REVISIONS LTR DESCRIPTION DATE Prepared in accordance with ASME Y14.24 APPROVED Vendor item drawing REV PAGE REV PAGE REV STATUS OF PAGES REV PAGE 1 2 PMIC N/A PREPARED BY RICK OFFICER Original date of drawing YY-MM-DD CHECKED BY RAJESH PITHADIA 12-09-05 4 A REV 5 6 7 8 9 10 11 12 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http://www.landandmaritime.dla.mil/ TITLE MICROCIRCUIT, LINEAR, SINGLE SUPPLY, QUAD, OPERATIONAL AMPLIFIER, MONOLITHIC SILICON APPROVED BY CHARLES F. SAFFLE SIZE AMSC N/A 3 CODE IDENT. NO. DWG NO. V62/12634 16236 PAGE 1 OF 12 5962-V094-12 1. SCOPE 1.1 Scope. This drawing documents the general requirements of a high performance single supply quad operational amplifier microcircuit, with an operating temperature range of -55°C to +125°C. 1.2 Vendor Item Drawing Administrative Control Number. The manufacturer’s PIN is the item of identification. The vendor item drawing establishes an administrative control number for identifying the item on the engineering documentation: V62/12634 - Drawing number 01 X E Device type (See 1.2.1) Case outline (See 1.2.2) Lead finish (See 1.2.3) 1.2.1 Device type(s). Device type Generic Circuit function 01 AD8574 Zero drift, single supply, quad operational amplifier 1.2.2 Case outline(s). The case outline(s) are as specified herein. Outline letter Number of pins X 14 JEDEC PUB 95 Package style MO-153-AB-1 Plastic thin shrink small outline 1.2.3 Lead finishes. The lead finishes are as specified below or other lead finishes as provided by the device manufacturer: Finish designator A B C D E Z DLA LAND AND MARITIME COLUMBUS, OHIO Material Hot solder dip Tin-lead plate Gold plate Palladium Gold flash palladium Other SIZE A CODE IDENT NO. 16236 REV DWG NO. V62/12634 PAGE 2 1.3 Absolute maximum ratings. 1/ Supply voltage range (VS) .......................................................................................... 6 V Input voltage ............................................................................................................... Differential input voltage ............................................................................................. Power dissipation (PD) ............................................................................................... Output short circuit duration to GND .......................................................................... Storage temperature range (TSTG) ............................................................................ GND to VS + 0.3 V ±5.0 V 2/ 138.8 mW typical Indefinite -65°C to +150°C Junction temperature range (TJ) ................................................................................ -65°C to +150°C Lead temperature (soldering, 60 seconds) ................................................................. +300°C Thermal resistance, junction to case (θJC) ................................................................. 36°C/W Thermal resistance, junction to ambient (θJA) ............................................................ 180°C/W Electrostatic discharge: Human body model (HBM) ..................................................................................... 2000 V 1.4 Recommended operating conditions. 3/ Supply voltage range (VS) .......................................................................................... 5 V Operating free-air temperature range (TA) .................................................................. -55°C to +125°C 1/ 2/ 3/ Stresses beyond those listed under “absolute maximum rating” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. Differential input voltage is limited to ±5.0 V or the supply voltage, whichever is less. Use of this product beyond the manufacturers design rules or stated parameters is done at the user’s risk. The manufacturer and/or distributor maintain no responsibility or liability for product used beyond the stated limits. DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 16236 REV DWG NO. V62/12634 PAGE 3 2. APPLICABLE DOCUMENTS JEDEC PUB 95 – Registered and Standard Outlines for Semiconductor Devices (Applications for copies should be addressed to the Electronic Industries Alliance, 2500 Wilson Boulevard, Arlington, VA 22201-3834 or online at http://www.jedec.org) 3. REQUIREMENTS 3.1 Marking. Parts shall be permanently and legibly marked with the manufacturer’s part number as shown in 6.3 herein and as follows: A. B. C. Manufacturer’s name, CAGE code, or logo Pin 1 identifier ESDS identification (optional) 3.2 Unit container. The unit container shall be marked with the manufacturer’s part number and with items A and C (if applicable) above. 