INFINEON TLE4998C3

Data Sheet, Rev 1.0, December 2008
TLE4998C3
TLE4998C4
Programmable Linear Hall Sensor
Sensors
N e v e r
s t o p
t h i n k i n g .
Edition 2008-12
Published by Infineon Technologies AG,
Am Campeon 1-12,
85579 Neubiberg, Germany
© Infineon Technologies AG 2008.
All Rights Reserved.
Attention please!
The information herein is given to describe certain components and shall not be considered as a guarantee of
characteristics.
Terms of delivery and rights to technical change reserved.
We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding
circuits, descriptions and charts stated herein.
Information
For further information on technology, delivery terms and conditions and prices please contact your nearest
Infineon Technologies Office (www.infineon.com).
Warnings
Due to technical requirements components may contain dangerous substances. For information on the types in
question please contact your nearest Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or systems with the express written
approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure
of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support
devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain
and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may
be endangered.
Revision History:
2008-12
Previous Version:
Preliminary Data Sheet Rev 0.9
Page
Rev 1.0
Subjects (major changes since last revision)
We Listen to Your Comments
Any information within this document that you feel is wrong, unclear or missing at all?
Your feedback will help us to continuously improve the quality of this document.
Please send your proposal (including a reference to this document) to:
[email protected]
Template: mc_a5_ds_tmplt.fm / 4 / 2004-09-15
1
1.1
1.2
1.3
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Target Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
2.1
2.2
2.3
2.4
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Principle of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Transfer Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3
Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4
Operating Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5
Electrical, Thermal, and Magnetic Parameters . . . . . . . . . . . . . . . . . . . 14
Calculation of the Junction Temperature . . . . . . . . . . . . . . . . . . . . . . 16
Magnetic Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6
6.1
6.2
6.3
6.4
6.5
Signal Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Magnetic Field Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Temperature Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Magnetic Field Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gain Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Offset Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DSP Input Low-Pass Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clamping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
7.1
7.2
Error Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Voltages Outside the Operating Range . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
EEPROM Error Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
8
8.1
Temperature Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Parameter Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
9
9.1
9.2
9.3
9.4
Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Calibration Data Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Programming Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Data Transfer Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Programming of Sensors with Common Supply Lines . . . . . . . . . . . . . . .
10
Application Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
11
PG-SSO-3-10 Package Outlines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
12
PG-SSO-4-1 Package Outlines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
13
SPC Output Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Data Sheet
4
6
6
7
7
18
18
18
19
20
20
21
23
28
29
30
30
30
Rev 1.0, 2008-12
13.1
13.2
13.3
13.4
13.5
13.6
13.7
Basic SPC Protocol Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unit Time Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Master Pulse Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Synchronous Transmission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Synchronous Transmission Including Range Selection . . . . . . . . . . . . . . .
Synchronous Mode with ID Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Checksum Nibble Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Data Sheet
5
34
36
37
39
39
40
43
Rev 1.0, 2008-12
Programmable Linear Hall Sensor
TLE4998C3
TLE4998C4
1
Overview
1.1
Features
• SPC (Short PWM Code) protocol with
enhanced interface features based on SENT (Single
Edge Nibble Transmission,defined by SAE J2716)
• 20-bit Digital Signal Processing (DSP)
• Digital temperature compensation
• 16-bit overall resolution
• Operates within automotive temperature range
• Low drift of output signal over temperature and lifetime
• Programmable parameters stored in EEPROM with
single-bit error correction:
– SPC protocol modes: synchronous transmission,
dynamic range selection, ID selection mode
– SPC unit time
– Magnetic range and sensitivity (gain), polarity of the
output slope
– Offset
– Bandwidth
– Clamping levels
– Customer temperature compensation coefficients
– Memory lock
• Re-programmable until memory lock
• Supply voltage 4.5 - 5.5 V (4.1 - 16 V in extended range)
• Operation between -200 mT and +200 mT within three ranges
• Reverse-polarity and overvoltage protection for all pins
• Output short-circuit protection
• On-board diagnostics (overvoltage, EEPROM error, start up)
• Output of internal magnetic field values and temperature
• Programming and operation of multiple sensors with common power supply
• Two-point calibration of magnetic transfer function without iteration steps
• High immunity against mechanical stress, EMC, ESD
Type
Marking
Ordering Code
Package
TLE4998C3
4998C3
SP000476468
PG-SSO-3-10
TLE4998C4
4998C4
SP000440972
PG-SSO-4-1
Data Sheet
6
Rev 1.0, 2008-12
TLE4998C
Overview
1.2
Target Applications
• Robust replacement of potentiometers
– No mechanical abrasion
– Resistant to humidity, temperature, pollution and vibration
• Linear and angular position sensing in automotive applications such as pedal position,
suspension control, throttle position, headlight levelling, and steering torque sensing
• Sensing of high current for battery management, motor control, and electronic fuses
1.3
Pin Configuration
Figure 1 and Figure 2 show the location of the Hall element in the chip and the distance
between Hall probe and the surface of the package.
0.38 ±0.05
2.03 ±0.1
1.625 ±0.1
Center of
Hall Probe
Branded Side
Hall-Probe
1
2
3
AEP03717
Figure 1
Hall Cell Location and Pin Configuration of PG-SSO-3-10 package
Table 1
TLE4998C3 Pin Definitions and Functions
Pin No.
Symbol
Function
1
VDD
Supply voltage / programming interface
2
GND
Ground
3
OUT
Output / programming interface
Data Sheet
7
Rev 1.0, 2008-12
TLE4998C
Overview
B
2.67
d
0.2 B
Center of
sensitive area
1.53
A
2
3
Hall-Probe
4
0.2 A
1
Branded Side
d : Distance chip to branded side of IC
PG-SSO-4-1: 0.3 ±0.08 mm
AEP03654
Figure 2
Hall Cell Location and Pin Configuration of PG-SSO-4-1 package
Table 2
TLE4998C4 Pin Definitions and Functions
Pin No.
Symbol
Function
1
TST
Test pin (connection to GND is recommended)
2
VDD
Supply voltage / programming interface
3
GND
Ground
4
OUT
Output / programming interface
Data Sheet
8
Rev 1.0, 2008-12
TLE4998C
General
2
General
2.1
Block Diagram
Figure 3 shows a simplified block diagram.
VDD
Supply
Bias
*)
EEPROM
spinning
HALL
Interface
TST
A
D
OUT
DSP
Temp.
