write command has been written, data from the selected register is loaded to the internal shift register and is available on the SDO pin during the next SPI operation. Address 0x43 and Address 0x44 are the only registers that are read only. The read function gives the user details of the alarm status and the comparator output result. Alarm flags on latched alarm pins (Pin 1, Pin 2, Pin 3) and bits are cleared after a read command of Register 0x44 (alarm status and clear alarm register (see Table 25)). SCLK frequency for readback does not operate at the full speed of the SPI interface. See the Timing Characteristics section for further details. POWER-ON DEFAULT During power-on, the power-on state machine resets all internal registers to their default values, and BUSY goes low. A rising edge on BUSY indicates that the power-on event is complete and that the interface is enabled. The RESET pin has no function in the power-on event. During power-on, all DAC x1 registers corresponding to 0 V are cleared; the calibration register default corresponds to m at full scale and to c at zero scale. The default conditions of the DPS and the system control registers are as shown in the relevant tables (see Table 17 through Table 26). During a RESET function, all registers are reset to the power-on default. Rev. D | Page 57 of 68 AD5560 Data Sheet Table 26. AD5560 Truth Table of Switches 1 Reg System Control Register DPS Register 1 Bit Name Gain0, Gain1 Bit SW1 X SW2 X SW3 X SW4 X SW7 X SW13 X SW14 X SW15 X SW5 X SW6 X SW8 X SW9 X SW11 X SW16 X FINGND 0 B X X X X X X X X X X X X X 1 A X X X X X X X X X X X X X CPO X X X X X X X X X X X X X X PD 2, 3 X X X X X X X X X X X X X On 04 15 000 X X X c a X X X X X X On X X On X X Off X X Off X X Off X X X X X X X X X X X X X X X X X X 001 X X X On On Off Off Off X X X X X X 010 X X X On On Off Off Off X X X X X X 011 X X X On On Off Off Off X X X X X X 100 X X X On On Off Off Off X X X X X X 101 X X X Off Off Off On On X X X X X X 110 X X X Off Off On Off On X X X X X X 00 X X X X X X X X X X X X X X 01 X X X X X X X X X X X X X X 10 X X a X X X X X X X X X X X 11 X X b X X X X X X X X X X X 000 X X X X X X X X X X X X X Off 001 X X X X X X X X X X X X X On 010 X X X X X X X X X X X X X On 011 X X X X X X X X X X X X X On 100 X X X X X X X X X X X X X On 101 X X X X X X X X X X X X X On 110 X X X X X X X X X X X X X On 111 X X X X X X X X X X X X X On SW-INH2 I2, I1, I0 CMP1, CMP0 ME3, ME2, ME1, ME0 DPS Register 2 SF0 Slave, GANGIMODE 0 X X X X X X X X X X Off Off X X 1 X X X X X X X X X X On On X X 00 6 b a X X X X X X a Off X X X X 01 7 b a X X X X X X b Off X X X X 8 c c X X X X X X Off On X X X X 11 9 0 c X b X X X X X X X X X X X X X Off X On X X X X X X Off X X 1 X 10 INT10K Hardware Pins 1 2 3 4 5 X X X X X X X X X X X X On HW_INH2 X c X X X X X X X X X X X X CLEN X X X X X X X X X X X X X X X = don’t care; the switch is unaffected by the particular bit condition. Active low. Power-down mode; used for low power consumption. Force amplifier outputs tristate, low leakage mode; feedback made around amplifier. FV mode. Master: MASTER_OUT = internally connects to active EXTFORCE1/EXTFORCE2/25 mA output. Master: MASTER_OUT = master MI. 8 Slave FV: EXTFORCE1/EXTFORCE2/25 mA connected internally to close the FVAMP loop. 9 Slave FI. 6 7 Rev. D | Page 58 of 68 Data Sheet AD5560 USING