ERICSSON PBL38620-2QNS

June 1999
PBL 386 20/2
Subscriber Line
Interface Circuit
Description
Key Features
The PBL 386 20/2 Subscriber Line Interface Circuit (SLIC) is a 90 V bipolar integrated
circuit for use in PBX,Terminal adapters and other telecommunications equipment.
The PBL 386 20/2 has been optimized for low total line interface cost and a high
degree of flexibility in different applications.
The PBL 386 20/2 has constant current feed, programmable to max. 30 mA.
A second lower battery voltage may be connected to the device to reduce short
loop power dissipation. The SLIC automatically switches between the two battery
supply voltages without need for external components or external control.
The SLIC incorporates loop current, ground key and ring trip detection functions.
The PBL 386 20/2 is compatible with loop start signaling.
Two- to four-wire and four- to two-wire voice frequency (VF) signal conversion is
accomplished by the SLIC in conjunction with either a conventional CODEC/filter or
with a programmable CODEC/filter, e.g. SLAC, SiCoFi, Combo II. The programmable
two-wire impedance, complex or real, is set by a simple external network.
Longitudinal voltages are suppressed by a feedback loop in the SLIC and the
longitudinal balance specifications meet Bellcore TR909 requirements.
The PBL 386 20/2 package options are 24-pin SSOP, 24-pin SOIC and 28 pin PLCC.
• 24-pin SSOP package
• High and low battery with automatic
switching
• 60 mW on-hook power dissipation in
active state
• On-hook transmission
• Long loop battery feed tracks Vbat for
maximum line voltage
• Only +5 V feed in addition to battery
• Selectable transmit gain (1x or 0.5x)
• No power-up sequence
• 44V open loop voltage @ -48V battery
feed
• Full longitudinal current capability
during on-hook state
• Analog over temperature protection
permits transmission while the
protection circuit is active
• Integrated Ring Relay driver
• Ground key detector
• Programmable signal headroom
Ring Relay
Driver
DT
C1
Ring Trip
Comparator
DR
TIPX
Ground Key
Detector
RINGX
RRLY
Input
Decoder
and
Control
C2
C3
DET
HP
/2
L
38 PB
6 L
20
/2
38
6
20
PSG
PLC
B
Two-wire
Interface
POV
P
VCC
Line Feed
Controller
and
Longitudinal
Signal
Suppression
LP
VBAT2
VBAT
Off-hook
Detector
PLD
REF
AGND
BGND
PBL
386
20/2
VTX
VF Signal
Transmission
PTG
RSN
24-pinSOIC, 24-pin SSOP, 28-pin PLCC
Figure 1. Block diagram.
1
PBL 386 20/2
Maximum Ratings
Parameter
Symbol
Min
Max
Unit
Temperature, Humidity
Storage temperature range
Operating temperature range
Operating junction temperature range, Note 1
TStg
TAmb
TJ
-55
-40
-40
+150
+110
+140
°C
°C
°C
Power supply, 0°C ≤ TAmb ≤ +70°C
VCC with respect to A/BGND
VBat2 with respect to A/BGND
VBat with respect to A/BGND, continuous
VBat with respect to A/BGND, 10 ms
VCC
VBat2
VBat
VBat
-0.4
VBat
-75
-80
6.5
0.4
0.4
0.4
V
V
V
V
Power dissipation
Continuous power dissipation at TAmb ≤ +70 °C
PD
1.5
W
0.3
V
Ground
Voltage between AGND and BGND
Relay Driver
Ring relay supply voltage
VG
-0.3
BGND+14 V
Ring trip comparator
Input voltage
Input current
VDT, VDR
IDT, IDR
VBat
-5
AGND
5
V
mA
Digital inputs, outputs (C1, C2, C3, DET)
Input voltage
VID
-0.4
VCC
V
Output voltage
VOD
-0.4
VCC
V
TIPX and RINGX terminals, 0°C < TAmb < 70°C, VBat = -50V
Maximum supplied TIPX or RINGX current
TIPX or RINGX voltage, continuous (referenced to AGND), Note 2
ITIPX, IRINGX
VTA, VRA
-100
-80
+100
2
mA
V
TIPX or RINGX, pulse < 10 ms, tRep > 10 s, Note 2
VTA, VRA
VBat -10
5
V
TIPX or RINGX, pulse < 1 µs, tRep > 10 s, Note 2
TIPX or RINGX, pulse < 250 ns, tRep > 10 s, Notes 2 & 3
VTA, VRA
VTA, VRA
VBat -25
VBat -35
10
15
V
V
Parameter
Symbol
Min
Max
Unit
Ambient temperature
VCC with respect to AGND
VBat with respect to AGND
AGND with respect to BGND
TAmb
VCC
VBat
VG
0
4.75
-58
-100
+70
5.25
-8
100
°C
V
V
mV
Recommended Operating Condition
Notes
1. The circuit includes thermal protection. Operation at or above 140°C junction temperature may degrade device reliability.
2. With the diodes DVB and DVB2 included, see figure 12.
3. RF1 and RF2 ≥ 20 Ω is also required. Pulse is applied to TIP and RING outside RF1 and RF2.
2
PBL 386 20/2
Electrical Characteristics
0 °C ≤ TAmb ≤ +70 °C, PTG = open (see pin description), VCC = +5V ±5 %, VBat = -58V to -40V, VBAT2 = -17V, RLC=38.3 kΩ, IL = 22 mA.
RL = 600 Ω, RF1= RF2=RP1= RP2 =0 Ω, RRef = 49.9 kΩ, CHP = 47 nF, CLP=0.15 µF, RT = 120 kΩ, RSG = 0 kΩ, RRX = 60 kΩ, RR = 52.3 kΩ,
ROV=∞ unless otherwise specified. Current definition: current is positive if flowing into a pin.
