Filename: tfs 130a.doc Version 1.6 VI TELEFILTER 09.11.2005 Filter specification TFS 130A 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 470 Ω || -12,9 pF 470 Ω || -12,9 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 130A is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 130,38 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss (reference level) ae 6,6 Nominal frequency fN - Passband - Pass band ripple 0,5 max. 8 130,38 fN dB ± 0,665 max. dB MHz MHz 1 dB arel Relative attenuation fN dB tolerance / limit … fN ± 0,665 MHz - max. 1 dB MHz … fN - 5,75 MHz 45 dB min. 40 dB 5,75 MHz … fN + 9,87 MHz 45 dB min. 40 dB + 9,87 MHz … fN + 10,87 MHz 41 dB min. 38 dB + 10,87 MHz … fN + 20 MHz 46 dB min. 38 dB 770 ns 770 50 ns fN - fN + fN fN 20 Group delay mean value in PB Group delay ripple within PB Deviation from linear phase within PB VSWR within PB Operating temperature range OTR Temperature coefficient of frequency TCf ** ns - 0,7 ° rms max. 2,5 ° rms 1,5 : 1 max. 2 : 1 - - 30 °C ... + 80 °C - Storage temperature range ± 10 -19 - 40 °C ... + 85 °C ppm/K - *) The terminating impedances depend on parasites and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 130a.doc Version 1.6 VI TELEFILTER 09.11.2005 Filter specification TFS 130A 2/5 0 1.155 -1 1.11 -20 -2 1.065 -30 -3 1.02 -4 0.975 -5 0.93 -6 0.885 -70 -7 0.84 -80 -8 0.795 -90 -9 0.75 -40 -50 -60 -100 123.4 124.8 126.2 127.6 129 130.4 131.8 133.2 134.6 frequency in MHz 136 137.4 delay in µs 0 -10 magnitude in dB magnitude in dB Filter characteristic 0.705 -10 128.4 128.8 129.2 129.6 130 130.4 130.8 131.2 131.6 132 132.4 frequency in MHz Construction and pin connection (All dimensions in mm) ● 70799 tft T45 3 Date code 2 Max. 1 1 5,2 Max. 2,54 ±0,2 7,2 Max. 2,54 ±0,2 1 1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Output RF Return Output Ground Ground Ground Ground Input RF Return Input Ground Ground Date code: T U V ... Year + week 2005 2006 2007 0,80 50 Ω test circuit 10 L1 4 L2 SAW C2 C1 3 9 1, 2, 5, 6, 7, 8, 11, 12 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 130a.doc Version 1.6 VI TELEFILTER 09.11.2005 Filter specification TFS 130A 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction P1 Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 7,50 ± 0,1 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 5,50 ± 0,1 Bo : 7,50 ± 0,1 Ct : 13,5 ± 0,1 t Po PIN Marker P2 W G Ct Bo F G E Do Ko Date Code Typ D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 50 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 130a.doc Version 1.6 VI TELEFILTER 09.11.2005 Filter specification TFS 130A 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile pre-heating periods main-heating periods 150 °C - 170 °C over 200 °C 60 sec. - 90 sec. 20 sec. - 25 sec. Name: Temperature: Time: peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 130a.doc VI TELEFILTER Version 1.6 Filter specification 09.11.2005 TFS 130A 5/5 History Version Reason of Changes Name Date 1.0 Generation of preliminary specification according to customer requirements. Dunzow W. 03.05.1999 1.1 Generation of filter specification. Add typical values. Dunzow W. 18.06.1999 1.2 Correct termination impedances. Change drawing of matching networks. Change tolerance values of mean value of group delay. Change marking of package. Dunzow W. 17.05.2002 1.3 Change marking of package. Springfeldt M. 30.03.2004 1.4 - labelling changed - filter characteristic added - change remark - remove centre frequency - Change tolerance values of mean value of group delay back to version 1.1 Pfeiffer 17.08.2004 1.5 - labelling corrected Steiner 03.09.2004 1.6 - pinning corrected Pfeiffer 09.11.2005 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.