CHPFR www.vishay.com Vishay Sfernice ESCC ( ) 4001/026 Qualified R Failure Rate High Precision Thick Film Chip Resistors FEATURES • Load life stability at ± 70 °C for 2000 h: 2.5 % under Pn • Temperature coefficient to: 100 ppm/°C • HCHP option R0094: for high frequency applications (up to 10 Ghz) • Tolerances down to 1 % • R failure rate (level E7) • SMD wraparound chip resistor • Generic specification ESCC 4001 • Detailed specification ESCC 4001/026 • Robust terminations Vishay Sfernice thick film chip resistors CHPFR are specially designed to meet the requirements of the ESCC 4001/026 specification. They have undergone the CNES evaluation (Space French National Agency). They are in level 1 of the ESCC EPPL (European Preferred Part List) and ESCC qualified. At the end of production a 100 % overload screening is performed. • Large ohmic value range 1 to 10 M • ESCC ( ) qualified • Material categorization: for definitions of compliance please see www.vishay.com/doc?99912 Sputtered Thin Film terminations, with nickel barrier, are very convenient for high operating conditions. They can withstand thousands of very severe thermal shocks. • SnPb (W/A) terminations over nickel barrier for solder reflow (variant 11 to 15) • Gold (W/A) terminations gold over nickel barrier for gluing (variant 16 to 20) DIMENSIONS in millimeters A D D B C E E DIMENSIONS in millimeters VARIANT NUMBER STYLE A B C D E MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. 11, 16 0603 1.36 1.68 0.72 0.98 0.38 0.53 0.17 0.51 0.25 0.51 12, 17 0805 (1) 1.75 2.07 1.14 1.4 0.38 0.53 0.17 0.51 0.25 0.51 13, 18 1206 2.89 3.21 1.47 1.73 0.38 0.53 0.17 0.51 0.25 0.51 14, 19 2010 4.92 5.24 2.41 2.67 0.5 0.63 0.25 0.64 0.25 0.64 15, 20 2512 6.19 6.51 2.93 3.32 0.5 0.63 0.25 0.64 0.25 0.64 Note (1) Model CHPFR0805 being same size than case 0705 with same performances, only codification of CHPFR0805 remains. Revision: 13-May-16 Document Number: 52033 1 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 CHPFR www.vishay.com Vishay Sfernice CLIMATIC SPECIFICATIONS MECHANICAL SPECIFICATIONS Operating temperature range Substrate Soldering temperature (Tsol) -55 °C; +155 °C Thick film (ruthenium oxyde) Alumina Technology Thick film (ruthenium oxyde) Protection Epoxy coating TYPICAL HF PERFORMANCE OF HCHP 2.0 1Ω 1.8 1.6 B (W/A): SnPb over nickel barrier for solder reflow G (W/A) type: Gold over nickel barrier for gluing Terminations 10 Ω 1.4 PACKAGING |Z|/R 1.2 100 Ω 1.0 Waffle-pack or tape and reel when specified 200 Ω 0.8 NUMBER OF PIECES PER PACKAGE 0.6 SIZE 1 kΩ 0.4 1 MΩ 0.2 100 kΩ 10 kΩ 0603 0 1 10 100 1000 10 000 Size 0603 (W/A) f (MHz) TAPE AND REEL (1) MIN. 1206 140 2010 60 2512 45 TAPE WIDTH MAX. 5000 100 0805 POWER DERATING CURVE Rated Power (%) WAFFLE PACK 2" x 2" 100 4000 2000 8 mm 8 mm Note (1) MOQ for tape and reel: 50 pieces 100 80 60 40 20 0 0 20 40 60 70 80 100 120 140 155 Ambient Temperature in °C SUGGEESTED LAND PATTERN (please refer to IPC-7351A) Gmin. Xmax. Zmax. CHIP SIZE Zmax. Gmin. Xmax. 0603 2.38 0.34 0.98 0805 2.77 0.73 1.40 1206 3.91 1.87 1.73 2010 5.94 3.64 2.67 2512 7.21 4.91 3.32 Revision: 13-May-16 Document Number: 52033 2 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 CHPFR www.vishay.com Vishay Sfernice STANDARD ELECTRICAL SPECIFICATIONS MODEL SIZE CHPFR CHPFR CHPFR CHPFR CHPFR CHPFR CHPFR CHPFR CHPFR CHPFR 0603 0805 1206 2010 2512 0603 0805 1206 2010 2512 RESISTANCE RANGE Rn 1 to 10M 1 to 10M 1 to 10M 1 to 10M 1 to 10M 1 to 10M 1 to 10M 1 to 10M 1 to 10M 1 to 10M POWER