Ref
fig
Parameter
Conditions
Min
Typ
Max
Unit
Two-wire port
Overload level, VTRO
2
On-Hook, ILdc < 5mA
Input impedance, ZTR
Longitudinal impedance, ZLOT, ZLOR
Longitudinal current limit, ILOT, ILOR
Longitudinal to metallic balance, BLM
Longitudinal to metallic balance, BLME
BLME = 20 · Log
10
Ω/wire
mArms /wire
53
53
dB
dB
0.2 kHz < f < 1.0 kHz
1.0 kHz < f < 3.4 kHz
53
53
75
70
dB
dB
0.2 kHz < f < 1.0 kHz
1.0 kHz < f < 3.4 kHz
53
53
75
70
dB
dB
0.2 kHz < f < 3.4 kHz
40
50
dB
1.0
1.0
VPeak
VPeak
ZT/200
20
35
3
ELo
VTR
Longitudinal to four-wire balance, BLFE
BLFE = 20 · Log
Active state
1% THD, ROV = ∞
Note 1
Note 2
0 < f < 100 Hz
active state
IEEE standard 455-1984
0.2 kHz < f < 1.0 kHz
1.0 kHz < f < 3.4 kHz
3
ELo
VTX
Metallic to longitudinal balance, BMLE
V
BMLE = 20 · Log TR ; ERX = 0
VLo
4
C
TIPX
VTX
Figure 2. Overload level, VTRO , two-wire
port
RL
VTRO
ILDC
PBL 386 20/2
1
<< RL, RL= 600 Ω
ωC
RINGX
RT
E RX
RSN
RRX
RT = 120 kΩ, RRX = 60 kΩ
Figure 3. Longitudinal to metallic (BLME)
and Longitudinal to four-wire (BLFE) balance
1
<< 150 Ω, RLR =RLT =RL /2=300Ω
ωC
TIPX
ELo
C
VTX
RLT
V TR
PBL 386 20/2
RT
V TX
RLR
RINGX
RSN
RRX
RT = 120 kΩ, RRX = 60 kΩ
3
PBL 386 20/2
Parameter
Ref
fig
Four-wire to longitudinal balance, BFLE
4
Two-wire return loss, r
Four-wire transmit port (VTX)
Overload level, VTXO
5
On-hook, IL < 5mA
Output offset voltage, ∆VTX
Output impedance, zTX
Typ
0.2 kHz < f < 3.4 kHz
E
BFLE = 20 · Log RX
VLo
40
50
dB
0.2 kHz < f < 1.0 kHz
1.0 kHz < f < 3.4 kHz, Note 3
active, IL =0 mA
active, IL =0 mA
active, IL =0 mA
30
20
35
22
- 1.1
VBat+2.5
VBat+3.6
dB
dB
V
V
V
Load impedance > 20 kΩ,
1% THD, Note 4
1.0
0.2 kHz < f < 3.4 kHz
Frequency response
Two-wire to four-wire, g2-4
IRSN = -55 µA
0.2 kHz < f < 3.4 kHz
0.3 kHz < f < 3.4 kHz
1.15
relative to 0 dBm Vrms, 1.0 kHz. ERX = 0 V
0.3 kHz < f < 3.4 kHz
-0.20
f = 8.0 kHz, 12 kHz, 16 kHz
-1.0
15
100
50
VPeak
mV
Ω
1.25
8
1.35
20
V
Ω
VTX
PBL 386 20/2
ratio
0.10
0.1
dB
dB
Figure 4. Metallic to longitudinal and fourwire to longitudinal balance
RLT
V TR
Unit
VPeak
200
6
TIPX
Max
|ZTR + ZL|
|ZTR - ZL|
1.0
-100
Four-wire receive port (RSN)
Receive summing node (RSN) DC voltage
Receive summing node (RSN) impedance
Receive summing node (RSN)
current (IRSN) to metallic loop current (IL)
gain,αRSN
VLo
Min
r = 20 · Log
TIPX idle voltage, VTi
RINGX idle voltage, VRi
VTR
C
Conditions
RT
E RX
1
<< 150 Ω, RLT = RLR = RL /2 =300Ω
ωC
RLR
RINGX
RT = 120 kΩ, RRX = 60 kΩ
RSN
RRX
Figure 5. Overload level, VTXO, four-wire
transmit port
C
TIPX
VTX
RL
ILDC
EL
PBL 386 20/2
RINGX
RT
RT = 120 kΩ, RRX = 60 kΩ
RSN
RRX
4
VTXO
1
<< RL, RL = 600 Ω
ωC
PBL 386 20/2
Parameter
Ref
fig
Four-wire to two-wire, g4-2
6
Four-wire to four-wire, g4-4
Insertion loss
Two-wire to four-wire, G2-4
Four-wire to two-wire, G4-2
Gain tracking
Two-wire to four-wire
6
0 dBm, 1.0 kHz, Note 5
V
G2-4 = 20 · Log TX ; ERX = 0
VTR
Typ
Max
Unit
-0.2
-1.0
-2.0
0.1
0
0
dB
dB
dB
-0.2
0.1
dB
-0.2
0.2
dB
-5.82
dB
-0.2
0.2
dB
-0.1
-0.2
0.1
0.2
dB
dB
-0.1
-0.2
0.1
0.2
dB
dB
12
-78
dBrnC
dBmp
-50
-50
dB
dB
6
PTG = AGND
0 dBm, 1.0 kHz, Note 6
V
G4-2 = 20 · Log TR ; EL = 0
ERX
-6.22
-6.02
6
Ref. -10 dBm, 1.0 kHz, Note 7
-40 dBm to + 0 dBm
-55 dBm to -40 dBm
Ref. -10 dBm
-40 dBm to + 0 dBm
-55 dBm to -40 dBm
6
Noise
Idle channel noise at two-wire
(TIPX-RINGX) or four-wire (VTX) output
Harmonic distortion
Two-wire to four-wire
Four-wire to two-wire
Min
relative to 0 dBm, 1.0 kHz. EL=0 V
0.3 kHz < f < 3.4 kHz
f = 8 kHz, 12 kHz,
16 kHz
relative to 0 dBm.1.0 kHz, EL=0 V
0.3 kHz < f < 3.4 kHz
6
Four-wire to two-wire
Conditions
C-message weighting
Psophometrical weighting
Note 8
6
0 dBm
0.3 kHz < f < 3.4 kHz
-67
-67
12
ILProg = 1 000 - 4.0 (mA)
RLC
1
ILProg = 000 - 4.2 (mA)
RLC
0.92 ILProg ILProg
1.08 ILProg mA
0.95 ILProg ILProg
1.05 ILProg mA
ILProg = 1 000 - 3.9 (mA)
RLC
RLC in kΩ
RL = 0Ω
0.94 ILProg ILProg
1.06 ILProg mA
-100
100
Battery feed characteristics
Constant loop current, ILProg
ILProg @ 30 mA
12
ILProg @ 18 mA
12
Open circuit state loop current, I LOC
C
Figure 6.