Sense
SPC
A
D
GND
ROM
Figure 3
2.2
*) TLE4998 C4 only
Block diagramm
Functional Description
The linear Hall IC TLE4998C has been designed specifically to meet the requirements
of highly accurate angle and position detection as well as for current measurement
applications. The sensor provides a digital SPC (Short PWM Code) signal, based on the
standardized SENT (Single Edge Nibble Transmission, SAE J2716) protocol. The SPC
protocol allows transmissions initiated by the ECU. Two further operation modes are
available:
• “range selection” for dynamical switching of the measurement range during operation
• “ID selection” to build a bus system with up to 4 ICs on a single output line and a
common supply, which can be individually accessed by the ECU.
Each transmission sequence contains an adjustable number of nibbles representing the
magnetic field, the temperature value and a status information of the sensor. The
interface is further described in Chapter 13. The output stage is an open-drain driver
Data Sheet
9
Rev 1.0, 2008-12
TLE4998C
General
pulling the output pin to low only. Therefore, the high level needs to be obtained by an
external pull-up resistor. This output type has the advantage that the receiver may use
an even lower supply voltage (e.g. 3.3 V). In this case the pull-up resistor must be
connected to the given receiver supply.
The IC is produced in BiCMOS technology with high voltage capability, and it also has
reverse-polarity protection.
Digital signal processing using a 16-bit DSP architecture together with digital
temperature compensation guarantee excellent long-time stability compared to analog
compensation methods.
While the overall resolution is 16 bits, some internal stages work with resolutions up to
20 bits.
2.3
Principle of Operation
• A magnetic flux is measured by a Hall-effect cell
• The output signal from the Hall-effect cell is converted from analog to digital
• The chopped Hall-effect cell and continuous-time A/D conversion ensure a very low
and stable magnetic offset
• A programmable low-pass filter to reduce noise
• The temperature is measured and A/D converted, too
• Temperature compensation is done digitally using a second-order function
• Digital processing of output value is based on zero field and sensitivity value
• The output value range can be clamped by digital limiters
• The final output value is represented by the data nibbles of the SPC protocol
Data Sheet
10
Rev 1.0, 2008-12
TLE4998C
General
2.4
Transfer Functions
The examples in Figure 4 show how different magnetic field ranges can be mapped to
the desired output value ranges.
• Polarity Mode:
– Bipolar: Magnetic fields can be measured in both orientations. The limit points
do not necessarily have to be symmetrical around the zero field point
– Unipolar: Only north- or south-oriented magnetic fields are measured
• Inversion: The gain can be set to both positive and negative values
OUT12 /
OUT16
B (mT)
50
4095 /
100
65535
0
0
-50
OUT12 /
OUT16
B (mT)
4095 /
65535
0
0
-100
Example 1:
- Bipolar
Figure 4
Data Sheet
B (mT)
OUT12 /
OUT16
200
4095 /
65535
0
0
-200
Example 2:
- Unipolar
- Big offset
Example 3:
- Bipolar
- Inverted (neg. gain)
Examples of Operation
11
Rev 1.0, 2008-12
TLE4998C
Maximum Ratings
3
Maximum Ratings
Table 3
Absolute Maximum Ratings
Parameter
Symbol
Limit Values
min.
Storage temperature
TST
- 40
Unit
Notes
max.
150
°C
1)
Junction temperature
TJ
- 40
170
°C
Voltage on VDD pin with
respect to ground
VDD
-18
18
V
Supply current
@ overvoltage VDD max.
IDDov
-
15
mA
Reverse supply current
@ VDD min.
IDDrev
-1
0
mA
Voltage on output pin with VOUT
respect to ground
-13)
184)
V
Magnetic field
BMAX
-
unlimited
T
ESD protection
VESD
-
4.0
kV
2)
According HBM
JESD22-A114-B 5)
1)
For limited time of 96 h. Depends on customer temperature lifetime cycles. Please ask for support by Infineon
2)
Higher voltage stress than absolute maximum rating, e.g. 150% in latch-up tests is not applicable. In such
cases, Rseries ≥100 Ω for current limitation is required
3)
IDD can exceed 10 mA when the voltage on OUT is pulled below -1 V (-5 V at room temperature)
4)
VDD = 5 V, open drain permanent low, for max. 10 minutes
5)
100 pF and 1.5 kΩ
Note: Stresses above those listed under “Absolute Maximum Ratings” may cause
permanent damage to the device. This is a stress rating only and functional
operation of the device at these or any other conditions above those indicated in
the operational sections of this specification is not implied.
Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Data Sheet
12
Rev 1.0, 2008-12
TLE4998C
Operating Range
4
Operating Range
The following operating conditions must not be exceeded in order to ensure correct
operation of the TLE4998C. All parameters specified in the following sections refer to
these operating conditions, unless otherwise indicated.
Table 4
Operating Range
Parameter
Supply voltage
Symbol Limit Values
VDD
min.
max.
4.5
5.5
1)
2)
Unit
V
4.1
16
V
Vpull-up
-
18
V
RL
1
-
kΩ
Output current3)
IOUT
0
5
mA
Load capacitance3)
CL
1
8
nF
Junction temperature
TJ
- 40
125
1504)
°C
Output pull-up voltage3)
Load
resistance3)
Notes
Extended range
For 5000 h
For 1000 h not additive
1)
For reduced output accuracy
2)
For supply voltages > 12 V, a series resistance Rseries ≥ 100 Ω is recommended
3)
Required output protocol characteristics depend on these parameters, RL must be according to max. output
current
4)
For reduced magnetic accuracy; extended limits are taken for characteristics
Note: Keeping signal levels within the limits specified in this table ensures operation
without overload conditions.
Data Sheet
13
Rev 1.0, 2008-12
TLE4998C
Electrical, Thermal, and Magnetic Parameters
5
Electrical, Thermal, and Magnetic Parameters
Table 5
Electrical Characteristics
Parameter
Symbol
Limit Values
Unit Notes
min. typ. max.
