RSG PBA30F

Ordering information
Unit type
PB
PBA30F
PB
1
A
30
2
3
F
4
Recommended Noise Filter
NAC-06-472
R
-O
5
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*to connect with several devices.
-O
6
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional
C :with Coating
G :Low leakage current
E :Low leakage current
and EMI class A
T :Vertical terminal block
J :Connector type
N :with Cover
(UL508 is pending for approval)
N1 :with DIN rail
V :Output voltage setting
potentiometer externally
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA30F-3R3
19.8
3.3V 6A
PBA30F-5
30
5V 6A
PBA30F-9
30.6
9V 3.4A
PBA30F-12
30
12V 2.5A
PBA30F-15
30
15V 2A
PBA30F-24
31.2
24V 1.3A
PBA30F-48
31.2
48V 0.65A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
PBA30F-3R3
PBA30F-5
PBA30F-9
PBA30F-12
PBA30F-15
PBA30F-24
PBA30F-48
AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage *3)
ACIN 100V 0.50typ (Io=100%) 0.70typ (Io=100%)
ACIN 200V 0.30typ (Io=100%) 0.40typ (Io=100%)
50/60 (47 - 440) or DC
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *1
RIPPLE[mVp-p]
-10 - 0C *1
0 to +50C *1
RIPPLE NOISE[mVp-p]
-10 - 0C *1
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (At only AC input)
CONDUCTED NOISE
CE MARKING
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
68typ
74typ
75typ
76typ
78typ
78typ
79typ
69typ
77typ
77typ
78typ
81typ
81typ
81typ
15typ (Io=100%) (At cold start)
30typ (Io=100%) (At cold start)
0.30/0.65max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
3.3
5
9
12
15
24
48
6
6
3.4
2.5
2
1.3
0.65
20max
20max
36max
48max
60max
96max
192max
40max
40max
100max
100max
120max
150max
240max
80max
80max
120max
120max
120max
120max
150max
140max
140max
160max
160max
160max
160max
200max
120max
120max
150max
150max
150max
150max
250max
160max
160max
180max
180max
180max
180max
300max
50max
50max
90max
120max
150max
240max
480max
60max
60max
120max
150max
180max
290max
600max
20max
20max
36max
48max
60max
96max
192max
200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
2.85 - 3.60
4.50 - 5.50
7.50 - 10.0
10.0 - 13.2
13.2 - 18.0
19.2 - 27.0
3.30 - 3.40
5.00 - 5.15
9.00 - 9.36
12.00 - 12.48
15.00 - 15.60
24.00 - 24.96
Works over 105% of rated current and recovers automatically
4.00 - 5.25
5.75 - 7.00
11.5 - 14.0
15.0 - 18.0
20.0 - 25.0
30.0 - 37.0
LED (Green)
None
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
-10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2 (Not built-in to active filter *4)
31X78X103mm (without terminal block) (WXHXD) / 270g max (without cover)
Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 Derating is required.
*4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
A-8
*
*
*
Parallel operation with other model is not possible.
Derating is required when operated with cover.
A sound may occur from power supply at peak loading.
39.0 - 53.0
48.00 - 49.92
58.0 - 65.0
PBA30F
PB
Block diagram
FUSE
AC250V
3.15A
INRUSH
CURRENT
LIMIT
NOISE
FILTER
AC IN
85 - 264V
RECTIFIER
AND
FILTER
FG
TRANSFORMER
CONTROL
INVERTER
RECTIFIER
AND
FILTER
DC OUT
CURRENT
SENSING
Photocoupler
CONTROL
Photocoupler
OVER VOLTAGE
PROTECTION
External view
¶ External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
18
Voltage adjust
12.2 ±1.5
2.5 LED
16.5±2
103
Cover name plate
M3
78
Cover (option)
-V
11.5 9.5
AC(N)
15.1±1.5
46±0.5
Terminal cover
22.6 ±1.5
40.5
Point A:C102
2-M3
Mounting hole
Name plate
2-M3
Mounting hole
18
31
PBA30F
PBW30F
34.5
FG
AC(L)
36.5
7.5
70.5
+V
¶ Tolerance : ±1
¶ Mass : 270g or less (without cover)
¶ PCB Material/thickness : CEM3 / 1.6mm
¶ Chassis material : Electric galvanizing steel board
¶ Dimensions in mm
¶ Mounting torque : 0.6N • m(6.3kgf • cm)max
¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max
¶ Please connect safety ground to the unit in 2-M3 holes.
75 ±0.5
8.5
Distribution:
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de
■
■
Änderungen vorbehalten / subject to change without notice
■
■
■
A-9