ZSSC3154 MAF Sensor Board

Application Note
Rev. 2.10 / March 2015
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
Multi-Market Sensing Platforms
Precise and Deliberate
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
Contents
1
2
3
Introduction ....................................................................................................................................................... 3
Hot-Film Flow Measurement Principles ........................................................................................................... 4
Mass Air Flow Measurement with the ZSSC3154............................................................................................ 5
3.1. Advantages, Applications, Technical Details, and Test Data .................................................................... 5
3.2. ZSSC3154 MAF Sensor Board Schematic ............................................................................................... 7
3.3. Constant Temperature Anemometer (CTA) Operation ............................................................................. 8
3.4. Low Flow Operation ................................................................................................................................... 8
3.5. Flow Direction Indication ........................................................................................................................... 8
4 ZSSC3154 Evaluation Kit Setup ...................................................................................................................... 9
4.1. Hardware Setup ......................................................................................................................................... 9
4.2. ZSSC3154 Evaluation Software .............................................................................................................. 10
4.3. ZSSC3154 Input Signal Adaptation and Configuration ........................................................................... 11
5 ZSSC3154 Configuration and Calibration ...................................................................................................... 13
6 PCB Layout .................................................................................................................................................... 15
7 Bill of Materials (BOM) ................................................................................................................................... 16
8 Additional Documents .................................................................................................................................... 17
9 Abbreviations .................................................................................................................................................. 17
10 Document Revision History ............................................................................................................................ 18
List of Figures
Figure 1.1
Figure 2.1
Figure 3.1
Figure 3.2
Figure 3.3
Figure 4.1
Figure 4.2
Figure 4.3
Figure 5.1
Figure 6.1
ZSSC3154 Evaluation Kit ................................................................................................................... 3
Hot-Film Flow Measurement ............................................................................................................... 4
Mass Air Flow Sensor Board .............................................................................................................. 6
FS2 Flow Sensor Layout .................................................................................................................... 6
MAF Sensor Board Schematic ........................................................................................................... 7
Setting up the ZSSC3154 Evaluation Kit ............................................................................................ 9
ZSSC3154 Evaluation Software ....................................................................................................... 10
Operational Modes ........................................................................................................................... 11
ZSSC3154 Evaluation Software ....................................................................................................... 14
MAF Sensor Board ........................................................................................................................... 15
List of Tables
Table 3.1
Table 4.1
Table 4.2
Table 4.3
Table 5.1
Signal Connections ............................................................................................................................. 7
ZSSC3154 Evaluation Board Jumper Setting Options Depending on the Flow Range ..................... 9
ZSSC3154 Input Signal Adaptation and Configuration for User Applications .................................. 11
AOUT2 Modes of Operation ............................................................................................................. 12
Configuration and Calibration ........................................................................................................... 13
