tfs 140G.doc Version 1.3 VI TELEFILTER Filter Specification 28.11.2000 TFS 140G - 1/5 1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc: 23 °C 0 dBm. for input: Q-value of matching elements: Source impedance: Load impedance: for output: 70 50 Ω 50 Ω 180 Ω - 16,5 pF. 200 Ω - 12,0 pF. 2. Characteristics Remark: Reference level for the relative attenuation arel of the TFS 140G is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme Data typ. value Insertion loss (Reference level) 18...18,5 dB ae fc at ambient temperature TA (fCAT) Centre frequency tolerance / limit max. 140,01 MHz 140 ± 0,06 MHz Pass band (PB) at ambient temperature TA: Amplitude ripple (p-p): Bandwidth 1 3 20 40 45 20 dB fC - 0,85 MHz.....fC + 0,85 MHz fC ..... fC ± 0,70 MHz 0,5...0,6 dB max. 1 dB at ambient temperature: dB - band width dB - band width dB - band width dB - band width dB - band width Relative attenuation fC fC ± 0,70 fC ± 1,30 fC ± 2,30 1,50 1,74 2,29 2,55 2,65...3,10 MHz MHz MHz MHz MHz min. 1,40 MHz min. 1,70 MHz max. 2,60 MHz max. 4,60 MHz dB dB dB dB max. max. min. min. arel ............ MHz ..... MHz ..... MHz ..... fC ± fC ± fC ± fC ± 0,70 0,85 2,30 40 MHz MHz MHz MHz Group delay ( mean value in PB ): Group delay ripple in PB (p-p): Deviation from linear phase in PB (p-p): Input VSWR (S11) in PB : Output VSWR (S22) in PB : Triple transit attenuation compared to main signal Crosstalk Substrate material Frequency inversion temperature ( To ) Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature: * ) 0,6 2,5 42...55 55....70 1 3 40 45 dB dB dB dB 2,54 µs 140...160 ns 2,8°...4,5° ( r.m.s. 0,8° ) max. 3,0 µs max. 200 ns max. 5° (1,6...1,8) : 1 (1,4...1,8) : 1 41...42 dB 55...65 dB max. 2 : 1 max. 2 : 1 min. 40 dB Quartz 25°...30° C -0,036...0,045 ppm/K² ∆fc(Hz) = Tcf(ppm/K) x (T - To)² x fTo (MHz) Operating temperature range Storage temperature range 0 °C ... + 70 °C - 40 °C ... + 85 °C * ) fTo is reference frequence fc at frequency inversion temperature (To ) Generated: Dunzow W.P. Checked/Approved: Dr. Bert Wall VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs 140G.doc Version 1.3 VI TELEFILTER Filter Specification 28.11.2000 TFS 140G - 2/5 3. Package D atecode: L M N ....... TF S 140 140G TFS G1 19 MM 44 P in P in P in P in P in 10 1 5 6 2 - 4, 7 - 9 Y ear+w eek 1999 2000 2001 .......... In put Input R F R eturn O utput O utput R F R eturn P ackage G round 4. 50 Ω matching networks ( see Application Note ): L1 50 Ω L3 10 9 8 7 TFS . R1 1 6 140 G M 42 2 3 4 R2 L4 50 Ω L2 5 Schem e 1 L1 10 50 Ω C1 9 8 7 TFS . R1 1 2 6 140 G M 42 3 4 5 R2 C2 = 50 Ω L2 Schem e 2 For final test we use Scheme 1. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs 140G.doc Version 1.3 VI TELEFILTER Filter Specification 28.11.2000 TFS 140G - 3/5 5. Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; 6. Packing Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Real of empty components at start: Real of empty components at start including leader: Trailer 2000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Tape (all dimensions in mm) Do W Po Do E F G (min) P2 P1 D1(min) Ao Bo t CT : : : : : : : : : : : : : 32 ± 0,3 4 ± 0,1 1,5 + 0,1 1,75 ± 0,1 14,2 ± 0,1 0,6 2 ± 0,1 12 ± 0,1 2,0 7,1 ± 0,1 19,6 ± 0, 0,3 ± 0,05 25,5 ± 0,1 Po P 2 E A o F D CT 1 W Bo G P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 W2 (max) : : N (min) : 330 32,4 +2 38,4 100 C C : 13 +0,5/-0,2 A N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs 140G.doc Version 1.3 VI TELEFILTER Filter Specification 28.11.2000 TFS 140G - 4/5 7. Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs 140G.doc Version 1.3 VI TELEFILTER Filter Specification 28.11.2000 TFS 140G - 5/5 8. History Version Reason of Changes Name Date 1.0 Generate specification according to customer requirements Modify insertion loss and triple transit attenuation according to our simulations Dunzow W. 03.05.2000 1.1 Change next parameters according to customer requirements : - filter name from TFS 140G1 to TFS 140G, - limit value of ILo from ILo = max. 19 dB to ILo = max. 20 dB, - limit value of Centre frequency from 140 ± 0,03 MHz to 140 ± 0,06 MHz, - limit value of Pass band from fC ± 0,77 MHz to fC ± 0,80 MHz, - limit value of Stop band from fC ± 1,20 MHz to fC ± 1,25 MHz, - limit value of TTS from min. 37 dB to min. 40 dB, - input and output pin positions. Add next parameters according to customer requirements: - limit value of VSWR : max. 2 : 1 , - theoretical matching network scheme. Dunzow W. 22.06.2000 1.2 Change the following parameters according to customer requirements : - limit value of Pass band from fC ± 0,8 MHz to fC ± 0,85 MHz, - Relative attenuation (3 dB) from fC ± 0,8 MHz to fC ± 0,85 MHz, - Relative attenuation (40 dB) from fC ± 1,25 MHz to fC ± 1,3 MHz, A Jaffer 13.09.2000 1.3 Generate Filter specification. Add limit value of ripple in fC - 0,7 MHz .... fC + 0,7 MHz. max. 1 dB. Dunzow W. 28.11.2000 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.