Unit time 3µs1)
SPC transmission time
tSPC
-
-
1
ms
Supply current
IDD
3
6
8
mA
Output current @ OUT
shorted to supply lines
IOUTsh
-
95
-
mA
Thermal resistance
TLE4998C3
RthJA
-
219 -
K/W Junction to air
RthJC
-
47
K/W Junction to case
Thermal resistance
TLE4998C4
RthJA
-
240 -
K/W Junction to air
RthJC
-
41
-
K/W Junction to case
Power-on time2)
tPon
-
0.7
15
2
20
ms
Power-on reset level
VDDpon
-
3.6
4
V
Output impedance
ZOUT
20
40
70
kΩ
3)
Output fall time
tfall
2
-
4
µs
VOUT 4.5 V to 0.5 V 4)
Output rise time
trise
-
20
-
µs
VOUT 0.5 V to 4.5 V
Output low saturation
voltage
VOUTsat
-
Output noise (rms)
OUTnoise -
-
VOUT = 5 V, max. 10
minutes
≤ ± 5% target out value
≤ ± 1% target out value
4)5)
0.3
0.2
0.6
0.4
V
IOUTsink = 5 mA
IOUTsink = 2.2 mA
1
2.5
LSB12 6)
1)
Transmission time depends on the data values being sent and on int. RC oscillator frequ. variation of +/- 20%.
2)
Response time to set up output data at power on when a constant field is applied. The first value given has a
± 5% error, the second value has a ± 1% error. Measured with 640-Hz low-pass filter
3)
VDD = 5V, VOUT=2.6V, open drain high state
4)
For VDD = 5 V, RL = 2.2 kΩ, CL = 4.7 nF, at room temperature, not considering condensator tolerance or
influence of external circuitry
Data Sheet
14
Rev 1.0, 2008-12
TLE4998C
Electrical, Thermal, and Magnetic Parameters
5)
Depends on external RL and CL
VOUT
*)
t HIGH
tlow
VDD
90% VDD
10% VDD
VOUTsat
*)
tfall
6)
RL to VDD assumed
trise
t
Range 100 mT, Gain 2.23, internal LP filter 244 Hz, B = 0 mT, T = 25 °C
Data Sheet
15
Rev 1.0, 2008-12
TLE4998C
Electrical, Thermal, and Magnetic Parameters
Calculation of the Junction Temperature
The internal power dissipation PTOT of the sensor increases the chip junction
temperature above the ambient temperature.
The power multiplied by the total thermal resistance RthJA (Junction to Ambient) added
to TA leads to the final junction temperature. RthJA is the sum of the addition of the two
components, Junction to Case and Case to Ambient.
RthJA = RthJC + RthCA
TJ = TA + ∆T
∆T = RthJA x PTOT = RthJA x ( VDD x IDD + VOUT x IOUT )
IDD , IOUT > 0, if direction is into IC
Example (assuming no load on Vout and TLE4998C4 type):
– VDD = 5 V
– IDD = 8 mA
– ∆T = 240 [K/W] x (5 [V] x 0.008 [A] + 0 [VA] ) = 9.6 K
For moulded sensors, the calculation with RthJC is more adequate.
Magnetic Parameters
Table 6
Magnetic Characteristics
Parameter
Symbol Limit Values
Unit
Notes
min.
typ.
max.
S1)
± 8.2
-
± 245 LSB12/ Programmable2)
mT
Temperature
TC
coefficient of sensitivity
-150
0
150
Magnetic field range
MFR
± 50
± 1004) ± 200 mT
Programmable 5)
Integral nonlinearity
INL
- 0.1
-
0.1
%MFR
6)8)
Magnetic offset
BOS
- 400
0
400
µT
7)8)
Magnetic offset drift
∆BOS
-5
-
5
µT / °C Error band8)
Magnetic hysteresis
BHYS
0
-
10
µT
Sensitivity
ppm/
°C
1)
Defined as ∆OUT / ∆B
2)
Programmable in steps of 0.024%
3)
For any 1st and 2nd order polynomial, coefficient within definition in Chapter 8.
Data Sheet
16
3)
See Figure 5
9)
Rev 1.0, 2008-12
TLE4998C
Electrical, Thermal, and Magnetic Parameters
4)
This range is also used for temperature and offset pre-calibration of the IC
5)
Depending on offset and gain settings, the output may already be saturated at lower fields
6)
Gain setup is 1.0
7)
In operating temperature range and over lifetime
8)
Measured at ± 100 mT range
9)
Measured in 100 mT range, Gain = 1, room temperature
∆S ~
S(T)/S0-1
max. pos.
TC-error
TCmax = ∆S/∆T
∆S0
0
Tmin
Tmax
T0
Tj
max. neg.
TC-error
TCmin = ∆S/∆T
Figure 5
Data Sheet
Drift of Temperature Coefficient
17
Rev 1.0, 2008-12
TLE4998C
Signal Processing
6
Signal Processing
The signal flow diagram in Figure 6 shows the signal path and data-processing
algorithm.
Range
Gain
LP
Limiter
(Clamp)
Hall
Sensor
Temperature
Sensor
A
D
X
D
+
Protocol
Generation
out
Offset
TC 2
X
X
A
X
1
+
TC 1
-T0
Stored in
EEPROM
Memory
+
X
Temperature
Compensation
Figure 6
Signal Processing Flow
Magnetic Field Path
• The analog output signal of the chopped Hall-effect cell is converted to a digital signal
in the continuous-time A/D converter. The range of the chopped A/D converter can be
set in several steps either by EEPROM settings or dynamically by the master in the
dynamic range mode (see Table 7). This gives a suitable level for the A/D converter
• After the A/D conversion, a digital low-pass filter reduces the bandwidth (Table 11)
• A multiplier amplifies the value depending on the gain (see Table 9) and temperature
compensation settings
• The offset value is added (see Table 10)
• A limiter reduces the resulting signal to 16 bits (see Chapter 13) and feeds the
Protocol Generation stage
Temperature Compensation
(Details are listed in Chapter 8)
• The output signal of the temperature cell is also A/D converted
Data Sheet
18
Rev 1.0, 2008-12
TLE4998C
Signal Processing
• The temperature is normalized by subtraction of the reference temperature T0 value
(zero point of the quadratic function)
• The linear path is multiplied with the TC1 value
• In the quadratic path, the temperature difference to T0 is squared and multiplied with
the TC2 value
• Both path outputs are added together and multiplied with the Gain value from the
EEPROM
6.1
Magnetic Field Ranges
The working range of the magnetic field defines the input range of the A/D converter. It
is always symmetrical around the zero field point. Any two points in the magnetic field
range can be selected to be the end points of the output value. The output value is
represented within the range between the two points.
In the case of fields higher than the range values, the output signal may be distorted. In
case of synchronous mode and ID selection mode the range must be set accordingly
(R=0/1/3) before the calibration of offset and gain.