For more information, contact ZMDI via [email protected].
Data Sheet
March 26, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
2 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
1
Introduction
The ZSSC3154 Sensor Signal Conditioner (SSC) can enable mass air flow sensing applications by conditioning
the air flow sensor signal. The ZSSC3154 is optimized for resistive bridge sensor measurements commonly used
in air flow sensing applications. To expedite the design of these applications, ZMDI provides the ZSSC3154 Mass
Air Flow (MAF) Sensor Board option for use with the ZSSC3154 Evaluation Kit in place of the kit’s Sensor
Replacement Board as shown in Figure 1.1. The MAF Sensor Board also includes a flow channel for the
measurement. The ZSSC3154 is installed in a socket on the kit’s ZSSC3154 Evaluation Board.
This application note covers the general principles of air flow sensing and the specific details for using the MAF
Sensor Board with the ZSSC3154 Evaluation Kit. Reading the ZSSC3154 Data Sheet and ZSSC3154 Evaluation
Kit Description first is strongly recommended.
Figure 1.1 ZSSC3154 Evaluation Kit
Data Sheet
March 26, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
3 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
2
Hot-Film Flow Measurement Principles
A mass air flow (MAF) sensor converts the amount of air into a voltage signal. Units used are usually kilogram per
second (kg/s). For example, air flow mass is a necessary parameter in engine operation in order to determine
how much fuel to inject, ignition timing, and when to shift the gears. Used in conjunction with an oxygen sensor,
the mass air flow sensor measurement can enable very accurate control of the fuel ratio.
There are different types of MAF sensors. The hot-film type sensor is more common. It consists of a heating
element (typically a temperature-dependent, low-ohm platinum resistor) and an additional temperature sensor.
Flow direction can also be determined with specific sensor configurations. The temperature sensor (Pt in Figure
2.1) is used as a reference for the heating element to maintain a constant reference to the ambient temperature,
which can be provided by an electronic control circuit such as a constant temperature anemometer (CTA) as
shown in Figure 2.1. The voltage needed to heat the element in order to maintain thermal equilibrium with the
ambient temperature is proportional to the air mass flow through the sensor. Higher flow increases the cooling of
the element, which is compensated by raising the voltage of the heating element. This measuring principal covers
large operational ranges with high accuracy and a wide temperature operating range.
Figure 2.1 Hot-Film Flow Measurement
Constant Temperature
Anemometer (CTA)
ITR
2
1
2
VCC
R1
R2
where E is the transferred thermal energy;
2
W=I RW is power generated by Joule
R4
R3
heating; and H is the heat transfer to
surroundings.
I
R5
Based on this, according to King’s Law,
1
2
2
With Flow
1: Heating element
2: Temperature sensor
𝑑𝐸
=𝑊−𝐻
𝑑𝑡
TR1
V_Bs
No Flow
Transfer of energy:
Pt
U
ϑ
E
Hot-Film
with RW
ϑ – Flow Velocity
E – Transferred Energy
𝑊 = 𝐸 2 = (𝑇𝑊 − 𝑇𝑎 )(𝐴 + 𝐵 ∗ 𝜗 𝑛 ),
where the voltage drop is a measure of
velocity:
𝑈 = 𝑈0 √1 + 𝑘 ∗ 𝜗 𝑛
The air density can vary, which changes the thermal capacity of the air. The density is function of the ambient
temperature, altitude, and pressure, which makes mass flow meters more appropriate for determining the quantity
of the air.
Another factor that should be taken in account is the air humidity. An increase in the humidity decreases the air
density. This is because the molecule mass of water is less than the molecule mass of air, and for any gas at a
given pressure and temperature, there is a constant number of molecules for a particular volume. This results in a
decrease in the gas mass per unit volume.
MAF sensors feature a quick response time, small overall package, less sensitivity to mounting and orientation,
durability, and lower costs.
Care should be taken to prevent contamination of the sensor, which reduces the accuracy. Possible
thermocoupling between the heating element and the temperature sensor should be taken in account as well.
Data Sheet
March 26, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
4 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
3
Mass Air Flow Measurement with the ZSSC3154
3.1.
Advantages, Applications, Technical Details, and Test Data
The ZSSC3154 Sensor Signal Conditioner and the ZSSC3154 Evaluation Kit with the ZSSC3154 Mass Air Flow
(MAF) Sensor Board (Figure 3.1) can be used to demonstrate measurements of the mass and direction of air flow
and to expedite design of the user’s application. See Figure 3.3 for the schematics for the MAF Sensor Board.
Settings for the jumpers on the board are provided in section 3.3.
The ZSSC3154 Evaluation Kit enables calibration and evaluation of the ZSSC3154.
This method offers simple signal processing and calibration with excellent reproducibility and long-term stability.
There are no moving mechanical components. The sensor module allows easy adaptation for different
applications and housings.
Possible air flow sensing applications for the ZSSC3154:

HVAC and building-control solutions

Medical devices

Automotive industry products

Device monitoring
The air flow sensor element used on the MAF Sensor Board is the FS2 sensor by IST AG, which consists of four
temperature-dependent platinum-resistors, all on-chip. See Figure 3.2. A low-ohm resistor with a small area is
used as a heating element (top center of Figure 3.2), and the two high-ohm resistors at the top to the right and left
of the element are for measuring the mass flow and the direction. These two sensors placed on each side of the
heating element are connected in a bridge circuit, which gives a clear signal for measuring the volume and the
direction of the flow. When there is no flow of the air medium, the heating element heats both sensors equally.
When there is air flow, one sensor is cooled more than the other depending on the direction of the flow.
Depending on the temperature difference between the two resistances, the flow volume can be determined. As a
result of its small thermal mass, this flow sensor has fast heating and cooling response times. This system allows
measuring a very small flow volume and can simultaneously detect the direction of the flow. The resistor on the
lower left in Figure 3.2 functions as the Pt ambient temperature sensor.
To measure higher mass flow volumes, an optional on-board constant temperature anemometer (CTA) can be
used.
Data Sheet
March 26, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
5 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
Figure 3.1 Mass Air Flow Sensor Board
Flow Channel
Jumper J1:
Power Enable
PT1000 Sensor
(Flow Temperature)
Heater Power Supply:
CTA / VCC
Trimming Potentiometer:
Heater Temperature Offset
CTA Enable
Heater Enable
Flow Sensor
Flow Sensor Bridge Supply:
BR_T / V_Out
Trimming Potentiometer:
Sensor Bridge Balance
External Temperature Sensor:
Diode / PT1000
Diode Sensor
(Ambient Temperature)
Signal to P/N Inputs Selection:
High: Signal from V_Out
Low: Signal From Sensor
Figure 3.2 FS2 Flow Sensor Layout
FS2 ( http://www.ist-ag.com/; http://www.ist-usadivision.com)
(Note: View is rotated 90° counter-clockwise relative to Figure 3.1)
RH(25°C) = 3410%
Rs_left (25°C) = 42510%
Rs_right (25°C) = 42510%
Pt (25°C) = 71010%
Common
R_s_right
RH
RH
R_s_left
Pt
(© Copyright IST AG. Used with permission.)
Data Sheet
March 26, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
6 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
3.2.
ZSSC3154 MAF Sensor Board Schematic
Figure 3.3 provides the schematic for the MAF Sensor Board, which is designed to be connected to the
ZSSC3154 Evaluation Kit. The functionality of the circuit blocks is described in subsequent sections.
The P1 connector transfers the signals from the MAF Sensor Board to the pins of ZSSC3154 on the Evaluation
Board via the following connector pins.
Table 3.1
Signal Connections
P1 Connector
ZSSC3154 Pin
VTN
VTN1
GND (BR_B)
VBR_B (bottom of bridge)
BR_T
VBR_T (top of bridge)
P
VBP
N
VBN
Figure 3.3 MAF Sensor Board Schematic
Data Sheet
March 26, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
7 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
3.3.
Constant Temperature Anemometer (CTA) Operation
The optional CTA can extend the operation range of the sensors on the MAF Sensor Board. The CTA is needed
for high flow rates. To select the CTA option, install jumpers on both the “CTA” connector (J2) and across pins 1
and 2 (CTA position on the left) on the “Heater Supply CTA/VCC” connector identified in Figure 3.1. In this
configuration, the hot-film of the FS2 sensor (the “Heater” signal line in Figure 3.3) is connected to the
temperature sensor (Pt710) in a bridge configuration. The bridge is balanced when the heater reaches a specific
elevated temperature above the ambient temperature (usually approximately 20°C higher), defined by the rest of
the resistors in the bridge. The bridge supply voltage (V_Out) must be selected via a jumper across pins 1 and 2
on the “Bridge Supply V_out/BR_T” connector. V_Out changes with the change of the air flow around the sensor;
this change in voltage is a measure of the mass air flow.
This configuration allows direct placement of the sensor in the flow without an individual flow channel. It also
allows measuring high flow rates. Resistor values in the CTA circuit are application-specific and would be adapted
in the final user application.
3.4.
Low Flow Operation
For low flows, the sensors can be supplied directly from the BR_T pin on the ZSSC3154 instead of using the
CTA. The BR_T supply is selected via a jumper across pins 2 and 3 on the “Bridge Supply V_out/BR_T”
connector. In this configuration, bridge resistance must be adapted to a minimum 1k ohm and the signal range
must be placed in the acceptable common mode voltage region by resistors R16, R17 and R18 (see Table 4.1 or
Figure 3.1 for jumper settings depending on flow range).
3.5.
Flow Direction Indication
Flow direction can also be detected with the FS2 sensors aligned in series to the flow. The “” and “” LEDs on
the MAF Sensor Board indicate the direction of the air flow as a result of comparison of the “P” and “N” inputs.
Balancing the “P” and “N” inputs can be done with the “Offset” trimming potentiometer for proper operation.
For this application, a laminar flow is required and a separate channel (bypass) is needed for high flow rates.
However, signals can be connected to the ZSSC3154 sensor conditioner directly where calibration and offset
compensation are performed.
Data Sheet
March 26, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
8 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
4
ZSSC3154 Evaluation Kit Setup
4.1.
Hardware Setup
Connect the ZSSC3154 Evaluation Kit boards as shown in Figure 4.1 and use the USB cable to connect the
Communication Board to a USB port on the user’s PC. Install the ZSSC3154 in the socket on the ZSSC3154
Evaluation Board (pin 1 is at the top right).
Install the jumpers on the MAF Sensor Board according to the application as indicated in Table 4.1. Refer to
Figure 3.1 for the options for jumper positions.
Figure 4.1 Setting up the ZSSC3154 Evaluation Kit
Table 4.1
ZSSC3154 Evaluation Board Jumper Setting Options Depending on the Flow Range
Low Flow
(0m/s to 3m/s)
High Flow
(0m/s to 100m/s)
CTA


