Filename: tfs 90c.doc Version 1.3 VI TELEFILTER 21.02.2007 Filter specification TFS 90C 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 202 Ω || -17 pF 202 Ω || -17 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 90C is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 90,0 MHz without any tolerance. The given values for both the relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss (reference level) ae Nominal frequency fN Centre frequency Passband 13,3 dB fC 90,0 MHz PB 34,5 MHz fN 0,15 0,2 0,3 dB dB dB max. max. max. 0,3 Passband ripple 1,5 MHz fN ± 12,0 MHz fN ± 16,0 MHz fN ± fN ± ± + + 89,7 60,0 44,0 60,0 90,0 MHz MHz MHz MHz MHz max. 17,0 dB 90,0 MHz ± 16,0 0,3 0,5 0,6 MHz dB dB dB arel Relative attenuation fN fN fN fN fN tolerance / limit … fN ± … … … … … ± ± + + fN fN fN fN fN 16,00 60,0 44,0 40,0 90,0 180,0 MHz MHz MHz MHz MHz MHz at fN Group delay dB max. 50 48 46 57 46 dB dB dB dB dB min. min. min. min. min. 45 45 30 45 35 0,6** dB dB dB dB dB dB 440 ns max. 500 ns 20 25 ns ns max. max. 40 50 ns ns - min. 30 dBm - max. 0 dBm - - 40 °C ... + 85 °C Group delay ripple fN fN ± ± 12,0 16,0 MHz MHz IIP3 *** Input power level Operating temperature range OTR - Storage temperature range Temperature coefficient of frequency TCf **** -88 - 40 °C ... + 85 °C ppm/K *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) max. 0,8 dB over temperature ***) fin1= 88 MHz; fin2= 89 MHz; Pin=0 dBm fmeasurement = 90 MHz ****) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 90c.doc Version 1.3 VI TELEFILTER 21.02.2007 Filter specification TFS 90C 2/5 0 0.744 -0.3 0.708 -14 -0.6 0.672 -21 -0.9 0.636 -28 -1.2 0.6 -1.5 0.564 -1.8 0.528 -49 -2.1 0.492 -56 -2.4 0.456 -63 -2.7 0.42 -35 -42 -70 5 22 39 56 73 90 107 frequency in MHz 124 141 158 -3 70 175 74 78 82 86 90 94 frequency in MHz 98 102 106 delay in µs 0 -7 magnitude in dB magnitude in dB Filter characteristic 0.384 110 Construction and pin connection (All dimensions in mm) S 90C ● V01 Date code 1 2 3 4 5 6 7 8 9 10 Ground Ground Ground Output Output RF Return Ground Ground Ground Input Input RF Return Date code: V W X ... Year + week 2007 2008 2009 Terminations plating: Ni>2µm, Au>0,75µm 50 Ohm Test circuit L1 9 10 4 SAW L2 5 C2 C1 1, 2, 3, 6, 7, 8 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 90c.doc Version 1.3 VI TELEFILTER 21.02.2007 Filter specification TFS 90C 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 7,50 ± 0,1 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 5,50 ± 0,1 Bo : 7,50 ± 0,1 Ct : 13,5 ± 0,1 P1 Date Code Do P2 W G Ct Bo F G E t Po Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 50 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 90c.doc Version 1.3 VI TELEFILTER 21.02.2007 Filter specification TFS 90C 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 90c.doc VI TELEFILTER Version 1.3 Filter specification 21.02.2007 TFS 90C 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 14.06.2006 1.1 - Change construction Strehl 08.12.2006 1.2 - Created filter specification - Added terminating impedances - Added typical values - Added temperature coefficient of frequency - Added filter characteristic - Changed construction - Added test circuit - Changed packing Chilla 04.01.2007 1.3 - Added terminations plating Chilla 21.02.2007 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.