RCP-MU Power Control and Monitor System Features : 1U low profile 19-inch rack mounting Control and monitor up to 3 RCP-1000 units Suitable for all kinds of RCP output (12V,24V,48V) Digital meters for output voltage, output current, and internal temperature on front panel Potential meter for adjusting output voltage of RCP-1000 unit on front panel Relay contacts and LED indicators for AC fail, DC fail, and over temperature warning Removable fixing accessory 3 years warranty 2 Description : RCP-MU is the monitoring and control unit used for the RCP-1000 series rack power. It can decode the I C signal sent by RCP series and display through digital meters or relay contact signals. RCP-MU can also turn ON/OFF or trim the output voltage of RCP-1000 remotely that make the basic control more easily. SPECIFICATION MODEL INPUT RCP-MU VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.35A/115VAC 30A/115VAC MONITORING INPUTS DIGITAL METER OUTPUT FUNCTION ENVIRONMENT CONTROL OUTPUT 127 ~ 370VDC 0.2A/230VAC 50A/230VAC 2 I C signal ( AC OK, DC OK, and over temperature alarm signals for each RCP-1000 unit ), output voltage of the RCP-1U rack Note.2 Display the DC output voltage, current, and internal temperature of each RCP-1000 unit Remote ON/OFF and output voltage trimming for each RCP-1000 unit RELAY CONTACT Alarm for AC Fail, DC Fail, and Over Temperature ; rating : 30VDC, 1A LED INDICATOR AC Fail, DC Fail, Over Temperature REMOTE ON/OFF CONTROL The controlled RCP-1000 unit can be turned ON/OFF on the front panel for RCP-MU VOLTAGE TRIM Output voltage of the controlled RCP-1000 unit and be trimmed by 10% on the front panel of RCP-MU WORKING TEMP. -20 ~ +60 WORKING HUMIDITY STORAGE TEMP., HUMIDITY VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 20~90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes Design refer to UL60950-1, TUV EN60950-1 I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT OTHERS NOTE Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11 DIMENSION 440*68*44mm (L*W*H) 1.15Kg; 6pcs/8Kg/1.27CUFT PACKING / 70% RH 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Resolution and tolerance of the values shown on the digital meter depends on the controlled RCP series. File Name:RCP-MU-SPEC 2008-08-07 RCP-MU Power Control and Monitor System Mechanical Specification Case No. 701A 3 DC Fail Tem p Alar m AC Fail OFF 1 2 3 PSU ON/O FF VOL TS AMP S DC Fail Tem p Alar m PSU1 2 AC Fail TEM P VOL TS AMP S DC Fail Tem p Alar m PSU3 AC Fail ON 1 PSU2 Your Reliab le Power Partne r PSU Output Adjus t Unit:mm TEM P VOL TS AMP S TEM P BACK Model Select Switch AC Input Terminal Block Communication Connector Output Voltage Lock Alarm Signals Terminal Block Alarm Signals w w w. m e a n w e l l . c o m 100 - 240VAC N L Temp 3 Alarm DC 3 Fail AC 3 Fail 3 5 Temp 2 Alarm DC 2 Fail AC 2 Fail 9 11 Temp 1 Alarm DC 1 Fail AC 1 Fail 15 17 All alarm signals are potential free relays 1 2 4 6 7 8 10 12 13 14 16 18 2 Pin No. 1 2 3 13 14 25 Disable 1 2 3 3 AC Input Terminal Block 1 Enable Supply Voltage: 100 - 240VAC 50/60Hz 0.35 - 0.2A 1 Communication VOLTS LOCK MODEL SELECT Model : RCP-MU 1 2 3 Alarm Signals Pin No. Assignment Assignment FG AC/N AC/L Pin No. 1,2 3,4 5,6 Assignment Temp 3 Fail DC 3 Fail AC 3 Fail Pin No. 7,8 9,10 11,12 Assignment Temp 2 Fail DC 2 Fail AC 2 Fail Pin No. 13,14 15,16 17,18 Assignment Temp 1 Fail DC 1 Fail AC 1 Fail Communication Connector Pin No. Assignment Pin No. 1 2 3 4 5 Pin No. Assignment ON/OFF-A AC-OK-A DC-OK-A V-TRIM-A T-ALARM-A Pin No. Assignment +5V-AUX GND-AUX ON/OFF-B AC-OK-B DC-OK-B 6 7 8 9 10 Assignment V-TRIM-B T-ALARM-B NC CS ON/OFF-C 11 12 13 14 15 Pin No. Pin No. Assignment AC-OK-C DC-OK-C V-TRIM-C T-ALARM-C +S 16 17 18 19 20 Assignment -S +V SCL SDA -V 21 22 23 24 25 68 TOP AMPS ON PSU Output Adjust 1 2 3 PSU ON/OFF OFF 1 2 AC Fail DC Fail VOLTS AMPS Temp Alarm TEMP AC Fail DC Fail VOLTS AMPS Temp Alarm TEMP 3 Remote Adjust Remote ON/OFF Display of PSU1 Display of PSU2 TEMP 7.4 36.9 VOLTS Temp Alarm PSU3 DC Fail PSU2 AC Fail Partn er Your Relia ble Power 10.2 PSU1 44 7.1 FRONT Display of PSU3 440 466.1 483.6 File Name:RCP-MU-SPEC 2008-08-07 RCP-MU Power Control and Monitor System Block Diagram The diagram below only shows one set of input / output signals. One RCP-MU can control and monitor up to 3 units of RCP-1000 power unit. PSU ON/OFF ON / OFF Display Voltage Current Temperature LED Alarm AC Fail DC Fail Temp Alarm PSU Output Adjust +V MCU V- Trim -V AC Fail Relay Contact SCA / SDL DC Fail Temp Alarm 12V 24V 48V 66V Model Select Typical User Manual RCP-1U Address dip switch setting 1. Monitoring Input RCP-1U ON RCP-MU Communication CN500 OFF 1 2 3 4 5 6 7 8 9 Module A Module B Module C 2. Alarm Signal Relay Contact Function Description AC Fail When input AC fail, relay open, LED lights DC Fail When output DC fail, relay open, LED lights Temp Alarm When temperature exceed the limit of temperature, relay open, LED lights 3. Model Select Switch To get better display resolution, the correct output voltage of RCP-1000 that is monitored should be chosen. The factory original setting is for 48V models. ON 1 2 3 OFF ON ON (24V) (12V) (48V) 1 2 3 OFF 1 2 3 OFF ON (66V) 1 2 3 OFF (For special custom made RCP-1000 models) 4. Output Voltage Lock The output voltage adjustment for RCP-1000 units can be enabled or disabled for different application needs. Enable Voltage of power device can not be adjusted. (a) 1 2 3 Disable Enable Voltage of power device can be adjusted independently by VRs. (b) 1 2 3 Disable File Name:RCP-MU-SPEC 2008-08-07