Features
■
12–100 MHz (CY7B9930V), or 24–200 MHz (CY7B9940V)
input/output operation
■
Matched pair output skew < 200 ps
■
Zero input-to-output delay
■
10 LVTTL 50% duty-cycle outputs capable of driving 50ω
terminated lines
■
Commercial temperature range with eight outputs at 200
MHz
■
Industrial temperature range with eight outputs at 200 MHz
■
3.3V LVTTL/LV differential (LVPECL), fault-tolerant and hot
insertable reference inputs
■
Multiply ratios of (1–6, 8, 10, 12)
■
Operation up to 12x input frequency
■
Individual output bank disable for aggressive power
management and EMI reduction
■
Output high impedance option for testing purposes
■
Fully integrated PLL with lock indicator
■
Low cycle-to-cycle jitter (<100 ps peak-peak)
■
Single 3.3V ± 10% supply
■
44-pin TQFP package
Functional Description
The CY7B9930V and CY7B9940V High-Speed Multifrequency
PLL Clock Buffers offer user-selectable control over system
clock functions. This multiple output clock driver provides the
system integrator with functions necessary to optimize the timing
of high performance computer or communication systems.
Ten configurable outputs can each drive terminated transmission
lines with impedances as low as 50Ω while delivering minimal and
specified output skews at LVTTL levels. The outputs are arranged
in three banks. The FB feedback bank consists of two outputs,
which allows divide-by functionality from 1 to 12. Any one of
these ten outputs can be connected to the feedback input as well
as driving other inputs.
Selectable reference input is a fault tolerance feature that allows
smooth change over to secondary clock source, when the
primary clock source is not in operation. The reference inputs are
configurable to accommodate both LVTTL or differential
(LVPECL) inputs. The completely integrated PLL reduces jitter
and simplifies board layout.
Block Diagram
FBKA
LOCK
Phase
Freq.
Detector
REFA+
REFA–
REFB+
REFB–
REFSEL
Feedback Bank
FBDS0
FBDS1
3
3
VCO
Filter
FS
Output_Mode
Control Logic
Divide
Generator
3
3
QFA0
QFA1
Divide
Matrix
2QA0
2QA1
Bank 2
2QB0
2QB1
DIS2
1QA0
1QA1
Bank 1
1QB0
1QB1
DIS1
Cypress Semiconductor Corporation
Document Number: 38-07271 Rev. *C
•
198 Champion Court
•
San Jose, CA 95134-1709
•
408-943-2600
Revised August 8, 2007
[+] Feedback
RoboClockII™ Junior,
CY7B9930V, CY7B9940V
Block Diagram Description
Divide Matrix
Phase Frequency Detector and Filter
The Divide Matrix is comprised of three independent banks: two
banks of clock outputs and one bank for feedback. Each clock
output bank has two pairs of low-skew, high fanout output buffers
([1:2]Q[A:B][0:1]), and an output disable (DIS[1:2]).
These two blocks accept signals from the REF inputs (REFA+,
REFA–, REFB+ or REFB–) and the FB input (FBKA). Correction
information is then generated to control the frequency of the
Voltage Controlled Oscillator (VCO). These two blocks, along
with the VCO, form a Phase-Locked Loop (PLL) that tracks the
incoming REF signal.
The RoboClockII™ Junior has a flexible REF input scheme.
These inputs allow the use of either differential LVPECL or single
ended LVTTL inputs. To configure as single ended LVTTL inputs,
leave the complementary pin to 1.5V), then use the other input
pin as an LVTTL input. The REF inputs are also tolerant to hot
insertion.
The REF inputs can be changed dynamically. When changing
from one reference input to the other reference input of the same
frequency, the PLL is optimized to ensure that the clock outputs
period is not less than the calculated system budget (tMIN = tREF
(nominal reference clock period) – tCCJ (cycle-to-cycle jitter) –
tPDEV (max. period deviation)) while reacquiring lock.
The feedback bank has one pair of low-skew, high fanout output
buffers (QFA[0:1]). One of these outputs may connect to the
selected feedback input (FBKA+). This feedback bank also has
two divider function selects FBDS[0:1].
The divide capabilities for each bank are shown in Table 2.