VCC

Connector Position
CTA Supply (Connector labeled “Heater Supply”)
Signal P/N (Connectors labeled “Signal P High-[P]-Low” and “Signal N High-[N]-Low”)
V_Out (Signal P) or VCC/2 (Signal N)

Sensor Bridge


Bridge Supply
BR_T

V_Out

Data Sheet
March 26, 2015

© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
9 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
4.2.
ZSSC3154 Evaluation Software
Follow the instructions given in the ZSSC3154 Evaluation Kit Description to download the ZSSC3154 Evaluation
Kit Software from the ZSSC3154 web page at www.zmdi.com/zssc3154 and install it on the user’s PC. The
software provides a graphical user interface (GUI) for configuring and calibrating the ZSSC3154 as well as taking
sensor measurements and reading registers.
Figure 4.2 ZSSC3154 Evaluation Software
Data Sheet
March 26, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
10 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
4.3.
ZSSC3154 Input Signal Adaptation and Configuration
All sensor signals that are input to the ZSSC3154 (i.e., flow and temperature for this application) must be within
the ZSSC3154 specifications for common mode voltage (CMV) for signal level and bridge resistance. The
ZSSC3154 is capable of supplying a maximum of 5.5mA driving current. The components in the “Output Signals
Selection” section of the MAF Sensor Board (see Figure 3.3) allow adapting the sensor signals to meet the
ZSSC3154 requirements.
Table 4.2
ZSSC3154 Input Signal Adaptation and Configuration for User Applications
Parameter
Specifications
Common Mode Voltage (Signal_N and Signal_P)
From 29% BR_T to 65% BR_T
Bridge Resistance
From 1k to 10kΩ
Maximum BR_T Current
5.5mA
VTN Input Range
Diode: BR_T-0.2V to BR_T-1V; Resistor: BR_T-1.4V to BR_T-0.3V
Heater Voltage Range (FS2)
2 V DC to 5 V DC
Heater Power Dissipation
6.6mW at 2V heater voltage; 14.9mW at 3 V heater voltage
26.4mW at 4V heater voltage; 41.3mW at 5 V heater voltage
MAF Board Current Consumption
50mA
Supply Voltage
5V external supply (no reverse polarity protection)
When the ZSSC3154 is in a continuous measurement cycle, the conditioned
full-bridge (FB) sensor signal is output at the AOUT1 pin.
Figure 4.3 Operational Modes
At the AOUT2 pin, there are several options for the output mode, which can
be configured in the EEPROM via the GUI. A separate temperature
measurement is available for the output of a conditioned temperature signal.
A half-bridge (HB) measurement is available for validating the main bridge
sensor signal.
The half-bridge sensor signal can be used to validate the bridge sensor
signal output at the AOUT1 pin.
The necessary settings can be configured using the GUI as illustrated in
Figure 4.3. For more information, refer to the ZSSC3154 Evaluation Kit
Description.
In Table 4.3 all modes of the AOUT2 pin are listed with the corresponding configuration settings.
Recommendation: If the filter function is used for the bridge sensor signal, set the coefficients for filtering the halfbridge signal to the same value (PAVG1/2 and PDIFF1/2).
The sequential AOUT2 output enables the system to evaluate more measurement parameters with the same
number of outputs or connections to the ZSSC3154.
Note: Validating the main signal channel via the half-bridge sensor signal disables the analog front-end built-in
self-test (BIST) functionality.
Data Sheet
March 26, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
11 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
Table 4.3
AOUT2 Modes of Operation
Mode
AOUT2
Single Temperature and
Bridge Signal
Single Half Bridge
Configuration Word CFGAPP2, Bits 14:11
Selected temperature sensor
0000
1 – FB
0001
FB / 2
0010
(1 - FB)/2
0011
Half-Bridge
01xx
Selected temperature sensor and FB
1000
Selected temperature sensor and 1 - FB
1001
Selected temperature sensor and FB / 2
1010
