VECTRON TFS175D

Tfs175d.doc
version 1.4
VI TELEFILTER
Filter specification
29.05.2002
TFS 175 D
1/5
Measurement condition
Ambient temperature:
23 °C
Input power level:
0 dBm
Terminating impedances at fc *: input:
output:
570 Ω // -5,4 pF
500 Ω // -6,4 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 175 D is the minimum of the pass band attenuation amin. The minimum of the pass
band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies
at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 175,400 MHz without tolerance. The given
values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre
frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance
for the centre frequency fc.
Data
typ. Value
Insertion loss
(Reference level)
Nominal frequency
ae
6
fN
-
Centre frequency
fc
175,4
MHz
1 dB Passband
PB
770
kHz
Amplitude ripple in PB
p-p
-
Relative Attenuation
fN ± 5,0 MHz ....... fN ±
fN + 10,0 MHz ....... fN +
fN + 12,0 MHz ....... fN +
fN + 75,0 MHz ....... fN +
fN – 75,0 MHz ....... fN fN - 174,4MHz ....... fN -
arel
10,0
12,0
75,0
1,0
10,0
75,0
MHz
MHz
MHz
GHz
MHz
MHz
Group delay variation in PB
Limit
dB
max.
8
dB
175,4 MHz
fN ± 250
kHz
max.
1
dB
50
53
60
60
65
70
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
min.
30
50
55
50
55
50
dB
dB
dB
dB
dB
dB
60
ns
max. 200
ns
Time domain response **
5
µs
-62
dBc
min
–30
dBc
10
µs
-85
dBc
min
–50
dBc
15
µs
-85
dBc
min
–70
dBc
20
µs
-85
dBc
min
–80
dBc
40
µs
-95
dBc
min
–90
dBc
Input Power Level
-
max.
20
dBm***)
Voltage between any two terminals
-
max
30
V
Temperature coefficient of frequency Tcf
- 0,036
ppm/K
2
Operating temperature range
-
-10 °C .. +
85
°C
Storage temperature range
-
- 40 °C.. + 125
°C
Out of band intermodulation results
max.
-56
dBm
input signals at 176 and 176,6 MHz at 4 dBm
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) Values are relative to the centre of the main response lob
***) This power level is only allowed for short term operation, the max. input power for continuous operation is only max. 15 dBm
generated:
checked / approved:
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs175d.doc
version 1.4
VI TELEFILTER
Filter specification
TFS 175 D
29.05.2002
2/5
Construction and Pin Connection
(All dimensions in mm)
+0,2
+0,2
4,8 - 0,1
9,1 - 0,1
TFS 175D
P22
1
2,8 ±0,2
1
Date code
2
1
2
3
4
5
6
7
8
9
10
0,8 ±0,2
2,54 ±0,1
°
60
year + week
2000
2001
2002
M
N
P
...
5,08 ±0,2
Ground
Ground
Ground
Output
Output
Ground
Ground
Ground
Input
Input
7,01 +/- 0,2
200 Ω matching circuit:
LB-IN
C1
1
SAW
L1
1:4
C2
5
LB-OUT
C3
6
10
L2
L3
4:1
2,3,4,7,8,9
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs175d.doc
version 1.4
VI TELEFILTER
Filter specification
29.05.2002
TFS 175 D
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow): reflow possible: twice max.;
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
DIN IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer
3000
min 300 mm
min 500 mm
min 300
mm
Tape (all dimensions in mm)
W
:
16
± 0,3
Po
Do
E
:
4
± 0,1
:
:
1,5 + 0,1
1,75 ± 0,1
F
:
7,5 ± 0,1
G (min) :
0,60
P2
:
P1
:
D1(min) :
2
8
1,5
Ao
:
5,30
Bo
:
9,70
± 0,1
CT
:
13,5
± 0,1
EMBOSSED CARRIER TAPE
Do
Po
P2
E
Ao
F
D1
± 0,1
± 0,1
W
Bo
CT
G
± 0,1
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
:
W2 (max) :
330
16,40 +2,0
22,4
N (min)
:
50
C
:
13,0
± 0,5/-0.2
A
C
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs175d.doc
version 1.4
VI TELEFILTER
Filter specification
29.05.2002
TFS 175 D
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs175d.doc
version 1.4
VI TELEFILTER
Filter specification
29.05.2002
TFS 175 D
5/5
History
Version
Reason of Changes
Name
Date
1.0
Generation of “Development specification” according to customer requirements
Steiner
15.08.2001
1.1
- change of package
- max. insertion loss : 8.5 dB
Pfeiffer
30.08.2001
1.2
- terminating impedance added
- typical values added
- matching configuration added
Pfeiffer
14.01.2002
1.3
- change of package
- changing relative attenuation
- terminating impedance changed
- intermodulation added
Pfeiffer
10.04.2002
1.4
- decreasing insertion loss
- extending storage temperature range
Pfeiffer
29.05.2002
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.