Table 2. Output Divider Function
Function
Selects
Output Divider Function
FBDS0
LOW
LOW
/1
/1
/1
LOW
MID
/1
/1
/2
LOW
HIGH
/1
/1
/3
VCO, Control Logic, and Divide Generator
MID
LOW
/1
/1
/4
The VCO accepts analog control inputs from the PLL filter block.
The FS control pin setting determines the nominal operational
frequency range of the divide by one output (fNOM) of the device.
fNOM is directly related to the VCO frequency. There are two
versions of the RoboClockII Junior, a low speed device
(CY7B9930V) where fNOM ranges from 12 MHz to 100 MHz, and
a high speed device (CY7B9940V), which ranges from 24 MHz
to 200 MHz. The FS setting for each device is shown in Table 1.
The fNOM frequency is seen on “divide-by-one” outputs.
MID
MID
/1
/1
/5
MID
HIGH
/1
/1
/6
HIGH
LOW
/1
/1
/8
HIGH
MID
/1
/1
/10
HIGH
HIGH
/1
/1
/12
Table 1. Frequency Range Select
FS[1]
CY7B9930V
CY7B9940V
fNOM (MHz)
fNOM (MHz)
Min.
Max.
Min.
Max.
LOW
12
26
24
52
MID
24
52
48
100
HIGH
48
100
96
200[2]
Bank 1
Bank 2
Feedback
Bank
FBDS1
Output Disable Description
The outputs of Bank 1 and Bank 2 can be independently put into
a HOLD OFF or high impedance state. The combination of the
Output_Mode and DIS[1:2] inputs determines the clock outputs’
state for each bank. When the DIS[1:2] is LOW, the outputs of
the corresponding bank are enabled. When the DIS[1:2] is HIGH,
the outputs for that bank are disabled to a high impedance (HI-Z)
or HOLD OFF state depending on the Output_Mode input.
Table 3 defines the disabled output functions.
Notes
1. The level to be set on FS is determined by the “nominal” operating frequency (fNOM) of the VCO. fNOM always appears on an output when the output is operating in
the undivided mode. The REF and FB are at fNOM when the output connected to FB is undivided.
2. The maximum output frequency is 200 MHz.
Document Number: 38-07271 Rev. *C
Page 2 of 11
[+] Feedback
RoboClockII™ Junior,
CY7B9930V, CY7B9940V
The HOLD OFF state is designed as a power saving feature. An
output bank is disabled to the HOLD OFF state in a maximum of
six output clock cycles from the time when the disable input
(DIS[1:2]) is HIGH. When disabled to the HOLD OFF state,
outputs are driven to a logic LOW state on its falling edge. This
ensures the output clocks are stopped without glitch. When a
bank of outputs is disabled to HI-Z state, the respective bank of
outputs go HI-Z immediately.
DIS[1:2]/FBDIS
Output Mode
HIGH/LOW
LOW
ENABLED
HIGH
HIGH
HI-Z
LOW
HIGH
HOLD-OFF
MID
X
FACTORY TEST
Lock Detect Output Description
The LOCK detect output indicates the lock condition of the
integrated PLL. Lock detection is accomplished by comparing
the phase difference between the reference and feedback
inputs. Phase error is declared when the phase difference
between the two inputs is greater than the specified device
propagation delay limit (tPD).
When in the locked state, after four or more consecutive
feedback clock cycles with phase errors, the LOCK output is
forced LOW to indicate out-of-lock state.
When in the out-of-lock state, 32 consecutive phase errorless
feedback clock cycles are required to allow the LOCK output to
indicate lock condition (LOCK = HIGH).
Document Number: 38-07271 Rev. *C
This assumes that there is activity on the selected REF input. If
there is no activity on the selected REF input then the LOCK
detect pin may not accurately reflect the state of the internal PLL.
Factory Test Mode Description
Table 3. DIS[1:2] Pin Functionality
OUTPUT_MODE
If the feedback clock is removed after LOCK has gone HIGH, a
Watchdog circuit is implemented to indicate the out-of-lock
condition after a timeout period by deasserting LOCK LOW. This
timeout period is based upon a divided down reference clock.
The device enters factory test mode when the OUTPUT_MODE
is driven to MID. In factory test mode, the device operates with
its internal PLL disconnected; the input level supplied to the
reference input is used in place of the PLL output. In TEST mode
the selected FB input must be tied LOW. All functions of the
device remain operational in factory test mode except the
internal PLL and output bank disables. The OUTPUT_MODE
input is designed as a static input. Dynamically toggling this input
from LOW to HIGH may temporarily cause the device to go into
factory test mode (when passing through the MID state).