THE HCAVDDx AND HCAVSSx SUPPLIES internal pull-up resistors between the supplies (see Figure 59). Using diodes here allows a more flexible use of supplies and can minimize the amount of supply switching required. In the example, the AVDD and AVSS supplies can support the high voltage needs, whereas the HCAVDDx and HCAVSSx supplies support the low voltage, higher current ranges. Diode selection should take into account the current carrying requirements. Supply selection for HCAVDDx and HCAVSSx supplies must allow for this extra voltage drop. The first set of power supplies, AVDD and AVSS, provide power to the DAC levels and associated circuitry. They also supply the force amplifier stage for the low current ranges (ranges using internal sense resistors up to 25 mA maximum). The second set of power supplies, HCAVSS1 and HCAVDD1, are intended to be used to minimize power consumption in the AD5560 device for the EXTFORCE1 range (up to ±1.2 A). Similarly, the HCAVSS2 and HCAVDD2 supplies are used for the EXTFORCE2 range (up to ±500 mA). These supplies must be less than or equal to the AVDD and AVSS supplies. When driving high currents at low voltages, power can be greatly minimized by ensuring that the supplies are at the lowest voltages. POWER SUPPLY SEQUENCING When the supplies are connected to the AD5560, it is important that the AGND and DGND pins be connected to the relevant ground plane before the positive or negative supplies are applied. In most applications, this is not an issue because the ground pins for the power supplies are connected to the ground pins of the AD5560 via ground planes. The AVDD and AVSS supplies must be applied to the device either before or at the same time as the HCAVDDx and HCAVSSx supplies, as indicated in Table 3. There are no known supply sequences surrounding the DVCC supply, although it is recommended that it be applied as indicated by the absolute maximum ratings (see Table 3). Therefore, HCAVSSx and HCAVDDx can be switched externally to different power rails as required by the set voltage range. However, the design of the high current output stage means that these supplies always have to be at a higher voltage than the forced voltage, irrespective of the current range being used. Therefore, depending on the level of supply switching, external diodes may be required in series with each of the HCAVDDx and HCAVSSx supplies, as shown in Figure 59. There are DVCC = 3V/5V 10µF 10µF 10µF 10µF + + + + 10µF HCAV DD2 = +9V HCAV DD1 = +6V + 10µF HCAV SS2 = –5V HCAV SS1 = –5V AVDD = +28V + AVSS = –5V + 0.1µF 100kΩ 33kΩ 0.1µF 0.1µF 0.1µF + + + + 0.1µF + 0.1µF + 0.1µF 100kΩ 33kΩ 3. MIDCURRENT RANGE 500mA RANGE ALLOW ±0.5V FOR EXT RSENSE EXTFORCE2 DUT RANGE 0V TO +6V 2. HIGHEST CURRENT RANGE OUTPUT RANGE –0.2V TO +6.5V 1200mA RANGE 1. LOW CURRENT, HIGH VOLTAGE ALLOW ±0.5V FOR EXT RSENSE EXTFORCE1 DUT RANGE –2V TO +3V OUTPUT RANGE –2.5V TO +3.5V INTERNAL RANGE SELECT (5µA, 25µA, 250µA, 2.5mA, 25mA) AD5560 Figure 59. Example of Using the Extra Supply Rails Within the AD5560 to Achieve Multiple Voltage/Current Ranges Rev. D | Page 59 of 68 FORCE DUT RANGE 0V TO +25V 07779-012 INTERNAL RSENSE ±0.5V AT FULL CURRENT OUTPUT RANGE 0V TO +25V AD5560 Data Sheet five feedforward capacitor input pins, all capacitor inputs may be used only if the user intends to drive large variations of DUT load