Table 7
Range Setting
Range
Range in mT1)
Parameter R
Low
± 50
3
Mid
± 100
12)
High
± 200
0
1)
Ranges do not have a guaranteed absolute accuracy. The temperature pre-calibration is performed in the mid
range (100 mT)
2)
Setting R = 2 is not used, internally changed to R = 1
Table 8
Parameter
Range
Symbol Limit Values
min.
Register size
Data Sheet
R
Unit
Notes
max.
2
19
bit
Rev 1.0, 2008-12
TLE4998C
Signal Processing
6.2
Gain Setting
The overall sensitivity is defined by the range and the gain setting. The output of the ADC
is multiplied with the Gain value.
Table 9
Gain
Parameter
Symbol Limit Values
min.
Register size
Gain range
- 4.0
Gain
Gain quantization steps ∆Gain
Notes
bit
Unsigned integer value
-
1)2)
ppm
Corresponds to 1/4096
max.
15
G
Unit
3.9998
244.14
1)
For Gain values between - 0.5 and + 0.5, the numerical accuracy decreases
To obtain a flatter output curve, it is advisable to select a higher range setting
2)
A gain value of +1.0 corresponds to typical 32 LSB12/mT sensitivity (100 mT range, not guaranteed). It is
crucial to do a final calibration of each IC within the application using the Gain/OUTOS value
The Gain value can be calculated by
:
( G – 16384 )
Gain = -----------------------------4096
6.3
Offset Setting
The offset value corresponds to an output value with zero field at the sensor.
Table 10
Offset
Parameter
Symbol
Limit Values
min.
Register size
Offset range
Offset quantization
steps
1)
Unit
Notes
bit
Unsigned integer value
LSB12
1)
max.
15
OS
OUTOS -16384 16383
∆OUTOS
1
LSB12
Infineon pre-calibrates the samples at zero field to 50% output value (100 mT range), but does not guarantee
the value. Therefore it is crucial to do a final calibration of each IC within the application
The offset value can be calculated by:
OUT OS = OS – 16384
Data Sheet
20
Rev 1.0, 2008-12
TLE4998C
Signal Processing
6.4
DSP Input Low-Pass Filter
A digital low-pass filter is placed between the Hall A/D converter and the DSP, and can
be used to reduce the noise level. The low-pass filter has a constant DC amplification of
0 dB (Gain of 1), which means that its setting has no influence on the internal Hall ADC
value.
The bandwidth can be set to any of 8 values.
Table 11
Low Pass Filter Setting
Cutoff frequency in Hz (-3dB point)1)
Note: Parameter LP
0
80
1
240
2
440
3
640
4
860
5
1100
6
1390
7
off
1)
As this is a digital filter running with an RC-based oscillator, the cutoff frequency may vary within ±20%
Table 12
Low-Pass Filter
Parameter
Symbol Limit Values
min.
Register size
Corner frequency
variation
LP
∆f
- 20
Unit
Notes
max.
3
bit
+ 20
%
Note: In range 7 (filter off), the output noise increases.
Data Sheet
21
Rev 1.0, 2008-12
TLE4998C
Signal Processing
Figure 7 shows the filter characteristics as a magnitude plot (the highest setting is
marked). The “off” position would be a flat 0 dB line. The update rate after the low-pass
filter is 16 kHz.
0
Magnitude (dB)
-1
-2
-3
-4
-5
-6
101
2
10
10
3
Frequency (Hz)
Figure 7
Data Sheet
DSP Input Filter (Magnitude Plot)
22
Rev 1.0, 2008-12
TLE4998C
Signal Processing
6.5
Clamping
The clamping function is useful for separating the output range into an operating range
and error ranges. If the magnetic field is exceeding the selected measurement range, the
output value OUT is limited to the clamping values.
Table 13
Clamping
Parameter
Symbol
Limit Values
min.
Register size
Clamping value low
Clamping value high
Clamping quantization
steps
CL,CH
OUTCL
OUTCH
∆OUTCx
Unit
Notes
bit
(0...63)
max.
2x6
0
65535
LSB16
1)
0
65535
LSB16
1) 2)
LSB16
3)
1024
1)
For CL = 0 and CH = 63 the clamping function is disabled
2)
OUTCL < OUTCH mandatory
3)
Quantization starts for CL at 0 LSB16 and for CH at 65535 LSB16
The clamping values are calculated by:
Clamping value low (deactivated if CL=0):
OUT CL = CL ⋅ 64 ⋅ 16
Clamping value high (deactivated if CH=63):
OUT CH = ( CH + 1 ) ⋅ 64 ⋅ 16 – 1
Data Sheet
23
Rev 1.0, 2008-12
TLE4998C
Signal Processing
Figure 8 shows an example in which the magnetic field range between Bmin and Bmax
is mapped to output values between 10240 LSB16 and 55295 LSB16.
OUT (LSB16)
65535
Error range
OUTCH
55295
Operating range
OUTCL
10240
Error range
0
Bmax
Bmin
B (mT)
Figure 8
Clamping Example
Note: The clamping high value must be above the low value. If OUTCL is set to a higher
value than OUTCH, the OUTCH value is dominating. This would lead to a constant
output value independent of the magnetic field strength.
Data Sheet
24
Rev 1.0, 2008-12
TLE4998C
Error Detection
7
Error Detection
Different error cases can be detected by the On-Board Diagnostics (OBD) and reported
to the microcontroller in the status nibble (see Chapter 13).
7.1
Voltages Outside the Operating Range
The output signals an error condition if VDD crosses the overvoltage threshold level.
Table 14
Overvoltage
Parameter
Symbol
Limit Values
min.
Overvoltage threshold
1)
VDDov
typ.
16.65 17.5
Unit
Notes
max.
18.35 V
1)
Overvoltage bit activated in status nibble, output stays in “off” state (high ohmic)
7.2
EEPROM Error Correction
The parity method is able to correct a single bit in the EEPROM line. One other single bit
error in another EEPROM line can also be detected, but not corrected. In an
uncorrectable EEPROM failure, the open drain stage is disabled and kept in the off state
permanently (high ohmic/sensor defect).