Factory Test Reset
When in factory test mode (OUTPUT_MODE = MID), the device
is reset to a deterministic state by driving the DIS2 input HIGH.
When the DIS2 input is driven HIGH in factory test mode, all
clock outputs go to HI-Z; after the selected reference clock pin
has five positive transitions, all the internal finite state machines
(FSM) are set to a deterministic state. The deterministic state of
the state machines depends on the configurations of the divide
selects and frequency select input. All clock outputs stay in high
impedance mode and all FSMs stay in the deterministic state
until DIS2 is deasserted. When DIS2 is deasserted (with
OUTPUT_MODE still at MID), the device reenters factory test
mode.
Page 3 of 11
[+] Feedback
RoboClockII™ Junior,
CY7B9930V, CY7B9940V
Pin Definitions
VCCQ
FBKA
GND
GND
QFA1
VCCN
QFA0
GND
FBDS0
FBDS1
LOCK
44-Pin TQFP
44 43 42 41 40 39 38 37 36 35 34
GND
1
33
VCCQ
2QB1
2
32
REFA+
VCCN
3
31
REFA –
2QB0
4
30
REFSEL
GND
5
29
REFB–
GND
6
28
REFB+
2QA1
7
27
FS
VCCN
8
26
GND
2QA0
9
25
VCCQ
GND
10
24
DIS2
GND
11
23
DIS1
CY7B9930V/40V
I/O
Type
Output_Mode
GND
1QB1
VCCN
1QB0
GND
GND
1QA1
VCCN
GND
Name
1QA0
12 13 14 15 16 17 18 19 20 21 22
Description
FBKA
Input
LVTTL
Feedback Input.
REFA+, REFA–
REFB+, REFB–
Input
LVTTL/
LVDIFF
Reference Inputs: These inputs operate as either differential PECL or single ended TTL
reference inputs to the PLL. When operating as a single ended LVTTL input, leave the
complementary input must be left open.
REFSEL
Input
LVTTL
Reference Select Input: The REFSEL input controls reference input configuration. When
LOW, it uses the REFA pair as the reference input. When HIGH, it uses the REFB pair as
the reference input. This input has an internal pull down.
FS[3]
Input
3 Level
Input
Frequency Select: Set this input according to the nominal frequency (fNOM). See Table 1.
FBDS[0:1][3]
Input
3 Level
Input
Feedback Divider Function Select. These inputs determine the function of the QFA0 and
QFA1 outputs. See Table 2.
DIS[1:2]
Input
LVTTL
Output Disable: Each input controls the state of the respective output bank. When HIGH,
the output bank is disabled to the “HOLD OFF” or “HI-Z” state; the disable state is determined by OUTPUT_MODE. When LOW, the [1:4]Q[A:B][0:1] is enabled. See Table 3.
These inputs each have an internal pull down.
LOCK
Output
LVTTL
PLL Lock Indicator: When HIGH, this output indicates that the internal PLL is locked to
the reference signal. When LOW, the PLL is attempting to acquire lock.
Output_Mode[3]
Input
3 Level
Input
Output Mode: This pin determines the clock outputs’ disable state. When this input is HIGH,
the clock outputs disable to high impedance (HI-Z). When this input is LOW, the clock
outputs disables to “HOLD OFF” mode. When in MID, the device enters factory test mode.
QFA[0:1]
Output
LVTTL
Clock Feedback Output: This pair of clock outputs connects to the FB input. These outputs
have numerous divide options. The function is determined by the setting of the FBDS[0:1]
pins.
[1:2]Q[A:B][0:1]
Output
LVTTL
Clock Output.
VCCN
PWR
Output Buffer Power: Power supply for each output pair.
VCCQ
PWR
Internal Power: Power supply for the internal circuitry.
GND
PWR
Device Ground.
Note
3. For all tri-state inputs, HIGH indicates a connection to VCC, LOW indicates a connection to GND, and MID indicates an open connection. Internal termination circuitry
holds an unconnected input to VCC/2.
