VECTRON TFH70E

File name: TFH70E.doc
Version 1.2
VI TELEFILTER
Filter Specification
09.03.2001
TFH 70E
1/5
1. Measurement condition :
Ambient temperature TA:
Input power level:
Terminating impedances at fc:
Q-value of matching elements:
23 °C
0 dBm.
for input:
for output:
> 50
1287 Ω  - 6,97 pF.
1227 Ω  - 7,18 pF.
2. Characteristics :
Remark: The insertion loss ae is defined as the insertion loss at the nominal frequency fN . Reference level for the relative attenuation arel of the
TFH 70E is the insertion loss. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter
attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the
frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is included in
the production tolerance scheme.
Data
Insertion loss (Reference level)
ae
Nominal frequency
fN
Centre frequency
fc at ambient temperature TA (fCAT)
typ. value
tolerance / limit
25
dB
max.
70,01
MHz
70
70,0 ± 0,09
MHz
MHz
fN .... fN ± 1,5
MHz
Pass band at ambient temperature TA: ( PB )
Amplitude ripple in O.T.R. (p-p) in :
fN ... fN ± 1,4 MHz
27
dB
0,5
dB
max.
0,8
dB
3,19
3,22
3,61
4,66
5,21
5,31
MHz
MHz
MHz
MHz
MHz
MHz
min.
min.
min.
2,8
3,0
3,5
MHz
MHz
MHz
max.
5,6
MHz
0,5
0,7
2,5
dB
dB
dB
max.
max.
max.
0,8
1
3
dB
dB
dB
dB
dB
dB
dB
dB
min.
min.
40
50
dB
dB
max.
max.
100
6
ns
°
Bandwidth in O.T.R. :
0,8
1
3
20
40
45
dB - band width
dB - band width
dB - band width
dB - band width
dB - band width
dB - band width
Relative attenuation
fN ±
fN ±
arel
fN ..... fN ± 1,4 MHz
1,4 MHz ... fN ± 1,5 MHz
1,5 MHz ... fN ± 1,75 MHz
fN ± 2,8
fN ± 5,0
fN - 65
fN + 35
fN + 63
MHz ... fN ±
MHz ... fN ±
MHz ... fN MHz ... fN +
MHz ... fN +
5,0
20
20
63
200
MHz
MHz
MHz
MHz
MHz
Group delay ( mean value in PB ):
Group delay ripple in PB (p-p):
Deviation from linear phase in PB band (p-p):
(S11) / (S22) in PB :
Triple transit attenuation compared to main signal
Crosstalk
Frequency inversion temperature ( To )
Temperature coefficient of frequency ( Tcf )
Frequency deviation of fC over temperature: * )
44...53
53...65
75...65
42...45
65...70
2,76 µs
45
ns
2,6° (r.m.s. 0,6°)
3/3
59
52
dB
dB
dB
30
°C
-0,045 ppm/K²
∆fc(Hz) = Tcf(ppm/K) x (T - To)² x fTo (MHz)
Operating temperature range ( O.T.R. )
Storage temperature range
0 °C ... + 70 °C
-40 °C ... + 85 °C
* ) fTo is reference frequency fc at frequency inversion temperature (To )
Generated:
Checked/Approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
e-mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFH70E.doc
Version 1.2
VI TELEFILTER
Filter Specification
TFH 70E
09.03.2001
2/5
3. Package :
22,5 Max.
13 max.
5,0 max.
0,64
5 6 max
0,45 Dia.
2,54 ± 0,2
6x2,54 = 15,62
7,62
Datecode:
Year+week
L
1999
M
2000
N
2001
TFH 70E
tft
M49
1
2
2,29
12,19
14
9
Pin 14
Pin 1
Pin 8
Pin 7
Pin 2, 9
Input
Input RF Return
Output
Output RF Return
Package Ground
8
4. 50 Ω matching network : ( see Application Note of TFH 70E )
L1
14
50 Ω
9
TFH
tft
1
2
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
e-mail: [email protected]
8
L2
50 Ω
70E
M49
7
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFH70E.doc
Version 1.2
VI TELEFILTER
Filter Specification
09.03.2001
TFH 70E
3/5
5. Stability characteristics :
After the following tests the filter shall meet the whole specification :
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
e-mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFH70E.doc
Version 1.2
VI TELEFILTER
Filter Specification
09.03.2001
TFH 70E
4/5
6. Air reflow temperature conditions :
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
e-mail: [email protected]
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFH70E.doc
VI TELEFILTER
Version 1.2
Filter Specification
09.03.2001
TFH 70E
5/5
7. History :
Version
Reason of changes
Name
Date
1.0
Generate Filter Specification of TFS 70V :
Dunzow W.
06.12.2000
1.1
Change name from TFS 70V to TFH70E .
Dunzow / Wall
08.03.2001
1.2
Correct detinition of insertion loss.
Correct typical filter data.
Reduce max. pass band ripple from 1 db to 0,8 dB.
Correct termination impedances .
Dunzow / Wall
09.03.2001
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
e-mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.