POWERBOX PMP120-13

MEDICAL & MILITARY
PMP120 Series
9 6 - 1 2 0 W AT T S S I N G L E O U T P U T A C / D C M E D I C A L - P R E L I M I N A R Y
Features
• Low safety ground leakage current.
• Overvoltage protection.
• Overcurrent protection.
• 100% burn-in at full rated load.
Specifications
OPERATING
INPUT
Input Voltage
90-264Vac
Frequency
47Hz–67Hz
Input Current
1.60A (rms) for 115Vac.
0.80A (rms) for 230Vac.
Leakage current
90µA max. @ 115Vac. 60Hz.
150µA max. @ 230Vac. 50Hz.
Isolation
Input – Output: 4000VAC
Input – Ground: 1500VAC
Output – Ground: 500VAC
Inrush Current
60A @ 115V, 120A @ 230V
OUTPUT
MTBF
150,000 hrs @ 25°C
Efficiency
78-84% minimum.
ENVIRONMENTAL
Operating Temperature
0°C to 60°C
Derating
Derate to 50% at 60°C
Storage Temperature
-40°C to 85°C
Relative Humidity
5%–95% non-condensing
STANDARDS AND APPROVALS
Safety standards
UL2601-1, CSA C22.2, TUV EN60601-1
C-Tick
AS/NZS CISPR11 Group 1, Class A
EMC standards
EN60601-1-2: 2001,EN61000-3-2, -3,
EN61000-4-2, -3, -4, -5, -6, -8, -11
Output Voltage
See table
Output Current
See table
Ripple & Noise
2% peak to peak
EMI standards
EN55011 Class B, FCC Class B, VCCI Class B
Line Regulation
±0.5% maximum at full load.
MEPS compliance
TBC
Load Regulation
See table
MECHANICAL
Transient Response
Max. deviation 4% recovering to 1% within
500µs after 25% load charge
Dimensions
160x76x43.7mm
Overvoltage Protection
Provided on V1 only. Set at 110%–140% of
nominal.
Weight
0.78kgs approx.
Overcurrent Protection
All outputs protected for short circuit conditions
Temperature Coefficient
All outputs ±0.04% per °C.
Holdup Time
Typically 15ms at 110VAC.
Your dependable power partner – www.powerbox.com.au
367
MEDICAL & MILITARY
PMP120 Series
9 6 - 1 2 0 W AT T S S I N G L E O U T P U T A C / D C M E D I C A L - P R E L I M I N A R Y
Selection Table
MAX.
MODEL
OUTPUT #1
OUTPUT
NUMBER
VNOM
IMIN
IMAX
TOL
PMP120-12
12V
0A
8.0A
5%
POWER
96W
PMP120-13
15V
0A
7.0A
5%
105W
PMP120-13-1
18V
0A
6.67A
5%
120W
PMP120-13-2
19V
0A
6.32A
5%
120W
PMP120-13-3
20V
0A
6.0A
5%
120W
PMP120-14
24V
0A
5.0A
5%
120W
PMP120-16
30V
0A
4.0A
5%
120W
PMP120-17
36V
0A
3.34A
5%
120W
PMP120-18
48V
0A
2.5A
5%
120W
NOTES: Ripple and noise : Peak-to-peak with 20MHz bandwidth and 10μF tantalum capacitor in paralllel with a 0.1uF ceramic capacitor at rated line voltage and load
ranges.
Pin Chart
MODEL/PIN
PMP120-12
PMP120-13
PMP120-13-1
PMP120-13-2
PMP120-13-3
PMP120-14
PMP120-16
PMP120-17
PMP120-18
Technical Illustration
368
1
2
3
4
Return
Output +V
Return
Output +V