MPD D128ER

D100ER Series
Low Cost, 1W SIP
Tightly Regulated
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
Parameter
Conditions
Min.
Typ.
Max.
5 VDC Input
4.75
5.0
5.25
12 VDC Input
11.4
12.0
12.6
24 VDC Input
22.8
24.0
25.2
• 1W Output Power
• Tightly Regulated
• Single & Dual Outputs
• Miniature SIP Case
• 1,000 VDC Isolation
Input Voltage Range
Input Filter
Units
VDC
Internal Capacitor
Reverse Polarity Input Current
0.3
A
Max.
Units
Output
• >3.5 MHour MTBF
Parameter
• 24 Standard Models
Output Voltage Accuracy
• Industry Standard Pin-Out
Output Voltage Balance
• LOWEST COST!!
Line Regulation
Load Regulation (Note 1)
Conditions
Min.
Typ.
±3.0
%
±1.0
%
For Vin Min to Max
±0.25
%
For Iout = 10% to 100%
±1.0
%
20
mV P - P
±0.03
%/ºC
Max.
Units
Dual Output , Balanced Loads
±0.1
Ripple & Noise (20 MHz) (Note 3)
10
Output Power Protection
120
%
Temperature Coefficient
Output Short Circuit
Momentary (1.0 Sec.)
General
Parameter
Conditions
Isolation Voltage
RoHS Compliant
Isolation Resistance
Isolation Capacitance
Min.
60 Seconds
1,000
500 VDC
1,000
100 kHz, 1V
Switching Frequency
Typ.
VDC
MΩ
60
pF
100
kHz
Environmental
Min.
Typ.
Max.
Operating Temperature Range
Parameter
Conditions
Ambient
-40
+25
+85
ºC
Operating Temperature Range
Case
-40
+90
ºC
-55
+125
ºC
95
%
Storage Temperature Range
Cooling
Humidity
Units
Free Air Convection
RH, Non-condensing
MicroPower Direct
Physical
292 Page Street
Suite D
Stoughton, MA 02072
USA
Case Size (Single Output)
0.77 x 0.24 x 0.40 Inches (19.6 x 6.0 x 10.2 mm)
Case Size (Dual Output)
1.08 x 0.37 x 0.47 Inches (27.5 x 9.5 x 12.0 mm)
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Reliability Specifications
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
Parameter
MTBF
0.07 Oz (2.1g)
Conditions
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
Typ.
Max.
3.5
Units
MHours
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Conditions
Min.
Typ.
Max.
5 VDC Input
-0.7
9.0
12 VDC Input
-0.7
18.0
24 VDC Input
-0.7
30.0
Units
VDC
1.5 mm From Case For 10 Sec
300
ºC
All Models
450
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
D101ER
D102ER
D103ER
D104ER
D105ER
D106ER
D107ER
D108ER
D111ER
D112ER
D113ER
D114ER
D115ER
D116ER
D117ER
D118ER
D121ER
D122ER
D123ER
D124ER
D125ER
D126ER
D127ER
D128ER
Input
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
5
4.75 - 5.25
294
30
5
4.75 - 5.25
286
30
5
4.75 - 5.25
282
30
5
4.75 - 5.25
278
30
5
4.75 - 5.25
290
30
5
4.75 - 5.25
286
30
5
4.75 - 5.25
278
30
5
4.75 - 5.25
278
30
12
11.4 - 12.6
121
15
12
11.4 - 12.6
117
15
12
11.4 - 12.6
116
15
12
11.4 - 12.6
116
15
12
11.4 - 12.6
119
15
12
11.4 - 12.6
116
15
12
11.4 - 12.6
114
15
12
11.4 - 12.6
114
15
24
22.8 - 25.2
59
8
24
22.8 - 25.2
58
8
24
22.8 - 25.2
57
8
24
22.8 - 25.2
57
8
24
22.8 - 25.2
58
8
24
22.8 - 25.2
58
8
24
22.8 - 25.2
57
8
24
22.8 - 25.2
57
8
Output
Voltage Current
Current
(VDC) (mA, Max) (mA, Min)
5.0
200.0
20.0
9.0
111.0
12.0
12.0
83.0
9.0
15.0
67.0
7.0
±5.0
±100.0
±10.0
±9.0
±56.0
±6.0
±12.0
±42.0
±5.0
±15.0
±33.0
±4.0
5.0
150.0
15.0
9.0
111.0
12.0
12.0
83.0
9.0
15.0
67.0
7.0
±5.0
±100.0
±10.0
±9.0
±56.0
±6.0
±12.0
±42.0
±5.0
±15.0
±33.0
±4.0
5.0
150.0
15.0
9.0
111.0
12.0
12.0
83.0
9.0
15.0
67.0
7.0
±5.0
±100.0
±10.0
±9.0
±56.0
±6.0
±12.0
±42.0
±5.0
±15.0
±33.0
±4.0
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. These units should not be operated with a load under 10% of full load.
Operation at no-load may cause damage to the unit.
3. These converters will operate without external components. However, when
measuring output ripple, it is recommended that an external ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units
and from each output to common for dual output units. An input capacitor
will enhace stability
Output Capacitor
over temperature and
Input
Vin
Vout
input line variations.
Capacitor
Single
Dual
Recommended capaci5 VDC
4.7 μF
5 VDC 10.0 μF 4.7 μF
tor values are given in
2.2 μF
9 VDC
4.7 μF
2.2 μF
the table at right. For 12 VDC
applications requir- 24 VDC
1.0 μF
12 VDC 2.2 μF
1.0 μF
ing very low output
15 VDC 1.0 μF 0.47 μF
noise levels, a simple
LC filter should be effective.
4. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Efficiency
(%, Typ)
68
70
71
72
69
70
72
72
69
71
72
72
70
72
73
73
70
72
73
73
72
72
73
73
Fuse Rating
Slow-Blow
(mA)
500
500
500
500
500
500
500
500
200
200
200
200
200
200
200
200
100
100
100
100
100
100
100
100
Derating Curve
Mechanical Dimensions (Single Output)
Mechanical Dimensions (Dual Output)
Pin
Connections
Pin
Single
1
2
4
6
7
9
10
+Vin
+Vin
-Vin
-Vin
-Vout No Pin
+Vout No Pin
No Pin +Vout
No Pin -Vout
No Pin Common
Dual
MicroPower Direct
www.micropowerdirect.com
292 Page Street, STE D, Stoughton, MA 02072
• TEL: (781) 344-8226
Notes:
• All dimen
dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is ma
marked by a “dot” or indentation
on the sid
side of the unit
•
FAX: (781) 344-8481
•
E-Mail: [email protected]