capacitances. If the DUT load capacitance is known and doesn’t change for all combinations of voltage ranges and test conditions, then it is possible only one set of CCx and CFx is required. REQUIRED EXTERNAL COMPONENTS The minimum required external components are shown in the block diagram in Figure 60. Decoupling is very dependent on the type of supplies used, the board layout, and the noise in the system. It is possible that less decoupling may be required as a result. Although there are four compensation input pins and HCAV DD1 + 10µF 0.1µF 0.1µF 0.1µF + + + 0.1µF + + + DVCC 0.1µF + AVDD 0.1µF + + AVSS 10µF + + 0.1µF 10µF HCAV DD2 REF DVCC 0.1µF 10µF + SHARED REFERENCE 10µF 10µF DVCC OR OTHER DIGITAL SUPPLY HCAV SS2 HCAV SS1 AVDD + AVSS CC0 CC1 CC2 CC3 VREF RPULLUP EXTFORCE1 EXTFORCE2 CLALM KELALM CF0 TMPALM CF1 CF2 DVCC OR OTHER DIGITAL SUPPLY CF3 CF4 RPULLUP RESET FORCE SENSE EXTMEASHI1 EXTMEASHI2 RSENSE 1 EXTMEASIL RSENSE 2 VREF ADC ADC DRIVER MEASOUT DUT DUTGND 07779-013 SHARED ADC Figure 60. External Components Required for Use with the DPS Table 27. References Suggested for Use with the AD5560 1 Part No. ADR431 ADR435 ADR441 ADR445 1 Voltage (V) 2.5 5 2.5 5 Initial Accuracy % ±0.04 ±0.04 ±0.04 ±0.04 Ref Out Tempco (ppm/°C max) A/B Grade 10/3 10/3 10/3 10/3 Ref Output Current (mA) 30 30 10 10 Supply Voltage Range (V) 4.5 to 18 7 to 18 3 to 18 5.5 to 18 Subset of the possible references suitable for use with the AD5560. See www.analog.com/references for more options. Rev. D | Page 60 of 68 Package MSOP, SOIC MSOP, SOIC MSOP, SOIC MSOP, SOIC Data Sheet AD5560 POWER SUPPLY DECOUPLING In any circuit where accuracy is important, careful consideration of the power supply and ground return layout helps to ensure the rated performance. The printed circuit board on which the AD5560 is mounted should be designed so that the analog and digital sections are separated and confined to certain areas of the board. If the AD5560 is in a system where multiple devices require an AGND-to-DGND connection, the connection should be made at one point only. The star ground point should be established as close as possible to the device. The DGND connection in the AD5560 should be treated as AGND and returned to the AGND plane. For more detail on decoupling for mixed signal applications, refer to Analog Devices Tutorial MT 031. For supplies with multiple pins (AVSS, AVDD, DVCC), it is recommended to tie these pins together and to decouple each supply once. The AD5560 should have ample supply decoupling of 10 µF in parallel with 0.1 µF on each supply located as close to the part as possible, ideally right up against the device. The 10 µF capacitors are the tantalum bead type. The 0.1 µF capacitor should have low effective series resistance (ESR) and effective series inductance (ESL), such as the common ceramic capacitors that provide a low impedance path to ground at high frequencies to handle transient currents due to internal logic switching. Digital lines running under the device should be avoided because these couple noise onto the device. The analog ground plane should be allowed to run under the AD5560 to avoid noise coupling. The power supply lines of the AD5560 should use as large a trace as possible to provide low impedance paths and reduce the effects of glitches on the power supply line. Fast switching digital signals