AD1024F Series Very Low Cost, 20W DIN Rail Mount Single Output AC/DC Power Supplies Models available to 360W! Call today for details Key Features: Electrical Specifications • 20W Output Power Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. • DIN Rail Mountable Input • Universal AC Input Parameter Conditions Min. Typ. Max. Units • UL 508 Compliant Universal 100 240 VAC • EN60950 Compliant Input Voltage Range 127 370 VDC • 5, 12, 24 & 48 VDC Outputs Input Frequency 47 63 Hz • Cond./Rad. EMI Class B 110 VAC 22 A • >170 kH MTBF Inrush Current, Cold Start 220 VAC 44 A • LOW COST! Leakage Current 264 VAC 1.8 mA Output Parameter Output Voltage Accuracy Line Regulation Load Regulation (Note 1) Hold Time Ripple & Noise (20 MHz) (Note 2) Output Power Protection Transient Recovery Time (Note 3) Transient Response Deviation Temperature Coefficient Output Short Circuit Conditions Min. Typ. ±0.5 Vin = Min to Max ±1.0 Iout = 20% to 100% ±1.0 110 VAC, Full Load 10 220 VAC, Full Load 20 See Model Selection Guide Power Limit 130 2 50% Load Change 5 ±0.02 Continuous With Autorecovery Max. Units % % % mSec 160 ±0.03 % mS % %/ºC Max. Units General Parameter Isolation Voltage Isolation Resistance (Note 4) Switching Frequency Conditions Input - Output Input - FG (Frame Ground) Output - FG (Frame Ground) 500 VDC Fixed Min. 3,000 2,000 500 100 Typ. VAC M⍀ kHz 66 Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. -20 +25 -20 Free Air Convection RH, Non-condensing Ambient Max. +50 +85 Units ºC ºC 95 % Physical T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Case Size Case Material Connection 3.54 x 2.54 x 1.77 Inches (90.0 x 64.5 x 44.0 mm) Plastic Screw Terminal Reliability Specifications Parameter MTBF Safety Standards EMI Compliance EMS Immunity Compliance Conditions MIL HDBK 217F, 25ºC, Gnd Benign Min. Typ. Max. Units 170 kHours UL 1950, EN 60950, IEC 60950 Compliance to EN55011, EN55022 (CISPR22) Class B EN61000-4-2,3,4,5,6,8,11 Level 3 Model Selection Guide Model Number Rated Power (W) AD1020-05F AD1024-12F AD1024-24F AD1024-48F 20 24 24 24 Input Output Output Overvoltage Fuse Rating Ripple & Efficiency Voltage (VAC) Current (A) Protection Slow-Blow Voltage Current (A) Current (A) Noise (%, Typ) (VDC) (A) (VDC) Max) Range (mV P-P) Universal Range 115 VAC 230 VAC 100 - 240 1.0 0.5 5 4.0 0 ~ 4.0 50 7.0 78 2.0 100 - 240 1.0 0.5 12 2.0 0 ~ 2.0 100 20.0 80 2.0 100 - 240 1.0 0.5 24 1.0 0 ~ 1.0 150 40.0 83 2.0 100 - 240 1.0 0.5 48 0.5 0 ~ 0.5 250 60.0 83 2.0 Notes: 1. Load regulation is specified for a load change of 20% to 100%. 2. Ripple & noise is measured using equipment with 20 Mhz of bandwidth with the unit under test operating at rated load and a 110 VAC input. Connection to the unit is made with a 0.1 µF / 630V metalized capacitor & a 47 µF electrolytic capacitor connected in parallel. 3. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 4. Isolation resistance is given for Input/Output and Input/FG. For Output/FG., it is 50 M⍀ 5. Overload protection is power limiting. The unit recovers automatically when the fault is removed. 6. Over voltage protection is a shut down type. The unit recovers automatically when the fault is removed. 7. To mount the unit to the DIN rail, tilt the unit rearwards from the top, fitting the mount over the top of the rail. Press back on the bottom front of the unit until it locks in place on the rail. To remove the unit from the rail, pull the removal clip at the bottom rear of the unit downward with a screw driver. With the clip down, lift up on the unit from the bottom front until it clears the rail. Before installation or removal all wiring should be disconnected and the main power to the system shut off. 8. When wiring the supply, all lines should be as thick and short as possible. AWG 14 wire is recommended for the AD1024F series. 9. The units should be mounted so they are vertically orientated. Air flow (if it is provided) would optimally flow from the bottom to the top of the unit. 10. It is recommended that a fuse be used on the input of a power supply for protection. For the AD1024F series, a 250 VAC 2.0A is recommended. Derating Curve Mechanical Dimensions Connections TB 1 Pin Function 1 DC Output (+V) 2 DC Output (-V) 3 Frame Ground (FG) 4 AC/Neutral 5 AC/Live Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]