Frequency response, insertion loss,
gain tracking.
1
ωC
<< RL, RL = 600 Ω
TIPX
0
µA
VTX
RL
VTR
EL
ILDC
PBL 386 20/2
RINGX
RT
E RX
VTX
RSN
RRX
RT = 120 kΩ, RRX = 60 kΩ
5
PBL 386 20/2
Parameter
Loop current detector
Programmable threshold, ILTh
Ref
fig
Conditions
Min
Typ
Max
Unit
ILTh = 500
RLD
RLD in kΩ, ILTh ≥ 7 mA
0.85·ILTh
ILTh
1.15·ILTh
mA
16
22
mA
0
-20
20
200
-1
mV
nA
V
0.2
0.5
10
V
µA
0.5
VCC
-50
50
V
V
µA
µA
0.7
V
kΩ
15
mW
80
mW
mW
mW
2.0
mA
mA
mA
mA
Ground key detector
Ground key detector threshold
(ITIPX and IRINGX difference to trigger ground key det.)
10
Ring trip comparator
Offset voltage, ∆VDTDR
Source resistance, RS = 0 Ω
-20
Input bias current, IB
IB = (IDT + IDR)/2
-200
Input common mode range, VDT, VDR
VBat+1
Ring relay driver
Saturation voltage, VOL
IOL = 50 mA
Off state leakage current, ILk
VOH = 12 V
Digital inputs (C1, C2, C3)
Input low voltage, VIL
0
Input high voltage, VIH
2.5
Input low current, IIL
VIL = 0.5
Input high current, IIH
VIH = 2.5 V
Detector output (DET)
Output low voltage
IOL = 0.5 mA
Internal pull-up resistor
Power dissipation (VBat = -48V, VBat2 = -17V)
P1
Open circuit state, C1, C2, C3 = 0, 0, 0
P2
P3
P4
Power supply currents (VBat = -48V)
VCC current, ICC
VBat current, IBat
VCC current, ICC
VBat current, IBat
Power supply rejection ratios
VCC to 2- or 4-wire port
VBat to 2- or 4-wire port
VBat2 to 2- or 4-wire port
Temperature guard
Junction threshold temperature, TJG
Thermal resistance
28-pin PLCC, θJP28plcc
24-pin SOIC, θJP24soic
24-pin SSOP, θJP24ssop
6
15
10
Active state, C1, C2, C3 = 0, 1, 0
Longitudinal current = 0 mA, I L=0 mA (on-hook) 60
RL = 300 Ω (off-hook)
290
RL = 500 Ω (off-hook)
145
Open circuit state
-1.5
1.2
-0.05
2.8
-1.0
30
36
40
42
45
60
-0.1
Active state
On-hook, Long Current = 0 mA
Active State
f = 1 kHz Vn = 100mV
145
39
43
55
4.0
dB
dB
dB
°C
°C/W
°C/W
°C/W
PBL 386 20/2
Notes
1.
2.
3.
4.
The overload level can be adjusted with the resistor ROV
for higher levels e.g. min 3.1 VPeak and is specified at the
two-wire port with the signal source at the four-wire receive
port.
The two-wire impedance is programmable by selection of
external component values according to:
ZTRX = ZT/|G2-4S α RSN| where:
ZTRX = impedance between the TIPX and RINGX
terminals
ZT = programming network between the VTX and RSN
terminals
G2-4S = transmit gain, nominally = 1 (or 0.5 see pin PTG)
α RSN = receive current gain, nominally = 200 (current
defined as positive flowing into the receivesumming node, RSN, and when flowing from ring to tip).
Higher return loss values can be achieved by adding a
reactive component to RT, the two-wire terminating
impedance programming resistance, e.g. by dividing RT
into two equal halves and connecting a capacitor from the
common point to ground.
The overload level can be adjusted with the resistor R OV
for higher levels e.g. min 3.1 VPeak and is specified at the
5.
6.
7.
8.
four-wire transmit port, VTX, with the signal source at the
two-wire port. Note that the gain from the two-wire port to
the four-wire transmit port is G2-4S = 1 (or 0.5 see pin PTG)
Pin PTG = Open sets transmit gain to nom. 0.0dB
Pin PTG = AGND sets transmit gain to nom. -6.02 dB
Secondary protection resistors R F and tertiary protection
resistors RP impact the insertion loss as explained in the
text, section Transmission. The specified insertion loss is
for RF = RP = 0.
The specified insertion loss tolerance does not include
errors caused by external components.
The level is specified at the two-wire port.
The two-wire idle noise is specified with the port
terminated in 600 ohms (RL) and with the four-wire receive
port grounded (ERX = 0; see figure 6).