should be shielded with digital ground to avoid radiating noise to other parts of the board and should never be run near the reference inputs. It is essential to minimize noise on all VREF lines. Avoid crossover of digital and analog signals. Traces on opposite sides of the board should run at right angles to each other. This reduces the effects of feedthrough throughout the board. As is the case for all thin packages, care must be taken to avoid flexing the package and to avoid a point load on the surface of this package during the assembly process. Also note that the exposed paddle of the AD5560 is internally connected to the negative supply AVSS. Rev. D | Page 61 of 68 AD5560 Data Sheet APPLICATIONS INFORMATION THERMAL CONSIDERATIONS Table 28. Thermal Resistance for TQFP_EP1 Cooling No Heat Sink Heat Sink7 Cold Plate8 Airflow (LFPM) 0 200 500 0 200 500 N/A θJA2 39 37.2 35.7 12.2 11.1 9.5 N/A θJC (Uniform)3 θJC (Local)4 Ideal TIM6 θJC (Local) w/TIM6 1.0 2.8 4.91 1.0 2.8 4.91 θJCP w/TIM5 N/A N/A 7.5 Unit °C/W °C/W °C/W °C/W °C/W °C/W °C/W 1 All numbers are simulated and assume a JEDEC 4-layer test board. θJA is the thermal resistance from hottest junction to ambient air. 3 θJC (Uniform) is the thermal resistance from junction to the package top, assuming total power is uniformly distributed. 4 θJC (Local) is the thermal resistance from junction to the center of package top, assuming total power = 8.5 W (1 W uniformly distributed, 7.5 W in power stages—local heating). 5 θJCP is the thermal resistance from hottest junction to infinite cold plate with consideration of thermal interface material (TIM). 6 Ideal TIM is assuming top of package in perfect contact with an infinite cold plate. w/TIM is assuming TIM is 0.5 mm thick, with thermal conductivity of 2.56 W/m/k. 7 Heat sink with a rated performance of θCA ~5.3°C/W under forced convection, gives ~TJ = 111°C at 500 LFM. Thermal performance of the package depends on the heat sink and environmental conditions. 8 Attached infinite cold plate should be ≤26°C to maintain TJ < 90°C, given total power = 8.5 W. Thermal performance of the package depends on the heat sink and environmental conditions. 9 To estimate junction temperature, the following equations can be used: TJ = Tamb + θJA × Power TJ = Tcold plate + θJCP × Power TJ = Ttop + θJC × Power 2 Table 29. Thermal Resistance for Flip Chip BGA1 Cooling No Heat Sink Heat Sink8 Cold Plate9 Airflow (LFPM) 0 200 500 0 200 500 N/A 2 JA θ 40.8 38.1 36 18 11.8 9 N/A θJC (Local)4 Ideal TIM6 θJC (Local) w/TIM6 0.05 1.6 4.6 0.05 1.6 4.6 θ 3 JC (Uniform) θJCP5 w/TIM N/A N/A 1 6.5 Unit °C/W °C/W °C/W °C/W °C/W °C/W °C/W All numbers are simulated and assume a JEDEC 4-layer test board. θJA is the thermal resistance from hottest junction to ambient air. θJC (Uniform) is the thermal resistance from junction to the package top, assuming total power is uniformly distributed. 4 θJC (Local) is the thermal resistance from junction to the center of package top, assuming total power = 8.5 W (1 W uniformly distributed, 7.5 W in power stages—local heating). 5 θJCP is the thermal resistance from hottest junction to infinite cold plate with consideration of thermal interface material (TIM). 