Data Sheet
25
Rev 1.0, 2008-12
TLE4998C
Temperature Compensation
8
Temperature Compensation
The magnetic field strength of a magnet depends on the temperature. This material
constant is specific for the different magnet types. Therefore, the TLE4998C offers a
second-order temperature compensation polynomial, by which the Hall signal output is
multiplied in the DSP. There are three parameters for the compensation:
• Reference temperature T0
• A linear part (1st order) TC1
• A quadratic part (2nd order) TC2
The following formula describes the sensitivity dependent on the temperature in relation
to the sensitivity at the reference temperature T0:
S TC ( T ) = 1 + TC 1 × ( T – T 0 ) + TC 2 × ( T – T0 )
2
For more information, please refer to the signal processing flow in Figure 6.
The full temperature compensation of the complete system is done in two steps:
1. Pre-calibration in the Infineon final test
The parameters TC1, TC2, T0 are set to maximally flat temperature characteristics
with respect to the Hall probe and internal analog processing parts.
2. Overall system calibration
The typical coefficients TC1, TC2, T0 of the magnetic circuitry are programmed. This
can be done deterministically, as the algorithm of the DSP is fully reproducible. The
final setting of the TC1, TC2, T0 values depend on the pre-calibrated values.
Table 15
Temperature Compensation
Parameter
Register size TC1
1st order coefficient TC1
Quantization steps of TC1
Register size TC2
2nd order coefficient TC2
Quantization steps of TC2
Reference temp.
Quantization steps of T0
Symbol Limit Values Unit
Notes
min.
max.
TL
TC1
qTC1
-
9
TQ
TC2
qTC2
T0
qT0
-
8
bit
Unsigned integer values
-4
4
ppm/ °C²
2)
bit
Unsigned integer values
-1000 2500
ppm/ °C
1)
15.26
ppm/ °C
0.119
- 48
64
1
ppm/ °C²
°C
°C
3)
1)
Full adjustable range: -2441 to +5355 ppm/°C, can be only used after confirmation by Infineon
2)
Full adjustable range: -15 to +15 ppm/°C², can be only used after confirmation by Infineon
3)
Handled by algorithm only (see Application Note)
Data Sheet
26
Rev 1.0, 2008-12
TLE4998C
Temperature Compensation
8.1
Parameter Calculation
The parameters TC1 and TC2 may be calculated by:
TL – 160
TC 1 = ---------------------- × 1000000
65536
TQ – 128
TC 2 = ----------------------- × 1000000
8388608
Now the digital output for a given field BIN at a specific temperature can be calculated by:
 B IN

- × S TC × S TCHall × S 0 × 4096 + OUT OS
OUT = 2 ⋅  ----------- B FSR

BFSR is the full-range magnetic field. It is dependent on the range setting (e.g 100 mT).
S0 is the nominal sensitivity of the Hall probe times the Gain factor set in the EEPROM.
STC is the temperature-dependent sensitivity factor calculated by the DSP.
STCHall is the temperature behavior of the Hall probe.
The pre-calibration at Infineon is performed such that the following condition is met:
S TC ( T J – T 0 ) × S TCHall ( T J ) ≈ 1
Within the application, an additional factor BIN(T) / BIN(T0) is given due to the magnetic
system. STC then needs to be modified to STCnew so that the following condition is
satisfied:
B IN ( T )
-------------------× S TCnew ( T ) × S TCHall ( T ) ≈ S TC ( T ) × S TCHall ( T ) ≈ 1
B IN ( T 0 )
Therefore, the new sensitivity parameters STCnew can be calculated from the precalibrated setup STC using the relationship:
B IN ( T )
-------------------× S TCnew ( T ) ≈ S TC ( T )
B IN ( T 0 )
Data Sheet
27
Rev 1.0, 2008-12
TLE4998C
Calibration
9
Calibration
For the calibration of the sensor, a special hardware interface to a PC is required. All
calibration and setting bits can be temporarily written into a Random Access Memory
(RAM). This allows the EEPROM to remain untouched during the entire calibration
process, since the number of the EEPROM programming cycles is limited. Therefore,
this temporary setup (using the RAM only) does not stress the EEPROM.
The digital signal processing is completely deterministic. This allows a two-point
calibration to be performed in one step without iterations. After measuring the Hall output
signal for the two end points, the signal processing parameters Gain and Offset can be
calculated.
Table 16
Calibration Characteristics
Parameter
Symbol
1)
Unit
Notes
min.
max.
10
30
°C
∆OUTCAL1 -8
8
LSB12
Position 1
∆OUTCAL2 -8
8
LSB12
Position 2
Ambient temperature at TCAL
calibration
2 point Calibration
accuracy1)
Limit Values
Corresponds to ± 0.2% accuracy in each position
Data Sheet
28
Rev 1.0, 2008-12
TLE4998C
Calibration
9.1
Calibration Data Memory
When the MEMLOCK bits are programmed (two redundant bits), the memory content is
frozen and may no longer be changed. Furthermore, the programming interface is locked
out and the chip remains in application mode only, preventing accidental programming
due to environmental influences.
Row Parity Bits
Column Parity Bits
User-Calibration Bits
Pre-Calibration Bits
Figure 9
EEPROM Map
A matrix parity architecture allows automatic correction of any single-bit error. Each row
is protected by a row parity bit. The sum of bits set (including this bit) must be an odd
number (ODD PARITY). Each column is additionally protected by a column parity bit.
Each bit in the even positions (0, 2, etc.) of all lines must sum up to an even number
(EVEN PARITY), and each bit in the odd positions (1, 3, etc.) must have an odd sum
(ODD PARITY). The parity column must have an even sum (EVEN PARITY).
This system of different parity calculations also protects against many block errors (such
as erasing a full line or even the whole EEPROM).
When modifying the application bits (such as Gain, Offset, TC, etc.), the parity bits must
be updated. As for the column bits, the pre-calibration area must be read out and
considered for correct parity generation as well.
Note: A specific programming algorithm must be followed to ensure data retention.
A detailed separate programming specification is available on request.
Data Sheet
29
Rev 1.0, 2008-12
TLE4998C
Calibration
Table 17
Programming Characteristics
Parameter
Symbol Limit Values
Number of EEPROM
programming cycles
NPRG
Ambient temperature at TPRG
programming
Unit
Notes
min.
max.
-
10
Cycles1) Programming allowed
only at start of lifetime
10
30
°C
100
-
ms
For complete memory 2)
Programming time
tPRG
Calibration memory
-
150
Bit
All active EEPROM bits
Error Correction
-
26
Bit
All parity EEPROM bits
1)
1 cycle is the simultaneous change of ≥ 1 bit
2)
Depending on clock frequency at VDD, write pulse 10 ms ±1%, erase pulse 80 ms ±1%
9.2
Programming Interface
The VDD pin and the OUT pin are used as a two-wire interface to transmit the EEPROM
data to and from the sensor.