Selected temperature sensor and (1 - FB) / 2
1011
HB and FB
1100
HB and 1 - FB
1101
HB and FB / 2
1110
HB and (1- FB) / 2
1111
Sequential Temperature
Sequential Half Bridge
Data Sheet
March 26, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
12 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
5
ZSSC3154 Configuration and Calibration
All necessary settings for the ZSSC3154 can be configured via the ZSSC3154 Evaluation KIT GUI with the MAF
Sensor Board can be connected. Table 5.1describes the set of the parameters that will enable the flow
measurement described in the previous sections:
Table 5.1
Configuration and Calibration
Selects sensor sensitivity and sets the AFE gain.
For a large sensor signal offset (sensor signal present without actual air
mass flow), the XZC function can be enabled to compensate it.
Half-bridge measurement and settings are not used in this application.
The input signal range is fitted to the ADC output by selecting a range
shift corresponding to the input signal symmetry.
½ for symmetrical signals
7
¾, /8 and
15
/16 for non-symmetrical signals
The selected “Range Shift” value of the digital output corresponds to the
analog input’s common mode voltage (CMV) (the analog ground =
½ VADC_REF).
For this application, ½ range shift should be selected (bi-directional flow).
Temperature measurement is configurable for an internal sensor and up
to two external sensors (resistive or diode types). It can be used for
temperature drift compensation during sensor measurement (Calibration
TS setting) and ambient temperature measurement (external or internal
sensor).
PAVG and PDIFF are parameters for the digital output signal.
Mode selection: single bridge and temperature measurement.
The recommended setting for the main bridge sensor measurement
(BrSens/Main) is second-order calibration (3 flow speeds, where the
middle one is at 0m/s corresponding to 50% output signal) and linear for
the temperature measurement (2 points at maximum and minimum
temperatures).
Data Sheet
March 26, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
13 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
Figure 5.1 ZSSC3154 Evaluation Software
Data Sheet
March 26, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
14 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
6
PCB Layout
Figure 6.1 MAF Sensor Board
Data Sheet
March 26, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
15 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
7
Bill of Materials (BOM)
Designator
Description
Part Number
Quantity
R5
1M 0.125W 1% 0805 (2012 Metric) SMD
1
R1, R3, R9, R10, R11, R15
2K2 0.125W 1% 0805 (2012 Metric) SMD
6
R2
6K8 0.125W 1% 0805 (2012 Metric) SMD
1
R12, R13, R14
10K 0.125W 1% 0805 (2012 Metric) SMD
3
R6
38R 0.125W 1% 0805 (2012 Metric) SMD
1
R8
430R 0.125W 5% 0805 (2012 Metric) SMD
1
R4
620R 0.125W 1% 0805 (2012 Metric) SMD
1
C1, C2, C3, C4
CAP 1nF 25V ±1% 0805 (2012 Metric)
Thickness 1mm SMD
4
D1
Diode, 2-Pin SMA Package, RoHS
Bridge Supply
Header, 3-Pin
1
Heater Supply
Header, 3-Pin
1
Signal N
Header, 3-Pin
1
Signal P
Header, 3-Pin
1
Temp. Sense
Header, 3-Pin
1
PT1000
IST P1K0.0805.2P.B
J1
Jumper 2p Closed
1
J2
Jumper 2p Closed
1
J3
Jumper 2p Closed
1
R7, R16, R17, R18
Jumper 0805 (2012 Metric)
4
MH1, MH2
Mounting Hole
2
Q1
NPN Silicon, SOT-23, Pb-Free
MMBTA05LT3G
1
U1
Operational Amplifier RR, 5-pin SOT23, RoHS
TLV27L1IDBVR
1
U2
Operational Amplifier, TSSOP, Pb-Free
LM2902VDTBR2G
1
P1
RECEPTACLE, 2.54MM, R/A DUAL, 50WAY
1
Temp.Offset
Square Trimming Potentiometer 200R
1
Balance
Square Trimming Potentiometer 500R
1
5V
Test Point Single, Black
1
BR_B, BR_T, CTA+, CTA-, N, P,
V_Out
Test Point Single, Black
7
GND1, GND2
Test Point
2
FS2
Thermal Mass Flow Sensor FS2T.0.1E.025
-->, <--, Enable, Power
Typical INFRARED GaAs LED
Data Sheet
March 26, 2015
S1M-13-F
IST P1K0.0805.2P.B
