Filename: tfs 456s.doc Version 1.3 VI TELEFILTER 08.12.2006 Filter specification TFS 456S 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 537 Ω || -4,9 pF 532 Ω || -5,0 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 456S is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 456,0 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value ae = amin Insertion loss (reference level) fN - 2,3 + + 50,0 20,0 4,6 20,0 13,7 dB 456,0 MHz PB - fN ± 2,3 MHz 0,45 dB max. 0,80 1,0 dB arel Relative attenuation fN fN fN fN max. - p-p Pass band ripple dB fN Nominal frequency Passband 10,7 tolerance / limit MHz … fN + 2,3 MHz MHz MHz MHz MHz + + 20,0 4,6 20,0 50,0 MHz MHz MHz MHz dB max. 54 44 42 54 dB dB dB dB min. min. min. min. 50 40 40 50 dB dB dB dB Group delay ripple within PB 49 ns max. 200 ns Return loss within PB 20 dB min. 10 dB max. 15 dBm … … … … fN fN fN fN - Input power level Operating temperature range OTR Storage temperature range Frequency inversion temperature Temperature coefficient of frequency TCf ** 1,0 - - 45 °C ... + 85°C - - 45 °C ... + 85°C 51 °C -0,036 ppm/K 2 dB - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 456s.doc Version 1.3 VI TELEFILTER 08.12.2006 Filter specification TFS 456S 2/5 0 1.97 -0.6 1.82 -20 -1.2 1.67 -30 -1.8 1.52 -2.4 1.37 -40 -3 1.22 -3.6 1.07 -70 -4.2 0.92 -80 -4.8 0.77 -90 -5.4 0.62 -50 -60 -100 306.2 336.2 366.2 396.2 426.2 456.2 486.2 frequency in MHz 516.2 546.2 576.2 606.2 -6 452.2 453 453.8 454.6 455.4 456.2 457 frequency in MHz 457.8 458.6 459.4 delay in µs 0 -10 magnitude in dB magnitude in dB Filter characteristic 0.47 460.2 Construction and pin connection (All dimensions in mm) S 456S ● U49 Date code 1 2 3 4 5 6 7 8 9 10 Ground Ground Ground Output Output RF Return Ground Ground Ground Input Input RF Return Date code: U V W ... Year + week 2006 2007 2008 50 Ω Test circuit L1 9 10 4 SAW L2 5 C2 C1 1, 2, 3, 6, 7, 8 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 456s.doc Version 1.3 VI TELEFILTER 08.12.2006 Filter specification TFS 456S 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 7,50 ± 0,1 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 5,50 ± 0,1 Bo : 7,50 ± 0,1 Ct : 13,5 ± 0,1 P1 Date Code Po Do P2 W G Ct Bo F G E t Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 456s.doc Version 1.3 VI TELEFILTER 08.12.2006 Filter specification TFS 456S 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 456s.doc VI TELEFILTER Version 1.3 Filter specification 08.12.2006 TFS 456S 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 20.02.2006 1.1 - Operating temperature range extended - Input power level added Strehl 22.03.2006 1.2 - Change from development specification to filter specification - Add terminating impedance values - Add typical values - Add filter characteristics - Add matching circuit Alawneh 24.08.2006 1.3 - Change input power level Strehl 08.12.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.