Filter specification
TFS 130A
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
470 Ω || -12,9 pF
470 Ω || -12,9 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 130A is the minimum of the pass band attenuation. This value is defined as the insertion loss
ae. The nominal frequency fN is fixed at 130,38 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating
temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
Insertion loss
(reference level)
ae
6,6
Nominal frequency
fN
-
Passband
-
Pass band ripple
0,5
max.
8
130,38
fN
dB
± 0,665
max.
dB
MHz
MHz
1
dB
arel
Relative attenuation
fN
dB
tolerance / limit
… fN
±
0,665
MHz
-
max.
1
dB
MHz … fN
-
5,75
MHz
45
dB
min.
40
dB
5,75
MHz … fN
+
9,87
MHz
45
dB
min.
40
dB
+
9,87
MHz … fN
+
10,87
MHz
41
dB
min.
38
dB
+
10,87
MHz … fN
+
20
MHz
46
dB
min.
38
dB
770
ns
770
50
ns
fN
-
fN
+
fN
fN
20
Group delay
mean value in PB
Group delay ripple within PB
Deviation from linear phase within PB
VSWR within PB
Operating temperature range
OTR
Temperature coefficient of frequency
TCf **
ns
-
0,7
° rms
max.
2,5
° rms
1,5
: 1
max.
2
: 1
-
- 30 °C ... + 80 °C
-
Storage temperature range
± 10
-19
- 40 °C ... + 85 °C
ppm/K
-
*) The terminating impedances depend on parasites and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 130a.doc
Version 1.6
VI TELEFILTER
09.11.2005
Filter specification
TFS 130A
2/5
0
1.155
-1
1.11
-20
-2
1.065
-30
-3
1.02
-4
0.975
-5
0.93
-6
0.885
-70
-7
0.84
-80
-8
0.795
-90
-9
0.75
-40
-50
-60
-100
123.4 124.8 126.2 127.6
129 130.4 131.8 133.2 134.6
frequency in MHz
136
137.4
delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
0.705
-10
128.4 128.8 129.2 129.6 130 130.4 130.8 131.2 131.6 132 132.4
frequency in MHz
Construction and pin connection
(All dimensions in mm)
● 70799
tft T45
3
Date code
2 Max.
1
1
5,2 Max.
2,54 ±0,2
7,2 Max.
2,54 ±0,2
1
1
2
3
4
5
6
7
8
9
10
11
12
Ground
Ground
Output RF Return
Output
Ground
Ground
Ground
Ground
Input RF Return
Input
Ground
Ground
Date code:
T
U
V
...
Year + week
2005
2006
2007
0,80
50 Ω test circuit
10
L1
4
L2
SAW
C2
C1
3
9
1, 2, 5, 6, 7, 8, 11, 12
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 130a.doc
Version 1.6
VI TELEFILTER
09.11.2005
Filter specification
TFS 130A
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,50 ± 0,1
Bo
: 7,50 ± 0,1
Ct
: 13,5 ± 0,1
t
Po
PIN Marker
P2
W
G
Ct
Bo
F
G
E
Do
Ko
Date Code
Typ
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 130a.doc
Version 1.6
VI TELEFILTER
09.11.2005
Filter specification
TFS 130A
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
pre-heating periods main-heating periods
150 °C - 170 °C
over 200 °C
60 sec. - 90 sec.
20 sec. - 25 sec.
Name:
Temperature:
Time:
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 130a.doc
VI TELEFILTER
Version 1.6
Filter specification
09.11.2005
TFS 130A
5/5
History
Version
Reason of Changes
Name
Date
1.0
Generation of preliminary specification according to customer requirements.
Dunzow W.
03.05.1999
1.1
Generation of filter specification.
Add typical values.
Dunzow W.
18.06.1999
1.2
Correct termination impedances.
Change drawing of matching networks.
Change tolerance values of mean value of group delay.
Change marking of package.
Dunzow W.
17.05.2002
1.3
Change marking of package.
Springfeldt M.
30.03.2004
1.4
- labelling changed
- filter characteristic added
- change remark
- remove centre frequency
- Change tolerance values of mean value of group delay back to version 1.1
Pfeiffer
17.08.2004
1.5
- labelling corrected
Steiner
03.09.2004
1.6
- pinning corrected
Pfeiffer
09.11.2005
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.