The four-wire idle noise at VTX is specified with the twowire port terminated in 600 ohms (R L). The noise
specification is referenced to a 600 ohm programmed twowire impedance level at VTX. The four-wire receive port is
grounded (E RX = 0).
7
18
PLD
VBAT2 8
17
VCC
PSG 9
16
DET
LP 10
15
C1
DT 11
14
C2
DR
13
C3
12
26 RSN
27 AGND
NC
BGND
6
24
REF
TIPX
7
23
PLC
VBAT
8
22
POV
VBAT2
9
21
PLD
PSG
10
20
VCC
NC
11
19
NC
28-pin PLCC
12
VBAT 7
25
DET 18
TIPX 6
24-pin SOIC 20 PLC
and
19 POV
24-pin SSOP
5
LP
BGND 5
RINGX
C1 17
REF
28 VTX
21
C2 16
RINGX 4
PTG
RSN
1
22
C3 15
HP 3
2 RRLY
AGND
DR 14
23
HP
RRLY 2
3
VTX
DT 13
24
NC
PTG 1
4
PBL 386 20/2
Figure 8. Pin configuration, 24-pin SSOP, 24-pin SOIC and 28 pin PLCC package, top view.
Pin Description
Refer to figure 8.
PLCC
Symbol
Description
1
PTG
Prog. Transmit Gain. Left open transmit gain = 0.0 dB, connected to AGND transmit gain = -6.02 dB.
2
RRLY
Ring Relay driver output. The relay coil may be connected to maximum +14V.
3
HP
Connection for High Pass filter capacitor, CHP. Other end of CHP connects to TIPX.
4
NC
No internal Connection.
5
RINGX
The TIPX and RINGX pins connect to the tip and ring leads of the two-wire interface via overvoltage
protection components and ring relay (and optional test relay).
6
BGND
Battery Ground, should be tied together with AGND.
7
TIPX
The TIPX and RINGX pins connect to the tip and ring leads of the two-wire interface via overvoltage
protection components and ring relay (and optional test relay).
8
VBAT
Battery supply Voltage. Negative with respect to AGND.
9
VBAT2
An optional second (2) Battery Voltage connects to this pin.
10
PSG
Programmable Saturation Guard. The resistive part of the DC feed characteristic is not used for
PBL 386 20/2, RSG = 0 Ω.
11
NC
No internal Connection.
12
LP
Connection for Low Pass filter capacitor, CLP. Other end of CLP connects to VBAT.
13
DT
Input to the ring trip comparator. With DR more positive than DT the detector output, DET, is at logic
level low, indicating off-hook condition. The external ring trip network connects to this input.
8
PBL 386 20/2
14
DR
Input to the ring trip comparator. With DR more positive than DT the detector output, DET, is at logic
level low, indicating off-hook condition. The external ring trip network connects to this input.
15
16
17
18
C3
C2
C1
DET
C1, C2 and C3 are digital inputs (internal pull-up) controlling the SLIC operating states.
Refer to section "Operating states" for details.
19
NC
No internal Connection.
Detector output. Active low when indicating loop detection and ring trip, active high when indicating ground
key detection.
20
VCC
+5 V power supply.
21
PLD
Programmable Loop Detector threshold. The loop detection threshold is programmed by a resistor
connected from this pin to AGND.
22
POV
Programmable Overhead Voltage. If pin is left open: The overhead voltage is internally set to min 1.0 V in
Off-and On-hook. If a resistor is connected between this pin and AGND: the overhead voltage can be set to
higher values.
23
PLC
Prog. Line Current, the constant current part of the DC feed characteristic is programmed by a resistor
connected from this pin to AGND.
24
REF
A Reference, 49.9 kΩ, resistor should be connected from this pin to AGND.
25
NC
No internal Connection.
26
RSN
Receive Summing Node. 200 times the AC-current flowing into this pin equals the metallic (transversal) ACcurrent flowing from RINGX to TIPX. Programming networks for two-wire impedance and
receive gain connect to the receive summing node. A resistor should be connected from this pin to AGND.
27
AGND
Analog Ground, should be tied together with BGND.
28
VTX
Transmit vf output. The AC voltage difference between TIPX and RINGX, the AC metallic voltage, is
reproduced as an unbalanced GND referenced signal at VTX with a gain of one (or one half, see pin PTG).
The two-wire impedance programming network connects between VTX and RSN.
SLIC Operating States
State
C3
C2
C1
0
1
2
3
4
5
6
7
Table 1.
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
SLIC operating states.
SLIC operating state
Active detector
Open circuit
Ringing state
Active state
Not applicable
Not applicable
Active state
Not applicable
Not applicable
Ring trip detector (active low)
Loop detector (active low)
Ground key detector (active high)
-
9
PBL 386 20/2
TIPX
TIP
+
ZL
IL
RP
RF
+
ZTR
VTR
RHP
-
-
RING
VTX
G 2-4S
+
-
+
EL
For applications where
ZT/(αRSN·G2-4S) + 2RF + 2RP is chosen to be
equal to ZL the expression for G4-2 simplifies
to:
RF
VTX
RP
G4 −2 = −
ZT
1
⋅
Z RX 2G2 − 4S
IL
RINGX
-
ZT
Four-Wire to Four-Wire Gain
From (1), (2) and (3) with EL = 0:
Z RX
+
RSN
VRX
I L /αRSN
-
PBL 386 20/2
G4 −4 =
−
Figure 9. Simplified ac transmission circuit.
Functional Description
and Applications Information
Transmission
General
A simplified ac model of the transmission
circuits is shown in figure 9. Circuit analysis
yields:
VTR =
VTX
+ IL ⋅ (2R F + 2RP )
G2 − 4S
(1)
αRSN is the receive summing node current
to metallic loop current gain = 200.