This allows:
• Communication with high data reliability
• The bus-type connection of several sensors and separate programming via the OUT
pin
9.3
Data Transfer Protocol
The data transfer protocol is described in a separate document (User Programming
Description), available on request.
9.4
Programming of Sensors with Common Supply Lines
In many automotive applications, two sensors are used to measure the same parameter.
This redundancy makes it possible to continue operation in an emergency mode. If both
sensors use the same power supply lines, they can be programmed together in parallel.
Data Sheet
30
Rev 1.0, 2008-12
TLE4998C
Application Circuit
10
Application Circuit
Figure 10 shows the connection of multiple sensors to a microcontroller.
Sensor
Module
Voltage Supply
Sensor
Voltage Supply
µC
ECU
Module
µC
VDD
V dd
V DD
47nF
TLE
4998
2k2
OUT1
50
out
CCin1
GND
1 nF
4.7nF
GND
VGND
CCin2
2k2
V DD
47nF
TLE out
4998
OUT2
50
GND
optional
1 nF
4.7nF
Figure 10
Application Circuit
Note: For calibration and programming, the interface has to be connected directly to the
OUT pin.
The application circuit shown should be regarded as an example only. It will need to be
adapted to meet the requirements of other specific applications. Further information is
given in Chapter 13.
Data Sheet
31
Rev 1.0, 2008-12
TLE4998C
PG-SSO-3-10 Package Outlines
11
PG-SSO-3-10 Package Outlines
45˚
4.06 ±0.05
2 A
1.5 ±0.05
B
1.5
1)
1 ±0.2
(0.25)
4.05 ±0.05
0.1 MAX.
5˚
0.5 ±0.1
0.42 ±0.05
1
2
0.82 ±0.05
3x
0.36 ±0.05
0.5 B
3
2 x 1.27 = 2.54
12.7 ±1
1-1
19 ±0.5
6 ±0.5
18 ±0.5
C
33 MAX.
9 -0.50
+0.75
(10)
(Useable
Length)
2 C
A
Adhesive
Tape
Tape
4 ±0.3
6.35 ±0.4
12.7 ±0.3
Total tolerance at 19 pitches ±1
0.25 -0.15
0.39 ±0.1
1) No solder function area
Molded body dimensions do not unclude plastic or metal protrusion of 0.15 max per side
P-PG-SSO-3-10-PO V02
Figure 11
Data Sheet
PG-SSO-3-10 (Plastic Green Single Small Outline Package)
32
Rev 1.0, 2008-12
TLE4998C
PG-SSO-4-1 Package Outlines
PG-SSO-4-1 Package Outlines
5.34 ±0.05
0.2
2 A
0.25 ±0.05
1 MAX.1)
(0.25)
7˚
1.9 MAX.
1-0.1
7˚
1 x 45˚ ±1˚
3.38 ±0.06
0.1 MAX.
5.16 ±0.08
3.71±0.08
12
4x
0.5
0.2 +0.1
0.6 MAX.
0.4 ±0.05
1
2
3
4
1.27
3 x 1.27 = 3.81
18 ±0.5
6 ±0.5
1-1
38 MAX.
9 +0.75
-0.5
(14.8)
(Useable Length)
23.8 ±0.5
12.7 ±1
Adhesive
Tape
A
Tape
6.35 ±0.4
4 ±0.3
0.25 -0.15
0.39 ±0.1
12.7 ±0.3
Total tolerance at 10 pitches ±1
1) No solder function area
GPO05357
Figure 12
PG-SSO-4-1 (Plastic Green Single Small Outline Package)
Data Sheet
33
Rev 1.0, 2008-12
TLE4998C
SPC Output Definition
13
SPC Output Definition
The sensor supports a SPC (Short PWM Code) protocol, which enhances the
standardized SENT protocol (Single Edge Nibble Transmission) defined by SAE J2716.
SPC enables the use of enhanced protocol functionality due to the ability to select
between “synchronous”, “range selection” and “ID selection” protocol mode. The
following tables give an overview of relevant registers to chose the appropriate SPC
mode.
Table 18
SPC Mode Registers
Parameter
Symbol Limit Values
min.
Unit
max.
Protocol register
P
2
bit
ID register
ID
2
bit
1)
Notes
1)
The ID register is only actively used in ID selection mode.
Table 19
SPC Mode Selection
Mode
Parameter PMSB
Parameter PLSB Explanation
Synchronous
0
No effect
Section 13.4
Dynamic range selection
1
0
Section 13.5
ID selection
1
1
Section 13.6
13.1
Basic SPC Protocol Definition
As in SENT, the time between two consecutive falling edges defines the value of a four
bit nibble, thus representing numbers between 0 and 15. The transmission time therefore
depends on the transmitted data values. The single edge is defined by a 3 unit time (UT)
low pulse on the output, followed by the high time defined in the protocol (nominal values,
may vary by tolerance of internal RC oscillator, not including analog delay of the open
drain output and influence by external circuitry, unit time programming see
Section 13.2). All values are multiples of a unit time frame concept. A transfer consists
of the following parts, depicted in Figure 13:
•
•
•
•
A trigger pulse by the master, which initiates the data transmission
A synchronization period of 56 UT (in parallel, a new sample is calculated)
A status nibble of 12-27 UT
Between 3 and 6 data nibbles of 12-27 UT each (number is programmable, see
Table 21), representing the Hall value and temperature information
• A CRC nibble of 12-27 UT
• An end pulse to terminate the SPC transmission.
Data Sheet
34
Rev 1.0, 2008-12
TLE4998C
SPC Output Definition
Master
Trigger
Pulse
Line idle
Sync
frame
Status
Nibble
Data
Nibble 1
Data
Nibble 2
Data
Nibble 3
OUT
Data
Nibble 3
Data
Nibble 4*
Data
Nibble 5*
Data
Nibble 6*
CRC
Nibble
End Pulse
Available for
next sample
* Data Nibbles 4 to 6 are optional (programmable )
Figure 13
SPC Frame
The CRC checksum includes the status nibble and the data nibbles and can be used to
check the validity of the decoded data. The sensor is available for the next sample 90µs
after the falling edge of the end pulse. The sampling time (when values are taken for
temperature compensation) is always defined as the beginning of the synchronization
period. During this period, the resulting data is always calculated from scratch.
