MA-COM 6EHGS1-2

Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Smallest Power Entry Module with Metric Fuse Holders
GG & HG Series
UL Recognized
CSA Certified
VDE Approved
GG1
GG8
GG Series
Specifications
• Power entry module with enhanced EMI filter
• Single or dual fusing
• Two element circuit provides basic attenuation
• Available with an internal ground-circuit inductor
(C versions) to isolate equipment chassis from
power line ground at radio frequencies
• Multiple termination and mounting styles
HG Series
• Medical version of our GG Series
• Mechanically identical to GG Series
Maximum leakage current each Line to Ground:
HG Models
GG Models
@ 120 VAC 60 Hz:
2 A
.25 mA
@250 VAC 50 Hz:
5 A
.42 mA
Hipot rating (one minute):
Line to Ground:
Line to Line:
2250 VDC
1450 VDC
Rated Voltage (max.):
250 VAC
Operating Frequency:
50/60 Hz
Rated Current:
1 to 10A
Required Fuse(s):
5 x 20mm
(not included)
• Available only with dual fusing
Ordering Information
3 E GG 1 C -2
Metric Fuse Holders
1 – Single
2 – Double
Ground Circuit Inductor
Omit if none
Output Styles
1 – .250 [6.3] spade terminals
8 – Wire leads
GG or HG Series (Flange mount)
GGS or HGS Series (Snap-in mount)
Leakage current designation
E – Low leakage (<0.5 mA)
Current Rating
1, 3, 6 or 10A
Available Part Numbers
Filtered modules
1EGG1-1
3EGG1-1
6EGG1-1
10EGG1-1
1EGG1-2
3EGG1-2
6EGG1-2
10EGG1-2
1EGG8-1
3EGG8-1
6EGG8-1
10EGG8-1
1EGG8-2
3EGG8-2
6EGG8-2 10EGG8-2
1EGS1-1
3EGS1-1
6EGS1-1
10EGS1-1
1EGS1-2
3EGS1-2
6EGS1-2
10EGS1-2
Filtered modules with ground circuit inductor
1EGG1C-1 3EGG1C-1 6EGG1C-1
1EGG1C-2 3EGG1C-2 6EGG1C-2
1EGG8C-1 3EGG8C-1 6EGG8C-1
1EGG8C-2 3EGG8C-2 6EGG8C-2
Medical filter modules
1EHG1-2
3EHG1-2
6EHG1-2
10EHG1-2
1EHG8-2
3EHG8-2
6EHG8-2 10EHG8-2
1EHGS1-2 3EHGS1-2 6EHGS1-2 10EHGS1-2
166
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Smallest Power Entry Module with Metric Fuse Holders (continued)
GG & HG Series
Electrical Schematic
GG8 & HG8
LINE
LOAD
1
Blue
2
3
Green/Yellow
B
D E
Brown
3

Note 1: Second fuse only in -2 version
 Note 2: C versions only

Note 3: not present in HG versions
A

C


Accessories



 

 
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
3
Part No.
Case Styles
GG1 & HG1
GG1, GG1C & HG1
GG1C
GS1, HGS1
C
GG8, HG8
D
E
A





A
B
C



D
























E




















B





Power Inlet Filters & Power Entry Modules
Case Dimensions
Recommended Panel Cutouts
GG / HG
GS / HGS
1.14
29.0
1.24
31.5
GS1 & HGS1
1.29
32.8
1.30
33.0
D
E




C
A
1.417
36.0
B
Front or Back Mount



Front Mount Only



167
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Smallest Power Entry Module with Metric Fuse Holders (continued)
GG & HG Series
Performance Data
Typical Insertion Loss
GG & GS Models
Measured in closed 50 Ohm system
1A
3A
6A
10A
db
100
db
100
db
100
db
100
90
90
90
90
80
80
80
70
70
70
70
60
60
60
60
80
50
50
50
50
40
40
40
40
30
30
30
30
20
20
20
20
10
10
10
0
0.1
1
10
30
Frequency in MHz
0
0.1
1
3A GG1C
6A GG1C
db
100
db
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
0
10
30
Frequency in MHz
0
10
0.1
1
0
10
30
Frequency in MHz
0.01
0.1
1
10
30
Frequency in MHz
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
10
0.1
1
10
30
Frequency in MHz
0
0.1
1
10
30
Frequency in MHz
HG Models
1A
3A
6A
10A
db
100
db
100
db
100
db
100
90
90
90
90
80
80
80
80
70
70
70
70
60
60
60
60
50
50
50
50
40
40
40
40
30
30
30
30
20
20
20
20
10
10
10
0
0.1
1
10
30
Frequency in MHz
0
0.1
1
Minimum Insertion Loss
10
30
Frequency in MHz
10
0.1
1
0
10
30
Frequency in MHz
0.1
1
10
30
Frequency in MHz
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
 
  

    


 

      
Differential Mode / Symmetrical (Line to Line)









































































 

0
 


 



  











































































 

168
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com