VECTRON TFS456S

Filename: tfs 456s.doc
Version 1.3
VI TELEFILTER
08.12.2006
Filter specification
TFS 456S
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
537 Ω || -4,9 pF
532 Ω || -5,0 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 456S is the minimum of the pass band attenuation. This value is defined as the insertion
loss ae. The nominal frequency fN is fixed at 456,0 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole
operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
ae = amin
Insertion loss
(reference level)
fN
-
2,3
+
+
50,0
20,0
4,6
20,0
13,7
dB
456,0
MHz
PB
-
fN ± 2,3
MHz
0,45
dB
max.
0,80
1,0
dB
arel
Relative attenuation
fN
fN
fN
fN
max.
-
p-p
Pass band ripple
dB
fN
Nominal frequency
Passband
10,7
tolerance / limit
MHz … fN
+
2,3
MHz
MHz
MHz
MHz
MHz
+
+
20,0
4,6
20,0
50,0
MHz
MHz
MHz
MHz
dB
max.
54
44
42
54
dB
dB
dB
dB
min.
min.
min.
min.
50
40
40
50
dB
dB
dB
dB
Group delay ripple within PB
49
ns
max.
200
ns
Return loss within PB
20
dB
min.
10
dB
max.
15
dBm
…
…
…
…
fN
fN
fN
fN
-
Input power level
Operating temperature range
OTR
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
TCf **
1,0
-
- 45 °C ... + 85°C
-
- 45 °C ... + 85°C
51
°C
-0,036
ppm/K
2
dB
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 456s.doc
Version 1.3
VI TELEFILTER
08.12.2006
Filter specification
TFS 456S
2/5
0
1.97
-0.6
1.82
-20
-1.2
1.67
-30
-1.8
1.52
-2.4
1.37
-40
-3
1.22
-3.6
1.07
-70
-4.2
0.92
-80
-4.8
0.77
-90
-5.4
0.62
-50
-60
-100
306.2
336.2
366.2
396.2
426.2
456.2
486.2
frequency in MHz
516.2
546.2
576.2
606.2
-6
452.2
453
453.8
454.6
455.4 456.2
457
frequency in MHz
457.8
458.6
459.4
delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
0.47
460.2
Construction and pin connection
(All dimensions in mm)
S 456S
● U49
Date code
1
2
3
4
5
6
7
8
9
10
Ground
Ground
Ground
Output
Output RF Return
Ground
Ground
Ground
Input
Input RF Return
Date code:
U
V
W
...
Year + week
2006
2007
2008
50 Ω Test circuit
L1
9
10
4
SAW
L2
5
C2
C1
1, 2, 3, 6, 7, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 456s.doc
Version 1.3
VI TELEFILTER
08.12.2006
Filter specification
TFS 456S
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,50 ± 0,1
Bo
: 7,50 ± 0,1
Ct
: 13,5 ± 0,1
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 456s.doc
Version 1.3
VI TELEFILTER
08.12.2006
Filter specification
TFS 456S
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 456s.doc
VI TELEFILTER
Version 1.3
Filter specification
08.12.2006
TFS 456S
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
20.02.2006
1.1
- Operating temperature range extended
- Input power level added
Strehl
22.03.2006
1.2
- Change from development specification to filter specification
- Add terminating impedance values
- Add typical values
- Add filter characteristics
- Add matching circuit
Alawneh
24.08.2006
1.3
- Change input power level
Strehl
08.12.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.