Note that the SLICs two-wire to four-wire
gain, G2-4S, is user programmable between
two fix values. Refer to the datasheets for
values on G2-4S.
Two-Wire Impedance
To calculate ZTR, the impedance presented
to the two-wire line by the SLIC including
the fuse and protection resistors RF and RP
let:
VRX = 0.
From (1) and (2):
VTX VRX
I
+
= L
ZT
Z RX
α RSN
VTR = EL - IL · ZL
(2)
Z TR =
(3)
where:
VTX
G2-4S
VTR
EL
IL
RF
RP
ZL
ZT
ZRX
VRX
10
is a ground referenced version of the
ac metallic voltage between the TIPX
and RINGX terminals.
is the programmable SLIC two-wire
to four-wire gain (transmit direction).
See note below.
is the ac metallic voltage between tip
and ring.
is the line open circuit ac metallic
voltage.
is the ac metallic current.
is a fuse resistor.
is part of the SLIC protection.
is the line impedance.
determines the SLIC TIPX to RINGX
impedance at voice frequencies.
controls four- to two-wire gain.
is the analog ground referenced
receive signal.
ZT
+ 2RF + 2RP
α RSN ⋅ G 2− 4S
Thus with ZTR, αRSN, G2-4S, RP and RF known:
Z T = α RSN ⋅ G2− 4S ⋅ (Z TR − 2RF − 2R P )
Two-Wire to Four-Wire Gain
From (1) and (2) with VRX = 0:
G2− 4 =
VTX
=
VTR
Z T / α RSN
ZT
+ 2RF + 2RP
α RSN ⋅ G2 − 4S
Four-Wire to Two-Wire Gain
From (1), (2) and (3) with EL = 0:
G4 −2 =
−
ZT
⋅
ZRX
VTR
=
VRX
ZL
ZT
+ G2 − 4S ⋅ ( ZL + 2RF + 2R P )
α RSN
ZT
⋅
ZRX
VTX
=
VRX
G 2− 4S ⋅ ( Z L + 2RF + 2R P )
ZT
+ G2 −4 S ⋅ ( ZL + 2RF + 2RP )
α RSN
Hybrid Function
The hybrid function can easily be
implemented utilizing the uncommitted
amplifier in conventional CODEC/filter
combinations. Please, refer to figure 10.
Via impedance ZB a current proportional to
VRX is injected into the summing node of the
combination CODEC/filter amplifier. As
can be seen from the expression for the
four-wire to four-wire gain a voltage proportional to VRX is returned to VTX. This voltage
is converted by RTX to a current flowing into
the same summing node. These currents
can be made to cancel by letting:
VTX VRX
+
= 0(EL = 0 )
R TX
ZB
The four-wire to four-wire gain, G4-4, includes
the required phase shift and thus the
balance network ZB can be calculated from:
V
ZB = −RTX ⋅ RX =
VTX
ZT
+ G2 −4 S ⋅ ( ZL + 2RF + 2RP )
ZRX α RSN
R TX ⋅
⋅
ZT
G2 −4 S ⋅ ( ZL + 2RF + 2RP )
When choosing RTX, make sure the output
load of the VTX terminal is >20 kΩ.
If calculation of the ZB formula above
yields a balance network containing an
inductor, an alternate method is recommended. Contact Ericsson Components for assistance.
The PBL 386 20/2 SLIC may also be
used together with programmable CODEC/
filters. The programmable CODEC/filter
allows for system controller adjustment of
PBL 386 20/2
hybrid balance to accommodate different
line impedances without change of
hardware. In addition, the transmit and
receive gain may be adjusted. Please, refer
to the programmable CODEC/filter data
sheets for design information.
RFB
RTX
VTX
Longitudinal Impedance
A feed back loop counteracts longitudinal
voltages at the two-wire port by injecting
longitudinal currents in opposing phase.
Thus longitudinal disturbances will
appear as longitudinal currents and the
TIPX and RINGX terminals will experience
very small longitudinal voltage excursions,
leaving metallic voltages well within the
SLIC common mode range.
The SLIC longitudinal impedance per
wire, ZLoT and ZLoR, appears as typically
20Ω to longitudinal disturbances. It should
be noted that longitudinal currents may
exceed the dc loop current without disturbing the vf transmission.
Capacitors CTC and CRC
The capacitors designated CTC and CRC
in figure 12, connected between TIPX
and ground as well as between RINGX
and ground, can be used for RFI filtering.
The recommended value for CTC and
CRC is 2200 pF. Higher capacitance
values may be used, but care must be
taken to prevent degradation of either
longitudinal balance or return loss. CTC
and CRC contribute to a metallic impedance of 1/(π·f·CTC) = 1/(π·f·CRC), a TIPX to
ground impedance of1/(2·π·f·CTC) and a
RINGX to ground impedance of
1/(2·π·f·CRC).
AC - DC Separation Capacitor, CHP
The high pass filter capacitor connected
between terminals HP and TIPX provides
the separation of the ac signal from the
dc part. CHP positions the low end
frequency response break point of the ac
loop in the SLIC. Refer to table 1 for a
recommended value of CHP.
Example: A CHP value of 47 nF will
position the low end frequency response
3dB break point of the ac loop at 5.6 Hz
(f3dB) according to f3dB = 1/(2⋅π⋅RHP⋅CHP)
where RHP = 600k Ω.