Document Number: 38-07271 Rev. *C
Page 4 of 11
[+] Feedback
RoboClockII™ Junior,
CY7B9930V, CY7B9940V
Absolute Maximum Conditions
Static discharge voltage................................................. >2000V
MIL-STD-883, Method 3015)
Exceeding the maximum ratings may impair the useful life of the
device. These user guidelines are not tested.
Latch up current......................................................... >±200 mA
Storage temperature ...........................................−40°C to +125°C
Operating Range
Ambient Temperature with power applied ........−40°C to +125°C
Range
Supply voltage to ground potential ........................−0.5V to +4.6V
Commercial
DC input voltage ............................................... −0.3V to VCC+0.5V
Output current into outputs (LOW) ...................................40 mA
Ambient Temperature
VCC
0°C to +70°C
3.3V ±10%
–40°C to +85°C
3.3V ±10%
Industrial
Electrical Characteristics Over the Operating Range
Parameter
Description
Test Conditions
Min.
Max.
Unit
VCC = Min., IOH = –30 mA
2.4
–
V
IOH = –2 mA, VCC = Min.
2.4
–
V
VCC = Min., IOL= 30 mA
–
0.5
V
LVTTL Compatible Output Pins (QFA[0:1], [1:4]Q[A:B][0:1], LOCK)
VOH
LVTTL HIGH voltage QFA[0:1], [1:2]Q[A:B][0:1]
VOL
LVTTL LOW voltage QFA[0:1], [1:2]Q[A:B][0:1]
IOZ
High impedance state leakage current
LOCK
LOCK
IOL= 2 mA, VCC = Min.
–
0.5
V
–100
100
μA
LVTTL Compatible Input Pins (FBKA, REFA±, REFB±, REFSEL, DIS[1:2])
VIH
LVTTL Input HIGH
FBKA+, REF[A:B]±
Min. < VCC < Max.
REFSEL, DIS[1:2]
2.0
VCC+0.3
V
2.0
VCC+0.3
V
–0.3
0.8
V
VIL
LVTTL Input LOW
–0.3
0.8
V
II
LVTTL VIN >VCC
FBKA+, REF[A:B]±
VCC = GND, VIN = 3.63V
–
100
μA
IlH
LVTTL Input HIGH
Current
FBKA+, REF[A:B]±
VCC = Max., VIN = VCC
–
500
μA
REFSEL, DIS[1:2]
VIN = VCC
–
500
μA
LVTTL Input LOW
Current
FBKA+, REF[A:B]±
VCC = Max., VIN = GND
–500
–
μA
–500
–
μA
Min. < VCC < Max.
0.87*VCC
–
V
Min. < VCC < Max.
0.47*VCC
0.53*VCC
V
0.13*VCC
V
FBKA+, REF[A:B]±
Min. < VCC < Max.
REFSEL, DIS[1:2]
IlL
REFSEL, DIS[1:2]
3-Level Input Pins (FBDS[0:1], FS, Output_Mode)
VIHH
Three level input HIGH[4]
MID[4]
VIMM
Three level input
VILL
Three level input LOW[4]
IIHH
Three level input
HIGH current
IIMM
IILL
Min. < VCC < Max.
VIN = VCC
–
200
μA
Three level input MID Three level input pins
current
VIN = VCC/2
–50
50
μA
Three level input
LOW current
VIN = GND
–200
–
μA
Three level input pins
Three level input pins
LVDIFF Input Pins (REF[A:B]±)
VDIFF
Input differential voltage
400
VCC
mV
VIHHP
Highest input HIGH voltage
1.0
VCC
V
VILLP
Lowest input LOW voltage
GND
VCC – 0.4
V
VCOM
Common mode range (crossing voltage)
0.8
VCC
V
Note
4. These inputs are normally wired to VCC, GND, or left unconnected (actual threshold voltages vary as a percentage of VCC). Internal termination resistors hold the
unconnected inputs at VCC/2. If these inputs are switched, the function and timing of the outputs may glitch and the PLL may require an additional tLOCK time before
all data sheet limits are achieved.
Document Number: 38-07271 Rev. *C
Page 5 of 11
[+] Feedback
RoboClockII™ Junior,
CY7B9930V, CY7B9940V
Electrical Characteristics Over the Operating Range
Parameter
(continued)
Description
Test Conditions
Min.
Max.
