MEANWELL RCP

RCP-MU
Power Control and Monitor System
Features :
1U low profile
19-inch rack mounting
Control and monitor up to 3 RCP-1000 units
Suitable for all kinds of RCP output (12V,24V,48V)
Digital meters for output voltage, output current, and internal temperature
on front panel
Potential meter for adjusting output voltage of RCP-1000 unit on front panel
Relay contacts and LED indicators for AC fail, DC fail, and over temperature
warning
Removable fixing accessory
3 years warranty
2
Description : RCP-MU is the monitoring and control unit used for the RCP-1000 series rack power. It can decode the I C signal sent by
RCP series and display through digital meters or relay contact signals. RCP-MU can also turn ON/OFF or trim the output
voltage of RCP-1000 remotely that make the basic control more easily.
SPECIFICATION
MODEL
INPUT
RCP-MU
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.35A/115VAC
30A/115VAC
MONITORING INPUTS
DIGITAL METER
OUTPUT
FUNCTION
CONTROL OUTPUT
2
I C signal ( AC OK, DC OK, and over temperature alarm signals for each RCP-1000 unit ), output voltage of the RCP-1U rack
Note.2 Display the DC output voltage, current, and internal temperature of each RCP-1000 unit
Remote ON/OFF and output voltage trimming for each RCP-1000 unit
Alarm for AC Fail, DC Fail, and Over Temperature ; rating : 30VDC, 1A
LED INDICATOR
AC Fail, DC Fail, Over Temperature
REMOTE ON/OFF CONTROL
The controlled RCP-1000 unit can be turned ON/OFF on the front panel for RCP-MU
VOLTAGE TRIM
Output voltage of the controlled RCP-1000 unit and be trimmed by 10% on the front panel of RCP-MU
WORKING TEMP.
-20 ~ +60
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
EMC EMISSION
NOTE
0.2A/230VAC
50A/230VAC
RELAY CONTACT
ENVIRONMENT
OTHERS
127 ~ 370VDC
20~90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Design refer to UL60950-1, TUV EN60950-1
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11
DIMENSION
440*68*44mm (L*W*H)
1.15Kg; 6pcs/8Kg/1.27CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Resolution and tolerance of the values shown on the digital meter depends on the controlled RCP series.
File Name:RCP-MU-SPEC 2011-08-19
RCP-MU
Power Control and Monitor System
Mechanical Specification
Case No. 701A
3
DC Fail
Tem p Alar
m
AC Fail
OFF
1
2
3
PSU
ON/O FF
VOL TS
AMP S
DC Fail
Tem p Alar
m
PSU1
2
AC Fail
TEM P
VOL TS
AMP S
DC Fail
Tem p Alar
m
PSU3
AC Fail
ON
1
PSU2
Your Reliab le Power
Partne r
PSU
Output Adjus
t
Unit:mm
TEM P
VOL TS
AMP S
TEM P
BACK
Model Select
Switch
AC Input Terminal Block
Communication
Connector
Output
Voltage Lock
Alarm Signals Terminal Block
Alarm Signals
w w w. m e a n w e l l . c o m
100 - 240VAC
N
L
Temp 3
Alarm
DC 3
Fail
AC 3
Fail
3
5
Temp 2
Alarm
DC 2
Fail
AC 2
Fail
9
11
Temp 1
Alarm
DC 1
Fail
AC 1
Fail
15
17
All alarm signals are potential free relays
1
2
4
6
7
8
10
12
13
14
16
18
2
Pin No.
1
2
3
13
14
25
Disable
1 2 3
3
AC Input Terminal Block
1
Enable
Supply Voltage: 100 - 240VAC 50/60Hz
0.35 - 0.2A
1
Communication
VOLTS
LOCK
MODEL
SELECT
Model : RCP-MU
1 2 3
Alarm Signals Pin No. Assignment
Assignment
FG
AC/N
AC/L
Pin No.
1,2
3,4
5,6
Assignment
Temp 3 Fail
DC 3 Fail
AC 3 Fail
Pin No.
7,8
9,10
11,12
Assignment
Temp 2 Fail
DC 2 Fail
AC 2 Fail
Pin No.
13,14
15,16
17,18
Assignment
Temp 1 Fail
DC 1 Fail
AC 1 Fail
Communication Connector Pin No. Assignment
Pin No.
1
2
3
4
5
Pin No.
Assignment
ON/OFF-A
AC-OK-A
DC-OK-A
V-TRIM-A
T-ALARM-A
Pin No.
Assignment
+5V-AUX
GND-AUX
ON/OFF-B
AC-OK-B
DC-OK-B
6
7
8
9
10
Assignment
V-TRIM-B
T-ALARM-B
NC
CS
ON/OFF-C
11
12
13
14
15
Pin No.
Pin No.
Assignment
AC-OK-C
DC-OK-C
V-TRIM-C
T-ALARM-C
+S
16
17
18
19
20
Assignment
-S
+V
SCL
SDA
-V
21
22
23
24
25
68
TOP
AMPS
ON
PSU
Output Adjust
1
2
3
PSU
ON/OFF
OFF
1
2
AC Fail
DC Fail
VOLTS
AMPS
Temp Alarm
TEMP
AC Fail
DC Fail
VOLTS
AMPS
Temp Alarm
TEMP
3
Remote Adjust Remote ON/OFF
Display of PSU1
Display of PSU2
TEMP
7.4
36.9
VOLTS
Temp Alarm
PSU3
DC Fail
PSU2
AC Fail
Partn er
Your Relia ble Power
10.2
PSU1
44
7.1
FRONT
Display of PSU3
440
466.1
483.6
File Name:RCP-MU-SPEC 2011-08-19
RCP-MU
Power Control and Monitor System
Block Diagram
The diagram below only shows one set of input / output signals. One RCP-MU can control and monitor up to 3 units of RCP-1000 power unit.
PSU ON/OFF
ON / OFF
Display
Voltage
Current
Temperature
LED Alarm
AC Fail
DC Fail
Temp Alarm
PSU
Output Adjust
+V
MCU
V- Trim
-V
AC Fail
Relay
Contact
SCA / SDL
DC Fail
Temp Alarm
12V
24V
48V
66V
Model
Select
Typical User Manual
RCP-1U Address dip switch setting
1. Monitoring Input
RCP-1U
ON
RCP-MU
Communication
CN500
OFF
1 2 3 4 5 6 7 8 9
Module A Module B Module C
2. Alarm Signal Relay Contact
Function
Description
AC Fail
When input AC fail, relay open, LED lights
DC Fail
When output DC fail, relay open, LED lights
Temp Alarm
When temperature exceed the limit of temperature, relay open, LED lights
3. Model Select Switch
To get better display resolution, the correct output voltage of RCP-1000 that is monitored should be chosen. The factory original setting is for 48V models.
ON
1 2 3
OFF
ON
ON
(24V)
(12V)
(48V)
1 2 3
OFF
1 2 3
OFF
ON
(66V)
1 2 3
OFF
(For special custom made
RCP-1000 models)
4. Output Voltage Lock
The output voltage adjustment for RCP-1000 units can be enabled or disabled for different application needs.
Enable
Voltage of power device can not be adjusted.
(a)
1 2 3
Disable
Enable
Voltage of power device can be adjusted independently by VRs.
(b)
1 2 3
Disable
File Name:RCP-MU-SPEC 2011-08-19