TFS309A

Filename: tfs 309a.doc
Version 1.2
VI TELEFILTER
08.11.2007
Filter specification
TFS 309A
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
731,5 Ω || -4,5 pF
809,5 Ω || -3,8 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 309A is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 309,4 MHz without any tolerance. The given values for both the
relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
Insertion loss
(reference level)
ae
Nominal frequency
fN
-
Centre frequency
fC
309,4
PB
Passband
Pass band ripple
fN
±
±
±
±
0,75
1,5
3,0
21,4
50,0
MHz
MHz
MHz
MHz
MHz
dB
max.
7,6
309,4
MHz
dB
MHz
-
-
fN
0
dB
max.
0,40
±
0,25
MHz
0,5
dB
arel
Relative attenuation
fN
fN
fN
fN
fN
5,3
tolerance / limit
… fN
±
0,25
MHz
… fN
… fN
… fN
±
±
±
1,5
3,0
4,5
MHz
MHz
MHz
… fN
±
300,0
MHz
Group delay ripple within PB
IIP3
**
OTR
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
max.
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
10
40
50
60
50
dB
dB
dB
dB
dB
166
ns
max.
500
ns
dBm
min.
30
dBm
max.
15
dBm
33
-
Input power level
Operating temperature range
dB
13
46
53
64
57
TCf ***
0,5
-
- 40 °C ... + 85°C
-
- 55 °C ... +105°C
23
°C
-0,043
ppm/K
dB
2
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) fin1= 309,35 MHz; fin2= 309,3 MHz; Pin= -10 dBm fmeasurement = 309,4 MHz and fin1= 309,45 MHz; fin2= 304,5 MHz; Pin= - 10 dBm fmeasurement = 309,4 MHz.
***) ∆f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 309a.doc
Version 1.2
VI TELEFILTER
08.11.2007
Filter specification
TFS 309A
2/5
0
4.18
-1
3.82
-20
-2
3.46
-30
-3
3.1
-4
2.74
-5
2.38
-6
2.02
-70
-7
1.66
-80
-8
1.3
-90
-9
0.94
-40
-50
-60
-100
269.4
277.4
285.4
293.4
301.4
309.4
317.4
frequency in MHz
325.4
333.4
341.4
349.4
-10
308.65 308.8 308.95 309.1 309.25 309.4 309.55 309.7 309.85
frequency in MHz
310
delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
0.58
310.15
Construction and pin connection
(All dimensions in mm)
S 309A
●
U51
3
Date code
2 Max.
1
Input
Input RF Return
Ground
Ground
Ground
Ground
Output
Output RF Return
Ground
Ground
Ground
Ground
Date code:
U
V
W
...
Year + week
2006
2007
2008
1
5,2 Max.
2,54 ±0,2
7,2 Max.
2,54 ±0,2
1
1
2
3
4
5
6
7
8
9
10
11
12
0,80
50 Ω Test circuit
L1
1
2
7
SAW
L2
8
C2
C1
3, 4, 5, 6, 9, 10, 11, 12
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 309a.doc
Version 1.2
VI TELEFILTER
08.11.2007
Filter specification
TFS 309A
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,50 ± 0,1
Bo
: 7,50 ± 0,1
Ct
: 13,5 ± 0,1
P1
Date Code
Do
P2
W
G
Ct
Bo
F
G
E
t
Po
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 309a.doc
Version 1.2
VI TELEFILTER
08.11.2007
Filter specification
TFS 309A
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 309a.doc
VI TELEFILTER
Version 1.2
Filter specification
08.11.2007
TFS 309A
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
20.02.2006
1.1
- Change input power level and storage temperature range
Strehl
23.03.2006
1.2
- Change from development specification to filter specification
- Change Intermodulation value
- Add terminating impedance value
- Add typical values
- Add filter characteristics
- Add matching circuit
Alawneh
08.11.2007
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.