Unit
VCC = Max., fMAX[5]
–
200
mA
–
200
mA
Operating Current
ICCI
ICCN
Internal operating
current
CY7B9930V
Output current
dissipation/pair[6]
CY7B9930V
CY7B9940V
VCC = Max.,
CLOAD = 25 pF,
RLOAD = 50Ω at VCC/2,
fMAX
CY7B9940V
–
40
mA
–
50
mA
Min.
Max.
Unit
–
5
pF
Capacitance
Parameter
CIN
Description
Input capacitance
Test Conditions
TA = 25°C, f = 1 MHz, VCC = 3.3V
Switching Characteristics
Over the Operating Range[7, 8, 9, 10, 11]
Parameter
fin
fout
CY7B9930/40V-2 CY7B9930/40V-5
Description
Clock input frequency
Clock input frequency
Unit
Min.
Max.
Min.
Max.
CY7B9930V
12
100
12
100
MHz
CY7B9940V
24
200
24
200
MHz
CY7B9930V
12
100
12
100
MHz
CY7B9940V
24
200
24
200
MHz
skew[12, 13]
tSKEWPR
Matched pair
–
185
–
185
ps
tSKEWBNK
Intrabank skew[12, 13]
–
200
–
250
ps
tSKEW0
Output-Output skew (same frequency and phase, rise to rise, fall
to fall)[12, 13]
–
250
–
550
ps
tSKEW1
Output-Output skew (same frequency and phase, other banks at
different frequency, rise to rise, fall to fall)[12, 13]
–
250
–
650
ps
tCCJ1-3
Cycle-to-cycle jitter (divide by 1 output frequency,
FB = divide by 1, 2, 3)
–
150
–
150
ps PeakPeak
tCCJ4-12
Cycle-to-cycle jitter (divide by 1 output frequency,
FB = divide by 4, 5, 6, 8, 10, 12)
–
100
–
100
ps PeakPeak
tPD
Propagation delay, REF to FB Rise
–250
250
–500
500
ps
tPDDELTA
Propagation delay difference between two devices[14]
–
200
200
ps
tREFpwh
REF input (pulse width HIGH)[15]
2.0
–
2.0
–
ns
tREFpwl
REF input (pulse width LOW)[15]
2.0
–
2.0
–
ns
time[16]
tr/tf
Output rise/fall
0.15
2.0
0.15
2.0
ns
Notes
5. ICCI measurement is performed with Bank1 and FB Bank configured to run at maximum frequency (fNOM = 100 MHz for CY7B9930V, fNOM = 200 MHz for CY7B9940V),
and all other clock output banks to run at half the maximum frequency. FS and OUTPUT_MODE are asserted to the HIGH state.
6. This is dependent upon frequency and number of outputs of a bank being loaded. The value indicates maximum ICCN at maximum frequency and maximum load of
25 pF terminated to 50Ω at VCC/2.
7. This is for non-three level inputs.
8. Assumes 25 pF Max. Load Capacitance up to 185 Mhz. At 200 MHz the max load is 10 pF.
9. Both outputs of pair must be terminated, even if only one is being used.
10. Each package must be properly decoupled.
11. AC parameters are measured at 1.5V, unless otherwise indicated.
12. Test Load CL= 25 pF, terminated to VCC/2 with 50Ω.
13. SKEW is defined as the time between the earliest and the latest output transition among all outputs for which the same phase delay has been selected when all outputs
are loaded with 25 pF and properly terminated up to 185 MHz. At 200 MHz the max load is 10 pF.
14. Guaranteed by statistical correlation. Tested initially and after any design or process changes that may affect these parameters.
15. Tested initially and after any design or process changes that may affect these parameters.
16. Rise and fall times are measured between 2.0V and 0.8V.
Document Number: 38-07271 Rev. *C
Page 6 of 11
[+] Feedback
RoboClockII™ Junior,
CY7B9930V, CY7B9940V
Switching Characteristics
Over the Operating Range[7, 8, 9, 10, 11] (continued)
Parameter
CY7B9930/40V-2 CY7B9930/40V-5
Description
Min.
Max.
Min.
Max.
