TF0111 Tunable Avionics Pre-selector Filter Datasheet

TF0111 Varactor Tunable Preselector Filter
118MHz – 137MHz – typical performance
I. General & Electrical Requirements
1.
2.
3.
4.
5.
6.
7.
8.
9.
Tuned Center Frequency Range:
FMIN = 118MHz to FMAX = 137MHz
Passband @ 3dB: FSIG ±600kHz
Passband Insertion Loss: ≤ 3.5dB
Input/Output VSWR (within the FSIG Bandwidth into 50): < 1.50:1
Absolute Stop Band Attenuation:
FSIG ±10%: 15dB minimum
FSIG ±20%: 25dB minimum
In-Band IIP3: +30dBm minimum
In Band RF Power Handling: ≤ +20dBm (Peak, No Damage)
ZIN/ZOUT: 50 nominal
Tuning Method:
Voltage Control (VTUNE): +1.0VDC to +10.0VDC
II. Environmental & Physical Requirements
1.
Temperature Range:
Operating: -40°C to +85°C
Storage: -45°C to +90°C
2.
Solderability: Per EIAJ-STD-002
3.
Package:
Size: 1.25” (L) x 0.5” (W) x 0.350” (Max., H)
Type: SMD (See Figure 1)
Reflow Profile: See Figure 2
Tape & Reel: 100-unit minimum
Figure 2: Reflow Profile
Figure 1: TF0111 Outline & PAD Layout Drawing
III. Data Sheet Revision:
Date
Rev.
Author
9/11/13
B
MFE
07/09/13
06/28/13
A
-
BRM
BRM
Details of Revision
Adjusted the Stop Band, VSWR, and voltage range specification points and added a Max. notation for package
height..
Updated the Figure 1 drawing to include a suggested PAD Layout.
Original Draft.
Page 1 of 1
MtronPTI - 2525 Shader Road - Orlando - Florida - 32804 - USA - 1-407-298-2000 - www.mtronpti.com
MtronPTI may change specifications without notice to improve end application performance or product manufacturability.
No liability is assumed as a result of product use or application.
Please contact MtronPTI for latest information.