6 Ideal TIM is assuming top of package in perfect contact with an infinite cold plate. w/TIM is assuming TIM is 0.4 mm thick, with thermal conductivity of 3.57 W/m/k. 7 Heat sink with a rated performance of θCA ~4.9°C/W under forced convection, gives ~TJ = 112°C at 500 LFM. Thermal performance of the package depends on the heat sink and environmental conditions. 8 Attached infinite cold plate should be ≤30°C to maintain TJ < 90°C, given total power = 8.5 W. Thermal performance of the package depends on the heat sink and environmental conditions. 9 To estimate junction temperature, the following equations can be used: TJ = Tamb + θJA × Power TJ = Tcold plate + θJCP × Power TJ = Ttop + θJC × Power 2 3 Rev. D | Page 62 of 68 Data Sheet AD5560 TEMPERATURE CONTOUR MAP ON THE TOP OF THE PACKAGE BGA Package Due to localized heating, temperature at the top surface of the package has steep gradient. Thus, the θJC value is highly dependent on where the case temperature is measured. Figure 61 shows the top of the die temperature contour map for the TQFP_EP. Due to localized heating, temperature at the top surface of the package has steep gradient. Thus, the θJC value is highly dependent on where the case temperature is measured. Figure 62 shows the top of the die temperature contour map for the flip chip BGA. 07779-064 TQFP_EP Package 07779-065 Figure 61. Temperature Contour Map for 64-Lead TQFP_EP Figure 62. Temperature Contour Map for the Flip Chip BGA Rev. D | Page 63 of 68 AD5560 Data Sheet OUTLINE DIMENSIONS 1.20 MAX 0.75 0.60 0.45 12.20 12.00 SQ 11.80 0.675 0.872 5.95 BSC 64 49 1 1.00 REF 49 48 64 1 48 SEATING PLANE EXPOSED PAD 5.95 BSC 10.20 10.00 SQ 9.80 7.85 BSC TOP VIEW (PINS DOWN) 0.15 0.05 0.08 COPLANARITY BOTTOM VIEW 16 0.20 0.09 33 17 7° 3.5° 0° VIEW A 32 16 17 32 7.85 BSC 0.27 0.22 0.17 0.50 BSC LEAD PITCH FOR PROPER CONNECTION OF THE EXPOSED PAD, REFER TO THE PIN CONFIGURATION AND FUNCTION DESCRIPTIONS SECTION OF THIS DATA SHEET. VIEW A (PINS UP) 33 10-19-2011-C 1.05 1.00 0.95 ROTATED 90° CCW COMPLIANT TO JEDEC STANDARDS MS-026-ACD-HU Figure 63. 64-Lead Thin Quad Flat Package, Exposed Pad [TQFP_EP] (SV-64-3) Dimensions shown in millimeters 8.10 8.00 SQ 7.90 5.720 REF A1 BALL CORNER 0.40 REF A1 BALL CORNER (DIE OFFSET) 9 8 7 6 5 4 3 2 1 A B C 6.865 REF 6.40 BSC SQ D E F G 0.80 BSC H J 0.80 REF *1.20 1.08 1.00 BOTTOM VIEW DETAIL A DETAIL A 0.36 REF 0.39 0.34 0.29 SEATING PLANE 0.50 0.45 0.40 BALL DIAMETER *COMPLIANT TO JEDEC STANDARDS MO-225 WITH EXCEPTION TO PACKAGE HEIGHT. Figure 64. 72-Ball Chip Scale Package Ball Grid Array [CSP_BGA] (BC-72-2) Dimensions shown in millimeters Rev. D | Page 64 of 68 0.81 0.76 0.71 COPLANARITY 0.12 04-19-2012-B TOP VIEW Data Sheet AD5560 ORDERING GUIDE Model 1 AD5560JSVUZ AD5560JSVUZ-REEL AD5560JBCZ AD5560JBCZ-REEL EVAL-AD5560EBUZ 1 2 Temperature Range 2 TJ = 25°C to +90oC TJ = 25°C to +90oC TJ = 25°C to +90oC TJ = 25°C to +90oC Package Description 64-Lead Thin Quad Flat Pack with Exposed Pad (TQFP_EP) 64-Lead Thin Quad Flat Pack with Exposed Pad (TQFP_EP) 72-Ball Chip Scale Package Ball Grid Array (CSP-BGA) 72-Ball Chip Scale Package Ball Grid Array (CSP-BGA) Evaluation Kit Z = RoHS Compliant Part. TJ = junction temperature. Rev. D | Page 65 of 68 Package Option SV-64-3 SV-64-3 BC-72-2 BC-72-2 AD5560 Data Sheet NOTES Rev. D | Page 66 of 68 Data Sheet AD5560 NOTES Rev. D | Page 67 of 68 AD5560 Data Sheet NOTES ©2008-2012 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. D07779-0-8/12(D) Rev. D | Page 68 of 68