Unit
tLOCK
PLL lock time from power up
–
10
–
10
ms
tRELOCK1
PLL relock time (from same frequency, different phase) with
stable power supply
–
500
–
500
μs
tRELOCK2
PLL Relock Time (from different frequency, different phase) with
Stable Power Supply[17]
–
1000
–
1000
μs
tODCV
Output duty cycle deviation from 50%[11]
–1.0
1.0
–1.0
1.0
ns
tPWH
Output HIGH time deviation from 50%[18]
–
1.5
–
1.5
ns
tPWL
Output LOW time deviation from
50%[18]
–
2.0
–
2.0
ns
tPDEV
Period deviation when changing from reference to reference[19]
–
0.025
–
0.025
UI
1.0
10
1.0
10
ns
0.5
14
0.5
14
ns
ACTIVE[12, 20]
tOAZ
DIS[1:2] HIGH to output high impedance from
tOZA
DIS[1:2] LOW to output ACTIVE from output is high
impedance[20, 21]
AC Test Loads and Waveform
See note. [22]
3.3V
R1
OUTPUT
For all other outputs
R1 = 100Ω
CL
R2 = 100Ω
CL < 25 pF up to 185 MHz
10 pF from 185 to 200 MHz
(Includes fixture and
probe capacitance)
For LOCK output only
R1 = 910Ω
R2 = 910 Ω
CL < 30 pF
R2
(a) LVTTL AC Test Load
3.3V
2.0V
0.8V
GND
< 1 ns
2.0V
0.8V
< 1 ns
(b) TTL Input Test Waveform
Notes
17. fNOM must be within the frequency range defined by the same FS state.
18. tPWH is measured at 2.0V. tPWL is measured at 0.8V.
19. UI = Unit Interval. Examples: 1 UI is a full period. 0.1 UI is 10% of period.
20. Measured at 0.5V deviation from starting voltage.
21. For tOZA minimum, CL = 0 pF. For tOZA maximum, CL= 25 pF to 18 MHz, 10 pF from 185 to 200 MHz.
22. These figures are for illustration only. The actual ATE loads may vary.
Document Number: 38-07271 Rev. *C
Page 7 of 11
[+] Feedback
RoboClockII™ Junior,
CY7B9930V, CY7B9940V
AC Timing Diagrams
See note. [11]
tREFpwl
QFA0 or
[1:4]Q[A:B]0
tREFpwh
REF
t SKEWPR
t SKEWPR
t PWH
tPD
t PWL
2.0V
FB
QFA1 or
[1:4]Q[A:B]1
0.8V
tCCJ1-3,4-12
Q
[1:4]QA[0:1]
t SKEWBNK
t SKEWBNK
[1:4]QB[0:1]
REF TO DEVICE 1 and 2
tODCV
tODCV
tPD
Q
FB DEVICE1
tPDELTA
tPDELTA
t SKEW0,1
t SKEW0,1
Other Q
FB DEVICE2
Document Number: 38-07271 Rev. *C
Page 8 of 11
[+] Feedback
RoboClockII™ Junior,
CY7B9930V, CY7B9940V
Ordering Information
Propagation
Delay (ps)
Max. Speed
(MHz)
500
100
Ordering Code
CY7B9930V-5AC
[23]
[23]
500
100
CY7B9930V-5AI
500
200
CY7B9940V-5AC
[23]
Package Type
Operating Range
44-Lead Thin Quad Flat Pack
Commercial
44-Lead Thin Quad Flat Pack
Industrial
44-Lead Thin Quad Flat Pack
Commercial
44-Lead Thin Quad Flat Pack
Industrial
500
200
CY7B9940V-5AI
250
100
CY7B9930V-2AC [23]
44-Lead Thin Quad Flat Pack
250
200
CY7B9940V-2AC
44-Lead Thin Quad Flat Pack
250
100
CY7B9930V-2AI [23]
44-Lead Thin Quad Flat Pack
200
CY7B9940V-2AI
[23]