FS2T.0.1E.025
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
1
1
1
4
16 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
8
Additional Documents
Document
File Name (where x_yy refers to the current firmware version)
ZSSC3154 Data Sheet
ZSSC3154_Data_Sheet_rev_X_xy.pdf
ZSSC3154 Functional Description
ZSSC3154_Functional_Description_rev_X_xy.pdf
SSC Command Syntax *
SSC_CommandSyntax_Rev_x_yy.xls
ZSSC3154 Evaluation Kit Description
ZSSC3154_Evaluation_Kit_Description_Rev_X_xy.pdf
ZSSC3154 Technical Note – Power Management
ZSSC3154_Tech_Note_PowerManagement_Rev_X_xy.pdf
Visit the ZSSC3154 product page www.zmdi.com/zssc3154 on ZMDI’s website www.zmdi.com or contact your
nearest sales office for the latest version of these documents.
* Note: Documents marked with an asterisk are available on the SSC Tools page: http://www.zmdi.com/ssc-tools.
9
Abbreviations
Term
Description
ADC
Analog-to-Digital Converter
AFE
Analog Front End
SSC
Sensor Signal Conditioner
BIST
Built-in Self-Test
XZC
Extended Zero Compensation (analog offset compensation)
GUI
Graphical User Interface
Data Sheet
March 26, 2015
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
17 of 18
ZSSC3154 MAF Sensor Board
Mass Air Flow Measurement
10 Document Revision History
Revision
Date
Description
1.00
March 9, 2012
First release
2.00
June 2, 2014
Schematic and PCB updated.
2.10
March 17, 2015
Schematic and PCB updated.
Software illustrations updated.
Update for contact information.
Minor edits for clarity.
2.11
March 26, 2015
Update for FS2 resistance specifications in Figure 3.2 and change from Pt600 to
Pt710 in Figure 3.3 and section 3.3.
Sales and Further Information
www.zmdi.com
[email protected]
Zentrum Mikroelektronik
Dresden AG
Global Headquarters
Grenzstrasse 28
01109 Dresden, Germany
ZMD America, Inc.
1525 McCarthy Blvd., #212
Milpitas, CA 95035-7453
USA
Central Office:
Phone +49.351.8822.306
Fax
+49.351.8822.337
USA Phone 1.855.275.9634
Phone +1.408.883.6310
Fax
+1.408.883.6358
European Technical Support
Phone +49.351.8822.7.772
Fax
+49.351.8822.87.772
DISCLAIMER: This information applies to a product under development. Its characteristics and specifications are subject to change without notice.
Zentrum Mikroelektronik Dresden AG (ZMD AG) assumes no obligation regarding future manufacture unless otherwise agreed to in writing. The
information furnished hereby is believed to be true and accurate. However, under no circumstances shall ZMD AG be liable to any customer,
licensee, or any other third party for any special, indirect, incidental, or consequential damages of any kind or nature whatsoever arising out of or
in any way related to the furnishing, performance, or use of this technical data. ZMD AG hereby expressly disclaims any liability of ZMD AG to any
customer, licensee or any other third party, and any such customer, licensee and any other third party hereby waives any liability of ZMD AG for
any damages in connection with or arising out of the furnishing, performance or use of this technical data, whether based on contract, warranty,
tort (including negligence), strict liability, or otherwise.
European Sales (Stuttgart)
Phone +49.711.674517.55
Fax
+49.711.674517.87955
Data Sheet
March 26, 2015
Zentrum Mikroelektronik
Dresden AG, Japan Office
2nd Floor, Shinbashi Tokyu Bldg.
4-21-3, Shinbashi, Minato-ku
Tokyo, 105-0004
Japan
ZMD FAR EAST, Ltd.
3F, No. 51, Sec. 2,
Keelung Road
11052 Taipei
Taiwan
Phone +81.3.6895.7410
Fax
+81.3.6895.7301
Phone +886.2.2377.8189
Fax
+886.2.2377.8199
Zentrum Mikroelektronik
Dresden AG, Korea Office
U-space 1 Building
Unit B, 906-1
660, Daewangpangyo-ro
Bundang-gu, Seongnam-si
Gyeonggi-do, 463-400
Korea
Phone +82.31.950.7679
Fax
+82.504.841.3026
© 2015 Zentrum Mikroelektronik Dresden AG — Rev. 2.10
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
18 of 18