Filter specification
TFS 500
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
External Coil:
23
0
°C
dBm
415 Ω || -1 pF
415 Ω || -1 pF
33 nH
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 500 is the minimum of the pass band attenuation. This value is defined as the insertion loss
ae. The nominal frequency fN is fixed at 500,0 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating
temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
Insertion loss
(reference level)
ae
Nominal frequency
fN
PB
Passband
100
90
60
1
MHz
MHz
MHz
MHz
dB
max.
5,0
dB
500,0
MHz
0,1
MHz
2,0
dB
kHz
fN
dB
max.
dB
dB
dB
dB
min.
min.
min.
min.
40
38
40
40
dB
dB
dB
dB
-
max.
10
dBm
-
- 40 °C …+ 85°C
±
arel
Relative attenuation
+
390
1,3
Pass band variation
fN
fN
fN
fN
4,4
tolerance / limit
…
…
…
…
fN
fN
fN
fN
+
90
60
1
100
MHz
MHz
MHz
MHz
Input power level
Operating temperature range
OTR
-
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
48
42
47
42
TCf **
- 40 °C ... + 85°C
41
°C
- 0,036
ppm/K
2
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = TCf(ppm/K2) x (T - To)2 x fTo (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 500.doc
Version 1.3
VI TELEFILTER
28.04.2006
Filter specification
TFS 500
2/5
Filter characteristic
0
0
-0.5
-10
-1
-1.5
magnitude in dB
magnitude in dB
-20
-30
-40
-2
-2.5
-3
5
-3.5
-4
-50
-4.5
-60
496
497
498
499
500
501
frequency in MHz
502
503
504
505
-5
499.7
499.8
499.9
500
500.1
frequency in MHz
500.2
500.3
0
500.4
Construction and pin connection
(All dimensions in mm)
7
500
● U08
1
SQ 3,81 +0,2/-0,1
5
3
1
2
3
4
5
6
7
8
Input
Input RF Return
External Coil
Ground
Output
Output RF Return
Ground
Ground
Date code:
T
U
V
...
Year + week
2005
2006
2007
7
5
0,1
12
0%
0,6
%
d
3
1,78
2,54
1
1,2 Max.
Date code
1,78
50 Ω Test circuit
5
1
3
2, 4, 6, 7, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 500.doc
Version 1.3
VI TELEFILTER
28.04.2006
Filter specification
TFS 500
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 5,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 4,30 ± 0,1
Bo
: 4,30 ± 0,1
Ct
: 9,5 ± 0,1
t
P1
Date Code
Po
P2
W
G
Ct
Bo
F
G
E
Do
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 500.doc
Version 1.3
VI TELEFILTER
28.04.2006
Filter specification
TFS 500
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 500.doc
VI TELEFILTER
Version 1.3
Filter specification
28.04.2006
TFS 500
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
10.11.2005
1.1
- Add operating temperature range
- Add frequency inversion temperature
Channaa
21.11.2005
1.2
- Add typical values
- Add filter characteristic
- Add test circuit
- Add terminating impedances
Martens
23.02.2006
1.3
- Change from development specification to filter specification
- Change relative attenuation
Alawneh
28.04.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.