High-Pass Transmit Filter
The capacitor CTX in figure 12 connected
between the VTX output and the
CODEC/filter forms, together with RTX and/
or the input impedance of a programmable
CODEC/filter, a high-pass RC filter. It is
VT
PBL
386 20/2
ZT
Combination
CODEC/Filter
ZB
Z RX
V RX
RSN
Figure 10. Hybrid function.
recommended to position the 3 dB break Battery Feed
point of this filter between 30 and 80 Hz to
The PBL 386 20/2 SLIC emulate a battery
get a faster response for the dc steps that
characteristic with current limitation
may occur at DTMF signalling.
adjustable.The open loop voltage measured
between the TIPX and RINGX terminals is
Capacitor CLP
tracking the battery voltage V Bat. The
The capacitor CLP, which connects between signalling headroom, or overhead voltage
the terminals CLP and VBAT, positions the VTRO, is programmable with a resistor ROV
high end frequency break point of the low connected between terminal POV on the
pass filter in the dc loop in the SLIC. CLP SLIC and ground. Please refer to section
together with CHP and ZT (see section Two- “Programmable overhead voltage(POV)”.
Wire Impedance) forms the total two wire The battery voltage overhead,VOH,depends
output impedance of the SLIC. The choise on the programmed signal overhead voltage
of these programmable components have VTRO . VOH defines the TIP to RING voltage
an influence on the power supply rejection at open loop conditions according to
ratio (PSRR) from VBAT to the two wire V TR (at I L = 0 mA) = |V Bat | - V OH .
side at sub-audio frequencies. At these Refer to table 2 for the typical value on
frequencies capacitor CLP also influences VOH.
the transversal to longitudinal balance in
SLIC
VOH(typ) [V]
the SLIC. Table 1 suggests a suitable value
on CLP. The typical value of the transversal
PBL 386 20/2
2.5 +VTRO
to longitudinal balance (T-L bal.) at 200Hz
is given in table 1 for the chosen value on
Table 2. Battery overhead.
CLP.
T-L bal.
RFeed
[Ω]
RSG
[kΩ]
CLP
[nF]
@ 200Hz CHP
[dB]
[nF]
2·25
0
150
-46
47
Table 1. RSG, CLP and CHP values for constant current feeding characteristics.
The current limit (reference A - C in figure
13) is adjusted by connecting a resistor,
RLC, between terminal PLC and ground
according to the equation:
RLC =
1000
ILProg + 4
where RLC is in kΩ for ILProg in mA.
For values outside table 1, please contact
Ericsson Microelectronics for assistance. A second, lower battery voltage may be
connected to the device at terminal VBAT2
to reduce short loop power dissipation.
The SLIC automatically switches between
the two battery supply voltages without need
for external control. The silent battery
11
PBL 386 20/2
switching occurs when the line voltage
passes the value
|VB2| - 40 · IL - VTRO = 3.6
For correct functionality it is important to
connect the terminal VBAT2 to the second
power supply via the diode DVB2 in figure 12.
An optional diode DBB connected between
terminal VB and the VB2 power supply, see
figure 12, will make sure that the SLIC
continues to work on the second battery
even if the first battery voltage disappears.
If a second battery voltage is not used,
VBAT2 is connected to VBAT on the SLIC
and CVB2, DBB and DVB2 are removed.
CODEC Receive Interface
The PBL 386 20/2 SLIC have got a
completely new receive interface at the
four wire side which makes it possible to
reduce the number of capacitors in the
applications and to fit both single and dual
battery feed CODECs. The RSN terminal,
connecting to the CODEC receive output
via the resistor RRX, is dc biased with +1.25V.
This makes it possible to compensate for
currents floating due to dc voltage
differences between RSN and the CODEC
output without using any capacitors. This is
done by connecting a resistor RR between
the RSN terminal and ground. With current
directions defined as in figure 14, current
summation gives:
−IRSN = IRT + IRRX + IRR =
1, 25 125
, − VCODEC
125
,
+
+
RT
RRX
RR
where VCODEC is the reference voltage of the
CODEC at the receive output.
From this equation the resistor RR can be
calculated as
125
,
RR =
, − VCODEC
1, 25 125
−IRSN −
−
RT
RRX
For the value on IRSN, see table 3.
The resistor RR has no influence on the ac
transmission.
SLIC
IRSN [µA]
PBL 386 20/2
-55
Table 3. The SLIC internal bias current with
the direction of the current defined as
positive when floating into the terminal RSN.
12
Programmable overhead voltage(POV)
Loop Monitoring Functions
With the POV function the overhead
voltage can be increased.
If the POV pin is left open the overhead
voltage is internally set to 1.1 VPeak. The
overhead voltage is equal in on-hook and
off-hook. If a resistor ROV is connected
between the POV pin and AGND, the
overhead voltage can be set to higher
values, typical values can be seen in
figure 11. The ROV and corresponding
VTRO (signal headroom) are typical values
for THD <1% and the signal frequency
1000Hz.
Observe that the 4-wire output terminal
VTX can not handle more than 3.2 VPeak.
So if the gain 2-wire to 4-wire is 0dB,
3.2 VPeak is maximum also for the 2-wire
side. Signal levels between 3.2 and 6.4
VPeak on the 2-wire side can be handled
with the PTG shorted so that the gain
G2-4S become -6.02dB. Please note that
the two-wire impedance, RR and the 4wire to 4-wire gain has to be recalculated
if the PTG is shorted.
Please note that the maximum signal
current at the 2-wire side can not be
greater than 9 mA.
The loop current, ground key and ring trip
detectors report their status through a common output, DET. The detector to be
connected to DET is selected via the three
bit wide control interface C1, C2 and C3.
Please refer to section Control Inputs for a
description of the control interface.
How to use POV:
1.
Decide what overhead
voltage(VTRO) is needed. The POV
function is only needed if the
overhead voltage exceeds 1.1 VPeak
2.
In figure 11 the corresponding ROV
for the decided VTRO can be found.
3.
If the overhead voltage exceeds
3.2 VPeak , the G2-4S gain has to be
changed to -6.02dB by connecting
the PTG pin to AGND. Please note
that the two-wire impedance, RR
and the 4-wire to 4-wire gain has to
be recalculated.