44-Lead Thin Quad Flat Pack
500
100
CY7B9930V-5AXC
44-Lead Thin Quad Flat Pack
Commercial
500
100
CY7B9930V-5AXCT
44-Lead Thin Quad Flat Pack–Tape and Reel
Commercial
500
200
CY7B9940V-5AXC
44-Lead Thin Quad Flat Pack
Commercial
500
200
CY7B9940V-5AXCT
44-Lead Thin Quad Flat Pack–Tape and Reel
500
200
CY7B9940V-5AXI
44-Lead Thin Quad Flat Pack
500
200
CY7B9940V-5AXIT
44-Lead Thin Quad Flat Pack–Tape and Reel
250
200
CY7B9940V-2AXC
44-Lead Thin Quad Flat Pack
250
200
CY7B9940V-2AXCT
44-Lead Thin Quad Flat Pack–Tape and Reel
250
200
CY7B9940V-2AXI
44-Lead Thin Quad Flat Pack
250
200
CY7B9940V-2AXIT
44-Lead Thin Quad Flat Pack–Tape and Reel
250
Commercial
Industrial
Pb-free
Industrial
Commercial
Industrial
Note
23. It is a obsolete device.
Document Number: 38-07271 Rev. *C
Page 9 of 11
[+] Feedback
RoboClockII™ Junior,
CY7B9930V, CY7B9940V
Package Diagrams
44-Lead Thin Plastic Quad Flat Pack A44
,EAD4HIN0LASTIC1UAD&LATPACK88MM
¼31
',0(16,216,10,//,0(7(56
¼31
²-).
¼
2-).
-!8
34!.$/&&
-).
-!8
'!5'%0,!.%
2-).
-).
²
-).
¼
2%&
"3#
$%4!),
!
#
²¼²
8
3%!4).'0,!.%
-!8
¼
-!8
3%%$%4!),
!
RoboClockII is a trademark of Cypress Semiconductor.
Document Number: 38-07271 Rev. *C
Page 10 of 11
[+] Feedback
RoboClockII™ Junior,
CY7B9930V, CY7B9940V
Document History Page
Document Title: RoboClockII™ Junior, CY7B9930V, CY7B9940V High Speed Multifrequency PLL Clock Buffer
Document Number: 38-07271
REV.
ECN NO.
Issue Date
Orig. of
Change
**
110536
12/02/01
SZV
Change from Spec number: 38-01141
*A
115109
7/03/02
HWT
Add 44TQFP package for both CY7B9930/40V – Industrial Operating Range
*B
128463
7/29/03
RGL
Added clock input frequency (fin) specifications in the switching characteristics
table.
Added Min. values for the clock output frequency (fout) in the switching characteristics table.
*C
1346903
8/8/07
Description of Change
WWZ/VED/ Update the ordering info to reflect the current status and Pb-free part numbers.
ARI
Implemented new template. Updated the package diagram.
© Cypress Semiconductor Corporation, 2007. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use of any
circuitry other than circuitry embodied in a Cypress product. Nor does it convey or imply any license under patent or other rights. Cypress products are not warranted nor intended to be used for medical,
life support, life saving, critical control or safety applications, unless pursuant to an express written agreement with Cypress. Furthermore, Cypress does not authorize its products for use as critical
components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress products in life-support systems
application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress against all charges.
Any Source Code (software and/or firmware) is owned by Cypress Semiconductor Corporation (Cypress) and is protected by and subject to worldwide patent protection (United States and foreign),
United States copyright laws and international treaty provisions. Cypress hereby grants to licensee a personal, non-exclusive, non-transferable license to copy, use, modify, create derivative works of,
and compile the Cypress Source Code and derivative works for the sole purpose of creating custom software and or firmware in support of licensee product to be used only in conjunction with a Cypress
integrated circuit as specified in the applicable agreement. Any reproduction, modification, translation, compilation, or representation of this Source Code except as specified above is prohibited without
the express written permission of Cypress.
Disclaimer: CYPRESS MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Cypress reserves the right to make changes without further notice to the materials described herein. Cypress does not
assume any liability arising out of the application or use of any product or circuit described herein. Cypress does not authorize its products for use as critical components in life-support systems where
a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress’ product in a life-support systems application implies that the manufacturer
assumes all risk of such use and in doing so indemnifies Cypress against all charges.
Use may be limited by and subject to the applicable Cypress software license agreement.
Document Number: 38-07271 Rev. *C
Revised August 8, 2007
Page 11 of 11
PSoC Designer™, Programmable System-on-Chip™, and PSoC Express™ are trademarks and PSoC® is a registered trademark of Cypress Semiconductor Corp. All other trademarks or registered
trademarks referenced herein are property of the respective corporations.
Purchase of I2C components from Cypress or one of its sublicensed Associated Companies conveys a license under the Philips I2C Patent Rights to use these components in an I2C system, provided
that the system conforms to the I2C Standard Specification as defined by Philips.
All products and company names mentioned in this document may be the trademarks of their respective holders.
[+] Feedback