NLP110 Medical Series Single and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES • • • • • • • • • 80-110W AC/DC Universal Input Switch Mode Power Supplies 1 Provides low voltage outputs Compliance to EN61000-3-2 (Power Factor = 0.98) Smallest industry standard package 6.5 x 3.0 x 1.26 inches 90VAC to 264VAC universal input range UL, cUL, and VDE safety approvals and CE-Marked to MDD Overvoltage and short circuit protection VDE0871-A, EN55022-A, EN55011-A conducted noise VDE0871-A, EN55022-A, EN55011-A radiated noise Meets all applicable and relevant immunity standards EN61000-4-2,4,5 and 6 The NLP110 Medical is a series of 110W AC/DC open-frame power supplies in a 3” x 6.5” x 1.26” package. The NLP110 Medical is power factor corrected to meet EN61000-3-2 and is available in single and multiple output models. The multiple output models have a capability that is unique to the power supply market - they can deliver equal amounts of current on multiple low voltage outputs to support designs that will span the industry transition from 5V logic to 3.3V logic. The NLP110 Medical is practically the same size as a 65 Watt 3” x 5” product, e.g. NLP65 Medical - the one difference is that the footprint is a mere 1.5 inches longer. The NLP110 Medical series, with full medical safety approval per UL2601-1, C22.2 No. 601.1-M90, VDE0750, IEC60601-1 and EN60601-1 and CE marked, greatly accelerating design-in time and reducing system compliance costs. 2 YEAR WARRANTY SPECIFICATIONS All specifications are typical at nominal input, full load at 25°C unless otherwise stated OUTPUT SPECIFICATIONS EMC CHARACTERISTICS (continued) Total regulation (Line and load) Main output Auxiliary outputs Rise time At turn-on Transient response Main output 75% to 100% step at 0.1A/µs ±2.0% ±5.0% 1.0s, max. 5.0% or 250mV max. dev., 1ms max. recovery to 1% Temperature coefficient ±0.02%/°C Overvoltage protection Main outputs Short circuit protection Cyclic operation Minimum output current Single and multiple 125%, ±10% See table Hold-up time Input surge current (cold start) 120VAC 230VAC Safety ground leakage current 230VAC, 50Hz Input current 120VAC 120VAC 230VAC 230VAC Input fuse UL/IEC127 EMC CHARACTERISTICS @ @ @ @ 120VAC, 80W (-9605) 75% min. Input/output Input/chassis 4000VAC 1500VAC Approvals and standards EN60601-1, IEC60601-1,VDE0750, UL2601-1, C22.2 No. 601.1-M90 47Hz to 63Hz ENVIRONMENTAL SPECIFICATIONS (12) EN61000-4-2 EN61000-4-2 Thermal performance rms rms rms rms F3.15A H, 250VAC EN55022, FCC part 15 EN55022, FCC part 15 EN61000-3-2 283g (10oz) MTBF (@ 25°C) 0.9A 1.3A 0.48A 0.7A Level A Level A Compliant 16.7ms @ 110W Isolation voltage <100µA 80W 110W 80W 110W 3 3 3 3 Efficiency 90 to 264VAC 18A max. 35A max. Level Level Level Level 120VAC, 60Hz Weight Universal input Input frequency range Conducted emissions Radiated emissions Harmonic current emission correction ESD air ESD contact EN61000-4-5 EN61000-4-4 EN61000-4-3 EN61000-4-6 GENERAL SPECIFICATIONS Continuous INPUT SPECIFICATIONS Input voltage range (See Note 6) Surge Fast transients Radiated immunity Conducted immunity MIL-HDBK-217F 220,000 hours min. (9) Operating ambient, 0°C to +50°C (See derating curve) Non-operating -40°C to +85°C 50°C to 70°C, ambient, Derate to convection cooled 50% load 0°C to 50°C, ambient, 80W convection cooled 0°C to 50°C ambient, 110W 150LFM forced air Peak (0°C to +50°C, 60s) (See Note 3) Relative humidity Non-condensing Altitude Operating Non-operating Vibration (See Note 8) 5Hz