3.3 Electrical characteristics. The maximum and recommended operating conditions and electrical performance characteristics are as specified in 1.3, 1.4, and table I herein. 3.4 Design, construction, and physical dimension. The design, construction, and physical dimensions are as specified herein. 3.5 Diagrams. 3.5.1 Case outline. The case outline shall be as shown in 1.2.2 and figure 1. 3.5.2 Terminal connections. The terminal connections shall be as shown in figure 2. DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 16236 REV DWG NO. V62/12634 PAGE 4 TABLE I. Electrical performance characteristics. 1/ Test Symbol Conditions VS = 5 V, VCM = 2.5 , VO = 2.5 V unless otherwise specified Temperature, TA Device type Limits Min Unit Max Input characteristics. Offset voltage +25°C VOS 01 15 -55°C to +125°C Input bias current +25°C IB 01 -55°C to +125°C Input offset current +25°C IOS 01 VIN Common mode rejection ratio CMRR VCM = 0 V to 5 V +25°C 01 0 +25°C 01 120 AVO +25°C VO = 0.3 V to 4.7 V, RL = 10 kΩ 01 ∆VOS / ∆T 1.5 nA 70 pA 5 V dB 125 dB 120 -55°C to +125°C Offset voltage drift pA 115 -55°C to +125°C Large signal voltage 2/ gain 50 200 -55°C to +125°C Input voltage range µV 5 -55°C to +125°C 01 +25°C 01 0.04 µV/°C Output characteristics. Output voltage high VOH RL = 100 kΩ to GND RL = 10 kΩ to GND Output voltage low VOL -55°C to +125°C 4.99 +25°C 4.95 -55°C to +125°C 4.95 +25°C RL = 100 kΩ to +VS RL = 10 kΩ to +VS 4.99 01 V 10 -55°C to +125°C 10 +25°C 30 -55°C to +125°C 30 mV See footnotes at end of table. DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 16236 REV DWG NO. V62/12634 PAGE 5 TABLE I. Electrical performance characteristics – Continued. 1/ Test Symbol Conditions VS = 5 V, VCM = 2.5 , VO = 2.5 V unless otherwise specified Temperature, TA Device type Limits Min Unit Max Output characteristics – continued. Short circuit limit +25°C ISC 01 +25°C IO mA ±40 typical -55°C to +125°C Output current ±25 01 ±30 typical mA ±15 typical -55°C to +125°C Power supply. Power supply rejection ratio PSRR +25°C VS = 2.7 V to 5.5 V 01 ISY +25°C VO = 0 V dB 115 -55°C to +125°C Supply current per amplifier 120 01 µA 975 1075 -55°C to +125°C Dynamic performance. Slew rate SR RL = 10 kΩ Overload recovery time Gain bandwidth product GBP +25°C 01 0.4 typical +25°C 01 +25°C 01 1.5 typical MHz +25°C 01 1.3 typical µVpp V/µs 0.3 ms Noise performance. Voltage noise enp-p 0 Hz to 10 Hz 0 Hz to 1 Hz Voltage noise density en 0.41 typical f = 1 kHz +25°C 01 51 typical nV / Hz Current noise density in f = 10 Hz +25°C 01 2 typical fA / Hz See footnotes at end of table. DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 16236 REV DWG NO. V62/12634 PAGE 6 TABLE I. Electrical performance characteristics – Continued. 1/ Test Symbol Conditions VS = 2.7 V, VCM = 1.35 V, Temperature, TA Device type Limits Min VO = 1.35 V unless otherwise specified Unit Max Input characteristics. Offset voltage +25°C VOS 01 15 -55°C to +125°C Input bias current +25°C IB 01 -55°C to +125°C Input offset current +25°C IOS 01 VIN Common mode rejection ratio CMRR VCM = 0 V to 2.7 V +25°C 01 0 +25°C 01 115 AVO +25°C VO = 0.3 V to 2.4 V, RL = 10 kΩ 01 ∆VOS / ∆T 1.5 nA 50 pA 2.7 V dB 110 dB 105 -55°C to +125°C Offset voltage drift pA 110 -55°C to +125°C Large signal voltage 2/ gain 50 200 -55°C to +125°C Input voltage range µV 5 -55°C to +125°C 01 +25°C 01 0.04 µV/°C Output characteristics. Output voltage high VOH RL = 100 kΩ to GND RL = 10 kΩ to GND Output voltage low VOL -55°C to +125°C 2.685 +25°C 2.67 -55°C to +125°C 2.67 +25°C RL = 100 kΩ to +VS RL = 10 kΩ to +VS 2.685 01 V 10 -55°C to +125°C 10 +25°C 20 -55°C to +125°C 20 mV See footnotes at end of table. DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 16236 REV DWG NO. V62/12634 PAGE 7 TABLE I. Electrical performance characteristics – Continued. 