Filename: TFS1280.doc Version 2.0 Vectron International 28.10.2013 Filter specification TFS 1280 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 231 Ω || -0.9 pF 231 Ω || -0.9 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 1280 is the minimum of the passband attenuation amin. The minimum of the passband attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 1280 MHz without any tolerance. The given values for both the relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value ae 4 Nominal frequency fN - Centre frequency fC 1280 Insertion loss Passband Passband ripple p-p Relative attenuation arel fN fN fN fN ± ± + - 1.5 5 20 20 MHz MHz MHz MHz ... ... ... ... fN fN fN fN ± ± + - 5 20 180 1150 MHz MHz MHz MHz Group delay ripple within PB Input power level Operating temperature range OTR Storage temperature range Frequency inversion temperature Temperature coefficient of frequency dB tolerance / limit max. 6 1280 dB MHz MHz fN ± 37.5 kHz dB max. 1.5 dB 10 30 36 38 dB dB dB dB min. min. min. min. 3.5 12 30 30 dB dB dB dB 22 ns max. 100 - max. 5 - - 20 °C ... + 70 °C - - 45 °C ... + 90 °C 0.5 ns dBm 40 °C TCf ** -0.05 ppm/K2 *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆fc(Hz) = Tcf (ppm/K2) x (T - To)2 x fTo (MHz) Generated: Checked / Approved: Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS1280.doc Version 2.0 Vectron International 28.10.2013 Filter specification TFS 1280 2/5 Filter characteristic insertion loss: -3.75 dB 0 -10 -10 -20 -20 -30 -30 magnitude in dB magnitude in dB insertion loss: -4.39 dB 0 -40 -50 -60 -40 -50 -60 -70 -70 -80 -80 -90 -90 -100 130 263 396 529 662 795 928 frequency in MHz 1061 1194 1327 1460 -100 1274 1276 1278 1280 frequency in MHz 1282 1284 1286 Construction and pin connection (All dimensions in mm) 7 C80 ● D44 1 SQ 3,81 +0,2/-0,1 5 3 1 2 3 4 5 6 7 8 Ground Input Ground Ground Ground Output Ground Ground Date code: D E F ... Year + week 2013 2014 2015 5 0,1 7 0,6 12 0% % d 3 1,78 2,54 1 1,2 Max. Date code 1,78 50 Ω Test circuit 2 L1 6 L2 SAW C1 C2 1, 3, 4, 5, 7, 8 Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS1280.doc Version 2.0 Vectron International 28.10.2013 Filter specification TFS 1280 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plane, 3 planes; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): 5. ESD -55 °C to 125°C / 15 min. each / 100 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions, see page 4: "Air reflow temperature conditions" ANSI/ESD S20.20-1999, class 1A for HBM This filter is RoHS compliant (2011/65/EU) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 12,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 5,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 4,30 ± 0,1 Bo : 4,30 ± 0,1 Ct : 9,2 ± 0,1 P1 t PIN Marker Po P2 W G Ct Bo F G E Do Ko Date Code Typ D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS1280.doc Version 2.0 Vectron International 28.10.2013 Filter specification TFS 1280 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS1280.doc Vectron International Version 2.0 Filter specification 28.10.2013 TFS 1280 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification S. Channaa 29.05.2009 1.1 - Change input power level, passband ripple, attenuation and OTR S. Channaa 03.06.2009 1.2 - Change input power level, add typical values and filter characteristic - Generation of filter specification S. Channaa 21.12.2010 2.0 - Orientation of tape and reel corrected - Typos corrected A. Molke 28.10.2013 Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.