The number of transmitted SPC nibbles is programmable to customize the amount of
information sent by the sensor. The frame contains a 16bit Hall value and an 8bit
temperature value in the full configuration.
Table 20
Frame Register
Parameter
Symbol Limit Values
min.
Frame register
Table 21
F
Unit
Notes
max.
2
bit
Frame Selection
Frame Type
Parameter F
Data Nibbles
16bit Hall, 8bit temperature
0
6 nibbles
16bit Hall
1
4 nibbles
12bit Hall, 8bit temperature
2
5 nibbles
12bit Hall
3
3 nibbles
The temperature is coded as an 8bit value. The value is transferred in unsigned integer
format and corresponds to the range between -55°C and +200°C, so a transferred value
Data Sheet
35
Rev 1.0, 2008-12
TLE4998C
SPC Output Definition
of 55 corresponds to 0°C. Table 22 shows the mapping between junction temperature
and the transmitted value in the SPC frame.
Table 22
Mapping of Temperature Value
Junction Temperature Typ. Decimal Value from Sensor Note
- 55°C
0
0°C
55
25°C
80
200°C
255
1)
Theoretical lower limit1)
Theoretical upper limit1)
Theoretical range of temperature values, not operating temperature range
The status nibble allows to check internal states and conditions of the sensor.
• Depending on the selected SPC mode, the first two bits of the status nibble contain
either the selected magnetic range or the ID of the sensor and allow therefore an easy
interpretation of the received data.
• The third bit is set to “1” for the first transmission after the sensor returns from an
overvoltage operation with disabled open drain stage to regular operation (see
Chapter 7.1).
• The fourth bit is switched to “1” for the first data package transferred after a reset. This
allows the detection of low-voltage situations or EMC problems of the sensor.
13.2
Unit Time Setup
The basic SPC protocol unit time granularity is defined as 3 µs. Every timing is a multiple
of this basic time unit. To achieve more flexibility, trimming of the unit time can be used
to:
• Allow a calibration trim within a timing error of less than 20% clock error (as given in
SAE standard)
• Allow a modification of the unit time for small speed adjustments
This enables a setup of different unit times, even if the internal RC oscillator varies by
±20%. Of course, timing values that are too low could clash with timing requirements of
Data Sheet
36
Rev 1.0, 2008-12
TLE4998C
SPC Output Definition
the application and should therefore be avoided, but in principle it is possible to adjust
the timer unit for a more precise protocol timing.
Table 23
Predivider Setting
Parameter
Symbol
Limit Values
min.
Register size
Prediv
Unit time
tUNIT
2.0
Unit
Notes
4
bit
Predivider1)
3.88
µs
ClkUNIT=8MHz2)
max.
1)
Prediv default is decimal = 8 for 3 µs nominal SPC unit time
2)
RC oscillator frequency variation +/- 20%
The nominal unit time is calculated by:
tUNIT = (Prediv + 16) / ClkUNIT
Clk UNIT = 8MHz ± 20%
13.3
Master Pulse Requirements
An SPC transmission is initiated by a Master pulse on the OUT pin. To detect a low level
on the OUT pin, the voltage must be below a threshold Vthf. The sensor detects that the
OUT line has been released as soon as Vthr is crossed. Figure 14 shows the timing
definitions for the master pulse. The master low time tmlow as well as the total trigger time
tmtr are individual for the different SPC modes and are given in the subsequent sections.
It is recommended to chose the typical master low time exactly between the minimum
and the maximum possible time: tmlow,typ = (tmlow,min + tmlow,max) / 2. Although the
allowed timing windows are larger for longer low times, the master should use a quarz
clock source to provide a high timing accuracy (approx. 1%). For improved robustness,
the master pulse can be adopted by the master once the effective unit time is known
through the sensor’s synchronisation period length. If the master low time exceeds the
maximum low time, the sensor does not respond and is available for a next triggering
Data Sheet
37
Rev 1.0, 2008-12
TLE4998C
SPC Output Definition
30µs after the master pulse crosses Vthr. tmd,tot is the delay between internal triggering
of the falling edge in the sensor and the triggering of the ECU.
Table 24
Master Pulse Parameters
Parameter
Symbol
Limit Values
min. typ.
max.
Falling edge threshold
Vthf
1.1
1.7
V
Rising edge threshold
Vthr
1.25 1.43 1.8
V
Total trigger time
tmtr
10.8 13
16.3
UT
Synchronous mode 1)2)
46.6 56
70
UT
Dyn. range mode 1)2)
75
90
113
UT
ID selection mode 1)2)
3.7
5.8
7.9
µs
3)
Master delay time
tmd,tot
1.3
Unit Notes
1)
UT = Programmed nominal SPC unit time
2)
Trigger time in the sensor is fixed to the number of unit times specified in the “typ.” column, but the effective
trigger time varies due to the sensor’s clock variation
3)
For VDD = 5 V, RL = 2.2 kΩ, CL = 4.7 nF, ECU trigger level Vth,ECU = 2V
tmtr
OUT
Vthf,max
Vthf,min
Vthr,max
ECU trigger
level
Vthr,min
tmd,tot
tmlow,min
t mlow,max
Figure 14
Data Sheet
SPC Master Pulse Timing
38
Rev 1.0, 2008-12
TLE4998C
SPC Output Definition
13.4
Synchronous Transmission
In the “synchronous” mode, the sensor (slave) starts to transfer a complete data frame
only after a low pulse is forced by the master on the OUT pin. This means that the data
line is bidirectional - an open drain output of the microcontroller (master) sends the
trigger pulse. The sensor then initiates a sync pulse and starts to calculate the new
output data value. After the synchronization period, the data follows in form of a standard
SENT frame, starting with the status, data and CRC nibbles. At the end, an end pulse
allows the CRC nibble decoding and indicates that the data line is idle again. The timing
diagram in Figure 13 visualizes a synchronous transmission.
Table 25
Master Pulse Timing Requirements for Synchronous Mode
Parameter
Symbol
Limit Values
min.
Master low time
1)
tmlow
1.5
typ.
2.75
Unit1) Notes
max.
4
UT
UT = Programmed nominal SPC unit time
CPU
Sensor
VDD
OUT
Capcom-Unit
Outpin (OD)
GND
Figure 15
13.5
Bidirectional Communication in Synchronous Mode
Synchronous Transmission Including Range Selection
The low time duration of the master can be used to select the magnetic range of the
sensor in SPC dynamic range selection mode.