Analog Temperature Guard
The widely varying environmental
conditions in which SLICs operate may
lead to the chip temperature limitations
being exceeded. The PBL 386 20/2 SLIC
reduce the dc line current when the chip
temperature reaches approximately 145°C
and increases it again automatically when
the temperature drops. Accordingly transmission is not lost under high ambient
temperature conditions.
The detector output, DET, is forced to a
logic low level when the temperature guard
is active.
Loop Current Detector
The loop current detector is indicating that
the telephone is off hook and that current is
flowing in the loop by putting the output
DET to a logical low level when selected.
The loop current threshold value, ILTh, at
which the loop current detector changes
state is programmable by selecting the
value of resistor RLD. RLD connects between
pin PLD and ground and is calculated
according to
RLD =
500
ILTh
The current detector is internally filtered
and is not influenced by the ac signal at the
two wire side.
Ground Key Detector
The ground key detector is indicating when
the ground key is pressed (active) by putting
the output pin DET to a logical high level
when selected. The ground key detector
circuit senses the difference in TIPX and
RINGX currents. When the current at the
RINGX side exceeds the current at the
TIPX side with the threshold value the
detector is triggered. For threshold current
values, please refer to the datasheet.
Ring Trip Detector
Ring trip detection is accomplished by
connecting an external network to a
comparator in the SLIC with inputs DT and
DR. The ringing source can be balanced or
unbalanced superimposed on VB or GND.
The unbalanced ringing source may be
applied to either the ring lead or the tip lead
with return via the other wire. A ring relay
driven by the SLIC ring relay driver connects
the ringing source to tip and ring.
The ring trip function is based on a polarity
change at the comparator input when the
line goes off-hook. In the on-hook state no
dc current flows through the loop and the
voltage at comparator input DT is more
positive than the voltage at input DR. When
the line goes off-hook, while the ring relay
PBL 386 20/2
7
VTRO (VPeak)
6
5
4
3
2
1
0
0
10
20
30
40
50
60
ROV (kΩ)
Figure 11. Programmable overhead voltage (POV). RL = 600 Ω or ∞.
is energized, dc current flows and the
comparator input voltage reverses polarity.
Figure 12 gives an example of a ring trip
detection network. This network is
applicable, when the ring voltage is
superimposed on VB and is injected on the
ring lead of the two-wire port. The dc voltage
across sense resistor RRT is monitored by
the ring trip comparator input DT and DR
via the network R1, R2, R3, R4, C1 and C2.
With the line on-hook (no dc current) DT is
more positive than DR and the DET output
will report logic level high, i.e. the detector
is not tripped. When the line goes off-hook,
while ringing, a dc current will flow through
the loop including sense resistor RRT and
will cause input DT to become more
negative than input DR. This changes output DET to logic level low, i.e. tripped
detector condition. The system controller
(or line card processor) responds by deenergizing the ring relay, i.e. ring trip.
Complete filtering of the 20 Hz ac
component at terminal DT and DR is not
necessary. A toggling DET output can be
examined by a software routine to determine the duty cycle. When the DET output
is at logic level low for more than half the
time, off-hook condition is indicated.
Relay driver
Ringing State
The PBL 386 20/2 SLIC incorporates a ring
relay driver designed as open collector
(npn) with a current sinking capability of
50 mA. The drive transistor emitter is
connected to BGND. The relay driver has
an internal zener diode clamp for inductive
kick-back voltages.Care must be taken
when using the relay driver together with
relays that have high impedance.
The ring relay driver and the ring trip detector
are activated and the ring trip detector is
indicating off hook with a logic low level at
the detector output.
As the SLIC do not have any stand by state
the SLIC will remain in the active normal
state.
Control Inputs
The PBL 386 20/2 SLIC has three digital
control inputs, C1, C2 and C3.
A decoder in the SLIC interprets the control
input condition and sets up the commanded
operating state.
C1 to C3 are internal pull-up inputs.
Open Circuit State
Active States
TIPX is the terminal closest to ground and
sources loop current while RINGX is the
more negative terminal and sinks loop
current. Vf signal transmission is normal.
The loop current or the ground key detector
is activated. The loop current detector is
indicating off hook with a logic low level and
the ground key detector is indicating active
ground key with a logic high level present at
the detector output.
In the Open Circuit State the TIPX and
RINGX line drive amplifiers as well as other
circuit blocks are powered down. This
causes the SLIC to present a high
impedance to the line. Power dissipation is
at a minimum and no detectors are active.
13
PBL 386 20/2
R FB
PBL 386 20/2
C TX
KR
PTG
R TX
-
VTX
-
0
+12 V /+5V
C HP
C GG
R F2
RING
RRLY
RT
AGND
R RX
HP
RSN
NC
NC
0
CODEC/
Filter
RR
R P2
REF
R REF
BGND
PLC
R LC
TIPX
POV
R OV
VBAT
PLD
R LD
VBAT2
VCC
VCC
RINGX
+
+
RB
C RC
TIP
R F1
VB
OVP
C TC
R P1
D VB2
VB2
D BB
D VB
PBL 386 20/2
VCC
R SG
C VB2
VB
C VB
PSG
NC
NC
DET
C VCC
C LP
E RG
R1
LP
R RT
DT
R2
DR
C1
C1
PLCC 28-PIN
PACKAGE
C2
C3
C2
R3
SYSTEM CONTROL
INTERFACE
R4
SLIC No. 2 etc.