RATING (1) W TOLERANCE (2) ±% TEMPERATURE COEFFICIENT (2) (± 10-6/°C) CRITICAL RESISTANCE k TERMINAL MATERIAL AND FINISH 0.1 0.2 0.25 0.5 0.8 0.1 0.2 0.25 0.5 0.8 1, 2, 5 1, 2, 5 1, 2, 5 1, 2, 5 1, 2, 5 1, 2, 5 1, 2, 5 1, 2, 5 1, 2, 5 1, 2, 5 100, 200 100, 200 100, 200 100, 200 100, 200 100, 200 100, 200 100, 200 100, 200 100, 200 25 50 160 180 112.5 25 50 160 180 112.5 E4 E4 E4 E4 E4 E2 E2 E2 E2 E2 Notes (1) At T amb > +70 °C derate linearly to 0 W at Tamb = +155 °C. (2) Restrictions might apply depending on ohmic value please refer to Table 1 TABLE 1 RESISTANCE () VALUE SERIES AVAILABLE TOLERANCE (± %) 1 Rn < 10 10 Rn < 1M 1M Rn < 10M Any value in the resistance range to 3 significant figures 2, 5 1, 2, 5 2, 5 AVAILABLE TEMPERATURE COEFFICIENT (± 10-6/°C) 200 100, 200 200 MAXIMUM RATINGS CHARACTERISTICS Limiting element voltage Rated voltage Isolation voltage VARIANT NUMBER STYLE 11, 16 0603 50 12, 17 0805 100 13, 18 1206 14, 19 2010 15, 20 2512 All All 11, 16 0603 12, 17 0805 13, 18 1206 14, 19 2010 SYMBOLS UL LIMITS 200 UNITS REMARKS V - V (3) V - Tamb 300 300 UR Pn x Rn 100 200 UI 300 300 15, 20 2512 Operating temperature range All All Top -65 to +155 °C Storage temperature range All All Tstg -65 to +155 °C - Soldering temperature All All Tsol +260 °C (4) g - Maximum weight 300 11, 16 0603 0.002 12, 17 0805 0.004 13, 18 1206 0.008 14, 19 2010 0.026 15, 20 2512 0.042 Notes (3) Shall never exceed limiting element voltage. R = Rated resistance. n (4) Duration 10 s maximum. Revision: 13-May-16 Document Number: 52033 3 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 CHPFR www.vishay.com Vishay Sfernice PERFORMANCE CONDITIONS LIMITS REQUIRED BY THE ESCC4001/026 SPECIFICATION ESCC4001 § 8.3.1.2 V = 100 V 1000 M Low temperature electrical measurement ESCC4001 § 8.3.1.1 TC = 100 ppm/°C TC = 200 ppm/°C ± 0.8 % ± 1.6 % High temperature electrical measurement ESCC4001 § 8.3.3 TC = 100 ppm/°C TC = 200 ppm/°C ± 1.36 % ± 2.72 % TEST Insulation resistance ESCC4001 § 8.8 ± 0.25 + (0.05 x 100/Rn) % ESCC4001 § 8.11.2 ± 0.25 + (0.05 x 100/Rn) % Resistance to solder heat ESCC4001 § 8.12 ± 0.5 + (0.05 x 100/Rn) % Climatic sequence ESCC4001 § 8.10 ± 1 + (0.05 x 100/Rn) % Load life ESCC4001 § 8.13 1000 h 2000 h ± 1.5 + (0.05 x 100/Rn) % ± 2.5 + (0.05 x 100/Rn) % Rapid change of temperature Robustness of terminations GLOBAL PART NUMBER INFORMATION LIMITED TO 18 DIGITS: If more digits are necessary a cofication of some digits might be necessary C H P F R 0 6 0 3 K 1 0 0 1 F B T GLOBAL MODEL SIZE TCR VALUE TOLERANCE TERMINATION PACKAGING CHPFR 0603 0805 1206 2010 2512 K = 100 ppm L = 200 ppm The first 3 digits are significant figures and the last digit specifies the number of zeros to follow. Example: 1R50 = 1.5 22R1 = 22.1 3901 = 3900 1004 = 1 M F=±1% G=±2% J=±5% B: SnPb over nickel barrier G: Gold For more information see Codification of Packaging table GLOBAL PART NUMBER INFORMATION ESCC Code: 400102613R1003F4 4 0 0 1 0 2 6 1 3 R 1 0 0 3 ESCC SPEC VARIANT FAILURE RATE RESISTANCE VALUE TOLERANCE 4001026 0603 = 11, 16 0805 = 12, 17 1206 = 13, 18 2010 = 14, 19 2512 = 15, 20 R The first 3 digits are significant figures and the last digit specifies the number of zeros to follow. Example: 3901 = 3900 1004 = 1 M F=±1% G=±2% J=±5% F 4 TEMPERATURE COEFFICIENT 4 = 100 ppm/°C 6 = 200 ppm/°C Note • MOQ for tape and reel: 50 pieces CROSS REFERENCE BETWEEN ESA PART NUMBER AND VISHAY PART NUMBER ESA PART NUMBER 4001026131003F4 Revision: 13-May-16 VISHAY PART NUMBER CHPFR1206K1003FB