FUJIKURA X3DM

X3DM Data sheet
Pre-amplified/3V Excitation/Differential
Features
.
.
.
.
.
Applications
. Industrial instrumentation
. Pressure switch, Pneumatic device
3V excitation, Battery operation available
Very small surface mountable package, Easy to mount on PCB
Volt level output
On-chip amplification and temperature compensations
Pre-calibration of offset voltage and span
. Medical device
Part number for ordering
X3DM - 050KP D S R
Terminal leads direction (See Outline Diagram)
R:
Model
X3DM
Rated pressure (Pa)
Terminal leads configuration
S : Surface mount package
Pressure type
D : Differential
DW : Differential (Bipolar pressure)
Pressure type
Differential pressure
X3DM
Model
Package configuration
Surface mount package
Measurable pressure range (kPa)
100 100
0 50
0 100
0 200
0 1000
Part number for ordering
X3DM-100KPDWSR
X3DM-050KPDSR
X3DM-100KPDSR
X3DM-200KPDSR
X3DM-001MPDSR
Specifications
Model/Rated pressure
100KPDW
050KPD
Recommended operating conditions
Pressure type
Rated pressure
100
1.020
100 100
50
0.510
0 50
100KPD
Differential pressure
100
1.020
0 100
Non-corrosive gas only
3.0 0.15
200KPD
001MPD
Unit
200
2.040
0 200
1000
10.20
0 1000
kPa
kg/cm2
kPa
Measurable pressure range
Pressure media
Excitation voltage
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
Maximum excitation voltage
6
Operating temperature
10 80
Storage temperature
20 100
Operating humidity
30 80 (No dew condensation)
Electric performances/characteristics(Excitation voltage Vcc=3.0V constant, Ambient temperature Ta=25 )
Current consumption
less than 6
Output impedance
less than 10
Source current
less than 0.1
Sink current
less than 1
Mechanical response time
2 (For the reference)
Full scale span voltage
1.5
Offset voltage 1, 2
0.5 0.075
Full scale span voltage 1, 2
2.0 0.075
Accuracy 2
5.0
Note ;
1) Output refers to pressure at pressure port 2.
2) Excluding input voltage error.
1
VDC
1.5times of rated pressure
VDC
RH
mA
mA
mA
msec
V
V
V
FS/0 50
X3DM Data sheet
Pre-amplified/3V Excitation/Differential
Outline dimensions
Unit : mm
0.15
5
Projections
4
Pressure port 2
4
5
6
0.5
Pressure port 1
15
6
10
M
Labelled faceplate
ax
8
3.5
2
2
2.54
6
0.8
3
1
3
1
1
3.3
2.5
17.5
11
14
R0.5
2
1
1
10 M
2.54
ax.
Recommended footprint for PCB
2- 1.2(Holes for projections)
Index direction
1.4
0.9
0.6
3.5
1
5.5
0.5
5
(11.5)
2
2.54 2.54
X3DM
1
Land-pads
(Unit : mm)
Zooming up the projections
3.4
11
16.6
Index
Connection diagram
Vcc(DC3V)
X3DM
Vcc
Vout
Vout
GND
C2
C1
GND
Remarks :
1) C1 : Connect 680pF capacitor within 2cm distance from
leads.
2) C2 : Connect 0.01 F or more capacitor within 2cm
distance from leads.
3) 4 and 5 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or
each other.
Transfer Function
Vout=Vs (P
+ ) (Pressure Error Temperature Error Multiplier
Vs)
Vs=3.0volts
Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage.
P=Input Pressure(kPa)
Model
pressure range
Temperature Error Multiplier=1
050KPG(D)
100KPG(D)
100KPGV
100KPGW(DW)
200KPG(D)
001MPGW(D)
115KPA
0 50kPa
0 100kPa
0
100kPa
0 +100kPa
0 200kPa
0 +1MPa
15 115kPa.abs
0.01
0.005
0.005
0.0025
0.0025
0.0025
0.005
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
2
E-mail : [email protected]
0.1667
0.1667
0.1667
0.4667
0.1667
0.1667
0.09167
Pressure Error(kPa)
2.5
5.0
5.0
10.0
10.0
50.0
5.0