Ordering information Unit type PB PBA30F PB 1 A 30 2 3 F 4 Recommended Noise Filter NAC-06-472 R -O 5 High voltage pulse noise type : NAP series Low leakage current type : NAM series *The Noise Filter is recommended *to connect with several devices. -O 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional C :with Coating G :Low leakage current E :Low leakage current and EMI class A T :Vertical terminal block J :Connector type N :with Cover (UL508 is pending for approval) N1 :with DIN rail V :Output voltage setting potentiometer externally Cover is optional MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PBA30F-3R3 19.8 3.3V 6A PBA30F-5 30 5V 6A PBA30F-9 30.6 9V 3.4A PBA30F-12 30 12V 2.5A PBA30F-15 30 15V 2A PBA30F-24 31.2 24V 1.3A PBA30F-48 31.2 48V 0.65A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS PBA30F-3R3 PBA30F-5 PBA30F-9 PBA30F-12 PBA30F-15 PBA30F-24 PBA30F-48 AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage *3) ACIN 100V 0.50typ (Io=100%) 0.70typ (Io=100%) ACIN 200V 0.30typ (Io=100%) 0.40typ (Io=100%) 50/60 (47 - 440) or DC ACIN 100V ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS (At only AC input) CONDUCTED NOISE CE MARKING HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] 68typ 74typ 75typ 76typ 78typ 78typ 79typ 69typ 77typ 77typ 78typ 81typ 81typ 81typ 15typ (Io=100%) (At cold start) 30typ (Io=100%) (At cold start) 0.30/0.65max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN) 3.3 5 9 12 15 24 48 6 6 3.4 2.5 2 1.3 0.65 20max 20max 36max 48max 60max 96max 192max 40max 40max 100max 100max 120max 150max 240max 80max 80max 120max 120max 120max 120max 150max 140max 140max 160max 160max 160max 160max 200max 120max 120max 150max 150max 150max 150max 250max 160max 160max 180max 180max 180max 180max 300max 50max 50max 90max 120max 150max 240max 480max 60max 60max 120max 150max 180max 290max 600max 20max 20max 36max 48max 60max 96max 192max 200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage. 20typ (ACIN 100V, Io=100%) 2.85 - 3.60 4.50 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 3.30 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 Works over 105% of rated current and recovers automatically 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 LED (Green) None AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature) -10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Low Voltage Directive, EMC Directive Complies with IEC61000-3-2 (Not built-in to active filter *4) 31X78X103mm (without terminal block) (WXHXD) / 270g max (without cover) Convection *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 Derating is required. *4 When two or more units are used,they may not comply with the harmonic attenuator. Please contact us for details. A-8 * * * Parallel operation with other model is not possible. Derating is required when operated with cover. A sound may occur from power supply at peak loading. 39.0 - 53.0 48.00 - 49.92 58.0 - 65.0 PBA30F PB Block diagram FUSE AC250V 3.15A INRUSH CURRENT LIMIT NOISE FILTER AC IN 85 - 264V RECTIFIER AND FILTER FG TRANSFORMER CONTROL INVERTER RECTIFIER AND FILTER DC OUT CURRENT SENSING Photocoupler CONTROL Photocoupler OVER VOLTAGE PROTECTION External view ¶ External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details. 18 Voltage adjust 12.2 ±1.5 2.5 LED 16.5±2 103 Cover name plate M3 78 Cover (option) -V 11.5 9.5 AC(N) 15.1±1.5 46±0.5 Terminal cover 22.6 ±1.5 40.5 Point A:C102 2-M3 Mounting hole Name plate 2-M3 Mounting hole 18 31 PBA30F PBW30F 34.5 FG AC(L) 36.5 7.5 70.5 +V ¶ Tolerance : ±1 ¶ Mass : 270g or less (without cover) ¶ PCB Material/thickness : CEM3 / 1.6mm ¶ Chassis material : Electric galvanizing steel board ¶ Dimensions in mm ¶ Mounting torque : 0.6N • m(6.3kgf • cm)max ¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max ¶ Please connect safety ground to the unit in 2-M3 holes. 75 ±0.5 8.5 Distribution: RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de ■ ■ Änderungen vorbehalten / subject to change without notice ■ ■ ■ A-9