EXPLANATIONS 4001026 = CHPFR 13 = 1206 with B terminations 1003 = 1003 (100 k) F=F (tol. 1 %) 4=K (TCR 100 ppm/°C) Document Number: 52033 4 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 CHPFR www.vishay.com Vishay Sfernice HYPER FREQUENCY OPTION Hyper Frequency Option Numbering: HCHP0603K1001FBT55 H GLOBAL MODEL HCHP C H P 0 6 0 3 K 1 0 0 1 F B T 5 5 SIZE TCR VALUE TOLERANCE TERMINATION PACKAGING OPTION 0603 0805 1206 2010 2512 K = 100 ppm L = 200 ppm The first 3 digits are significant figures and the last digit specifies the number of zeros to follow. Example: 1R50 = 1.5 22R1 = 22.1 3901 = 3900 1004 = 1 M F=±1% G=±2% J=±5% B: SnPb over nickel barrier G: Gold Blank = Waffle pack T= Tape and reel 094 = HiRel production CROSS REFERENCE BETWEEN ESA PART NUMBER AND CHPFR PART NUMBER VARIANT ESA 11 12 13 14 15 16 17 18 19 20 VISHAY MODELS CHPFR0603/B terminations CHPFR0805/B terminations CHPFR1206/B terminations CHPFR2010/B terminations CHPFR2512/B terminations CHPFR0603/G terminations CHPFR0805/G terminations CHPFR1206/G terminations CHPFR2010/G terminations CHPFR2512/G terminations CODIFICATION OF PACKAGING CODIFICATION OF OPTIONS ON TWO DIGITS WAFFLE PACK W 100 min., 1 mult WA 100 min., 100 mult (available only in size 1206) PLASTIC TAPE T 100 min., 1 mult TA 100 min., 100 mult TB 250 min., 250 mult TC 500 min., 500 mult TD 1000 min., 1000 mult TE 2500 min., 2500 mult TF Full tape (qunatity depending on size of chips) PAPER TAPE PT 100 min., 1 mult PA 100 min., 100 mult PB 250 min., 250 mult PC 500 min., 500 mult PD 1000 min., 1000 mult PE 2500 min., 2500 mult PF Full tape (quantity depending on size of chips) OPTION .. 0099 0100 0101 0102 0103 0104 0105 .. 0124 0125 0126 0127 0128 .. 0320 0321 0322 0323 0324 0325 .. OPTION 2 DIGITS .. 99 0A 0B 0C 0D 0E 0F .. 0Y 0Z 1A 1B 1C .. 8M 8N 8O 8P 8Q 8R .. CODIFICATION OF SIZES CODE 18 C D H J L Revision: 13-May-16 CODE 40 0603 0805 1206 2010 2512 Document Number: 52033 5 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 CHPFR www.vishay.com Vishay Sfernice TRACEABILITY DEFINITIONS The two major traceability elements are defined as: • The primary process lot number named Front End lot (FE lot). One “FE lot”is composed of several wafers issued from the same thin film deposition sequence. • The date code named Batch Number(BN). The “BN” is defined after completion of the end of production testing sequence. The lot homogeneity is given by the “FE lot” and not by the “BN”. According to the applied rules validated by the ESCC through the product qualification, the following situations are agreed: • Parts coming from different “FE lost” might have the same “BN”. • A maximum of two different “BN” might be applied to the same “FE lot” to enable the use of overruns from a previous PO. • Unless requested / approved by the customer the “BN” will be 2 years old maximum. SPECIFIC TRACEABILITY REQUIREMENTS The following specific requirements have to be treated as: • A customer who requires “Lot Homogeneity” has to mention it on the PO as “SINGLE PRODUCTION LOT”. • A customer who requires “Lot Homogeneity” in addition to a “Single Batch Number” has to mention it on the PO as “SINGLE PRODUCTION LOT AND OPTION R0101”. END OF PRODUCTION TESTING Mandatory testing performed at the end of the production process: • 100 % overload: Voltage Revision: 13-May-16 6.25 P n x R n or 2 UL whichever is less - duration 2 s Document Number: 52033 6 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards. Revision: 02-Oct-12 1 Document Number: 91000