MPE-100FS Series Si l O Single Output, t t 100W Compact, Enclosed AC/DC Power Supplies Electrical Specifications Key Features: • 100W Output Power • Selectable 88-264 AC Input • EN60950 Approved • Wide Temp Operation • Seven Single Output Models Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Input Frequency Input Current • Meets EN55022 Inrush Current • >300 kHour MTBF Safety Ground Leakage Current • Compact Metal Enclosure Hold-Up Time Set-Up Time Rise Time Temperature Coefficient Short Circuit Protection Over Voltage Protection Overload Protection Max. 132 264 370 63 Units 0.7 1.0 mA Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide 115 VAC 15 230 VAC 20 230 VAC 1,000 230 VAC 30 ±0.02 Continuous (Autorecovery) See Note 3 115 See Note 4 135 Max. Units VAC VDC Hz A Pk mSec mSec mSec %/°C 135 165 % % Max. Units General Parameter Isolation Voltage Isolation resistance EMI/RFI MicroPower Direct EMC Compliance 292 Page Street Suite D Stoughton, MA 02072 USA Switching Frequency T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Min. Typ. 88 115 Switch Selectable 176 220 248 47 See Model Selection Guide Cold Start, 115 VAC 30.0 Cold Start, 230 VAC 60.0 115 VAC 240 VAC Output Parameter Output Voltage Output Current Output Voltage Adjustment Output Voltage Tolerance, See Note 1 Ripple & Noise (20 MHz), See Note 2 RoHS Compliant Conditions Conditions Input to Output Input to Ground Output to Ground 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 1,500 500 Typ. VAC 100 MΩ EN 55022; EN 61000-3-2, -3 IEC/EN 61000-4-2, -6, -8, -11 IEC/EN61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 75 kHz Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. -10 +25 -20 Free Air Convection RH, Non-condensing Ambient Max. +60 +85 Units °C °C 95 % Physical Case Size Case Material Weight 7.83 x 3.86 x 1.50 Inches (199.0 x 98.0 x 38.0 mm) Vented Metal Enclosure 22.9 Oz (0.65 kg) Reliability Specifications Parameter MTBF Safety Standards Vibration Conditions Min. Typ. Max. Units MIL HDBK 217F, 25°C, Gnd Benign 300 kHours CAN/CSA-C22.2 No 60950-1-03, ANSI/UL Std No 60950-1, IEC 60950 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis Model Selection Guide Input Current (A) Model Number MPE-100FS-05 MPE-100FS-7.5 MPE-100FS-12 MPE-100FSS-15 MPE-100FS-24 MPE-100FS-27 MPE-100FS-48 115 VAC 230 VAC 3.15 3.15 3.15 3.15 3.15 3.15 3.15 1.5 1.5 1.5 1.5 1.5 1.5 1.5 Notes: 1. Output voltage tolerance includes the the effects of set point accuracy, line regulation and load regulation. 2. Ripple and noise is measured at 20 MHz bandwidth using a 12 inch twisted pair wire to connect to the power supply terminals. A 0.1 µF and a 47 µF capacitor are connected in parallel as close to the power supply terminals as possible. 3. Overvoltage protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 4. The overload protection circuit shuts down the output. The unit recovers automatically when the fault condition is removed. 5. It is recommended that a fuse be used on the input of a power supply for protection. For the MPE-100FS series, a 7.5A/250 VAC slow blow should be used. Output Voltage (VDC) Rated 5.0 7.5 12.0 15.0 24.0 27.0 48.0 Adjust Current (A) Rated 4.5 - 5.5 6.75 - 8.25 10.8 - 13.2 13.5 - 16.5 21.6 - 26.4 24.3 - 29.7 43.2 - 52.8 20.0 13.5 8.5 6.7 4.5 3.5 2.2 Range Output Tolerance (%) 0 to 20.0 0 to 13.5 0 to 8.5 0 to 6.7 0 to 4.5 0 to 3.5 0 to 2.2 Ripple & Noise Efficiency (%, Typ) (mV p-p) ±2.0 ±1.0 ±1.0 ±1.0 ±1.0 ±1.0 ±1.0 100 125 125 125 150 150 150 76 78 80 81 83 83 84 Mechanical Dimensions Pin Connections Pin Function 1 2 3 4 5 6 7 AC-Line AC-Neutral AC-Ground -Vout -Vout +Vout +Vout Derating Curve Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) Static Characteristics MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]