TFS706 - Vectron International

Filename: TFS706.doc
Version 2.0
Vectron International
07.05.2014
Filter specification
TFS 706
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
0
°C
dBm
50
50
Ω
Ω
Characteristics
Remark:
The maximum attenuation within passband 1 is defined as the insertion loss ae. The nominal frequency fN is fixed at 706 MHz without any tolerance or limit.
The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
typ. value
fN
706
MHz
PB1
fN ± 12.0
MHz
Nominal frequency
Passband 1
tolerance / limit
ae
Insertion loss within PB1
2.1
dB
PB2
Passband 2
max.
3.0
fN ± 15.0
dB
MHz
Insertion loss within PB2
2.4
dB
max.
4.0
dB
Passband variation within PB2
0.6
dB
max.
2.0
dB
aabs
Absolute attenuation
fN
±
80
MHz … fN
±
149
MHz
45
dB
min.
33.5
dB
fN
+
149
MHz … fN
+
300
MHz
48
dB
min.
45.0
dB
200
MHz
58
dB
min.
50.0
dB
149
MHz
65
dB
min.
55.0
dB
10
ns
max.
0.2
µs
1
200
MHz …
MHz … fN
-
Group delay ripple within PB1
p-p
IIP3
*
Input power level
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf **
-
min.
36
dBm
-
max.
10
dBm
-
- 10 °C ... + 75 °C
-
- 40 °C ... + 85 °C
-76
ppm/K
*) fin1 = fC - 14 MHz; fin2 = fC – 14.4 MHz; Pin = 0 dBm; fmeasurement1 = fC - 13.6 MHz; fmeasurement2 = fC - 14.8 MHz. The centre frequency fc
is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae.
**)
∆f(Hz) =TCf (ppm/K) x (T-T0) x fTo (MHz)
Generated:
Checked / Approved:
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS706.doc
Version 2.0
Vectron International
07.05.2014
Filter specification
TFS 706
2/5
0
-1
0.45
-20
-2
0.4
-30
-3
0.35
-4
0.3
-5
0.25
-6
0.2
-70
-7
0.15
-80
-8
0.1
-90
-9
0.05
-40
-50
-60
-100
100
200
300
400
500
600
700
frequency in MHz
800
900
1000
1100
-10
676
1200
0.5
682
688
694
700
706
712
frequency in MHz
718
724
730
delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
0
736
Construction and pin connection
(All dimensions in mm)
7
706
● E19
1
SQ 3,81 +0,2/-0,1
5
3
7
5
0,1
12
0%
0,6
%
d
3
1,78
2,54
1
Ground
Input
Ground
Ground
Ground
Output
Ground
Ground
Date code:
E
F
G
...
Year + week
2014
2015
2016
1,2 Max.
Date code
1
2
3
4
5
6
7
8
1,78
50 Ω Test circuit
L1
2
6
L2
SAW
1, 3, 4, 5, 7, 8
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS706.doc
Version 2.0
Vectron International
07.05.2014
Filter specification
TFS 706
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0.35 mm or g respectively, 1 octave per min, 10 cycles per
plane, 3 planes; DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 15 min. each / 100 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions, see page 4: "Air reflow temperature conditions"
This filter is RoHS compliant (2011/65/EU)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 5,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 4,30 ± 0,1
Bo
: 4,30 ± 0,1
Ct
: 9,2 ± 0,1
P1
t
PIN Marker
Po
P2
W
G
Ct
Bo
F
G
E
Do
Ko
Date Code
Typ
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS706.doc
Version 2.0
Vectron International
07.05.2014
Filter specification
TFS 706
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS706.doc
Vectron International
Version 2.0
Filter specification
07.05.2014
TFS 706
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Springfeldt
14.04.2004
1.1
- Change of absolute attenuation fN + 149 … 300 MHz
- Change insertion loss
Strehl
20.01.2005
1.2
- Add typical values and filter characteristic
- Generation of filter specification
Strehl
22.06.2005
1.3
- Add IIP3 and change stability characteristics
Strehl
19.07.2006
2.0
- Additional passband with larger bandwidth specified
- Orientation of tape and reel updated
- Typos corrected
Molke
07.05.2014
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.