1/ Test Symbol Conditions VS = 2.7 V, VCM = 1.35 V, Temperature, TA Device type Limits Min VO = 1.35 V unless otherwise specified Unit Max Output characteristics – continued. Short circuit limit +25°C ISC 01 +25°C IO mA ±10 typical -55°C to +125°C Output current ±10 01 ±10 typical mA ±5 typical -55°C to +125°C Power supply. Power supply rejection ratio PSRR +25°C VS = 2.7 V to 5.5 V 01 ISY +25°C VO = 0 V dB 115 -55°C to +125°C Supply current per amplifier 120 01 µA 900 1000 -55°C to +125°C Dynamic performance. Slew rate SR RL = 10 kΩ Overload recovery time Gain bandwidth product GBP +25°C 01 0.5 typical V/µs +25°C 01 0.05 typical ms +25°C 01 1.0 typical MHz Noise performance. Voltage noise enp-p 0 Hz to 10 Hz +25°C 01 2.0 typical µVpp Voltage noise density en f = 1 kHz +25°C 01 94 typical nV / Hz Current noise density in f = 10 Hz +25°C 01 2 typical fA / Hz 1/ Testing and other quality control techniques are used to the extent deemed necessary to assure product performance over the specified temperature range. Product may not necessarily be tested across the full temperature range and all parameters may not necessarily be tested. In the absence of specific parametric testing, product performance is assured by characterization and/or design. 2/ Gain testing is dependent upon test bandwidth. DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 16236 REV DWG NO. V62/12634 PAGE 8 Case X FIGURE 1. Case outline. DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 16236 REV DWG NO. V62/12634 PAGE 9 Case X Dimensions Inches Symbol Millimeters Min Max Min Max A --- .047 --- 1.20 A1 .001 .005 0.05 0.15 A2 .031 .041 0.80 1.05 b .007 .011 0.19 0.30 c .003 .007 0.09 0.20 D .192 .200 4.90 5.10 E .169 .177 4.30 4.50 E1 .251 BSC 6.40 BSC e .025 BSC 0.65 BSC L .017 .028 0.45 0.75 NOTES: 1. Controlling dimensions are millimeter, inch dimensions are given for reference only. 2. Falls within reference to JEDEC MO-153-AB-1. FIGURE 1. Case outline - Continued. DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 16236 REV DWG NO. V62/12634 PAGE 10 Device type 01 Case outline X Terminal number Terminal symbol 1 OUTPUT A 2 -INPUT A 3 +INPUT A 4 +VS 5 +INPUT B 6 -INPUT B 7 OUTPUT B 8 OUTPUT C 9 -INPUT C 10 +INPUT C 11 -VS 12 +INPUT D 13 -INPUT D 14 OUTPUT D FIGURE 2. Terminal connections. DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 16236 REV DWG NO. V62/12634 PAGE 11 4. VERIFICATION 4.1 Product assurance requirements. The manufacturer is responsible for performing all inspection and test requirements as indicated in their internal documentation. Such procedures should include proper handling of electrostatic sensitive devices, classification, packaging, and labeling of moisture sensitive devices, as applicable. 5. PREPARATION FOR DELIVERY 5.1 Packaging. Preservation, packaging, labeling, and marking shall be in accordance with the manufacturer’s standard commercial practices for electrostatic discharge sensitive devices. 6. NOTES 6.1 ESDS. Devices are electrostatic discharge sensitive and are classified as ESDS class 1 minimum. 6.2 Configuration control. The data contained herein is based on the salient characteristics of the device manufacturer’s data book. The device manufacturer reserves the right to make changes without notice. This drawing will be modified as changes are provided. 6.3 Suggested source(s) of supply. Identification of the suggested source(s) of supply herein is not to be construed as a guarantee of present or continued availability as a source of supply for the item. DLA Land and Maritime maintains an online database of all current sources of supply at http://www.landandmaritime.dla.mil/Programs/Smcr/. Vendor item drawing administrative control number 1/ Device manufacturer CAGE code Transport media, quantity Vendor part number V62/12634-01XE 24355 Reel, 2500 AD8574TRU-EP-RL Tube, 96 AD8574TRU-EP 1/ The vendor item drawing establishes an administrative control number for identifying the item on the engineering documentation. CAGE code 24355 DLA LAND AND MARITIME COLUMBUS, OHIO Source of supply Analog Devices Route 1 Industrial Park P.O. Box 9106 Norwood, MA 02062 Point of contact: Raheen Business Park Limerick, Ireland SIZE A CODE IDENT NO. 16236 REV DWG NO. V62/12634 PAGE 12