HITRON HAM16S

H HiTRON
ON-BOARD UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR
POWER SUPPLIES 16 WATTS SINGLE & DUAL OUTPUT
HAM16S & HAM16D SERIES
FEATURES:
ON-BOARD AC/DC MODULAR
POWER SUPPLIES
UNIVERSAL AC INPUT RANGE
COMPACT IN SIZE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB.22/ FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: 90-264Vac.
Input Frequency: 47-63 Hz. (50/60 Hz. Nom.).
Input Current: 0.33A @115Vac/0.16A @230Vac typical.
Inrush Current: 32.5A typical peak @ 230Vac.
Input Fuse: Use external fuse. 1.0A/250Vac. for the
primary fuse is suggested.
Dielectric Withstand: Meet IEC950.
3,000Vac-Output/Input.
1,500Vac-Input/GND.
500Vac-Output/GND.
EMI: Meet CISPR PUB.22 / FCC Class B.
Hold-up time: 20mS @115Vac, 120mS @230Vac typical.
Earth Leakage: Less than 3.5mA @230Vac typical.
Remote On/Off: TTL/CMOS-Compatible Output Control.
Positive Logic version for Standard set up:
ON(Enable)=Open(or 2.5-5.0Vdc above Com)
OFF(Disable)=Short(or 0-0.8Vdc above Com)
Negative Logic version option available by adding a
“N”suffix to the end of Model #.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 12-17 Watts typical.
Output Indicator: LED.
Line Regulation: Various with output voltage.
HAM16S ±0.1% typical.
HAM16D ±0.5% typical.
Load Regulation: Various with output voltage.
HAM16S ±1.0% typical.
HAM16D ±2.0-4.0% typical.
Noise & ripple: 1.0% typical peak to peak.
OVP: Built-in on main output.
Adjustability: From -10% of main output till OVP.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: 70-82% typical. (Various with output voltage).
Switching Frequency: 83K Hz.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Typical peak deviation 250mV,
Recovery time < 3mS for a 25% load change.
Case: Impact resistant thermo-plastic enclosure.
Power Density: 3.10Watts. / Cubic inch.
Safety Standard: EN60950/ UL1950 Class I.
MTBF: 110,000 hours. Mil Std 217, 25°C.
Operating Temperature: -10 to +70°C range.
-10°C to +50°C full load without derating.
From +50°C, derating linearly to half load @+70°C.
(Refer to Derating Chart.)
Storage Temperature: -20°C to +85°C.
Temperature Coefficient: 0.02% /°C.
Humidity: Up to 95%RH, Non-condensing.
Cooling: Convection cooling for +50°C @ full load.
At least 100LFM moving air is recommended
for full load >+50°C in a confined area.
Commercial Grade only.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load.
Due to requests in market and advances in technology, specifications subject to change without notice.
-7-
OUTPUT VOLTAGE/ CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO.
HAM16S-033370
HAM16S-050300
HAM16S-090170
HAM16S-120135
HAM16S-150110
HAM16S-240070
HAM16S-480035
DUAL OUTPUT
VO1 ★ @
TYP.
3.70A
3.00A
1.70A
1.35A
1.10A
0.70A
0.35A
VOLT.
3.3V
5.0V
9.0V
12.0V
15.0V
24.0V
48.0V
PEAK
4.44A
3.60A
2.04A
1.62A
1.32A
0.84A
0.42A
MODEL NO.
HAM16D-033180
HAM16D-050150
HAM16D-120068
HAM16D-150055
+VO1 ★ @
TYP. VOLT. MAX.
1.80A +3.3V
2.07A
1.50A +5.0V
1.72A
0.68A +12.0V
0.78A
0.55A +15.0V
0.63A
TYP
1.80A
1.50A
0.68A
0.55A
-VO2 ‖
VOLT.
-3.3V
-5.0V
-12.0V
-15.0V
MAX.
2.07A
1.72A
0.78A
0.63A
Symbols: "★" OVP built-in.
"@" Adjustable.
"‖" Double Feedback.
Note: (1) Max. (maximum load) is the continuous operating load of each rail,
but the max. load of each rail can not be drawn from all outputs at the same time.
(2) Peak output, less than 60 Sec. with duty cycle <10%.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 145.0g(5.11Oz)
PIN ASSIGNMENT
PIN NO.
PIN #1.
PIN #2.
PIN #3.
PIN #4.
PIN #5.
PIN #6.
PIN #7.
SINGLE
AC-GROUND
AC-NEUTRAL
AC-LINE
+VO1
NO PIN
DC COM
Remote ON/OFF
DERATING CHART
CASE SIZE: AM03
-8-
DUAL
AC-GROUND
AC-NEUTRAL
AC-LINE
+VO1
DC-COM
-VO2
Remote ON/OFF