Filename: tfs 72a.doc Version 1.2 VI TELEFILTER 25.10.2006 Filter specification TFS 72A 1/5 rMeasurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 550 Ω || -33 pF 310 Ω || -45 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 72A is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The nominal frequency fN is fixed at 72,54. The values for relative attenuation are guaranteed at ambient temperature. The frequency shift of the filter over temperature defined by the temperature coefficient of frequency Tcf is not included in the production tolerance scheme. Data typ. value Insertion loss (reference level) ae Nominal frequency fN Pass band PB Pass band ripple p-p 10,5 dB tolerance / limit max. 14,4 72,54 fN max. ± 1,85 1,5 dB MHz MHz 0,8 dB dB 4,2 4,7 5,9 6,5 MHz MHz MHz MHz max. max. 6,0 7,0 dB min. 48,0 dB max. 1,5 dB 45 38 36 37 36 48 50 55 dB dB dB dB dB dB dB dB min. min. min. min. min. min. min. min. 34,0 36,0 34,0 28,0 34,0 42,0 44,0 48,0 dB dB dB dB dB dB dB dB 190 ns Bandwidth 1,5 3 15 30 dB dB dB dB 91,53 arel MHz 74,39 arel MHz Mean relative attenuation 86,47 MHz ... Relative attenuation 70,69 MHz ... 50,00 65,00 66,48 77,30 78,60 86,47 91,53 95,21 MHz MHz MHz MHz MHz MHz MHz MHz ... ... ... ... ... ... ... ... 65,00 66,48 68,08 78,60 86,47 91,53 95,21 100,00 Group delay ripple in PB MHz MHz MHz MHz MHz MHz MHz MHz p-p 55 0,8 - Input power level - max. Permissible DC voltage - max. Operating temperature range OTR Storage temperature range Temperature coefficient of frequency TCf ** 10 0 - -40 °C ... + 85 °C - -40 °C ... + 85 °C -26 ppm/K MHz MHz dBm V - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆fc(Hz) = TCf(ppm/K) x (T - To) x fTo (MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 72a.doc Version 1.2 VI TELEFILTER 25.10.2006 Filter specification TFS 72A 2/5 0 0 -8 -1 -16 -2 -24 -3 -32 -4 magnitude in dB magnitude in dB Filter characteristic -40 -48 -5 -6 -56 -7 -64 -8 -72 -9 -80 54.5 58.1 61.7 65.3 68.9 72.5 76.1 frequency in MHz 79.7 83.3 86.9 90.5 -10 69.5 70.1 70.7 71.3 71.9 72.5 73.1 frequency in MHz 73.7 74.3 74.9 75.5 Construction and pin connection (All dimensions in mm) S 72A ● U43 1 2 3 4 5 6 7 8 9 10 Ground Ground Ground Output Output Ground Ground Ground Input Input Date code: U V W ... Year + week 2006 2007 2008 Date code 200 Ohm Test circuit Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 72a.doc Version 1.2 VI TELEFILTER 25.10.2006 Filter specification TFS 72A 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction P1 Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 7,50 ± 0,1 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 5,50 ± 0,1 Bo : 7,50 ± 0,1 Ct : 13,5 ± 0,1 t PIN Marker Po P2 W G Ct Bo F G E Do Ko Date Code Typ D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 50 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 72a.doc Version 1.2 VI TELEFILTER 25.10.2006 Filter specification TFS 72A 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 72a.doc VI TELEFILTER Version 1.2 Filter specification 25.10.2006 TFS 72A 5/5 History Version Reason of Changes Name Date 1.0 - generation of development specification Strehl 14.06.2005 1.1 - generated filter specification - added terminating impedances - added typical values - added filter characteristic - added test circuit - changed construction and pin connection Chilla 28.04.2006 1.2 - changed terminating impedances - changed remark - changed construction and pin connection - changed test circuit Chilla 25.10.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.