TFS600 - Vectron International

Filename: tfs 600.doc
Version 1.2
Vectron International
26.01.2010
Filter specification
TFS 600
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
270 Ω || -0,8 pF
285 Ω || -0,8 pF
Characteristics
Remark:
The nominal frequency fN is fixed at 600 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative attenuation
arel of the TFS 600 is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter
attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range.
Data
typ. value
Insertion loss
(reference level)
ae
3,9
Nominal frequency
fN
-
Centre frequency
fc
600,0
Passband
PB
Pass band ripple
p-p
Relative attenuation
fN
... fN
0,8
MHz ... fN
fN ±
5
MHz ... fN
fN ±
Return loss within PB
±
±
±
16
5
20
arel
kHz
MHz
MHz
OTR
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
dB
max.
TCf **
6,5
600,0
MHz
fN
±
kHz
dB
dB
max.
1
0,2
40
52
1.6:1
dB
dB
dB
max.
min.
min.
min.
1
20
30
2:1
max.
3
-
- 5 °C ... + 70 °C
-
- 30 °C ... + 80 °C
°C
-0,036
ppm/K
MHz
16
0,0
22
dB
-
-
Input power level
Operating temperature range
tolerance / limit
2
dB
dB
dB
dBm
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz).
Generated:
Checked / Approved:
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.
Filename: tfs 600.doc
Version 1.2
Vectron International
26.01.2010
Filter specification
TFS 600
2/5
Filter characteristic
3.75
-1
3.6
-12
-2
3.45
-18
-3
3.3
-24
-4
3.15
-5
3
-6
2.85
-42
-7
2.7
-48
-8
2.55
-54
-9
2.4
-30
-36
-60
580
584
588
592
596
600
604
frequency in MHz
608
612
616
620
-10
599.7
599.76
599.82
599.88
599.94
600
600.06
frequency in MHz
600.12
600.18
600.24
delay in µs
0
-6
magnitude in dB
magnitude in dB
insertion loss: -3.93 dB
0
2.25
600.3
Construction and pin connection
(All dimensions in mm)
S 600
●
A05
3
Date code
2 Max.
1
1
5,2 Max.
2,54 ±0,2
7,2 Max.
2,54 ±0,2
1
1
2
3
4
5
6
7
8
9
10
11
12
Output
Ground
Ground
Ground
Ground
Ground
Input
Ground
Ground
Ground
Ground
Ground
Date code:
A
B
C
...
Year + week
2010
2011
2012
0,80
50 Ohm Test circuit
7
L1
1
L2
SAW
C1
C2
2, 3, 4, 5, 6, 8, 9, 10, 11, 12
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.
Filename: tfs 600.doc
Version 1.2
Vectron International
26.01.2010
Filter specification
TFS 600
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,50 ± 0,1
Bo
: 7,50 ± 0,1
Ct
: 13,5 ± 0,1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.
Filename: tfs 600.doc
Version 1.2
Vectron International
26.01.2010
Filter specification
TFS 600
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.
Filename: tfs 600.doc
Vectron International
Version 1.2
Filter specification
26.01.2010
TFS 600
5/5
History
Version
Reason of Changes
Name
Date
1.0
Generated according to customer requirement
Dr. Wall
20.12.2000
1.1
Add off terminating impedances
Pfeiffer
01.03.2001
1.2
- filter characteristics added
- specification updated
Pfeiffer
26.01.2010
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.