TFS1280 - Vectron International

Filename: TFS1280.doc
Version 2.0
Vectron International
28.10.2013
Filter specification
TFS 1280
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
231 Ω || -0.9 pF
231 Ω || -0.9 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 1280 is the minimum of the passband attenuation amin. The minimum of the passband
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter
attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 1280 MHz without any tolerance. The given values for both the relative
attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
ae
4
Nominal frequency
fN
-
Centre frequency
fC
1280
Insertion loss
Passband
Passband ripple
p-p
Relative attenuation
arel
fN
fN
fN
fN
±
±
+
-
1.5
5
20
20
MHz
MHz
MHz
MHz
...
...
...
...
fN
fN
fN
fN
±
±
+
-
5
20
180
1150
MHz
MHz
MHz
MHz
Group delay ripple within PB
Input power level
Operating temperature range
OTR
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
dB
tolerance / limit
max.
6
1280
dB
MHz
MHz
fN ±
37.5
kHz
dB
max.
1.5
dB
10
30
36
38
dB
dB
dB
dB
min.
min.
min.
min.
3.5
12
30
30
dB
dB
dB
dB
22
ns
max.
100
-
max.
5
-
- 20 °C ... + 70 °C
-
- 45 °C ... + 90 °C
0.5
ns
dBm
40 °C
TCf **
-0.05
ppm/K2
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = Tcf (ppm/K2) x (T - To)2 x fTo (MHz)
Generated:
Checked / Approved:
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS1280.doc
Version 2.0
Vectron International
28.10.2013
Filter specification
TFS 1280
2/5
Filter characteristic
insertion loss: -3.75 dB
0
-10
-10
-20
-20
-30
-30
magnitude in dB
magnitude in dB
insertion loss: -4.39 dB
0
-40
-50
-60
-40
-50
-60
-70
-70
-80
-80
-90
-90
-100
130
263
396
529
662
795
928
frequency in MHz
1061
1194
1327
1460
-100
1274
1276
1278
1280
frequency in MHz
1282
1284
1286
Construction and pin connection
(All dimensions in mm)
7
C80
● D44
1
SQ 3,81 +0,2/-0,1
5
3
1
2
3
4
5
6
7
8
Ground
Input
Ground
Ground
Ground
Output
Ground
Ground
Date code:
D
E
F
...
Year + week
2013
2014
2015
5
0,1
7
0,6
12
0%
%
d
3
1,78
2,54
1
1,2 Max.
Date code
1,78
50 Ω Test circuit
2
L1
6
L2
SAW
C1
C2
1, 3, 4, 5, 7, 8
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS1280.doc
Version 2.0
Vectron International
28.10.2013
Filter specification
TFS 1280
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per
plane, 3 planes; DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
5. ESD
-55 °C to 125°C / 15 min. each / 100 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions, see page 4: "Air reflow temperature conditions"
ANSI/ESD S20.20-1999, class 1A for HBM
This filter is RoHS compliant (2011/65/EU)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 5,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 4,30 ± 0,1
Bo
: 4,30 ± 0,1
Ct
: 9,2 ± 0,1
P1
t
PIN Marker
Po
P2
W
G
Ct
Bo
F
G
E
Do
Ko
Date Code
Typ
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS1280.doc
Version 2.0
Vectron International
28.10.2013
Filter specification
TFS 1280
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max.
260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS1280.doc
Vectron International
Version 2.0
Filter specification
28.10.2013
TFS 1280
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
S. Channaa
29.05.2009
1.1
- Change input power level, passband ripple, attenuation and OTR
S. Channaa
03.06.2009
1.2
- Change input power level, add typical values and filter characteristic
- Generation of filter specification
S. Channaa
21.12.2010
2.0
- Orientation of tape and reel corrected
- Typos corrected
A. Molke
28.10.2013
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.