RESISTORS (Values according to IEC E96 series):
=0Ω
1% 1/10 W
RSG
RLD
= 49.9 kΩ
1% 1/10 W
= User programmable
ROV
= 38.3 kΩ
1% 1/10 W
RLC
RREF
= 49.9 kΩ
1% 1/10 W
= 64.9 kΩ
1% 1/10 W
RR
= 105 kΩ
1% 1/10 W
RT
RTX
= 24.9 kΩ
1% 1/10 W
= 22.1 kΩ
1% 1/10 W
RB
= 52.3 kΩ
1% 1/10 W
RRX
RFB
Depending on CODEC/filter
= 604 kΩ
1% 1/10 W
R1
= 604 kΩ
1% 1/10 W
R2
= 249 kΩ
1% 1/10 W
R3
= 280 kΩ
1% 1/10 W
R4
= 330 Ω
5% 2 W
RRT
1% 1/10 W (Note 1)
RP1, RP2 ≥ 10 Ω
RF1, RF2 = Line resistor, 40 Ω 1%
CAPACITORS (Values according to IEC E96 series):
CVB
= 100 nF
100 V 10%
CVB2
= 150 nF
100 V 10%
= 100 nF
10 V 10%
CVCC
= 2.2 nF
100 V 10%
CTC
CRC
= 2.2 nF
100 V 10%
= 47 nF
100 V 10%
CHP
= 150 nF
100 V 10%
CLP
CTX
= 100 nF
10 V 10%
= 220 nF
100 V 10%
CGG
= 330 nF
63 V 10%
C1
C2
= 330 nF
63 V 10%
DIODES:
= 1N4448
DVB
DVB2
= 1N4448
= 1N4448
DBB
OVP:
Secondary protection (e. g. Power Innovations
TISPPBL2). The ground terminals of the secondary
protection should be connected to the common
ground on the Printed Board Assembly with a track
as short and wide as possible, preferable a
groundplane.
Note:
1) RP1 and RP2 may be omitted if DVB is in place.
Figure 12. single-channel subscriber line interface with PBL 386 20/2 and combination CODEC/filter.
Overvoltage Protection
The PBL 386 20/2 SLIC must be protected
against overvoltages on the telephone line
caused by lightning, ac power contact and
induction. Refer to Maximum Ratings, TIPX
and RINGX terminals, for maximum
allowable continuous and transient currents
that may be applied to the SLIC.
Secondary Protection
The circuit shown in figure 12 utilizes series
resistors together with a programmable
overvoltage protector (e.g Power
Innovations TISPPBL2), serving as a
secondary protection.
The TISPPBL2 is a dual forward-conducting buffered p-gate overvoltage protector.
The protector gate references the protection
(clamping) voltage to negative supply
voltage (i.e the battery voltage,VB ).
14
As the protection voltage will track the
negative supply voltage the overvoltage
stress on the SLIC is minimized.
Positive overvoltages are clamped to ground by a diode. Negative overvoltages are
initially clamped close to the SLIC negative
supply rail voltage and the protector will
crowbar into a low voltage on-state
condition, by firing an internal thyristor.
A gate decoupling capacitor, CGG, is needed
to carry enough charge to supply a high
enough current to quickly turn on the
thyristor in the protector. CGG shall be placed
close to the overvoltage protection device.
Without the capacitor even the low
inductance in the track to the VBat supply will
limit the current and delay the activation of
the thyristor clamp.
The fuse resistors RF serve the dual
purposes of being non- destructive energy
dissipators, when transients are clamped
and of being fuses, when the line is exposed
to a power cross.
If a PTC is choosen for RF , note that it is
important to always use PTC´s in series
with resistors not sensitive to temperature,
as the PTC will act as a capacitance for fast
transients and therefore will not protect the
SLIC.
PBL 386 20/2
DC characteristics
A
C
B
I L [mA]
D
E
V TR [V]
A:
IL(@VTR=0V)=ILProg
D:
RFeed=2·25 Ω
B:
Constant current
E:
VTROpen=|VBat|-VOH
C:
ILConst(typ) = ILProg =
103
- 4·10-3
RLC
VTR=|VBat|-VOH-50·ILProg
Figure 13. Battery feed characteristics (without the protection resistors on the line).
PBL 386 20/2
VTX
DC-GND
CODEC
RT
I
IRT
RSN
IRSN
IRRX
RRX
_
+
+1.25 V
IRR
UREFcodec
RR
Figure 14. CODEC receive interface.
15
PBL 386 20/2
Power-up Sequence
No special power-up sequence is necessary
except that ground has to be present before
all other power supply voltages.
Printed Circuit Board Layout
Care in PCB layout is essential for proper
function. The components connecting to
the RSN input should be placed in close
proximity to that pin, such that no
interference is injected into the RSN pin.
Ground plane surrounding the RSN pin is
advisable.
Analog ground (AGND) should be
connected to battery ground (BGND) on
the PCB in one point.The capacitors for the
battery should be connected with short
wide leads of the same length.
Ordering Information
Package
Temp. Range
Part No.
24 pin SSOP Tape & Reel
24 pin SOIC Tube
24 pin SOIC Tape & Reel
28 pin PLCC Tube
28 pin PLCC Tape & Reel
0° - +70° C
0° - +70° C
0° - +70° C
0° - +70° C
0° - +70° C
PBL 386 20/2SHT
PBL 386 20/2SOS
PBL 386 20/2SOT
PBL 386 20/2QNS
PBL 386 20/2QNT
Information given in this data sheet is believed to be
accurate and reliable. However no responsibility is
assumed for the consequences of its use nor for any
infringement of patents or other rights of third parties
which may result from its use. No license is granted
by implication or otherwise under any patent or patent
rights of Ericsson Microelectronics AB. These
products are sold only according to Ericsson
Microelectronics AB' general conditions of sale,
unless otherwise confirmed in writing.
Specifications subject to change without
notice.
1522-PBL 386 20/2 Uen Rev. A
© Ericsson Microelectronics AB 1999
This product is an original Ericsson product
protected by US, European and other
patents.
Ericsson Microelectronics AB
SE-164 81 Kista-Stockholm, Sweden
Telephone: +46 8 757 50 00
16