to 500Hz Shock per MIL-STD-810E 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4G rms peak 516.4 Part IV Level 3 Level 3 File Name: NLP110M.PDF Rev: 13 Dec 2002 NLP110 Medical Series Single and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT CURRENT OUTPUT VOLTAGE PEAK MIN (6) MAX (1) 150LFM (2) 300LFM MODEL NUMBERS 0.5A 15A 22A 22A 22A 50mV ±2.0% NLP110-9905 6.4A 9.2A 9.2A 11.5A 120mV ±2.0% NLP110-9912 +48V 0A 1.6A 2.3A 2.3A 2.5A 240mV ±2.0% NLP110-9917 +24V 0.2A 3.2A 4.6A 4.6A 6.0A 240mV ±2.0% NLP110-9924 +5V (A) 0.5A 13A 16A 18A 18A 50mV ±2.0% NLP110-9993 +3.3V (B) 0.2A 13A 16A 20A 20A 50mV ±2.0% +12V 0A 0.65A 1.0A 1A 1.0A 120mV ±5.0% +3.3V (A) 0.5A 13A 16A 20A 22A 50mV ±2.0% +2.5V (B) 0.1A 13A 16A 20A 22A 50mV ±2.0% +12V 0A 0.65A 1.0A 1A 1.0A 120mV ±5.0% +12V (A) 0.2A 6.5A 8.5A 8.5A 10A 1200mV ±2.0% +3.3V (B) 0.5A 13A 16A 20A 22A 50mV ±2.0% -12V 0A 0.65A 1.0A 1A 1.0A 120mV ±5.0% +12V (A) 0.2A 6.5A 8.5A 8.5A 10A 120mV ±2.0% +5V (B) 0.2A 13A 16A 18A 22A 50mV ±2.0% -12V 0A 0.65A 1.0A 1A 1.0A 120mV ±5.0% 6 5 TOTAL REGULATION 0.3A N 4 (5) +5V 1 3 RIPPLE +12V Notes 2 (4) (3) Free air convection. Multiple output units: maximum continuous output power not to exceed 80W. For -9993; I3.3V = 13A max.; I5.0V = 13A max.; I3.3V + I5.0V ≤ 16A. For -9994; I3.3V = 13A max.; I2.5V = 13A max.; I3.3V + I2.5V ≤ 16A For -9995; I3.3V = 13A max.; I12V = 6.5A max.; I3.3V + I12V ≤ 16A. For -9908; I5.0V = 13A max.; I12V = 6.5A max.; I5.0V + I12V ≤ 16A. Single output units: maximum continuous output power not to exceed; 75W on –9905; 76.8W on –9912,-9924, and –9917. 150LFM forced air cooling from L4 side. Multiple output units: maximum continuous output power not to exceed 105W. For -9993; I3.3V = 16A max.; I5.0V = 16A max.; I3.3V + I5.0V ≤ 20A. For -9994; I3.3V = 16A max.; I2.5V = 16A max.; I3.3V + I2.5V ≤ 20A For -9995; I3.3V = 16A max.; I12V = 8.5A max.; I3.3V + I12V ≤ 20A. For -9908; I5.0V = 16A max.; I12V = 8.5A max.; I5.0V + I12V ≤ 20A. Single output units: maximum continuous output power not to exceed 110W for all models. 300LFM forced air cooling from L4 side. Multiple output units: maximum continuous output power not to exceed 110W. For -9993; I3.3V = 20A max.; I5.0V = 18A max.; I3.3V + I5.0V ≤ 22A. For -9994; I3.3V = 20A max.; I2.5V = 20A max.; I3.3V + I2.5V ≤ 22A For -9995; I3.3V = 20A max.; I12V = 8.5A max.; I3.3V + I12V ≤ 22A. For -9908; I5.0V = 20A max.; I12V = 8.5A max.; I5.0V + I12V ≤ 22A. Single output units: maximum continuous output power not to exceed 110W for all models. Peak output current lasting less than 30 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation limits. Figure is peak-to-peak for convection power rating. Output noise measurements are made across a 20MHz bandwidth using a 6” twisted pair, terminated with a 10µF electrolytic capacitor and a 0.1µF ceramic capacitor. 7 8 9 10 11 12 13 NLP110-9994 NLP110-9995 (7) NLP110-9908 (7) Minimum load required for correct start-up and operation on single outputs and on main output of multiple versions. Failure to observe minimum load on main output will not allow the supply to start-up correctly. Some electronic test loads have a large delay time before they start drawing current even though the voltage from the supply is present. During this time delay, there is no load on the output and as a result, the supply cannot start-up properly and maintain its correct output voltage. In these instances, a dummy resistive load across the output may be necessary to load the output of the supply