Table 26
Master Pulse Timing Requirements for Dynamic Range Mode
Parameter
Symbol
Limit Values
min.
Master low time
1)
tmlow
typ.
Unit1) Notes
max.
1.5
3.25
5
UT
Range = 200mT (R=0)
9
12
15
UT
Range = 100mT (R=1)
24
31.5
39
UT
Range = 50mT (R=3)
UT = Programmed nominal SPC unit time
Data Sheet
39
Rev 1.0, 2008-12
TLE4998C
SPC Output Definition
The range information in the status bit can be used to determine whether the range has
been properly identified. Changing the range takes some time due to the settling time of
internal circuitry. The first sample after a range switch therefore still displays a value
sampled with the old range setting, and the second transmission after changing the
range displays the new range with reduced accuracy.
13.6
Synchronous Mode with ID Selection
This functionality is similar to the previous mode, but instead of switching the range of
one sensor, one of up to four sensors are selectable on a bus (bus mode, 1 master with
up to 4 slaves). This allows parallel connection of up to 4 sensors using only three lines
(VDD, GND, OUT), as illustrated in Figure 16.
CPU
Sensor 1
VDD
OUT
Capcom-Unit
Outpin (OD)
GND
Sensor 2
VDD
OUT
GND
Figure 16
Bidirectional Communication with ID Selection
In this mode, the sensor starts to transfer complete packages only after receiving a
master low pulse with an ID that is equivalent to the programmed value in its ID register.
The mapping between master low time and ID is given in Table 27. A proper addressing
requires the different sensors on a same bus to be programmed with the same nominal
Data Sheet
40
Rev 1.0, 2008-12
TLE4998C
SPC Output Definition
SPC unit time. Alternatively, the sensors can be trimmed using the predivider settings to
further reduce their relative unit time difference for more robustness.
Table 27
Master Pulse Timing Requirements for ID Selection Mode
Parameter
Symbol
Limit Values
min.
Master low time
1)
tmlow
typ.
Unit1) Notes
max.
9
10.5
12
UT
ID = 0
19
21
23
UT
ID = 1
35.5
38
40.5
UT
ID = 2
61.5
64.5
67.5
UT
ID = 3
UT = Programmed nominal SPC unit time
Data Sheet
41
Rev 1.0, 2008-12
TLE4998C
SPC Output Definition
Table 28
Content of a SPC Data Frame (5-8 Nibbles)
omitted if F[0] = 1*
omitted if F[1] = 1*
TRIGGER
SYNC
bits
STATUS
H1
H2
H3
H4
T1
T2
description
CRC
description
state
state
status information
10
RR/ID
startup condition in RR / of ID
01
RR/ID
overvoltage in RR / of ID
00
RR/ID
normal state in RR / of ID
CRC calculation
for all nibbles
seed value: 0101
polynomial: X4+X3 +X2+1
bits
description
11
+/- 50mT or ID #3
10
+/- 100mT or ID #2
01
+/- 100mT or ID #1
00
+/- 200mT or ID #0
bits
description1
description 2
decimal: OUT12
decimal: OUT16
( = H1* 256+H2*16 +H3 )
( = OUT12*16+H4 )
bits
description
T1
T2
decimal: TEMP8
65535 (FSR)
1111
1111
200 °C
4095
65534
1111
1110
199 °C
:
4095
:
1111
:
:
1111
0000
4095
65520
1111
0000
185 °C
1111
1110
1111
4094
65519
1110
1111
184 °C
1111
1110
1110
4094
65518
:
:
:
1111
1111
1110
:
4094
:
0101
0000
25 °C
1111
1111
1110
0000
4094
65504
0100
1111
24 °C
1111
1111
1101
1111
4093
65503
:
:
:
:
:
:
:
:
:
0011
0111
0°C
0000
0000
0010
0000
2
32
0011
0110
-1°C
0000
0000
0001
1111
1
31
:
:
:
0000
0000
0001
:
1
:
0000
0001
-54 °C
0000
0000
0001
0000
1
16
0000
0000
-55 °C
0000
0000
0000
1111
0
15
0000
0000
0000
1110
0
14
0000
0000
0000
:
0
:
0000
0000
0000
0001
0
1
0000
0000
0000
0000
0
0
H1
H2
H3
H4
1111
1111
1111
1111
4095 (FSR)
1111
1111
1111
1110
1111
1111
1111
1111
1111
1111
1111
* The number of nibbles is programmed
in the frame register F
Data Sheet
42
( = T1*16 + T2 )
Abbreviations:
TRIGGER – trigger nibble
SYNC – synchronization nibble
STATUS – status nibble
CRC – cyclic redundancy code nibble
FSR – full scale range
H1..4 – hall value
T1..2 – temperature value
OUT12 – 12 bit output value
OUT16 – 16 bit output value
TEMP8 – 8 bit temperature value
Rev 1.0, 2008-12
TLE4998C
SPC Output Definition
13.7
Checksum Nibble Details
The Checksum nibble is a 4-bit CRC of the data nibbles including the status nibble. The
CRC is calculated using a polynomial x4 +x3 + x2 + 1 with a seed value of 0101.
In the TLE4998C it is implemented as a series of XOR and shift operations as shown in
the following flowchart:
CRC calculation
Pre-initialization :
Nibble
next Nibble
VALUE
GENERATOR = 1101
xor
SEED = 0101 , use this
constant as old CRC
value at first call
SEED
<<1
VALUE
VALUExor
xorSEED
SEED
0
4x
xor only if MSB = 1
GENPOLY
Figure 17
CRC Calculation
A microcontroller implementation may use an XOR command plus a small 4-bit lookup
table to calculate the CRC for each nibble.
// Fast way for any µC with low memory and compute capabilities
char Data[8] = {…}; // contains the input data (status nibble , 6 data nibble , CRC)
// required variables and LUT
char CheckSum, i;
char CrcLookup[16] = {0, 13, 7, 10, 14, 3, 9, 4, 1, 12, 6, 11, 15, 2, 8, 5};
CheckSum= 5; // initialize checksum with seed "0101"
for (i=0; i<7; i++) {
CheckSum = CheckSum ^ Data[i];
CheckSum = CrcLookup[CheckSum];
}
; // finally check if Data [7] is equal to CheckSum
Figure 18
Data Sheet
Example Code for CRC Generation
43
Rev 1.0, 2008-12
w w w . i n f i n e o n . c o m
Published by Infineon Technologies AG