until the test load can function correctly and draw the intended minimum load. Minimum load required on auxiliary outputs to maintain regulation. For models NLP110-9908 and NLP110-9995, the 12V output is floating. For -12V output, pin 11 on J2 has to be connected to Return making pin 12 the -12V output Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G rms 5Hz to 500Hz. For optimum reliability, no part of the heatsink should exceed 110oC, and no semiconductor case temperature should exceed 120oC. CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. The EMI specifications reference measurements made with the power supply mounted on a grounded metal sheet extending 1 inch beyond each edge, using an unshielded cable. No external filtering required during conducted emissions testing but some applications may require additional filtering to achieve system compliance. A line choke, (AC input cords looped twice through an EMI suppression toroid) was used during radiated emissions testing. Considerable radiated testing in 1U six-sided boxes has shown that units can meet level B in typical systems. Application support is available from the factory to assist with EMI compliance. All models require a minimum mounting stand-off of 6.35mm (0.25 inches) in the end use product. International Safety Standard Approvals VDE0750/IEC60601-1 and EN60601-1 UL2601-1 and C22.2 No. 601.1-M90. www.artesyn.com File Name: NLP110M.PDF Rev: 13 Dec 2002 NLP110 Medical Series Single and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies 3 For the most current data and application support visit www.artesyn.com/powergroup/products.htm Mechanical Notes A All dimensions are in inches (mm). 2 6.50 (165.10) 6.050 (153.670) 0.23 (5.842) J4 4 3 12 1 2.550 (64.770) J2 Recommended direction for forced air relative to power supply orientation shown below. ! F1 1 3 T1 (REF.) J1 J3 J5 2 1 ALL DIMENSIONS IN INCHES (mm) MAXIMUM COMPONENT HEIGHT IS 1.26 (32.00) INPUT PIN CONNECTIONS J1 Pin 1 AC Neutral Pin 2 No Connection Pin 3 AC Line J3 Pin 1 V (A) Sense + Pin 2 V (A) Sense J4 Pin 1 Safety Earth J5 Pin 1 V (B) Sense + Pin 2 V (B) Sense - J2 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 3.00 (76.20) 1 1 2 OUTPUT PIN CONNECTIONS SINGLE TRIPLE No Connection V (B) No Connection V (B) No Connection V (B) Return Return Return Return Return Return Return Return V (A) V (A) V (A) V (A) V (A) V (A) No Connection V (C) No Connection V (C) Return 1 2 3 4 Optimum. Very good. Good. Not recommended. 0.23 (5.842) DERATING CURVE Output Power (Watts) 110W 80W 150 LFM FORCED AIR COOLING NATURAL CONVECTION COOLING 55W 40W 0°C 10°C20°C30°C40°C50°C60°C 70°C (7) Input and output connectors Mating connectors AC (J1) connector type Molex 26-60-4030 or equivalent. AC (J1) mating connector type Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals. DC (J2) connector type 12 position Molex Spox type 26-48-1125 or equivalent. DC (J2) mating connector type Molex Spox type 26-03-3121 and contact 08-52-0113. Sense (J3) connector type Molex 22-23-2021 or equivalent. Sense (J3) mating connector type Molex 22-01-3027 and contact 08-50-0113. Earth (J4) connector type Male 0.250 quick disconnect. Earth (J4) mating connector type Molex 90028. Sense (J5) connector type Leoco 2421P02H000. Sense (J5) mating connector type Leoco 2420S020000 and contact 2453TPB00V1. Data Sheet © Artesyn Technologies® 2002 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. www.artesyn.com File Name: NLP110M.PDF Rev: 13 Dec 2002